Clinical Accuracy of a Continuous Glucose Monitoring System With an Advanced Algorithm
Open accessAbstract
Background: We assessed the performance of a modified Dexcom G4 Platinum system with an advanced algorithm, in comparison with frequent venous samples measured on a laboratory reference (YSI) during a clinic session and in comparison to self-monitored blood glucose (SMBG) during home use. Methods: Fifty-one subjects with diabetes were enrolled in a prospective multicenter study. Subjects wore 1 sensor for 7-day use and participated in one 12-hour in-clinic session on day 1, 4, or 7 to collect YSI reference venous glucose every 15 minutes and capillary SMBG test every 30 minutes. Carbohydrate consumption and insulin dosing and timing were manipulated to obtain data in low and high glucose ranges. Results: In comparison with the laboratory reference method (n = 2,263) the system provided a mean and median absolute relative differences (ARD) of 9.0% and 7.0%, respectively. The mean absolute difference for CGM was 6.4 mg/dL when the YSIs were within hypoglycemia ranges (≤ 70 mg/dL). The percentage in the clinically accurate Clarke error grid A zone was 92.4% and in the benign error B zone was 7.1%. Majority of the sensors (73%) had an aggregated MARD in reference to YSI ≤ 10%. The MARD of CGM-SMBG for home use was 11.3%. Conclusions: The study showed that the point and rate accuracy, clinical accuracy, reliability, and consistency over the duration of wear and across glycemic ranges were superior to current commercial real-time CGM systems. The performance of this CGM is reaching that of a self-monitoring blood glucose meter in real use environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“continuous glucose monitoring (CGM) and intermittently viewed CGM devices for at-home patient use with minimally invasive devices have become available, which have similar accuracy to capillary blood glucose monitors.91”
From Type 1 diabetes (2018) · cites this paper as [91]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Errors in CGM also increase the difficulty of predicting BG values (approximately 9% of the mean absolute relative difference for the best sensors70).”
From Artificial intelligence in diabetes management: Advancements, opportunities, and challenges (2023) · cites this paper as [70]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“CGM utilizes subcutaneous sensors for continuous monitoring of glucose levels with a high degree of accuracy. 17 , 18”
From Insulin pump therapy is associated with higher rates of mild diabetic ketoacidosis compared to injection therapy: A 2‐year Swedish national survey of children and adolescents with type 1 diabetes (2022) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
“Turn it Off!”: Diabetes Device Alarm Fatigue Considerations for the Present and the Future
Shivers, J. P., Mackowiak, L., Anhalt, H., & Zisser, H. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700324 · Cited by 159
Christiansen, M. P., Bailey, T. S., Watkins, E., Liljenquist, D. R., Price, D. A., Nakamura, K., Boock, R. J., & Peyser, T. A. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0077 · Cited by 140
Self-citationA Comparative Effectiveness Analysis of Three Continuous Glucose Monitors
Damiano, E. R., McKeon, K., El-Khatib, F. H., Zheng, H., Nathan, D. M., & Russell, S. J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532203 · Cited by 139
Kropff, J., Bruttomesso, D., Doll, W., Farret, A., Galasso, S., Luijf, Y. M., Mader, J. K., Place, J., Boscari, F., Pieber, T. R., et al. (2014) · Diabetes Obesity and Metabolism · doi:10.1111/dom.12378 · Cited by 132
Šoupal, J., Škrha, J., Fajmon, M., Horová, E., Mráz, M., Škrha, J., & Prázný, M. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0205 · Cited by 122
Mazze, R. S., Strock, E. S., Borgman, S. K., Wesley, D., Stout, P. J., & Racchini, J. R. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0041 · Cited by 116
Accuracy and Acceptability of the 6-Day Enlite Continuous Subcutaneous Glucose Sensor
Bailey, T. S., Ahmann, A., Brazg, R., Christiansen, M. P., Garg, S. K., Watkins, E., Welsh, J. B., & Lee, S. W. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0222 · Cited by 106
Self-citationTack, C. J., Pohlmeier, H., Behnke, T., Schmid, V., Grenningloh, M., Forst, T. M., & Pfützner, A. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0170 · Cited by 91
Research works printed but not linked: 5
- Christiansen M, 2013, Diabetes Technol Ther, 5, 1
- Kropff J, 2014, Diabetes Obes Metab
- Brauker JH, 2007, Review of Endocrinology
- Pettus J, 2014, Diabetes Technol Ther, 16, 198
- Hessler DM, Paper presented at: 71st American Diabetes Association meeting
Cited by
Sorted by citations
Items 101–168 of 168
Noninvasive Glucose Monitor Using Dielectric Spectroscopy
Buehler, L. A., Balasubramanian, V., Baskerville, S., Bailey, R. J., McCarthy, K., Rippen, M., Bena, J., & Lansang, M. C. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.09.010 · Cited by 7
Freckmann, G., Schlüter, S., Heinemann, L., & on behalf of the Diabetes Technology Working Group of the German Diabetes Society (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817721004 · Cited by 7
Continuous Glucose Monitoring for In-Flight Measurement of Glucose Levels of Insulin-Treated Pilots
Strollo, F., Simons, R., Mambro, A., Strollo, G., & Gentile, S. (2019) · Aerospace Medicine and Human Performance · doi:10.3357/amhp.5315.2019 · Cited by 7
Seibold, A., & Schlaeger, C. (2018) · Diabetic Medicine · doi:10.1111/dme.13696 · Cited by 7
Pleus, S., Eichenlaub, M., Waldenmaier, D., & Freckmann, G. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241236504 · Cited by 7
Translational medicine and biomaterials
Roy, A. K., Jones, A. D., & Webster, T. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813477-1.00001-3 · Cited by 6
Noaro, G., Cappon, G., Sparacino, G., Boscari, F., Bruttomesso, D., & Facchinetti, A. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211043162 · Cited by 6
Seibold, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0358 · Cited by 6
Characteristics of Nocturnal Hypoglycaemic Events and Their Impact on Glycaemia
Eichenlaub, M., Öter, Ş., Waldenmaier, D., Kulzer, B., Heinemann, L., Ziegler, R., Schnell, O., Glatzer, T., & Freckmann, G. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241267765 · Cited by 6
LA PERSONA CON DIABETE TIPO 1 E LE IMMERSIONI SUBACQUEE
Bonomo, M. A., Careddu, G., Corigliano, G., Bartolo, P. D., Longobardi, P., Fazi, A., Cimino, E., Gamarra, E., & Valentini, U. (2019) · il Diabete · doi:10.30682/ildia1901c · Cited by 5
Contreras, I., Calm, R., Sainz, M. Á., Herrero, P., & Vehı́, J. (2021) · Mathematics · doi:10.3390/math9060631 · Cited by 5
Overview of modern sensors for continuous glucose monitoring
Темиргалиевич, М. К., Прокопьев, М. В., & Ivanov, I. V. (2023) · Diabetes Mellitus · doi:10.14341/dm13043 · Cited by 5
Is Continuous Glucose Monitoring Underappreciated in the UK?
Parkin, C. G., Holloway, M., Truesdell, J., & Walker, T. C. (2017) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2017.13.02.76 · Cited by 5
Setford, S. J., Grady, M., Mackintosh, S., Donald, R., & Levy, B. L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818776668 · Cited by 5
Jensen, M. H., Dethlefsen, C., Hejlesen, O. K., & Vestergaard, P. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819848721 · Cited by 5
Assessing Insulin Delivery Device Satisfaction in Patients with Type 1 and Type 2 Diabetes
Snell‐Bergeon, J. K. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0260 · Cited by 5
Reddy, M., & Oliver, N. S. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0378 · Cited by 6
Artificial intelligence-based decision support systems for diabetes
Contreras, I., Bertachi, A. H., Biagi, L., Oviedo, S., Ramkissoon, C. M., & Vehı́, J. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817133-2.00014-8 · Cited by 4
Jenie, R. P., Damayanthi, E., Irzaman, I., Rimbawan, R., Sukandar, D., Nurdin, N. M., & Alatas, H. (2019) · Journal of Medical Devices · doi:10.1115/1.4044336 · Cited by 4
Garnica, Ó., Lanchares, J., Velasco, J. M., Hidalgo, J. I., & Botella, M. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2020.101934 · Cited by 4
Out-of-Hospital Data: Patient Generated Health Data
Lee, J., Kim, H., & Kim, J. (2020) · Journal of Korean Diabetes · doi:10.4093/jkd.2020.21.3.149 · Cited by 3
Upcoming Devices for Diabetes Management: The Artificial Pancreas as the Hallmark Device
Lee, S. W., & Welsh, J. B. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0303 · Cited by 4
The Future of the Artificial Pancreas
Thabit, H., & Hovorka, R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0297 · Cited by 5
Habte‐Asres, H. H., Suglo, J. N., Chaudhry, K., Forbes, A., Wheeler, D. C., & Karalliedde, J. J. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251353811 · Cited by 3
Fleming, H. A., Stasiak, M. K., Lau, I. H. W., Whines, A., Mehrhof, S. Z., & Nord, C. L. (2025) · Biological Psychiatry Global Open Science · doi:10.1016/j.bpsgos.2025.100645 · Cited by 3
Welsh, J. B., Walker, T. C., & Price, D. A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817694180 · Cited by 3
The First Hybrid Closed-Loop Insulin Pump: Will It Meet Its Potential?
Hirsch, I. B. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0045 · Cited by 3
Bailey, T. S., Alva, S., Bode, B. W., Christiansen, M. P., & Klaff, L. J. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0093 · Cited by 3
Self-citationPharmacological aspects of closed loop insulin delivery for type 1 diabetes
Uduku, C. N., & Oliver, N. S. (2017) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2017.07.006 · Cited by 5
Kublin, O., & Stȩpień, M. (2019) · Clinical Diabetology · doi:10.5603/dk.2019.0006 · Cited by 3
Schiavon, M., Vella, A. V., & Man, C. D. (2025) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00407.2024 · Cited by 2
Selim, K. K., Farag, A., & Abdellatif, S. O. (2026) · Microsystem Technologies · doi:10.1007/s00542-026-06022-3 · Cited by 3
Mark‐Wagstaff, C., Deshmukh, H., Wilmot, E. G., Walker, N. M., Barnes, D., Parfitt, V. J., Saunders, S., Gregory, R., Choudhary, P., Patmore, J., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15283 · Cited by 2
Lu, L., Yin, X., Wang, C., Meng, X., Li, G., & Zhu, W. (2025) · Biological Research For Nursing · doi:10.1177/10998004251344888 · Cited by 2
Mahmoudi, Z., Johansen, M. D., Nørgaard, H. H., Andersen, S., Pedersen‐Bjergaard, U., Tarnow, L., Christiansen, J. S., & Hejlesen, O. K. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815587935 · Cited by 2
P1.04 - Miniatur-Fluoreszenzphotometer für kontinuierliche Blutzuckermessung
Müller, R., Ortlepp, H.-G., Krivánek, R., Müller, A., Brodersen, O., & Ortlepp, T. (2017) · Tagungsband · doi:10.5162/13dss2017/p1.04 · Cited by 2
Continuous glucose monitoring: review of promising technologies
Klimek, M., & Tulwin, T. (2019) · MATEC Web of Conferences · doi:10.1051/matecconf/201925202012 · Cited by 2
Bukara-Radujković, G., Miljković, V., & Lakić, S. (2018) · Vojnosanitetski pregled · doi:10.2298/vsp170908106b · Cited by 2
Surgical options for glycaemic control in Type 1 diabetes
Yeung, K., Reddy, M., & Purkayastha, S. (2019) · Diabetic Medicine · doi:10.1111/dme.13885 · Cited by 2
Laakso, E., Hona, T. W. P. T., Vassão, P. G., & Griffin, A. (2021) · Photobiomodulation Photomedicine and Laser Surgery · doi:10.1089/photob.2021.0012 · Cited by 2
Kolnes, K. J., Turner, L. V., Brufladt, S., Nilsen, E., Kolnes, A. J., O’Rahilly, S., JENSEN, J., & Riddell, M. C. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261421956 · Cited by 2
Logothetis, G., Avramidis, K., Konstantaki, E., Matziou, V. N., & Doupis, J. (2025) · touchREVIEWS in Endocrinology · doi:10.17925/ee.2025.21.1.7 · Cited by 1
Metabolic Disorders and Management of High-Risk Patients
Edmonds, M. E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-7020-6223-0.00010-8 · Cited by 1
On Standardization and Evaluation of Continuous Glucose Monitoring Systems
Темиргалиевич, М. К., Прокопьев, М. В., & Ivanov, I. V. (2024) · Measurement Standards Reference Materials · doi:10.20915/2077-1177-2023-19-5-113-125 · Cited by 1
An Analysis of the Distribution of Direct Cost of Diabetes Care in Selected Districts in Italy
Mennini, F. S., Sciattella, P., Marcellusi, A., Bartolini, F., Bernardi, F. F., Levrat‐Guillen, F., Cozzolino, M., Gennaro, M. D., Giordana, R., Giustozzi, M., et al. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01580-z · Cited by 1
Noninvasive monitoring of urine glucose using phase lock-in rotating analyzer polarimeter
Rehan, I., Ullah, R., Rehan, K., & Ullah, R. (2025) · Laser Physics · doi:10.1088/1555-6611/adf0f2 · Cited by 1
A Nearest Neighbour-Based Analysis to Identify Patients from Continuous Glucose Monitor Data
Mayo, M., & Yogarajan, V. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-14802-7_30 · Cited by 1
Modeling the SMBG measurement error
Vettoretti, M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00005-3 · Cited by 1
Thabit, H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221105283 · Cited by 1
Glycemia control using remote technologies
Суплотова, Л. А., & Alieva, O. O. (2023) · Meditsinskiy sovet = Medical Council · doi:10.21518/ms2023-157 · Cited by 1
Sensor mightier than pump—the jury is still out
Hovorka, R. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30235-8
Pathologic changes of pancreatic endothelial cells in Diabetic Rat
Wu, J., Wang, X., Feng, S. D., Li, Q., & Cai, F. (2017) · Journal of Clinical & Experimental Cardiology · doi:10.4172/2155-9880.1000552
Kontinuierliche Gewebezuckermessung beantragen – Schritt für Schritt
Schlüter, S. (2020) · Diabetologie und Stoffwechsel · doi:10.1055/a-0973-2077
Favero, S. D., Facchinetti, A., Sparacino, G., & Cobelli, C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816714-4.00011-9
Zelinska, P. B. N. B. (2020) · Ukrainian Journal of Pediatric Endocrinology · doi:10.30978/ujpe2020-3-26
Computer simulation model and automatic control of glucose clamp
Maghoul, P. (2021) · eScholarship@McGill (McGill) · doi:10.82308/47829
Muhs, A., Bobrowski, T., Lielpētere, A., & Schuhmann, W. W. (2022) · Angewandte Chemie · doi:10.1002/ange.202211559
Kontinuierliche Gewebe-Glukosemessung (CGM) und ambulantes Glukoseprofil (AGP)
Schäffler, A., & Petry, S. F. (2024) · Springer eBooks · doi:10.1007/978-3-662-68563-1_36
Continuous Tissue Glucose Monitoring (CGM) and Ambulatory Glucose Profile (AGP)
Schäffler, A., & Karrasch, T. (2024) · Springer eBooks · doi:10.1007/978-3-662-70260-4_36
Artificial intelligence/machine learning in the management of diabetes mellitus
Sonia, T. A., & Sharma, C. P. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-30272-5.00010-x · Cited by 1
Lindner, N., Kuwabara, A., & Holt, T. (2021) · Figshare · doi:10.6084/m9.figshare.14570084
Les cellules MAIT dans le diabète de type 1 chez l'homme
Nel, I. (2019) · theses.fr (ABES) · doi:10.70675/8eaa5bd8z1217z4729z8c2ezb385e0dbc1a9
Crowley, M., Newman, C., & Dunne, F. (2026) · BMC Medicine · doi:10.1186/s12916-026-04879-9
Tapsak, M. A., Talcott, M., THROWER, J., Goode, P. V., Routh, T. L., Tapsak, S. T., & Garcia, J. (2026) · Journal of Diabetes Research · doi:10.1155/jdr/8838426
In vitro and In vivo testing methods
Gao, W., Chen, W., & Rudramuni, K. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-36348-1.00006-2
Sugar slay: a gamified decision support ecosystem for type 1 diabetes
Rengarajan, S., Abrams, N., Tabar, A., Sundaram, H., Singh, K. P., & Chukoskie, L. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1779790
AI-Enhanced Wearable Glucose Sensors: From Intelligent Sensing to Closed-Loop Management of Diabetes
Sun, B., Ling, L. L., Talip, M. S. B. A., Zheng, S., Fu, Y., Ma, Q., Rezali, F. A. M., Cheng, C., Yilin, P., & Hatta, S. F. W. M. (2026) · ACS Sensors · doi:10.1021/acssensors.6c02471
Metadata
- Authors
- Bailey, T. S., Chang, A., & Christiansen, M.
- Affiliations
- AMCR Institute (US)
- John Muir Health (US)
- Diablo Clinical Research (US)
- Corresponding author
- Bailey, Timothy S.
- ORCID
- Bailey, Timothy S.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-11-03
- Volume
- 9
- Issue
- 2
- Pages
- 209-214
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC4604574
- OpenAlex
- W2165138941
- Cited by
- 168
- References
- 24
- Citations by year
- 2026: 7 · 2025: 7 · 2024: 9 · 2023: 7 · 2022: 7 · 2021: 14 · 2020: 15 · 2019: 23 · 2018: 21 · 2017: 30 · 2016: 18 · 2015: 10
- FWCI
- 15.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Dexcom
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, diabetes mellitus, clinical accuracy, hypoglycemia, self-monitoring of blood glucose, Clarke error grid, mean absolute relative difference, sensor reliability, insulin dose
- MeSH terms
- Adult, Aged, Aged, 80 and over, Algorithms, Blood Glucose, Diabetes Mellitus, Female, Humans, Male, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review