Continuous Glucose Monitoring: Evidence and Consensus Statement for Clinical Use
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Continuous glucose monitoring (CGM) is an essential tool for modern diabetes therapy. Randomized controlled studies have provided evidence that hemoglobin A1c (HbA1c) results can be improved in patients with type 1 diabetes with elevated baseline HbA1c when using CGM frequently enough and that the frequency and duration of hypoglycemic events can be reduced in patients with satisfactory baseline HbA1c. The CGM group within the Working Group Diabetes Technology (AGDT) of the German Diabetes Association (DDG) has defined evidence-based indications for the practical use of CGM in this consensus statement related to hypoglycemia (frequent, severe, or nocturnal) or hypoglycemia unawareness, insufficient metabolic control despite use of all possible therapeutic options and patient compliance, pregnancy associated with inadequate blood glucose results, and the need for more than 10 blood glucose measurements per day. Contraindications and defined preconditions for the successful use of CGM should be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of Medical Care in Diabetes—2012
(2012) · Diabetes Care · doi:10.2337/dc12-s011 · Cited by 2,240
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
the SWITCH Study Group, Battelino, T., Conget, I., Olsen, B., Schütz-Fuhrmann, I., Hommel, E., Hoogma, R., Schierloh, U., Sulli, N., & Bolinder, J. (2012) · Diabetologia · doi:10.1007/s00125-012-2708-9 · Cited by 494
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Cited by
Continuous glucose monitoring: a review of recent studies demonstrating improved glycemic outcomes
Rodbard, D. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0035 · Cited by 458
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Christensen, A. S., Hædersdal, S., Støy, J., Storgaard, H., Kampmann, U., Forman, J. L., Seghieri, M., Holst, J. J., Hansen, T., Knop, F. K., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0408 · Cited by 48
Metadata
- Authors
- Liebl, A., Henrichs, H. R., Heinemann, L., Freckmann, G., Biermann, E., Thomas, A., & for the Continuous Glucose Monitoring Working Group of the Working Group Diabetes Technology of the German Diabetes Association
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2013-03
- Volume
- 7
- Issue
- 2
- Pages
- 500-519
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2132278645
- Cited by
- 77
- References
- 17
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous Glucose Monitoring: Evidence and Consensus Statement for Clinical Use. https://app.cochat.ai/papers/10.1177/193229681300700227
- The paper
- Liebl, A., Henrichs, H. R., Heinemann, L., Freckmann, G., Biermann, E., Thomas, A., & for the Continuous Glucose Monitoring Working Group of the Working Group Diabetes Technology of the German Diabetes Association. (2013). Continuous Glucose Monitoring: Evidence and Consensus Statement for Clinical Use. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700227
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.