The Benefits, Limitations, and Cost-Effectiveness of Advanced Technologies in the Management of Patients With Diabetes Mellitus
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: Hypoglycemia mitigation is critical for appropriately managing patients with diabetes. Advanced technologies are becoming more prevalent in diabetes management, but their benefits have been primarily judged on the basis of hemoglobin A1c. A critical appraisal of the effectiveness and limitations of advanced technologies in reducing both A1c and hypoglycemia rates has not been previously performed. Methods: The cost of hypoglycemia was estimated using literature rates of hypoglycemia events resulting in hospitalizations. A literature search was conducted on the effect on A1c and hypoglycemia of advanced technologies. The cost-effectiveness of continuous subcutaneous insulin infusion (CSII) and real-time continuous glucose monitors (RT-CGM) was reviewed. Results: Severe hypoglycemia in insulin-using patients with diabetes costs $4.9-$12.7 billion. CSII reduces A1c in some but not all studies. CSII improves hypoglycemia in patients with high baseline rates. Bolus calculators improve A1c and improve the fear of hypoglycemia but not hypoglycemia rates. RT-CGM alone and when combined with CSII improve A1c with a neutral effect on hypoglycemia rates. Low-glucose threshold suspend systems reduce hypoglycemia with a neutral effect on A1c, and low-glucose predictive suspend systems reduce hypoglycemia with a small increase in plasma glucose levels. In short-term studies, artificial pancreas systems reduce both hypoglycemia rates and plasma glucose levels. CSII and RT-CGM are cost-effective technologies, but their wide adoption is limited by cost, psychosocial, and educational factors. Conclusions: Most currently available technologies improve A1c with a neutral or improved rate of hypoglycemia. Advanced technologies appear to be cost-effective in diabetes management, especially when including the underlying cost of hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389
Self-citationEffectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · cited 1×
“6% over 12 months compared to SMBG plus MDI in both adults and children.(52) Most of the benefit was in adults whose A1c decreased by 1%, while it decreased 0.”
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Threshold-based insulin-pump interruption for reduction of hypoglycemia
Bergenstal, R. M., Klonoff, D. C., Garg, S. K., Bode, B. W., Meredith, M., Slover, R. H., Ahmann, A. J., Welsh, J. B., Lee, S. W., & Kaufman, F. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1303576 · Cited by 652 · cited 1×
“Bergenstal and colleagues reported a significant reduction in rate and severity of hypoglycemia during a 3 months trial in adults using an LGTS system compared to those using SAP without an increase in A1c in either group.(53) There were important inclusion criteria for this study that inform us about who may benefit…”
MethodBraithwaite, R. S., Meltzer, D. O., King, J. T., Leslie, D., & Roberts, M. S. (2008) · Medical Care · doi:10.1097/mlr.0b013e31815c31a7 · Cited by 579 · cited 4×
“The published estimate for the total (direct and indirect) costs of diabetes is $245 billion a year as of 2012.16 This cost is 41% higher than 5 years earlier and now represents 20% of the health care expenditures in the United States.”
BackgroundInfluentialSeaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-4127 · Cited by 412
Self-citationLy, T. T., Nicholas, J. A., Retterath, A., Lim, E. M., Davis, E. A., & Jones, T. W. (2013) · JAMA · doi:10.1001/jama.2013.277818 · Cited by 411 · cited 1×
“5 per 100 patient-months in the LGTS system.(54) The severe hypoglycemia rate decreased from 2.”
BackgroundThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Prevalence of impaired awareness of hypoglycaemia in adults with Type 1 diabetes
Geddes, J., Schopman, J. E., Zammitt, N. N., & Frier, B. M. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02413.x · Cited by 387
Weinstock, R. S., Xing, D., Maahs, D. M., Michels, A., Rickels, M. R., Peters, A. L., Bergenstal, R. M., Harris, B., DuBose, S. N., Miller, K. M., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1589 · Cited by 338
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318 · cited 1×
“The penetration of device use in the United States is relatively small, ranging from 4% in adolescents to 21% in adults and it is discontinued by 41% of patients within 1 year.(49) There are many possible reasons for this not the least Figure 1.”
BackgroundHypoglycaemia in insulin‐treated Type 2 diabetes: frequency, symptoms and impaired awareness
Henderson, J. N., Allen, K. V., Deary, I. J., & Frier, B. M. (2003) · Diabetic Medicine · doi:10.1046/j.1464-5491.2003.01072.x · Cited by 287
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235 · cited 1×
“Chico et al were among the first investigators to demonstrate that hypoglycemia was often unrecognized in patients with type 2 diabetes whether on MDI or oral agents.(40) Approximately, 47% of their patients had hypoglycemia detected only with RT-CGM with 75% of those occurring during the night.”
BackgroundSchmidt, S., & Nørgaard, K. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532906 · Cited by 170
Bailey, T. S., Zisser, H. C., & Garg, S. K. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2007.0205 · Cited by 159 · cited 1×
“4% over a wide range of baseline A1cs without an increase in the rate of mild or severe hypoglycemia.(35) Whether or not RT-CGM improves the rate, severity and duration of hypoglycemia in patients with type 1 diabetes is not clear at this time.”
BackgroundSchopman, J. E., Geddes, J., & Frier, B. M. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.013 · Cited by 150
Lin, M. H., Connor, C. G., Ruedy, K. J., Beck, R. W., Kollman, C., Buckingham, B., Redondo, M. J., Schatz, D., Haro, H., Lee, J. M., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0132 · Cited by 81 · cited 1×
“In a study of factors that influence the prescription of CSII in the United States, the Pediatric Diabetes Consortium consisting of 7 independent clinics found that race, income, private insurance status, and family structure were all independent factors in whether or not a patient was started on an insulin pump withi…”
BackgroundThe Cost-Effectiveness of Real-Time Continuous Glucose Monitoring (RT-CGM) in Type 2 Diabetes
Fonda, S. J., Graham, C., Munakata, J., Powers, J. M., Price, D., & Vigersky, R. A. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816628547 · Cited by 81
Self-citationDavis, S. N., Horton, E. S., Battelino, T., Rubin, R. R., Schulman, K. A., & Tamborlane, W. V. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0145 · Cited by 40
Cited by
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Current and Emerging Technology for Continuous Glucose Monitoring
Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., & Flewitt, A. (2017) · Sensors · doi:10.3390/s17010182 · Cited by 291
Dunn, T. C., Xu, Y., Hayter, G., & Ajjan, R. A. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.12.015 · Cited by 239
Lin, M. H., Connor, C. G., Ruedy, K. J., Beck, R. W., Kollman, C., Buckingham, B., Redondo, M. J., Schatz, D., Haro, H., Lee, J. M., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0132 · Cited by 81
Zhang, W., Liu, Y., Sun, B., Shen, Y., Li, M., Peng, L., Duan, H., Su, X., Lu, S., Tian, X., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-03480-9 · Cited by 32
Metadata
- Authors
- Vigersky, R. A.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2015-01-02
- Volume
- 9
- Issue
- 2
- Pages
- 320-330
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2034536067
- Cited by
- 63
- References
- 23
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.