The Financial Impact of Inaccurate Blood Glucose Monitoring Systems
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Objective: An in silico study of type 1 diabetes (T1DM) patients utilized the UVA-PADOVA Type 1 Diabetes Simulator to assess the effect of patient blood glucose monitoring (BGM) system accuracy on clinical outcomes. We applied these findings to assess the financial impact of BGM system inaccuracy. Methods: The study included 43 BGM systems previously assessed for accuracy according to ISO 15197:2003 and ISO 15197:2013 criteria. Glycemic responses for the 100 in silico adult T1DM subjects were generated, using each meter. Changes in estimated HbA1c, severe hypoglycemic events, and health care resource utilization were computed for each simulation. The HbA1c Translator modeling approach was used to calculate the financial impact of these changes. Results: The average cost of inaccuracy associated with the entire group of BGM systems was £155 per patient year (PPY). The average additional cost of BGM systems not meeting the ISO 15197:2003 standard was an estimated £178 PPY more than an average system that fulfills the standard and an estimated £235 PPY more than an average system that appears to meet the ISO 15197:2013 standard. Conclusion: There is a clear relationship between BGM system accuracy and cost, with the highest costs being associated with BGM systems not meeting the ISO 15197:2003 standard. Lower costs are associated with systems meeting the ISO 15197:2013 system accuracy criteria. Using BGM systems that meet the system accuracy criteria of the ISO 15197:2013 standard can help reduce the clinical and financial consequences associated with inaccuracy of BGM devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Use of meters that meet the current ISO standard reduced the financial consequences of inaccuracy of glucose meters by more than £178 ($238) per patient-year.”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [128]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The second modeling study (128) demonstrated that meter inaccuracy increased the total cost of health care (including costs associated with hypoglycemic episodes), with the least accurate meters producing the greatest costs.”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [128]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Translating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Gold, A. E., Macleod, K. M., & Frier, B. M. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.697 · Cited by 810
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791 · cited 1×
“The UVA/PADOVA Type 1 Diabetes Simulator includes a population of 300 in silico subjects (100 adults, 100 adolescents, 100 children).(23) Each virtual subject is represented by a model parameter vector, which is randomly extracted from an appropriate joint parameter distribution.”
Self-citationHandelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.gl · Cited by 629
Handelsman, Y., Bloomgarden, Z. T., Grunberger, G., Umpierrez, G., Zimmerman, R. S., Bailey, T. S., Blonde, L., Bray, G. A., Cohen, A. J., Dagogo-Jack, S., et al. (2015) · Endocrine Practice · doi:10.4158/ep15672.glsuppl · Cited by 559
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545 · cited 1×
“Moreover, frequent severe hypoglycemic events (SHE) can lead to fear, which can become a key obstacle to intensifying therapy and/or adhering to prescribed insulin regimens,(12,13) resulting in poor metabolic control and subsequent health outcomes.(14) The financial consequences of severe hypoglycemia are equally sign…”
BackgroundHuang, E. S., Laiteerapong, N., Liu, J. Y., John, P. M., Moffet, H. H., & Karter, A. J. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2013.12956 · Cited by 501
Standards of Medical Care in Diabetes—2016: Summary of Revisions
(2016) · Diabetes Care · doi:10.2337/dc16-s003 · Cited by 448
Weinstock, R. S., Xing, D., Maahs, D. M., Michels, A., Rickels, M. R., Peters, A. L., Bergenstal, R. M., Harris, B., DuBose, S. N., Miller, K. M., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1589 · Cited by 338
Kovatchev, B. P., Cox, D. J., Gonder-Frederick, L. A., Young-Hyman, D., Schlundt, D., & Clarke, W. (1998) · Diabetes Care · doi:10.2337/diacare.21.11.1870 · Cited by 310
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237 · cited 2×
“For nine out of the 43 assessed systems, a complete system accuracy assessment could not be performed because of a sensitivity to blood oxygen.(24) For these systems, we used the existing data (180 instead of 200 measurements) and assumed the same performance for the missing data.”
MethodHypoglycemia: Still The Limiting Factor in the Glycemic Management of Diabetes
Cryer, P. E. (2008) · Endocrine Practice · doi:10.4158/ep.14.6.750 · Cited by 186
Counterregulatory hormone responses to hypoglycemia in the elderly patient with diabetes
Meneilly, G. S., Cheung, E., & Tuokko, H. (1994) · Diabetes · doi:10.2337/diab.43.3.403 · Cited by 167
Counterregulatory hormone responses to hypoglycemia in the elderly patient with diabetes
Meneilly, G. S., Cheung, E., & Tuokko, H. (1994) · Diabetes · doi:10.2337/diabetes.43.3.403 · Cited by 167
Costs of managing severe hypoglycaemia in three European countries
Hammer, M., Lammert, M., Mejías, S. M., Kern, W., & Frier, B. M. (2009) · Journal of Medical Economics · doi:10.3111/13696990903336597 · Cited by 152
MAUDE (Manufacturer and User Facility Device Experience)
(2017) · Cited by 139
Meneilly, G. S., & Tessier, D. (1995) · Diabetic Medicine · doi:10.1111/j.1464-5491.1995.tb00405.x · Cited by 132
Cariou, B., Fontaine, P., Eschwege, E., Lièvre, M., Gouet, D., Huet, D., Madani, S., Lavigne, S., & Charbonnel, B. (2015) · Diabetes & Metabolism · doi:10.1016/j.diabet.2014.10.007 · Cited by 129 · cited 1×
“A more recent report found a self-reported rate of severe hypoglycemia (defined as hypoglycemia resulting in seizure, loss of consciousness, or requiring third-party assistance due to weakness or confusion) of 31% in individuals with type 1 diabetes mellitus (T1DM) in the prior year.(5) It is well recognized that the…”
BackgroundFoos, V., Varol, N., Curtis, B. H., Boye, K. S., Grant, D., Palmer, J. L., & McEwan, P. (2015) · Journal of Medical Economics · doi:10.3111/13696998.2015.1006730 · Cited by 120
Breton, M. D., & Kovatchev, B. P. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400309 · Cited by 103 · cited 1×
“Whereas erroneously low blood glucose results can lead to extended hyperglycemia, resulting in elevated HbA1c levels and long-term adverse outcomes, erroneously high blood glucose results can lead to severe hypoglycemia, either by failing to detect hypoglycemia or by prompting the user to over-correct with insulin.(3)…”
BackgroundSelf-citationRoze, S., Valentine, W. J., Zakrzewska, K. E., & Palmer, A. J. (2005) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01576.x · Cited by 96
The underuse of insulin therapy in North America
Riddle, M. C. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.277 · Cited by 92
Baumstark, A., Pleus, S., Schmid, C., Link, M., Haug, C., & Freckmann, G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600511 · Cited by 90
Schütt, M., Fach, E. ‐., Seufert, J., Kerner, W., Lang, W., Zeyfang, A., Welp, R., Holl, R. W., & for the DPV Initiative and the German BMBF Competence Network Diabetes Mellitus (2012) · Diabetic Medicine · doi:10.1111/j.1464-5491.2012.03681.x · Cited by 84
Brazg, R. L., Klaff, L. J., & Parkin, C. G. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700117 · Cited by 68 · cited 1×
“In their 2013 study, Brazg and colleagues assessed the accuracy of 7 BGM systems, testing three test lots for each system.(27) The investigators observed that although three of the seven systems met ISO 15197:2003 criteria, only one system met the current ISO 15197:2013 criteria.”
BackgroundSelf-citationPerformance of Cleared Blood Glucose Monitors
Klonoff, D. C., & Prahalad, P. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815584797 · Cited by 59
Bolli, G. B. (1997) · PubMed · Cited by 46
Prediction and prevention of type 1 diabetes: what can be expected from genetics?
Jc, C., Lotton, C., & Bourgnères, P. (1997) · PubMed · Cited by 27
Clinical impact of blood glucose monitoring accuracy: an in-silico study
Campos-Náñez, E., Fortwaengler, K., & Breton, M. D. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817710474 · Cited by 22
Self-citationIn This Issue of Diabetes Care
(2016) · Diabetes Care · doi:10.2337/dc16-ti01 · Cited by 18
Fortwaengler, K., Parkin, C. G., Neeser, K., Neumann, M., & Mast, O. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816662048 · Cited by 13
Self-citationDiabetes and Medicare competitive bidding: the "perfect storm" for patient harm.
Davidson, J. A., & Parkin, C. (2016) · PubMed · Cited by 2
Self-citation
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Sacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility
Cobelli, C., & Kovatchev, B. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231195081 · Cited by 46
Juan, C. G., García, H. G., Ávila-Navarro, E., Bronchalo, E., Galiano, V., Moreno, Ó., Orozco‐Beltrán, D., & Sabater-Navarro, J. M. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02030-w · Cited by 36
Modeling of Diabetes and Its Clinical Impact
Fritzen, K., Heinemann, L., & Schnell, O. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818785642 · Cited by 34
Metadata
- Authors
- Fortwaengler, K., Campos-Náñez, E., Parkin, C. G., & Breton, M. D.
- Affiliations
- Roche Diabetes Care GmbH (Germany) (DE)
- University of Virginia (US)
- CGParkin Communications, Inc, Boulder City, NV, USA
- Corresponding author
- Parkin, Christopher G.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2017-09-26
- Volume
- 12
- Issue
- 2
- Pages
- 318-324
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC5851223
- OpenAlex
- W2758214362
- Semantic Scholar
- c533e7a456ce1d2e0e6af6e9e5b8df82332fbd29
- Cited by
- 17
- References
- 32
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 2
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- Roche Diabetes Care GmbH
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, blood glucose meter accuracy, blood glucose monitoring systems, financial impact, HbA1c, hypoglycemia, healthcare resource utilization, ISO 15197, computer simulation
- MeSH terms
- Data Accuracy, Adolescent, Adult, Child, Computer Simulation, Diabetes Mellitus, Type 1, Female, Humans, Hypoglycemia, Male, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.