Modeling the Error of Continuous Glucose Monitoring Sensor Data: Critical Aspects Discussed through Simulation Studies
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Knowing the statistical properties of continuous glucose monitoring (CGM) sensor errors can be important in several practical applications, e.g., in both open- and closed-loop control algorithms. Unfortunately, modeling the accuracy of CGM sensors is very difficult for both experimental and methodological reasons. It has been suggested that the time series of CGM sensor errors can be described as realization of the output of an autoregressive (AR) model of first order driven by a white noise process. The AR model was identified exploiting several reference blood glucose (BG) samples (collected frequently in parallel to the CGM signal), a procedure to recalibrate CGM data, and a linear time-invariant model of blood-to-interstitium glucose (BG-to-IG) kinetics. By resorting to simulation, this work shows that some assumptions made in the Breton and Kovatchev modeling approach may significantly affect the estimated sensor error and its statistical properties. Method: Three simulation studies were performed. The first simulation was devoted to assessing the influence of CGM data recalibration, whereas the second and third simulations examined the role of the BG-to-IG kinetic model. Analysis was performed by comparing the “original” (synthetically generated) time series of sensor errors vs its “reconstructed” version in both time and frequency domains. Results: Even small errors either in CGM data recalibration or in the description of BG-to-IG dynamics can severely affect the possibility of correctly reconstructing the statistical properties of sensor error. In particular, even if CGM sensor error is a white noise process, a spurious correlation among its samples originates from suboptimal recalibration or from imperfect knowledge of the BG-to-IG kinetics. Conclusions: Modeling the statistical properties of CGM sensor errors from data collected in vivo is difficult because it requires perfect calibration and perfect knowledge of BG-to-IG dynamics. Results suggest that correct characterization of CGM sensor error is still an open issue and requires further development upon the pioneering contribution of Breton and Kovatchev.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationDeiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Self-citationGIM, Simulation Software of Meal Glucose–Insulin Model
Dalla Man, C., Raimondo, D. M., Rizza, R. A., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100303 · Cited by 253
Self-citation
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationService, F. J. (2013) · Diabetes · doi:10.2337/db12-1396 · Cited by 221
“Although not constrained by that limitation, continuous interstitial glucose monitoring is hampered by variable and unpredictable inaccuracies (51).”
BackgroundRebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Modeling the glucose sensor error
Facchinetti, A., Del Favero, S., Sparacino, G., Castle, J. R., Ward, W. K., & Cobelli, C. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2284023 · Cited by 130
“This model was able to describe some of the random fluctuations visible on CGM experimental data, but it is suboptimal because it cannot describe errors due to calibration and sensor drift nor deal with interindividual variability of the BG-to-IG kinetics [33].”
BackgroundSelf-citationFacchinetti, A., Favero, S., Sparacino, G., & Cobelli, C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2227256 · Cited by 62
Self-citation
Metadata
- Authors
- Facchinetti, A., Sparacino, G., & Cobelli, C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-01
- Volume
- 4
- Issue
- 1
- Pages
- 4-14
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W1973641708
- Cited by
- 67
- References
- 5
- Type
- conference abstract
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling the Error of Continuous Glucose Monitoring Sensor Data: Critical Aspects Discussed through Simulation Studies. https://app.cochat.ai/papers/10.1177/193229681000400102
- The paper
- Facchinetti, A., Sparacino, G., & Cobelli, C. (2010). Modeling the Error of Continuous Glucose Monitoring Sensor Data: Critical Aspects Discussed through Simulation Studies. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681000400102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.