The Relationships Between Time in Range, Hyperglycemia Metrics, and HbA1c
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: As the use of continuous glucose monitoring (CGM) increases, there is a need to better understand key metrics of time in range 70-180 mg/dL (TIR 70-180 ) and hyperglycemia and how they relate to hemoglobin A1c (A1C). Methods: Analyses were conducted utilizing datasets from four randomized trials encompassing 545 adults with type 1 diabetes (T1D) who had central-laboratory measurements of A1C. CGM metrics were calculated and compared with each other and A1C cross-sectionally and longitudinally. Results: Correlations among CGM metrics (TIR 70-180 , time >180 mg/dL, time >250 mg/dL, mean glucose, area under the curve above 180 mg/dL, high blood glucose index, and time in range 70-140 mg/dL) were typically 0.90 or greater. Correlations of each metric with A1C were lower (absolute values 0.66-0.71 at baseline and 0.73-0.78 at month 6). For a given TIR 70-180 percentage, there was a wide range of possible A1C levels that could be associated with that TIR 70-180 level. On average, a TIR 70-180 of 70% and 50% corresponded with an A1C of approximately 7% and 8%, respectively. There also was considerable spread of change in A1C for a given change in TIR 70-180 , and vice versa. An increase in TIR 70-180 of 10% (2.4 hours per day) corresponded to a decrease in A1C of 0.6%, on average. Conclusions: In T1D, CGM measures reflecting hyperglycemia (including TIR and mean glucose) are highly correlated with each other but only moderately correlated with A1C. For a given TIR or change in TIR there is a wide range of possible corresponding A1C values.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Use of structured BGM data to adjust medications is associated with greater A1C decreases than unstructured BGM.151,152”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [152]
In the citing paper
“Relationships between time in target range and A1C (25; 26) and number of severe and non-severe hypoglycemic events (27-31) have also been observed.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“Importantly, as demonstrated by Beck et al. (25), Vigersky et al. (26) and Feig et al. (47), even small, incremental improvements yield significant glycemic benefits.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
11 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationTranslating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationValidation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Self-citationGlucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationHeinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Self-citationThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Research works printed but not linked: 1
- Peters AL, Paper presented at: European Association for the Study of Diabetes Meeting
Cited by
Items 301–400 of 475
Siemens, R. L. (2022) · Clinical Diabetes · doi:10.2337/cd21-0088 · Cited by 6
Glutamic acid decarboxylase immunotherapy for type 1 diabetes
Ludvigsson, J. (2022) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000748 · Cited by 4
“Beck RW, Bergenstal RM, Cheng P, et al. The relationships between time in range, hyperglycemia metrics, and HbA1c.”
BackgroundInfluentialUemura, F., Okada, Y., Torimoto, K., & Tanaka, Y. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0194 · Cited by 4
Medical Certification of Pilots Through the Insulin-Treated Diabetes Mellitus Protocol at the FAA
Stanwyck, L. K., DeVoll, J. R., Pastore, J., Gamble, Z., Poe, A., & Gui, G. V. (2022) · Aerospace Medicine and Human Performance · doi:10.3357/amhp.6107.2022 · Cited by 5
Continuous Glucose Monitoring vs. Capillary Blood Glucose in Hospitalized Type 2 Diabetes Patients
Veríssimo, D., Vinhais, J., Ivo, C., Martins, A. C., Silva, J. N. E., Passos, D., Lopes, L., de Castro, J. J., & Marcelino, M. (2023) · Cureus · doi:10.7759/cureus.43832 · Cited by 7
“CGM has been extensively studied in outpatient settings and has shown improved glycemic control by reducing hypoglycemia and increasing time-in-range in both type 1 and type 2 diabetes [6-9].”
BackgroundMonitoring of paediatric type 1 diabetes
Marks, B. E., & Wolfsdorf, J. I. (2022) · Current Opinion in Pediatrics · doi:10.1097/mop.0000000000001136 · Cited by 6
Ehrmann, D., Ruch, B., Mitter, M., Kober, J., Hermanns, N., Schäfer, V., Kulzer, B., & Silbermann, S. (2025) · Journal of Medical Internet Research · doi:10.2196/68933 · Cited by 3
“For instance, people with type 2 diabetes and a baseline eHbA 1c >8.5% experienced a reduction in mean blood glucose of approximately 100 mg/dL compared with the month before app use, corresponding to an eHbA 1c decrease of about 3.48% [14,16].”
InfluentialLara-Gálvez, D., Rubio-Almanza, M., Aparicio-Ródenas, Y., Sanchis-Pascual, D., Masdeu-López-Cerón, P., Pérez-Cervantes, V., & Merino-Torres, J. F. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm15010034 · Cited by 6
“Because inpatient TIR has been linked to clinically relevant outcomes—including infection rates, hemodynamic stability, and length of stay [15,27,28]— this review examines the extent to which CGM improves TIR, decreases hyperglycemia and hypoglycemia, and optimizes overall glycemic control in…”
Meulemeester, J. D., Fiorentino, F., Picado, N., Visser, M. M., Keymeulen, B., Block, C. E. M. D., Huffel, L. V., Taes, Y., Ballaux, D., Spincemaille, K., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251408041 · Cited by 3
“This conversion is based on data from Beck et al., 51 (cid:1) FIG.”
Chen, L., Zhang, L., & Zhou, N. (2026) · International Urology and Nephrology · doi:10.1007/s11255-026-05210-4 · Cited by 3
“Among CGM-derived metrics, time in range (TIR)—the proportion of time spent with glucose levels between 3.9 and 10.0 mmol/L (70–180 mg/ dL)—has emerged as a robust indicator of glycemic control [9].”
InfluentialLima, R. A. D., Fernandes, D. R., Garcia, R. A. C., Carvalho, L. A. D. R., Silveira, R. C. D. C. P., & Teixeira, C. R. D. S. (2023) · Revista Latino-Americana de Enfermagem · doi:10.1590/1518-8345.6655.4088 · Cited by 5
Q-Score Complements the Time in Range in the Evaluation of Short-Term Glycemic Control
Augstein, P., Heinke, P., Nowak, A., Salzsieder, E., & Kerner, W. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241246209 · Cited by 3
“The MSG, which is also a component of the Q-Score, reflects hyperglycemia 30 and accounts for the strong correlation between the Q-Score and GMI.”
Improving Diabetic Care Through Education and Innovation
Williamson, R. J., Powell, R., & Shepherd, A. K. (2024) · Journal of Doctoral Nursing Practice · doi:10.1891/jdnp-2023-0060 · Cited by 3
Bevan, A. M., Ellis, G., Eskandarian, M., & Garrisi, D. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241301800 · Cited by 3
Moreno-Fernández, J., Beato-Víbora, P. I., Olvera, P., García-Seco, J. A., Gallego-Gamero, F., Herrera, M. T., & Muñoz‐Rodríguez, J. R. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.109093 · Cited by 3
Medina, A. M. G., Soto-Chávez, M. J., Carrillo, D. C. H., Sánchez, J. C. S., González, J. A. G., Grassi, B. A., & Múñoz, Ó. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110713 · Cited by 5
Baboun, D., Solano, N., Toro, V. D., Alvarez-Salvat, R., Granados, A., & Carrillo‐Iregui, A. (2023) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2023-0334 · Cited by 4
“Our study provided further support for previous research [21 – 23] by con fi rming the existence of an inverse association between HbA 1c levels and TIR.”
ResultKowalczyk, E., & Szypowska, A. (2024) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-024-01310-y · Cited by 3
“TIR and HbA1c levels are correlated; each 10% increase in TIR is associated with a 0.6–0.8% decrease in HbA1c levels [8, 12, 13].”
InfluentialParimi, V., Elsner, A. E., Gast, T. J., Chen, Z., Baskaran, K., Alhamami, M. A., Litvin, T. V., Ozawa, G. Y., & Cuadros, J. A. (2024) · Optometry and Vision Science · doi:10.1097/opx.0000000000002096 · Cited by 3
Technological Innovations in Type 1 Diabetes Mellitus Management: A Narrative Review
Gunatilake, S. S. C. (2024) · Sri Lanka Journal of Diabetes Endocrinology and Metabolism · doi:10.4038/sjdem.v15i1.7534 · Cited by 5
O’Donnell, H. K., & Driscoll, K. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-816000-8.00003-7 · Cited by 5
Interpreting the recent consensus on time in range for interstitial glucose right – Or wrong?
Eckstein, M. L., Knoll, L., Pöttler, T., Hochfellner, D. A., Müller, A., Sourij, H., Moser, O., & Mader, J. K. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108106 · Cited by 3
Predictive low-glucose suspend system and glycemic variability
Evin, F., Ata, A., Er, E., Demir, G., Çetin, H., Altınok, Y. A., Özen, S., Darcan, Ş., & Gökşen, D. (2021) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-021-00957-1 · Cited by 3
Hybrid Closed-Loop Insulin Delivery Systems for People With Type 1 Diabetes
Service, C. H. T. A. (2021) · Canadian Journal of Health Technologies · doi:10.51731/cjht.2021.50 · Cited by 4
Sifri, S. A., Alshaikh, A., Bin-Abbas, B. S., Sheshah, E., Sabaan, F. S. A., Aldawish, M., Al-Dubayee, M., Alzaman, N. S., Aldahash, R., ALZAHRANI, S. H., et al. (2021) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2021.128028 · Cited by 4
Type 1 Diabetes in Children and Adolescents
Hu, P., Name, M. A. V., Stephenson, K., Sikes, K. A., & Tamborlane, W. V. (2024) · Springer eBooks · doi:10.1007/978-3-031-66296-6_30 · Cited by 3
Tanaka, K., Okada, Y., Uemura, F., & Tanaka, Y. (2024) · Scientific Reports · doi:10.1038/s41598-024-63678-5 · Cited by 4
“Furthermore, maintaining TIR > 70% was recommended as a target for managing type 2 diabetes to prevent microangi-opathies, based on research demonstrating that a TIR of 70% corresponds to an HbA1c level of approximately 7% 15 .”
BackgroundZhong, N., Zhang, A., Chen, J., Hu, Z., Nie, R., Huang, J., Wu, M., & Pan, H. (2025) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s542547 · Cited by 2
“17 Therefore, it is clinically important to include TIR in the glycemic management goal (recommended >70%).”
Roy, M., Singh, M., & Jamwal, M. (2025) · International Journal of Pharmaceutical and Healthcare Marketing · doi:10.1108/ijphm-10-2024-0111 · Cited by 2
Kim, J. Y., Kim, N. H., Kwak, S. H., Jung, C. H., Kang, E. S., Moon, J. S., Moon, S. J., Kwon, S. Y., Yoo, J. H., Kim, Y., et al. (2025) · Endocrinology and Metabolism · doi:10.3803/enm.2025.2579 · Cited by 3
“…reasons: (1) a 5% improvement in TIR, which is considered clinically meaningful [17-19], corresponds approximately to a 0.3% change in HbA1c level [20]; and (2) the U.S. Food and Drug Administration and the European Medicines Agency have suggested a non-inferiority margin of 0.3% for HbA1c…”
InfluentialGarcía-Sáenz, M. R., Gómez-Romero, O. J., Espinosa-Cárdenas, E., Ramírez‐Rentería, C., Doval-Caballero, J. L. E., Uribe-Cortés, D., & Ferreira‐Hermosillo, A. (2026) · Life · doi:10.3390/life16030377 · Cited by 3
Variation of glucose time in range in type 1 diabetes
Hansen, K. W., & Bibby, B. M. (2022) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.379 · Cited by 2
Krajnc, M., & Tramšek, N. A. K. (2023) · European journal of medical research · doi:10.1186/s40001-023-01081-y · Cited by 2
Citro, F., Bertolotto, A., Aragona, M., Nicolì, F., & Bianchi, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0133 · Cited by 2
Shiose, K., Tomiga-Takae, R., Hatamoto, Y., Higaki, Y., & Uehara, Y. (2023) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2023.06.042 · Cited by 2
de Oliveira, C. P., Dellva, M. A., Bue‐Valleskey, J. M., Chang, A. M., & Liao, B. (2023) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2023.108648 · Cited by 4
Time in range prediction using the experimental mobile application in type 1 diabetes
Русанов, А. Н., & Родионова, Т. И. (2024) · Diabetes Mellitus · doi:10.14341/dm13111 · Cited by 2
Alazmi, A. A., Brema, I. A., ALZAHRANI, S. H., & Almehthel, M. S. (2024) · Cureus · doi:10.7759/cureus.63947 · Cited by 3
“In the present study, we report a significant correlation between Hb1Ac and TIR, which is consistent with previously published studies [23,24].”
ResultInfluentialBest practices and rationale for expanding Medicaid access to continuous glucose monitoring
King, C. A., & Lilly, A. N. (2024) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2024.30.10-b.s40 · Cited by 2
Diagnostik, Therapie und Verlaufskontrolle des Typ-1-Diabetes mellitus im Kindes- und Jugendalter
Holder, M., Ziegler, R., Kamrath, C., Lange, K., & Kummer, S. (2024) · Diabetologie und Stoffwechsel · doi:10.1055/a-2374-0813 · Cited by 2
Amigo, J. G. D. B., García, A. G., Fernández, P. D., Llamas, M. F., Bravo, M. L. T., Jiménez, J. M., & Lozano, M. F. (2020) · Anales de Pediatría · doi:10.1016/j.anpedi.2020.11.002 · Cited by 2
Pujante, P., Felgueroso, C. A., Ares, J., Morales-Sánchez, P., Lambert, C., Escobedo, R. R., Rodríguez‐Rodero, S., Delgado, E., & Torre, E. L. M. (2022) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2021.10.008 · Cited by 3
Mader, J. K., Gölz, S., Bilz, S., Bramlage, P., & Danne, T. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2022-002898 · Cited by 2
Pengendalian Gula Darah pada DM Tipe 2 dengan Pemeriksaan HbA1c di Rumah Sakit
Lestari, W. S., Fitriana, E., Jumaisa, A., Siregar, S., & Ujiani, S. (2022) · Journal of Telenursing (JOTING) · doi:10.31539/joting.v4i2.4391 · Cited by 5
Trends in Time in Range–Related Publications and Clinical Trials: A Bibliometric Review
Patel, P. M., Abaniel, R. M., Dogra, N., Lo, C. B., Frazzitta, M. A., & Virdi, N. S. (2023) · Diabetes Spectrum · doi:10.2337/ds22-0085 · Cited by 4
Lima, R. A. D., Fernandes, D. R., Garcia, R. A. C., Carvalho, L. A. D. R., Silveira, R. C. D. C. P., & Teixeira, C. R. D. S. (2023) · Revista Latino-Americana de Enfermagem · doi:10.1590/1518-8345.6655.4089 · Cited by 3
Lai, Y., Chiu, W.-C., Cheng, B., Yu, I., Lin, T. ‐., Chiang, H., Kuo, C. A., & Lu, C. (2025) · Journal of Diabetes Investigation · doi:10.1111/jdi.70079 · Cited by 5
“Previous studies have found a signi fi cant correlation between HbA1c and TIR 9 .”
Newson, R. S., Artime, E., Bower, J. K., Spaepen, E., Liao, B., Bhattacharya, I., & Battelino, T. (2025) · Patient Preference and Adherence · doi:10.2147/ppa.s511332 · Cited by 4
Takehisa, Y., & Bando, H. (2020) · doi:10.36502/2020/droa.6174 · Cited by 3
“correlation has been suggested between TIR and HbA1c value, such as a goal of 70% TIR aligning with an HbA1c of 7% from two prospective investigations [7,40].”
BackgroundGlycemic Variability in Type 1 Diabetes Mellitus Saudis Using Ambulatory Glucose Profile
Alzahrani, B. S., ALZAHRANI, S. H., Almalki, M., Elabd, S. S., Khan, S. A., Buhary, B. M., Aljuhani, N., & Jammah, A. A. (2021) · Clinical Medicine Insights Endocrinology and Diabetes · doi:10.1177/11795514211013789 · Cited by 2
Time-in-range: a promising glycemic control metric for bariatric surgery
Kang, M., & Li, W. (2022) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2022.08.002 · Cited by 2
The Relationship Between Glycated Hemoglobin and Time in Range in a Pediatric Population
Vandenbempt, M., Matheussen, H., Charleer, S., Rochtus, A. M., & Casteels, K. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0482 · Cited by 3
“18 19–21 Therefore, we conducted this large retrospective study on the relationship between HbA1c and TIR during the preceding 2, 4, and 12 weeks in a pediatric population with T1D.”
Spitzer, A. I., Rodbard, H. W., Iqbal, S. U., Nakazawa, M., DiGiorgi, M., & Winston, R. (2024) · The Journal of Arthroplasty · doi:10.1016/j.arth.2024.05.055 · Cited by 3
Glycemic variability and diabetic cardiac autonomic neuropathy
Serhiyenko, A. A., Tsaryk, T. V., Pavlovskiy, Y., & Serhiyenko, V. A. (2024) · INTERNATIONAL JOURNAL OF ENDOCRINOLOGY (Ukraine) · doi:10.22141/2224-0721.20.4.2024.1398 · Cited by 1
Gómez, A. M., Chicue, M.-P., Henao, D. C., & Múñoz, Ó. (2025) · Journal of International Medical Research · doi:10.1177/03000605251382375 · Cited by 1
PTH variability is associated with increased risk of mortality in Japanese hemodialysis patients
Kato, T., Yoshida, K., Abe, M., Yamashita, M., Kobayashi, K., Saito, T., Takezaki, T., Kato, N., Mizobuchi, M., Koiwa, F., et al. (2025) · Clinical and Experimental Nephrology · doi:10.1007/s10157-025-02777-7 · Cited by 1
“Among them, the time-in-range of blood glucose levels is considered an important indicator in the management of diabetes [31].”
Chatty, P., Gera, S., Rearson, A., Mountain, J. N., Alicea-Trelles, N., Gallop, R., & Marks, B. E. (2025) · Diabetes Care · doi:10.2337/dc25-2082 · Cited by 1
Benhamou, P., Vesin, A., Reynaud, L., & Chatel, B. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251404493 · Cited by 1
Davis, G. M., Forlenza, G. P., Gehr, B., Pemberton, J. S., Penfornis, A., Do, D., Huyett, L. M., & Ly, T. T. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113450 · Cited by 2
Ni, J., Chen, L., Su, H., Guo, J., Wang, C., Wang, Y., Lu, J., Zhou, J., Xia, T., & Jiang, F. (2026) · Journal of Diabetes · doi:10.1111/1753-0407.70260 · Cited by 1
Gupta, V. (2025) · Cureus · doi:10.7759/cureus.82061 · Cited by 3
“A study by Beck et al. observed that a 10% increase in TIR70-180 (approximately 2.4 hours per day) was associated with an average decrease in HbA1c of 0.6%, highlighting the significant role of TIR in influencing HbA1c levels [33].”
InfluentialXu, C., Dai, W., Liu, Y., Zhang, R., Shi, E., Shan, X., & Cao, Y. (2025) · International Journal of General Medicine · doi:10.2147/ijgm.s498567 · Cited by 1
“21 Hyperglycemia can induce mitochondria to produce a large amount of superoxide including reactive oxygen species, causing oxidative stress, thereby activating the production of advanced glycation end products and protein kinase C in cells, and also increasing the flux of key pathways such as…”
Okuno, T., Macwan, S. A., Norman, G. J., Miller, D. R., Reaven, P. D., & Zhou, J. Y. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261416922 · Cited by 3
Li, H., Tao, S., Zhou, X., Yan, R., Yu, B., Luo, Y., Zhang, P., Kong, X., & Ma, J. (2026) · Scientific Reports · doi:10.1038/s41598-026-48843-2 · Cited by 1
Benedict, Á., Hankosky, E. R., Marczell, K., Chen, J., Klein, D. J., Caro, J. J., Bae, J. P., & Benneyworth, B. D. (2022) · PharmacoEconomics · doi:10.1007/s40273-022-01148-4 · Cited by 1
Defining Outcomes for β-Cell Replacement Therapy
Rickels, M. R. (2023) · Springer eBooks · doi:10.1007/978-3-031-20999-4_65 · Cited by 1
Schroeder, A. E., Rosenkranz, R. R., Yarrow, L., Haub, M. D., & Rosenkranz, S. K. (2023) · Sports · doi:10.3390/sports11110214 · Cited by 3
“Alterna-tively, TIR provides details about daily glycemic variations and may be a better indicator of overall glycemic control than HbA1c [48 While current ADA guidelines recommend aiming for > 70% TIR [33], a recent survey of 1026 patients with T1DM revealed that fewer than 20% of respondents…”
BackgroundOraibi, O., Somaili, M., Elmakki, E. E., Alqassimi, S., Madkhali, M. A., Mohrag, M., Abusageah, F., Alhazmi, M. K., Alfaifi, S. M., Ageeli, R., et al. (2023) · Endocrine Metabolic & Immune Disorders - Drug Targets · doi:10.2174/0118715303263019231029163336 · Cited by 1
Lima, R. A. D., Fernandes, D. R., Garcia, R. A. C., Carvalho, L. A. D. R., Silveira, R. C. D. C. P., & Teixeira, C. R. D. S. (2023) · Revista Latino-Americana de Enfermagem · doi:10.1590/1518-8345.6655.4090
Sebastián‐Valles, F., Martín, J. A. A., Alfonso, J. M., Jiménez‐Díaz, J., Alday, I. H., Navas-Moreno, V., Joya, T. A., García, M., Gómez, G. L. R., Hierro, J. G., et al. (2024) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70020 · Cited by 1
Current state of continuous glucose monitoring. Minirewiew
Friedecky, B., & Kratochvíla, J. (2020) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2020.023 · Cited by 2
Ma, W., Li, J., Shao, X., Yin, X., Xie, C., Wang, F., & Li, Y. (2025) · Open Medicine · doi:10.1515/med-2025-1158 · Cited by 2
“Furthermore, each 10% increase in TIR is associated with an approximate 0.5% improvement in HbA1c levels [16].”
InfluentialAchievement of time in range goals among patients with diabetes using continuous glucose monitoring
Azizi, F., Diehl, K., Enser, L., & Heacock, S. (2025) · Journal of the American Pharmacists Association · doi:10.1016/j.japh.2025.102924 · Cited by 1
Picard, S. (2020) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2020.06.021 · Cited by 1
“Il a d'ailleurs été montré dans une étude en vie réelle que la fréquence des hypoglycémies sévères était doublée chez les patients dont l'HbA1c était 9 % versus < 7 % [10].”
BackgroundInfluentialSeibold, A. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0674 · Cited by 1
“This study identified adults with T1D, who were Free-Style Libre system users for a minimum of 1 year, who had initiated a switch to the G4 system due to poor glucose control as defined by at least one severe hypoglycemic event in the previous 12 months or had impaired awareness of hypoglycemia (Gold/Clarke score of ‡ 4…”
InfluentialThe role Time in range depending on the method of assessing glycemic control in diabetes: A review
Суплотова, Л. А., Сергеевна, С. А., & Сергеевна, Д. Т. (2022) · Consilium Medicum · doi:10.26442/20751753.2022.4.201674 · Cited by 1
“Увеличение TIR на 10% (2,4 ч в день) соответствовало снижению HbA1c примерно на 0,5% (5,0 ммоль/л) [39].”
D’Agostin, M., Tumminelli, C., Grigoletto, V., Tornese, G., Barbi, E., & Faleschini, E. (2022) · Medico e Bambino · doi:10.53126/meb41505 · Cited by 1
Hayek, A. A., Alzahrani, W. M., Sobki, S. H., Alsaeed, A. H., & Dawish, M. A. A. (2023) · Cureus · doi:10.7759/cureus.33416 · Cited by 4
“5% drop in HbA1c with every 10% increase in TIR [37,38]; this is in line with our findings.”
ResultCutruzzolà, A., Irace, C., Parise, M., Fiorentino, R., Barone, M., & Gnasso, A. (2020) · Research Square · doi:10.21203/rs.3.rs-27649/v1 · Cited by 1
“Two recent papers have described a close relationship between TIR and glycated hemoglobin (HbA1c) using different data-sets from observational studies and randomized controlled trials (18, 19).”
MethodMonnier, L., Colette, C., & Owens, D. R. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0286 · Cited by 1
Ruiz Gracia, T., Nattero-Chávez, L., Arranz Martín, A., de la Calle de la Villa, E., Lorenzo Moñino, M., Bayona Cebada, A., Corral, M. I., Quintero Tobar, A., Lahera Vargas, M., Jiménez Blanco, S., et al. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113505
Yanagimachi, M., Fujita, T., Yamaichi, M., Matsumoto, A., NAKAYAMA, H., Nakamura, R., Sato, E., Tando, Y., Daimon, M., & Nakamura, T. (2020) · Suizo · doi:10.2958/suizo.35.145
Préau, Y., Armand, M., Galie, S., Schaepelynck, P., & Raccah, D. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0087
“11 The nondecrease in HbA1c for the other patients despite an increase in TIR could be due to red blood cell lifespan or other factors influencing HbA1c levels unrelated to the degree of glycemia (chronic renal disease, hemoglobinopathies or hemoglobin variants, hypertriglyceridemia, and…”
New Trends: Time in Range and the Use of Continuous Glucose Monitoring Devices on Glycemic Control
Souza, K. L. V. D., Rassi, M. M. B., de Sá, D. A. R., Bussuan, R. M., Rodrigues, L. C. D. S., & Arbex, A. K. (2021) · European Journal of Medical and Health Sciences · doi:10.24018/ejmed.2021.3.1.491 · Cited by 1
Methoden der Stoffwechselkontrolle – HbA1c versus „time in range“
Freckmann, G., Buck, S., Waldenmaier, D., & Haug, C. (2021) · Der Diabetologe · doi:10.1007/s11428-021-00730-2
McKee, A. M., & McGill, J. B. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab220
Petrovski, G., Campbell, J., Khalaf, F. A., & Hussain, K. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0179
Placement of insulin pump by telemedicine
Foglia, A. (2020) · The Journal of AMD · doi:10.36171/jamd20.23.4.6
Mason, M. A., Russ, A. C., Tierney, R., & Mansell, J. L. (2021) · International Journal of Athletic Therapy & Training · doi:10.1123/ijatt.2020-0109
Hypoglycaemia in type 2 diabetes treated with pre‐mixed insulin
IDRIS, I. R., Annamalai, N., Aung, T., Binnian, I., Gibb, F. W., Malik, M. I., & Ramtoola, S. (2021) · Diabetic Medicine · doi:10.1111/dme.14684
Alvarenga, C. S. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.22.2021.tde-14122021-173701
Metabolic and cardiovascular risk factors associated with type 1 Diabetes Mellitus in pediatric age
Araújo, M., & Correia, C. C. (2022) · Revista Portuguesa de Endocrinologia Diabetes e Metabolismo · doi:10.26497/ar210013
(2020) · Journal of Bioscience & Biomedical Engineering · doi:10.47485/2693-2504.1008
Gomille, L. K., Grammes, J., Lehnart, J., Binz, C., Koehn, S., Kubiak, T., & Benecke, A. (2022) · Diabetologie und Stoffwechsel · doi:10.1055/a-1928-9691
“[43] Beck RW, Bergenstal RM, Cheng P et al.”
BackgroundVasishth, A., Nagaveni, S., Anand, G., & Chitturi, K. L. (2022) · Springer eBooks · doi:10.1007/978-981-19-4001-9_12
Application of the New “Points in Range” Metrics in the Assessment of In-Hospital Glycemic Control
Rosinha, P. M. O., Teixeira, S., Amaral, C., & Cardoso, M. H. (2023) · Cureus · doi:10.7759/cureus.34278 · Cited by 1
“PIR PAR (70-180 mg/dL) (>180 mg/dL) Correlation coefficient (ρ) p value Correlation coefficient (ρ) p value Number of CBG tests -0.094 0.549 0.684 <0.001 Days of hospitalization 0.222 0.152 -0.139 0.508 TABLE 3: Correlation analysis CBG, capillary blood glucose; HbA1c, glycated hemoglobin; PAR, points above range; PIR…”
BackgroundInfluentialAnderzén, J. (2023) · Linköping University medical dissertations · doi:10.3384/9789180750325
Chawla, M. S., CHAWLA, P. M., Saboo, B., Kesavadev, J., Gupta, A., & Parikh, R. M. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_12_22 · Cited by 1
Stojanović, M., Pešić, M., Ilić, S., Deljanin-Ilić, M., & Ćirić, V. M. (2022) · AFMN Biomedicine · doi:10.5937/afmnai40-37498
“Individual goals were set for different patient groups, but TIR above 70% is the most important goal, and this value correlates with HbA1c 7% in type 1 diabetes patients (7).”
BackgroundContinuous Glucose Monitoring-Assisted Insulin Dose Titration in the Indian Outpatient Setting
Ganti, S. R., & Gurazada, K. C. (2022) · International Journal of Diabetes and Technology · doi:10.4103/ijdt.ijdt_16_22
Metadata
- Authors
- Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D.
- Affiliations
- Jaeb Center for Health Research (US)
- Park Nicollet Clinic (US)
- Biomedical Informatics Consultants, LLC, Potomac, MD, USA
- Corresponding author
- Beck, Roy W.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2019-01-13
- Volume
- 13
- Issue
- 4
- Pages
- 614-626
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6610606
- OpenAlex
- W2910274134
- Semantic Scholar
- 5dcb6eaae421097f5303338e5e6ad5f5808ef649
- Cited by
- 479
- References
- 29
- Citations by year
- 2026: 53 · 2025: 60 · 2024: 62 · 2023: 66 · 2022: 72 · 2021: 80 · 2020: 71 · 2019: 15
- FWCI
- 48.30
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Jaeb Center for Research Foundation
- Sanofi
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- time in range, HbA1c, continuous glucose monitoring, type 1 diabetes, glycemic control, mean blood glucose
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hyperglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.