The Relationships Between Time in Range, Hyperglycemia Metrics, and HbA1c
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: As the use of continuous glucose monitoring (CGM) increases, there is a need to better understand key metrics of time in range 70-180 mg/dL (TIR 70-180 ) and hyperglycemia and how they relate to hemoglobin A1c (A1C). Methods: Analyses were conducted utilizing datasets from four randomized trials encompassing 545 adults with type 1 diabetes (T1D) who had central-laboratory measurements of A1C. CGM metrics were calculated and compared with each other and A1C cross-sectionally and longitudinally. Results: Correlations among CGM metrics (TIR 70-180 , time >180 mg/dL, time >250 mg/dL, mean glucose, area under the curve above 180 mg/dL, high blood glucose index, and time in range 70-140 mg/dL) were typically 0.90 or greater. Correlations of each metric with A1C were lower (absolute values 0.66-0.71 at baseline and 0.73-0.78 at month 6). For a given TIR 70-180 percentage, there was a wide range of possible A1C levels that could be associated with that TIR 70-180 level. On average, a TIR 70-180 of 70% and 50% corresponded with an A1C of approximately 7% and 8%, respectively. There also was considerable spread of change in A1C for a given change in TIR 70-180 , and vice versa. An increase in TIR 70-180 of 10% (2.4 hours per day) corresponded to a decrease in A1C of 0.6%, on average. Conclusions: In T1D, CGM measures reflecting hyperglycemia (including TIR and mean glucose) are highly correlated with each other but only moderately correlated with A1C. For a given TIR or change in TIR there is a wide range of possible corresponding A1C values.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Use of structured BGM data to adjust medications is associated with greater A1C decreases than unstructured BGM.151,152”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [152]
In the citing paper
“Relationships between time in target range and A1C (25; 26) and number of severe and non-severe hypoglycemic events (27-31) have also been observed.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“Importantly, as demonstrated by Beck et al. (25), Vigersky et al. (26) and Feig et al. (47), even small, incremental improvements yield significant glycemic benefits.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
11 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationTranslating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationValidation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Self-citationGlucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationHeinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Self-citationThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Research works printed but not linked: 1
- Peters AL, Paper presented at: European Association for the Study of Diabetes Meeting
Cited by
Items 101–200 of 475
Babaya, N., Noso, S., Hiromine, Y., Taketomo, Y., Niwano, F., Yoshida, S., Yasutake, S., Kawabata, Y., & Ikegami, H. (2021) · Scientific Reports · doi:10.1038/s41598-021-83599-x · Cited by 38
Marks, B. E., Williams, K. M., Sherwood, J. S., & Putman, M. S. (2021) · Journal of Clinical & Translational Endocrinology · doi:10.1016/j.jcte.2021.100282 · Cited by 39
“Studies have shown that 70% TIR (16.8 h per day) is correlated with an A1c of 7% and International Consensus Guidelines therefore recommend a target of 70% TIR, 5% TBR (1.2 h per day), and 30% TAR (7.2 h) for most individuals with T1D and T2D [26,27].”
BackgroundInfluentialThrasher, J. R., Arrieta, A., Niu, F., Cameron, K. R., Cordero, T. L., Shin, J., Rhinehart, A. S., & Vigersky, R. A. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0453 · Cited by 33
“Given the established relationship between %TIR and A1C 52,53 and that a higher %TIR associates with reduced risk of T1D complications, 1,4 there is valid emerging evidence for AID therapy as a standard of T1D care, due to its performance in improving CGM metrics and A1C.”
Jia, Y., Long, D., Yang, Y., Wang, Q., Wu, Q., & Zhang, Q. (2024) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111757 · Cited by 36
Cutruzzolà, A., Irace, C., Parise, M., Fiorentino, R., Tripodi, P. F. P., Ungaro, S., Babinsky, V. N., & Gnasso, A. (2020) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2020.06.009 · Cited by 32
Xie, P., Deng, B., Zhang, X., Li, Y., Du, C., Rui, S., Deng, W., Boey, J., Armstrong, D. G., Ma, Y., et al. (2021) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.3498 · Cited by 33
“Furthermore, a strong linear correlation between TAR and TIR showed that they are both hyperglycaemic metrics, in line with evidence that glycaemic metrics reflecting hyperglycaemia were highly correlated with each other.(35) CV as a metric of blood glucose excursion has been linked to microvascular complications and…”
BackgroundResultWang, Y., Lu, J., Ni, J., Wang, M., Shen, Y., Lu, W., Zhu, W., Bao, Y., Rodbard, D., Vigersky, R. A., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15068 · Cited by 33
“ever, a criticism of TIR is that it is highly correlated with hyperglycaemia and is not adequately sensitive to hypoglycaemia.(15,16) The clinical management of diabetes has been recognized as a”
BackgroundSelf-citationIrace, C., Cutruzzolà, A., Nuzzi, A., Assaloni, R., Brunato, B., Pitocco, D., Tartaglione, L., Molfetta, S. D., Cignarelli, A., Laviola, L., et al. (2020) · Diabetes Obesity and Metabolism · doi:10.1111/dom.13993 · Cited by 29
“These findings were consistent with previous reports, which have linked a 0.5% decrease in HbA1c to a 10% increase in TIR.13 As expected, the two CGM naïve subgroups had relatively higher baseline HbA1c values and poorer CGM metrics than those with previous CGM use; consequently, their values improved to a greater deg…”
ResultInfluentialPediatric Medicaid Patients With Type 1 Diabetes Benefit From Continuous Glucose Monitor Technology
Ravi, S., Coakley, A., Vigers, T., Pyle, L. L., Forlenza, G. P., & Alonso, T. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820906214 · Cited by 29
Association of time in range with hemoglobin A1c, glycated albumin and 1,5‐anhydro‐ d ‐glucitol
Ohigashi, M., Osugi, K., Kusunoki, Y., Washio, K., Matsutani, S., Tsunoda, T., Matsuo, T., Konishi, K., Katsuno, T., Namba, M., et al. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13437 · Cited by 33
“Beck et al.27 reported that a TIR70–180 of 70% corresponded to an HbA1c level of approximately 7%.”
BackgroundInfluentialGoldenberg, R., Aroda, V. R., Billings, L. K., Christiansen, A. S. L., Donatsky, A. M., Rizi, E. P., Podgorski, G., Rašlová, K., Klonoff, D. C., & Bergenstal, R. M. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14504 · Cited by 34
“4% improvement in HbA1c.(6,22) In the present study, the ETD in HbA1c was 0.”
BackgroundInfluentialSelf-citationMartin, C., Criego, A. B., Carlson, A. L., & Bergenstal, R. M. (2019) · Current Diabetes Reports · doi:10.1007/s11892-019-1177-7 · Cited by 34
Self-citationSzmuilowicz, E. D., & Aleppo, G. (2022) · Postgraduate Medicine · doi:10.1080/00325481.2022.2110507 · Cited by 27
Aronson, R., Brown, R. E., Abitbol, A., Goldenberg, R., Yared, Z., Ajala, B., & Yale, J.-F. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0204 · Cited by 27
“Among CGM users, mean TIR was 53.4% and the recommended target of > 70% 25,26 was only achieved by 15.7% of CGM users.”
InfluentialEstimating Glycemia From HbA1c and CGM: Analysis of Accuracy and Sources of Discrepancy
Tozzo, V., Genco, M. T., Omololu, S. O., Mow, C., Patel, H. R., Patel, C. H., Ho, S. N., Lam, E., Abdulsater, B., Patel, N., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1177 · Cited by 31
Cai, J., Liu, J., Lu, J., Ni, J., Wang, C., Chen, L., Lu, W., Zhu, W., Xia, T., & Zhou, J. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16212 · Cited by 30
Samson, S. L., Vellanki, P., Blonde, L., Hirsch, I. B., Hoang, T. D., Isaacs, S. D., Izuora, K. E., Wang, C. C. L., Ooi, C. P., Padilla, B. I., et al. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.01.006 · Cited by 36
Mesa, A., Giménez, M., Pueyo, I., Perea, V., Viñals, C., Blanco, J., Vinagre, I., Serés‐Noriega, T., Boswell, L., Esmatjes, E., et al. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109938 · Cited by 31
Future horizons in diabetes: integrating AI and personalized care
Zhang, K., Qi, Y. P., Wang, W., Tian, X., Wang, J., Xu, L., & Zhai, X. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1583227 · Cited by 36
Using Person-Reported Outcomes (PROs) to Motivate Young People with Diabetes
de Wit, M., Versloot, J., Zenlea, I. S., & Goethals, E. R. (2020) · Current Diabetes Reports · doi:10.1007/s11892-020-01305-z · Cited by 29
“Reflecting the unique person perspective, PROs provide an avenue for the health care provider to directly assess and discuss these relevant psychosocial developments in a dialogue with the person and their family, instead of mainly focusing on the medical outcomes such as HbA1c and time in range [23].”
BackgroundAktürk, H. K., Battelino, T., Castañeda, J., Arrieta, A., van den Heuvel, T. R. A., & Cohen, O. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0432 · Cited by 27
“44 Similarly, * 20% point difference was also noted between TIR and TITR in the four trials described by Beck et al. 23 To get insights in the achievable TITR with the MiniMed (cid:2) 780G system, we assessed TITR from a large cohort of real-world users of this system ( N > 10,000 users) and correlated this with the g…”
InfluentialMalone, S. K., Peleckis, A. J., Grunin, L., Yu, G., Jang, S., Weimer, J. E., Lee, I., Rickels, M. R., & Goel, N. (2021) · Journal of Diabetes Research · doi:10.1155/2021/6611064 · Cited by 26
Shah, V. N., Snell‐Bergeon, J. K., Demmitt, J. K., Joshee, P., Garcetti, R., Pyle, L. L., & Polsky, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0093 · Cited by 26
“23,24 Our FIG.”
InfluentialUtilizing continuous glucose monitoring in primary care practice: What the numbers mean
Edelman, S. V., Cavaiola, T. S., BOEDER, S. C., & Pettus, J. (2020) · Primary care diabetes · doi:10.1016/j.pcd.2020.10.013 · Cited by 27
Critical Reappraisal of the Time-in-Range: Alternative or Useful Addition to Glycated Hemoglobin?
Heinemann, L., Freckmann, G., Müller‐Wieland, D., & Kellerer, M. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883885 · Cited by 28
“Hence, the measurement error is approximately 4% as compared to 5% for HbA1c.”
BackgroundInfluentialAchieving the HbA1c Target Requires Longer Time in Range in Pregnant Women With Type 1 Diabetes
Ling, P., Yang, D., Gu, N., Xiao, X., Lü, J., Liu, F., Zhou, Z., Huang, Q., Zhao, J., Zhang, M., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab502 · Cited by 27
“However, considering the difference in physiological changes in HbA1c during pregnancy, all the studies excluded pregnant populations (2, 8, 9, 23).”
BackgroundTime-in-range and frequency of continuous glucose monitoring: Recommendations for South Asia
Kesavadev, J., Misra, A., Saboo, B., Agarwal, S., Sosale, A., Joshi, S., Hussain, A., Somasundaram, N. P., Basit, A., Choudhary, P., et al. (2021) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2021.102345 · Cited by 24
Pérez-López, P., Fernández-Velasco, P., Bahillo-Curieses, P., de Luis, D. A., & Díaz-Soto, G. (2023) · Endocrine · doi:10.1007/s12020-023-03511-7 · Cited by 30
“Due to both HbA1c and TIR being parameters of centrality, several studies have shown a strong negative relationship between the two variables [7, 8].”
BackgroundEhrmann, D., Priesterroth, L., SCHMITT, A. J., Kulzer, B., & Hermanns, N. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0096 · Cited by 24
Time in range—A new gold standard in type 2 diabetes research?
Goshrani, A., Lin, R., O'Neal, D. N., & Ekinci, E. I. (2025) · Diabetes Obesity and Metabolism · doi:10.1111/dom.16279 · Cited by 26
“Beck et al. performed a cross-sectional longitudinal analysis of datasets from four clinical trials that assessed the effectiveness of CGM in 545 participants with type 1 diabetes.”
Cho, S. H., Kim, S., Lee, Y., Jin, S., Hur, K. Y., Kim, G., & Kim, J. H. (2023) · Frontiers in Endocrinology · doi:10.3389/fendo.2023.1165471 · Cited by 29
Eviz, E., Kıllı, N. E., Karakus, K. E., Can, E., Gökçe, T., Mutlu, G. Y., & Hatun, Ş. (2024) · Diabetic Medicine · doi:10.1111/dme.15333 · Cited by 24
“5,24 FIGURE 3 Demographic features and glycaemic parameters by autocorrection percentages.”
Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes
Friedman, J. G., Coyne, K., Aleppo, G., & Szmuilowicz, E. D. (2023) · Endocrine Connections · doi:10.1530/ec-23-0085 · Cited by 22
Smith, K., Taylor, G., Brunsgaard, L. H., Walker, M., Davies, K. A. B., Stevenson, E., & West, D. J. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2022-002820 · Cited by 26
“15 16 Accordingly, the utility of mealtime WP supplementation on day- to-day glucose control remains to be established.”
The Glycemic Ratio Is Strongly and Independently Associated With Mortality in the Critically Ill
Roberts, G., Krinsley, J. S., Preiser, J., Quinn, S. J., Rule, P. R., Brownlee, M., Schwartz, M. W., Umpierrez, G. E., & Hirsch, I. B. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221124114 · Cited by 25
“…gradually decreased, culminating with a mean HbA1c of 5.2% in those with GR ≥ 1.30, but with an associated mBG of 153 mg/dL. Preadmission glycemia was also calculated using the equation from Beck et al 34 and relationships between GR and mortality remained unaffected (Supplementary Figure 2).”
MethodInfluentialSuzuki, J., Urakami, T., Yoshida, K., Kuwabara, R., Mine, Y., Aoki, M., & Morioka, I. (2020) · Pediatrics International · doi:10.1111/ped.14412 · Cited by 26
Piona, C. A., Marigliano, M., Mozzillo, E., Rosanio, F. M., Zanfardino, A., Iafusco, D., Maltoni, G., Zucchini, S., Piccinno, E., Delvecchio, M., et al. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108933 · Cited by 25
Quality of Glycemic Control: Assessment Using Relationships Between Metrics for Safety and Efficacy
Rodbard, D. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0115 · Cited by 22
“3,22,36,37,48,52 Accordingly, either %TIR or %TAR can be used as the independent variable to be displayed on the horizontal axis in lieu of HbA1c or Mean Glucose .”
Self-citationBeck, R. W., & Bergenstal, R. M. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0090 · Cited by 24
Self-citationMohan, V., Joshi, S., Mithal, A., Kesavadev, J., Unnikrishnan, A., Saboo, B., Kumar, P. R. G., Chawla, M. S., Bhograj, A., & KOVIL, R. R. (2023) · Diabetes Therapy · doi:10.1007/s13300-022-01355-4 · Cited by 31
Urakami, T., Yoshida, K., Kuwabara, R., Mine, Y., Aoki, M., Suzuki, J., & Morioka, I. (2020) · Endocrine Journal · doi:10.1507/endocrj.ej20-0193 · Cited by 24
“Nonetheless, CGM or isCGM may show some out-of-range values, possibly due to sensor errors and a compression artifact during sleep, particularly with regard to low glucose lev‐ els; this can influence the eA1c value [17].”
BackgroundMethodInfluentialTime in Range as a Research Outcome Measure
Timmons, J. G., Boyle, J. G., & Petrie, J. R. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0097 · Cited by 23
Performance of the Glucose Management Indicator (GMI) in Type 2 Diabetes
Fang, M., Wang, D., Rooney, M. R., Echouffo-Tcheugui, J. B., Coresh, J., Aurora, R. N., Punjabi, N. M., & Selvin, E. (2023) · Clinical Chemistry · doi:10.1093/clinchem/hvac210 · Cited by 26
The Ambulatory Glucose Profile: Opportunities for Enhancement
Rodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0524 · Cited by 24
“56 25,57,58 Interestingly, %TAR slightly higher correlation and We expect that at least a few of the enhancements to the AGP discussed in this review will prove to be useful to patients and health care professionals.”
Self-citationZivojinovic, A. S. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.105605 · Cited by 22
Eliasson, B., Kjölhede, E. A., Salö, S., Nielsen, N. F., & Eeg‐Olofsson, K. (2024) · Diabetes Therapy · doi:10.1007/s13300-024-01572-z · Cited by 21
“Beck et al. [4] examined data from randomized clinical trials and found a relatively strong cor‑ relation ( r = 0.67–0.73) between TIR and HbA1c in type 1 diabetes, while Vigersky and McMahon [5], using similar methods, suggested a higher correlation ( r = − 0.84) between these variables based on…”
MethodInfluentialDíaz-Soto, G., Bahillo-Curieses, P., Jimenez, R., de la Marca, M. D. L. O. N., Gomez, E., Torres, B., Gómez, J. J. L., & de Luis, D. A. (2021) · Endocrinología Diabetes y Nutrición (English ed ) · doi:10.1016/j.endien.2021.11.006 · Cited by 24
Grady, M., Cameron, H., Bhatiker, A., Holt, E., & Schnell, O. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0134 · Cited by 20
“4%.(14,15) Given that we do not have the same quantity of readings per patient for BGM users compared with CGM users, we determined it was more appropriate to explore trends in glycemic control, and there would be more weight to our findings, by utilizing a far larger dataset of PWDs using BGM than is common in most R…”
MethodEviz, E., Mutlu, G. Y., Karakus, K. E., Can, E., Gökçe, T., Muradoğlu, S., & Hatun, Ş. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0112 · Cited by 19
“24 The strong correlation between TIR and GRI suggests that GRI may significantly correlate with HbA1c.”
Isaksson, S. S., Imberg, H., Hirsch, I. B., Schwarcz, E., Hellman, J., Wijkman, M. O., Bolinder, J., Nyström, T., Holmer, H., Hallström, S., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06151-2 · Cited by 21
“Although earlier studies found a discordance between MG, TIR and HbA 1c [13–17], the associations are poorly understood.”
InfluentialThe dawn phenomenon across the glycemic continuum: Implications for defining dysglycemia
Li, C., Ma, X., Yin, J., Mo, Y., Zhang, L., Lu, J., Lu, W., Bao, Y., Vigersky, R. A., Zhou, J., et al. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108308 · Cited by 19
O’Donnell, H. K., Johnson, S. B., Sileo, D., Majidi, S., Gonder-Frederick, L. A., & Driscoll, K. A. (2021) · Journal of Pediatric Psychology · doi:10.1093/jpepsy/jsab093 · Cited by 21
Divani, M., Georgianos, P. I., Didangelos, T., Liakopoulos, V., Makedou, K., Iliadis, F. S., Savopoulos, C. G., & Grekas, D. M. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10184116 · Cited by 20
“In a combined analysis of four randomized trials incorporating CGM data from 545 adults with type 1 diabetes, it was shown that an HbA1c of 7% and 8% corresponded to a TIR70–180 of 70% and 50%, respectively [9].”
BackgroundMethodDovč, K., Name, M. A. V., Bizjan, B. J., Rusak, E., Piona, C. A., Mutlu, G. Y., Mentink, R., Frontino, G., Macedoni, M., Ferreira, S., et al. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14607 · Cited by 21
“shown in older individuals with diabetes, in addition to a strong correlation between TBR and CV.(19) As CGM is becoming standard of care for young children in many countries,(7,20) conducting a clinical trial”
BackgroundXu, Y., Dunn, T. C., Bergenstal, R. M., Cheng, A., Dabiri, Y., & Ajjan, R. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0564 · Cited by 21
“The AG, CV, TIR, and TITR changes over diabetes duration were plotted in Figure 5.”
InfluentialSelf-citationGlucose Patterns in Very Old Adults: A Pilot Study in a Community-Based Population
Selvin, E., Wang, D., Tang, O., Minotti, M., Echouffo-Tcheugui, J. B., & Coresh, J. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0156 · Cited by 21
den Braber, N., Vollenbroek-Hutten, M. M. R., Westerik, K. M., Bakker, S. J. L., Navis, G. J., van Beijnum, B.-J. F., & Laverman, G. D. (2021) · Diabetes Care · doi:10.2337/dc20-2241 · Cited by 21
“Bolus only regimen, n 79 8 (10) 2 (10) 3 (14) 3 (8) 0.”
BackgroundSuzuki, D., Yamada, H., Yoshida, M., Funazaki, S., Amamoto, M., Morimoto, J., & Hara, K. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13240 · Cited by 20
Using continuous glucose monitoring data in daily clinical practice
Martens, T. W., Simonson, G. D., & Bergenstal, R. M. (2024) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.91a.23090 · Cited by 24
“16,17 A hemoglobin A1c target of 7.0% or less is supported by multiple landmark diabetes studies, including the UK Prospective Diabetes Study and the Diabetes Control and Complications Trial data.”
InfluentialSelf-citationSalvi, E., Bosoni, P., Tibollo, V., Kruijver, L., Calcaterra, V., Sacchi, L., Bellazzi, R., & Larizza, C. (2019) · Sensors · doi:10.3390/s20010128 · Cited by 20
Takao, T., Suka, M., Yanagisawa, H., & Kasuga, M. (2020) · Journal of Diabetes Investigation · doi:10.1111/jdi.13403 · Cited by 20
O'Neal, D. N., Cohen, O., Vogrin, S., Vigersky, R. A., Jenkins, A. J., McAuley, S. A., Lee, M. H., Paldus, B., Sims, C. M., MacIsaac, R. J., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0350 · Cited by 16
“11,12 However, our observations also indicate that the relationship of TIR with TBR is tenuous.”
A novel few shot learning derived architecture for long-term HbA1c prediction
Qaraqe, M., Elzein, A., Belhaouari, S. B., Ilam, M. S., & Petrovski, G. (2024) · Scientific Reports · doi:10.1038/s41598-023-50348-1 · Cited by 18
Kim, J. Y., Jin, S.-M., Kang, E. S., Kwak, S. H., Yang, Y., Yoo, J. H., Bae, J. H., Moon, J. S., Jung, C. H., Bae, J. C., et al. (2024) · Diabetologia · doi:10.1007/s00125-024-06155-y · Cited by 22
“Given that a 5% increase in TIR has been deemed clinically significant [5, 25], the additional improvement in TIR achieved with the tubeless, on-body AID system compared with the SAP is promising.”
Glycemic Status Assessment by the Latest Glucose Monitoring Technologies
Malandrucco, I., Russo, B., Picconi, F., Menduni, M., & Frontoni, S. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21218243 · Cited by 17
“The relationship of HbA1c to TIR in patients with diabetes has been widely demonstrated [16].”
BackgroundFeng, Z., Guo, Q., Wang, W., Yuan, Y., Jin, X., Zhou, H., Liu, J., Lei, H., Yang, X., Liu, J., et al. (2021) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-021-00739-z · Cited by 17
Préau, Y., Galie, S., Schaepelynck, P., Armand, M., & Raccah, D. (2021) · Sensors · doi:10.3390/s21186131 · Cited by 20
“the duration of CGM data captured, the IG concentration average (stronger association if IG average is between 120 and 200 mg/dL) and factors affecting the accuracy of HbA1c assay [7,27].”
BackgroundHybrid Control Policy for Artificial Pancreas via Ensemble Deep Reinforcement Learning
Lv, W., Wu, T., Xiong, L., Wu, L., Zhou, J., Tang, Y. S., & Qian, F. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3451712 · Cited by 17
Paing, A. C., McMillan, K. A., Kirk, A. F., Collier, A., Hewitt, A., & CHASTIN, S. F. M. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04261-z · Cited by 19
Buschur, E., Campbell, K. R., Pyle, L. L., Garcetti, R., Joshee, P., Demmitt, J. K., Snell‐Bergeon, J. K., & Polsky, S. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0138 · Cited by 22
“28 The strengths of mean SG, TIR, time above range, and time below range are that these are clinically correlated with risk for microvascular and macrovascular complications of diabetes 4–6 and risk for suboptimal neonatal outcomes in pregnancy.”
Kawaguchi, Y., Miyamoto, S., Hajika, Y., Ashida, N., Hirota, T., Masumoto, K., Sawa, J., Hamazaki, K., & Kumeda, Y. (2022) · Advances in Therapy · doi:10.1007/s12325-022-02138-w · Cited by 15
“0% when the TIR in isCGM was 70% [34]; therefore, the target value for diabetes treatment using isCGM should be at least 70% in TIR [21].”
MethodPemberton, J. S., Barrett, T. G., Dias, R. P., Kershaw, M., Krone, R. E., & Uday, S. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13381 · Cited by 15
Raghinaru, D., Calhoun, P., Bergenstal, R. M., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0274 · Cited by 15
Self-citationIssar, T., Tummanapalli, S. S., Kwai, N. C. G., Chiang, J. C. B., Arnold, R., Poynten, A. M., Markoulli, M. P., & Krishnan, A. V. (2020) · Diabetic Medicine · doi:10.1111/dme.14306 · Cited by 16
Automated Insulin Delivery in Real Life (AID-IRL): Real-World User Perspectives on Commercial AID
Lewis, D. M. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820957360 · Cited by 15
Radovnická, L., Hásková, A., Do, Q. D., Horová, E., Navrátilová, V., Mikeš, O., Cihlář, D., Parkin, C. G., Grunberger, G., Prázný, M., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0152 · Cited by 14
“Our analysis showed that the correlations were similar to those reported by Beck et al, 12 and Vigersky and McMahon.”
Yoshii, H., Mita, T., Katakami, N., Okada, Y., Osonoi, T., Aso, K., Kurozumi, A., Wakasugi, S., Sato, F., Ishii, R., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac459 · Cited by 17
“0% in patients with type 1 diabetes (13) or 6.”
BackgroundSchnell, O., Valensi, P. E., Standl, E., & Ceriello, A. (2020) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.129 · Cited by 15
Gad, H., Elgassim, E., Mohammed, I., Alhaddad, A. Y., Aly, H., Cabibihan, J., Al-Ali, A. K., Sadasivuni, K. K., Haji, A., Lamine, N., et al. (2022) · Endocrine Connections · doi:10.1530/ec-22-0352 · Cited by 18
“Continuous glucose monitoring (CGM) provides time in range (TIR) which is directly related to HbA1c, but also additional measures in relation to high and low blood glucose levels [6, 7].”
BackgroundInitiation of Continuous Glucose Monitoring and Mortality in Type 2 Diabetes
Reaven, P. D., Macwan, S. A., Newell, M., Arani, G., Norman, G. J., Miller, D. R., & Zhou, J. J. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0227 · Cited by 14
“Based on prior studies, we recognize that CGM use would also improve other metrics of glycemic control, such as time in range, time above and below range, and glycemic variability, 1,29 which also have been linked to fewer diabetes complications.”
Endocrine Complications of Cystic Fibrosis
Kelly, A. T., Marks, B. E., & Stalvey, M. S. (2022) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2022.06.013 · Cited by 13
Making sense of glucose sensors in end-stage kidney disease: A review
Williams, M. E., Steenkamp, D., & Wolpert, H. A. (2022) · Frontiers in Clinical Diabetes and Healthcare · doi:10.3389/fcdhc.2022.1025328 · Cited by 14
Martens, T. W., Bergenstal, R. M., Pearson, T. L., Carlson, A. L., Scheiner, G., Carlos, C., Liao, B., Syring, K. E., & Pollom, R. D. (2020) · Postgraduate Medicine · doi:10.1080/00325481.2020.1851946 · Cited by 14
“that every 5% increase in TIR is clinically meaningful [44].”
BackgroundSelf-citationWang, Y., Lu, J., Shen, Y., Ni, J., Zhang, L., Lu, W., Zhu, W., Bao, Y., & Zhou, J. (2022) · Endocrine · doi:10.1007/s12020-022-03038-3 · Cited by 13
“Given the correlation of TIR with both hyperglycemia metrics and GV [29, 30], it is no surprise that TIR was closely linked to LEAD and other”
BackgroundStandardized Hybrid Closed-Loop System Reporting
Shah, V. N., & Garg, S. K. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0622 · Cited by 14
Díaz-Soto, G., Bahillo-Curieses, P., Jimenez, R., de la Marca, M. D. L. O. N., Hoyos, E. G., Torres, B., Gómez, J. J. L., & de Luis, D. A. (2021) · Endocrinología Diabetes y Nutrición · doi:10.1016/j.endinu.2020.09.008 · Cited by 14
Pemberton, J. S., Andrews, R. C., Barnard-Kelly, K. D., Battelino, T., Danne, T., Heinemann, L., Kar, P., Lumb, A. N., Maahs, D. M., Mader, J. K., et al. (2026) · Diabetes Obesity and Metabolism · doi:10.1111/dom.70460 · Cited by 18
Research progress in the application of time in range: more than a percentage
Wan, J., Lu, J., Li, C., Ma, X., & Zhou, J. (2023) · Chinese Medical Journal · doi:10.1097/cm9.0000000000002582 · Cited by 12
“Therefore, the International Consensus on Time in Range recommended that a minimum of 14 days of CGM monitoring is essential for accurate and meaningful interpretation of CGM [5] data.”
InfluentialLee, S., Lee, S., Kim, K. M., & Shin, J. H. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1145470 · Cited by 14
Monnier, L., Colette, C., & Owens, D. R. (2020) · Diabetes & Metabolism · doi:10.1016/j.diabet.2020.06.004 · Cited by 13
de Oliveira, F. M., Calliari, L. E., Feder, C. K. R., de Almeida, M. F. O., Pereira, M. V., Alves, M. T. T. D. A. F., Garcia, S. A. D., Reis, L. D. D., & Salles, J. E. N. (2021) · Archives of Endocrinology and Metabolism · doi:10.20945/2359-3997000000334 · Cited by 17
“Defining adherence can be complex in patients with T1DM or LADA (16), since it requires the assessment of tasks, behaviors (16-19), and treatment regimens that are not universal or static (16,19) in the absence of a reliable biological marker (e.”
BackgroundBae, J. C., Kwak, S. H., Kim, H. J., Kim, S.-Y., Hwang, Y., Suh, S., Hyun, B. J., Cha, J. E., Won, J. C., & Kim, J. H. (2021) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2021.0016 · Cited by 14
“A study by Beck et al. [26], involving four RCTs that included 545 patients with T1DM, showed a relationship between a change in TIR70–180 and a change in HbA1c levels.”
BackgroundCorathers, S. D., & DeSalvo, D. J. (2020) · Diabetes Spectrum · doi:10.2337/ds19-0017 · Cited by 15
Blevins, T., Lane, W. S., Rodbard, D., Sindelar, D. K., Fan, L., Ellinor, K., Ilag, L. L., Ly, T. T., & Johnson, J. L. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0030 · Cited by 12
“25 In the MDI group, percent TIR 70–180 mg/dL increased by a nominal 3% over 26 weeks, with a nominal 8% decrease in percent time > 180 mg/dL. Percent time in Level 1 hypoglycemia did increase significantly, without a significant change in Level 2 hypoglycemia.”
Self-citationThe Effects of Dietary Nutrition Intake on Glycemic Variability in Type 1 Diabetes Mellitus Adults
Zhou, L., Deng, M., Zhai, X., Yu, R., Liu, J. Y., Yu, M., Li, Y., & Xiao, X. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01028-8 · Cited by 12
“According to the Expert Consensus on the Management of Blood Glucose Fluctuations in Diabetic Patients [15], the following are used as normal thresholds: SD\1.4 mmol/L, MAGE\ 3.9 mmol/L, MODD\0.83 mmol/L. Time above range (TAR) (”
MethodInfluentialDimova, R. B., Chakarova, N. Y., Grozeva, G. G., & Tankova, T. I. (2020) · Diabetes and Vascular Disease Research · doi:10.1177/1479164120958619 · Cited by 13
Saboo, B., Garg, S. K., Bergenstal, R. M., Battelino, T., Ceriello, A., Choudhary, P., de Bock, M. I., Elbarbary, N. S., Forlenza, G. P., Gómez, A. M., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0028 · Cited by 12
Self-citationSignificance of the CGM metric of time in range in children and adolescents with type 1 diabetes
Urakami, T. (2022) · Endocrine Journal · doi:10.1507/endocrj.ej22-0257 · Cited by 11
Takuma, K., Fuchigami, A., Shigiyama, F., Kumashiro, N., & Hirose, T. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15089 · Cited by 13
Zimmer, R. T., Birnbaumer, P., Sternad, C., Zunner, B. E. M., Schierbauer, J., Fritsch, M., Fröhlich-Reiterer, E. E., Hofmann, P., Sourij, H., Aberer, F., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15352 · Cited by 14
“49,50 It is crucial to view our study in context, as in the field of TIR research among children and adolescents in specific sports, limited data are available.”
Background
Metadata
- Authors
- Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D.
- Affiliations
- Jaeb Center for Health Research (US)
- Park Nicollet Clinic (US)
- Biomedical Informatics Consultants, LLC, Potomac, MD, USA
- Corresponding author
- Beck, Roy W.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2019-01-13
- Volume
- 13
- Issue
- 4
- Pages
- 614-626
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6610606
- OpenAlex
- W2910274134
- Semantic Scholar
- 5dcb6eaae421097f5303338e5e6ad5f5808ef649
- Cited by
- 479
- References
- 29
- Citations by year
- 2026: 53 · 2025: 60 · 2024: 62 · 2023: 66 · 2022: 72 · 2021: 80 · 2020: 71 · 2019: 15
- FWCI
- 48.30
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Jaeb Center for Research Foundation
- Sanofi
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- time in range, HbA1c, continuous glucose monitoring, type 1 diabetes, glycemic control, mean blood glucose
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hyperglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.