Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring
Abstract
The present study investigated the relationship between blood and subcutaneous interstitial fluid (ISF) glucose by employing an amperometric glucose sensor specifically developed for 3-day continuous glucose monitoring. The apparent sensor sensitivity and ISF glucose equilibration delay were estimated on separate days during hyperglycemic clamps in four dogs in which insulin was either suppressed with somatostatin, allowed to change, or increased with an exogenous infusion. A 2-h sensor “settling-in” period was allowed before the clamps. During insulin deficiency, the sensor sensitivity and ISF glucose delay were 0.23 ± 0.03 nA per mg/dl and 4.4 ± 0.8 min. Sensitivity was not affected by increases in endogenous (0.30 ± 0.04 vs. 0.28 ± 0.04 nA per mg/dl) or exogenous insulin (0.18 ± 0.01 vs. 0.16 ± 0.01 nA per mg/dl) nor was the delay (3.3 ± 1.2 vs. 5.7 ± 1.1 and 9.2 ± 2.6 vs. 12.3 ± 1.7 min; P > 0.05 for all). Sensor glucose accurately predicted plasma glucose without correcting for delays <10 min ( r > 0.9 for all), whereas for longer delays a digital corrective filter was used ( r = 0.91 with filter). We conclude that the relationship between blood and ISF glucose is not affected by insulin and that delays in ISF glucose equilibration can be corrected with digital filters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Cited by
Type 1 diabetes: new perspectives on disease pathogenesis and treatment
Atkinson, M. A., & Eisenbarth, G. S. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05415-0 · Cited by 1,491
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“fall in IG would precede fall in BG [196], [212].”
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Metadata
- Authors
- Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1999-09-01
- Volume
- 277
- Issue
- 3
- Pages
- E561-E571
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2095833129
- Cited by
- 366
- References
- 1
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. https://app.cochat.ai/papers/10.1152/ajpendo.1999.277.3.e561
- The paper
- Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J. (1999). Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1999.277.3.e561
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.