Evaluation of a New Noninvasive Glucose Monitoring Device by Means of Standardized Meal Experiments
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Background: Frequent blood glucose readings are the most cumbersome aspect of diabetes treatment for many patients. The noninvasive TensorTip Combo Glucometer (CoG) component employs dedicated mathematical algorithms to analyze the collected signal and to predict tissue glucose at the fingertip. This study presents the performance of the CoG (the invasive and the noninvasive components) during a standardized meal experiment. Methods: Each of the 36 participants (18 females and males each, age: 49 ± 18 years, 14 healthy subjects, 6 type 1 and 16 type 2 patients) received a device for conducting calibration at home. Thereafter, they ingested a standardized meal. Blood glucose was assessed from capillary blood samples by means of the (non)invasive device, YSI Stat 2300 plus, Contour Next at time points –30, 0, 15, 30, 45, 60, 75, 90, 120, 150, and 180 minutes. Statistical analysis was performed by consensus error grid (CEG) and calculation of mean absolute relative difference (MARD) in comparison to YSI. Results: For the noninvasive (NI) CoG technology, 100% of the data pairs were found in CEG zones A (96.6%) and B (3.4%); 100% were seen in zone A for the invasive component and Contour Next. MARD was calculated to be 4.2% for Contour Next, 9.2% for the invasive component, and 14.4% for the NI component. Conclusions: After appropriate individual calibration of the NI technology, both the NI and the invasive CoG components reliably tracked tissue and blood glucose values, respectively. This may enable patients with diabetes to monitor their glucose levels frequently, reliably, and most of all pain-free.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
International Diabetes Federation 2017
Carracher, A. M., Marathe, P. H., & Close, K. L. (2018) · Journal of Diabetes · doi:10.1111/1753-0407.12644 · Cited by 13,418
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138
Gupta, A., & Uribarri, J. (2016) · Hormone Research in Paediatrics · doi:10.1159/000444053 · Cited by 4,006
The UK Prospective Diabetes Study (UKPDS): clinical and therapeutic implications for type 2 diabetes
King, P., Peacock, I., & Donnelly, R. (1999) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.1999.00092.x · Cited by 695
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595 · cited 1×
“It is therefore of particular importance to reduce the incidence of new diabetes manifestations by means of targeted prevention measures, and by employing measures to avoid disease progression until the development of diabetes complications.(2-4) One accepted measure is frequent glucose testing enabling targeted inter…”
Background
Research works printed but not linked: 1
- 23. Food and Drug Administration. FDA Self-monitoring blood glucose test systems for over-the-counter use. Guidance for industry and Food and Drug Administration staff; Available at: https://www.fda.gov/downloads/ucm380327.pdf. Accessed October 11, 2016. [Google Scholar]
Cited by
Villena Gonzales, W., Mobashsher, A., & Abbosh, A. (2019) · Sensors · doi:10.3390/s19040800 · Cited by 772
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
“In order to counter these effects, multi-technology and multi-sensors can be implemented and tailored to design a non-invasive sensor that is most sensitive to glucose molecules and independent of the many factors that contribute to false readings [65,147,166,167,211].”
BackgroundMethodSacks, D. B., Arnold, M. A., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvad080 · Cited by 208
A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring
Alsunaidi, B., Althobaiti, M., Tamal, M., Albaker, W. I., & Al-Naib, I. A. I. (2021) · Sensors · doi:10.3390/s21206820 · Cited by 127
Delbeck, S., Vahlsing, T., Leonhardt, S. K., Steiner, G. R., & Heise, H. M. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1395-x · Cited by 108
“for different individuals), while in the current stage (study 3 [64] and standardized meal study [23]), an extensive personal calibration of at least 25 invasive blood reference measure-”
BackgroundMethodShang, T., Zhang, J. Y., Thomas, A., Arnold, M. A., Vetter, B. N., Heinemann, L., & Klonoff, D. C. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211007212 · Cited by 71
Rayan, M. N., Reddy, N., Verma, N., & Dungan, K. M. (2026) · PubMed · Cited by 110
Improving patient self-care using diabetes technologies
Alcántara-Aragón, V. (2019) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/2042018818824215 · Cited by 63
Device and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55
Todaro, B., Begarani, F., Sartori, F., & Luin, S. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.994272 · Cited by 43
Patent analysis of digital sensors for continuous glucose monitoring
Litvinova, O., Eitenberger, M., Bilir, A., Yeung, A. W. K., Parvanov, E. D., MohanaSundaram, A., Horbańczuk, J. O., Atanasov, A. G., & Willschke, H. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1205903 · Cited by 42
“The authors conclude that the measurements were reliable with the Combo glucometer (79).”
MethodArtificial intelligence-driven transformations in diabetes care: a comprehensive literature review
Iftikhar, M., Saqib, M., Qayyum, S. N., Asmat, R., Mumtaz, H., Rehan, M., Ullah, I., Uddin, I., Noori, S., Khan, M., et al. (2024) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000002369 · Cited by 39
“[16] evaluated the accuracy of TensorTip Combo Glucometer (CoG), which has an invasive component using test strips and a noninvasive component to predict glucose levels from fi ngertip tissues.”
MethodVahlsing, T., Delbeck, S., Leonhardt, S., & Heise, H. M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818798347 · Cited by 28
Noninvasive Glucose Sensing In Vivo
Leung, H. M. C., Forlenza, G. P., Prioleau, T., & Zhou, X. (2023) · Sensors · doi:10.3390/s23167057 · Cited by 36
System Accuracy Assessment of a Combined Invasive and Noninvasive Glucometer
Pfützner, A., Demircik, F., Pfützner, J. W., Kessler, K., Strobl, S., Spatz, J., Pfützner, A. H., & Lier, A. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883306 · Cited by 16
“, Cesarea, Israel) and tested in clinical trials.(10,11) This present study was performed to determine the system accuracy of the invasive device component by means of a study protocol following the ISO15197:2015 standard.”
MethodSelf-citationBlood glucose monitoring techniques: recent advances, challenges and future perspectives
Gamessa, T. W., Suman, D., & Tadesse, Z. K. (2018) · International Journal of Advanced Technology and Engineering Exploration · doi:10.19101/ijatee.2018.546008 · Cited by 20
“The post-market evaluation indicated high correlation with reference to invasive devices [62, 63].”
BackgroundPhan, Q.-H., Jian, T.-H., Huang, Y.-R., Lai, Y.-R., Xiao, W.-Z., & Chen, S.-W. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106268 · Cited by 14
Non-Invasive Blood Glucose Sensor: A Feasibility Study
Albalat, Á. L., Alaman, M. B. S., Diez, M. C. D., Martínez-Millana, A., & Traver, V. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857261 · Cited by 13
Phan, Q.-H., Han, C.-Y., Lien, C.-H., & Pham, T.-T.-H. (2021) · Sensors · doi:10.3390/s21103442 · Cited by 11
“4 mg/dL [6], and the FreeStyle Libre Flash system from Abbot Inc.”
MethodA Review of Minimally and Non-invasive Glucose Monitoring Techniques, Devices and Sensors
Nooshnab, M., Naghib, S. M., Rahmanifard, R., & Khakpour, E. (2024) · Current Analytical Chemistry · doi:10.2174/0115734110290007240202154817 · Cited by 12
Kumar, A., & Goel, S. (2025) · Lab on a Chip · doi:10.1039/d5lc00275c · Cited by 10
Chen, H., Yao, Q., Dong, Y., Tang, Z., Li, R., Cai, B., Wang, R., & Chen, Q. (2019) · Primary care diabetes · doi:10.1016/j.pcd.2018.12.010 · Cited by 10
IoT Based Healthcare with a Non-Invasive Diabetes Testing System
Rahman, B., Saha, S., Iqbal, K. S., Ahmad, R., Mahmood, A., Uddin, M. R., & Hasan, M. (2023) · International Conference on Computer and Information Technology (ICCIT) · doi:10.1109/iccit60459.2023.10441620 · Cited by 7
“Molecular vibrations and bond rotation inside molecules absorb and scatter wavelengths from 780 to 2500 nm, enabling near-infrared spectroscopy (NIRS) [11].”
BackgroundNon-invasive biomedical analysis: recent advances, challenges, and future perspectives
Cirovic, S. (2024) · doi:10.24834/isbn.9789178774562 · Cited by 11
Near-Infrared Spectroscopy for Noninvasive Measurement of Blood Glucose: Problems, Progress, Tasks
Витольдович, П. К., Mikhailov, M. O., Litinskaia, E. L., & Polyakova, E. A. (2022) · Biomedical Engineering · doi:10.1007/s10527-022-10168-5 · Cited by 6
Mosli, H. H., & Madani, B. (2021) · International Journal of Medicine in Developing Countries · doi:10.24911/ijmdc.51-1611360395 · Cited by 7
Measurement of Continuous Glucose using Antenna as Sensor in Non Invasive Method
J, J. K. S., Bennet, M. A., Shanker, N. R., & Pravin, P. (2025) · International Conference on Ubiquitous Computing and Intelligent Information Systems (ICUIS) · doi:10.1109/icuis67429.2025.11380674 · Cited by 3
“It is possible to evaluate glucose levels non-invasively by sampling tear fluid [12], [13].”
Exploring Sensing Technologies for Tracking Healthy Eating Behaviors: Systematic Review
Ataguba, G., & Orji, R. (2025) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2025.2555632 · Cited by 2
“This is followed by Japan (Chinju et al., 2024; Kadomura et al., 2013, Kadomura et al., 2014; Kuramoto et al., 2021; Nakaoka et al., 2021) and Germany (Pf € utzner et al., 2018; Schmalbach et al., 2021).”
InfluentialNew Paradigm of Personalized Glycemic Control Using Glucose Temporal Density Histograms
Trahtemberg, U., Hallas, T., Segman, Y., Sheiman, E., Shasha, M., Nissim, K., & Segman, Y. J. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818821423 · Cited by 1
Wearable Technologies for Glucose Monitoring: A Systematic Mapping Study of Publication Trends
Iyawa, G. E., Velusamy, V., & Palanisamy, S. (2019) · Advances in web technologies and engineering book series · doi:10.4018/978-1-5225-9246-4.ch007 · Cited by 3
Modern Methods Of Glucose Monitoring In The Context Of Physical Activity - Review Study
Jędrasek, A., Jędrasek, T. W., Pogoda, J., Piotrowski, J., Hądzlik, I., Biały-Karbowniczek, J., Słychan, K., Łuczak, B., Bulska, K., & Sławek, K. (2024) · Quality in Sport · doi:10.12775/qs.2024.19.53812
Metadata
- Authors
- Pfützner, A., Strobl, S., Demircik, F., Redert, L., Pfützner, J., Pfützner, A. H., & Lier, A.
- Affiliations
- TH Bingen University of Applied Sciences (DE)
- Pfützner Science & Health Institute, Mainz, Germany
- Corresponding author
- Pfützner, Andreas
- ORCID
- Pfützner, Andreas
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2018-02-16
- Volume
- 12
- Issue
- 6
- Pages
- 1178-1183
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6232728
- OpenAlex
- W2790254504
- Cited by
- 33
- References
- 28
- Citations by year
- 2025: 3 · 2024: 4 · 2023: 5 · 2022: 3 · 2021: 4 · 2020: 3 · 2019: 7 · 2018: 4
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- non-invasive glucose monitoring, type 1 diabetes, type 2 diabetes, blood glucose, mean absolute relative difference
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Eating, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Reference Standards, Blood Glucose Self-Monitoring, Postprandial Period, Young Adult, Meals
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.