Time Lag of Glucose From Intravascular to Interstitial Compartment in Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Background and Objective: The premise of effective closed-loop insulin therapy for type 1 diabetes (T1D) relies on the accuracy of continuous interstitial fluid glucose sensing that represents the crucial afferent arm of such a system. An important determinant of sensor accuracy is the physiological time lag of glucose transport from the vascular to the interstitial space. The purpose of current studies was to determine the physiological time lag of glucose transport from the vascular to the abdominal subcutaneous interstitial space in T1D. Method: Four microdialysis catheters were inserted into the abdominal subcutaneous space in 6 T1D subjects under overnight fasted conditions. Plasma glucose was maintained at 113.7 ± 6.3 mg/dl using a continuous intravenous insulin infusion. After sequential intravenous bolus administrations of glucose isotopes, timed plasma and interstitial fluid samples were collected chronologically and analyzed for tracer enrichments. Results: We observed a median (range) time lag of tracer appearance (time to detection) into the interstitial space after intravenous bolus of 6.8 (4.8-9.8) minutes, with all participants having detectable values by 9.8 minutes. Conclusions: We conclude that in the overnight fasted state in T1D adults, the delay of glucose appearance from the vascular to the interstitial space is less than 10 minutes, thereby implying that this minimal physiological time lag should not be a major impediment to the development of an effective closed-loop control system for T1D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.277.3.e561 · Cited by 366
Steil, G. M., Volund, A., Kahn, S. E., & Bergman, R. N. (1993) · Diabetes · doi:10.2337/diab.42.2.250 · Cited by 215
Time Lag of Glucose From Intravascular to Interstitial Compartment in Humans
Basu, A., Dube, S., Slama, M., Errazuriz, I., Amezcua, J. C., Kudva, Y. C., Peyser, T., Carter, R. E., Cobelli, C., & Basu, R. (2013) · Diabetes · doi:10.2337/db13-1132 · Cited by 205 · cited 11×
“A dual-energy X-ray absorptiometry (DXA) scan was performed to measure body composition.(8) Subjects who met the enrollment criteria were asked to return for the study visit within 2-3 weeks.”
BackgroundMethodResultSelf-citationRebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152 · cited 1×
“Studies done at Medtronic identified numerical processing algorithms as the single most important factor in contributing to the appearance of lag time between blood glucose and CGM measurements of interstitial glucose.(2,3) Studies done by Dexcom Inc, on this issue with the earlier generation Dexcom SEVENTM continuous…”
MethodDiabetic Lipohypertrophy Delays Insulin Absorption
Young, R. J., Hannan, W. J., Frier, B. M., Steel, J. M., & Duncan, L. J. P. (1984) · Diabetes Care · doi:10.2337/diacare.7.5.479 · Cited by 145
Basu, A., Dalla Man, C., Basu, R., Toffolo, G., Cobelli, C., & Rizza, R. A. (2009) · Diabetes Care · doi:10.2337/dc08-1826 · Cited by 129 · cited 1×
“Plasma glucose concentrations were analyzed as described previously.(11) Microdialysis and plasma samples for stable tracer enrichment were analyzed by gas chromatography mass spectrometry (GCMS) as described previously.”
MethodSelf-citationWHITE, N. H., SKOR, D., & SANTIAGO, J. V. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-2-210 · Cited by 108 · cited 1×
“Intravenous insulin infusion was started at ~2100 hours and continued throughout the rest of the study as per protocol to maintain euglycemia.(9) Insulin pump was discontinued for those on the insulin pump when the intravenous insulin infusion was started and those who were on multiple daily insulin did not administer…”
MethodDetermination of Plasma Glucose During Rapid Glucose Excursions with a Subcutaneous Glucose Sensor
Steil, G. M., Rebrin, K., Mastrototaro, J., Bernaba, B., & Saad, M. F. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503763816436 · Cited by 104
Poor glycaemic control caused by insulin induced lipohypertrophy
Chowdhury, T. A., & Escudier, V. (2003) · BMJ · doi:10.1136/bmj.327.7411.383 · Cited by 103
Analysis of Time Lags and Other Sources of Error of the DexCom SEVEN Continuous Glucose Monitor
Kamath, A., Mahalingam, A., & Brauker, J. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0060 · Cited by 69
Cited by
Diabetes: Advances in Diagnosis and Treatment
Nathan, D. M. (2015) · JAMA · doi:10.1001/jama.2015.9536 · Cited by 384
The lymphatic system: integral roles in immunity
Randolph, G. J., Ivanov, S., Zinselmeyer, B. H., & Scallan, J. P. (2017) · Annual Review of Immunology · doi:10.1146/annurev-immunol-041015-055354 · Cited by 338
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
“These delays are compounded by the inherent 5–15 min lag between glucose values in the interstitial and vascular space [60, 61].”
BackgroundMeasures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170
Self-citationTime Delay of CGM Sensors: Relevance, Causes, and Countermeasures
Schmelzeisen-Redeker, G., Schoemaker, M., Kirchsteiger, H., Freckmann, G., Heinemann, L., & del Re, L. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815590154 · Cited by 161
“Other estimates using the same approach for a very small study population report a similar value for patients with type 1 diabetes.(8) There is strong evidence for a great variability of the time delay between individual subjects even under reproducible experimental conditions and independently of a specific CGM syste…”
ResultGingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
“The time delay can vary from 3 to 12 minutes and is highest when BG levels are rapidly changing, such is the case post meals or during exercise.(67,68) These sensor delays remain one of the main challenges faced by CLS algorithms and can affect the efficacy of the artificial pancreas in regards to meals.”
Standardization process of continuous glucose monitoring: Traceability and performance
Freckmann, G., Nichols, J. H., Hinzmann, R., Klonoff, D. C., Ju, Y., Diem, P., Makris, K., & Slingerland, R. J. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.12.025 · Cited by 62
Choudhary, P., & Amiel, S. A. (2018) · Diabetologia · doi:10.1007/s00125-018-4566-6 · Cited by 52
“concentrations are changing rapidly [76, 77].”
Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46
“Of course, both glucose concentrations are closely related by a diffusion process, and CGM readings can be calibrated to correspond to the equivalent SMBG values under steady state values, but larger differences arise when glucose levels are rapidly changing, in which cases changes the BG values exhibit time differenc…”
BackgroundMerino, J., Linenberg, I., Bermingham, K. M., Ganesh, S., Bakker, E., Delahanty, L. M., Chan, A. T., Capdevila Pujol, J., Wolf, J., Al Khatib, H., et al. (2022) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqac026 · Cited by 46
Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments
Pfützner, A., Strobl, S., Demircik, F., Redert, L., Pfützner, J., Pfützner, A. H., & Lier, A. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818758769 · Cited by 33
“This lag time has been described to last from less than 10 minutes to more than 45 minutes based on the diabetes stage, and in particular also related to the severity of secondary microcirculation disorders.(25-27) This fact explains why NI glucose monitoring methods are considered to be of limited efficacy in emergen…”
BackgroundEvaluation of flash glucose monitoring after long-term use: a pediatric survey
Vergier, J., Samper, M., Dalla-Vale, F., Ventura, V., Baucher, F., Joubert, F., Pons, C., De Oliveira, M., Salet, R., Faure-Galon, N., et al. (2019) · Primary Care Diabetes · doi:10.1016/j.pcd.2018.08.004 · Cited by 32
Metadata
- Authors
- Basu, A., Dube, S., Veettil, S., Slama, M., Kudva, Y. C., Peyser, T., Carter, R. E., Cobelli, C., & Basu, R.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-10-10
- Volume
- 9
- Issue
- 1
- Pages
- 63-68
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W1989350580
- Cited by
- 164
- References
- 17
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.