Predicting Subcutaneous Glucose Concentration Using a Latent-Variable-Based Statistical Method for Type 1 Diabetes Mellitus
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: Accurate prediction of future glucose concentration for type 1 diabetes mellitus (T1DM) is needed to improve glycemic control and to facilitate proactive management before glucose concentrations reach undesirable concentrations. The availability of frequent glucose measurements, insulin infusion rates, and meal carbohydrate estimates can be used to good advantage to capture important information concerning glucose dynamics. Methods: This article evaluates the feasibility of using a latent variable (LV)-based statistical method to model glucose dynamics and to forecast future glucose concentrations for T1DM applications. The prediction models are developed using a proposed LV-based approach and are evaluated for retrospective clinical data from seven individuals with T1DM and for In silico simulations using the Food and Drug Administration-accepted University of Virginia/University of Padova metabolic simulator. This article provides comparisons of the prediction accuracy of the LV-based method with that of a standard modeling alternative. The influence of key design parameters on the performance of the LV-based method is also illustrated. Results: In general, the LV-based method provided improved prediction accuracy in comparison with conventional autoregressive (AR) models and autoregressive with exogenous input (ARX) models. For larger prediction horizons (=30 min), the LV-based model with exogenous inputs achieved the best prediction performance based on a paired t-test (α = 0.05). Conclusions: The LV-based method resulted in models whose glucose prediction accuracy was as least as good as the accuracies of standard AR/ARX models and a simple model-free approach. Furthermore, the new approach is less sensitive to changing conditions and the effect of key design parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L. (2004) · Diabetes Care · doi:10.2337/diacare.27.8.1922 · Cited by 312
Rabasa-Lhoret, R., Garon, J., Langelier, H., Poisson, D., & Chiasson, J. L. (1999) · Diabetes Care · doi:10.2337/diacare.22.5.667 · Cited by 210
Cited by
Convolutional Recurrent Neural Networks for Glucose Prediction
Li, K., Daniels, J., Liu, C., Herrero, P., & Georgiou, P. (2020) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2908488 · Cited by 310
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
Continuous glucose monitoring sensors: past, present and future algorithmic challenges
Facchinetti, A. (2016) · Sensors · doi:10.3390/s16122093 · Cited by 176
“…algorithms, also exploiting other signals like the amount of insulin injected or physical activity, can be employed, e.g., those of Zhao et al. [9,12], Zecchin et al. [13,41], Turksoy et al. [10], Zarkogianni et al. [11], and Georga et al. [42,43] The algorithmically “smart” CGM sensor concept…”
MethodZecchin, C., Facchinetti, A., Sparacino, G., & Cobelli, C. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816654161 · Cited by 64
Camerlingo, N., Vettoretti, M., Del Favero, S., Cappon, G., Sparacino, G., & Facchinetti, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0139 · Cited by 22
“With such advance, compared to the ADA guidelines, the proposed algorithm succeeds in reducing both T Hypo (from 41 [28–49] min to 25 [0–41] min in the slow hypo-descent scenario and from 54 [45–61] min to 45 [12–55] 1.”
Metadata
- Authors
- Zhao, C., Dassau, E., Jovanovič, L., Zisser, H. C., Doyle, F. J., & Seborg, D. E.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2012-05
- Volume
- 6
- Issue
- 3
- Pages
- 617-633
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2120315766
- Cited by
- 60
- References
- 3
- FWCI
- 3.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Predicting Subcutaneous Glucose Concentration Using a Latent-Variable-Based Statistical Method for Type 1 Diabetes Mellitus. https://app.cochat.ai/papers/10.1177/193229681200600317
- The paper
- Zhao, C., Dassau, E., Jovanovič, L., Zisser, H. C., Doyle, F. J., & Seborg, D. E. (2012). Predicting Subcutaneous Glucose Concentration Using a Latent-Variable-Based Statistical Method for Type 1 Diabetes Mellitus. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681200600317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.