The Relationships Between Time in Range, Hyperglycemia Metrics, and HbA1c
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Background: As the use of continuous glucose monitoring (CGM) increases, there is a need to better understand key metrics of time in range 70-180 mg/dL (TIR 70-180 ) and hyperglycemia and how they relate to hemoglobin A1c (A1C). Methods: Analyses were conducted utilizing datasets from four randomized trials encompassing 545 adults with type 1 diabetes (T1D) who had central-laboratory measurements of A1C. CGM metrics were calculated and compared with each other and A1C cross-sectionally and longitudinally. Results: Correlations among CGM metrics (TIR 70-180 , time >180 mg/dL, time >250 mg/dL, mean glucose, area under the curve above 180 mg/dL, high blood glucose index, and time in range 70-140 mg/dL) were typically 0.90 or greater. Correlations of each metric with A1C were lower (absolute values 0.66-0.71 at baseline and 0.73-0.78 at month 6). For a given TIR 70-180 percentage, there was a wide range of possible A1C levels that could be associated with that TIR 70-180 level. On average, a TIR 70-180 of 70% and 50% corresponded with an A1C of approximately 7% and 8%, respectively. There also was considerable spread of change in A1C for a given change in TIR 70-180 , and vice versa. An increase in TIR 70-180 of 10% (2.4 hours per day) corresponded to a decrease in A1C of 0.6%, on average. Conclusions: In T1D, CGM measures reflecting hyperglycemia (including TIR and mean glucose) are highly correlated with each other but only moderately correlated with A1C. For a given TIR or change in TIR there is a wide range of possible corresponding A1C values.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Use of structured BGM data to adjust medications is associated with greater A1C decreases than unstructured BGM.151,152”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [152]
In the citing paper
“Relationships between time in target range and A1C (25; 26) and number of severe and non-severe hypoglycemic events (27-31) have also been observed.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“Importantly, as demonstrated by Beck et al. (25), Vigersky et al. (26) and Feig et al. (47), even small, incremental improvements yield significant glycemic benefits.”
From Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range (2019) · cites this paper as [26]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
In the citing paper
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically significant benefits for those populations20,21.”
From Impact of digital health interventions on glycemic control and weight management. (2025) · cites this paper as [20]
11 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationTranslating the A1C assay into estimated average glucose values
Nathan, D. M., Kuenen, J., Borg, R., Zheng, H., Schoenfeld, D., Heine, R. J., & for the A1c-Derived Average Glucose (ADAG) Study Group (2008) · Diabetes Care · doi:10.2337/dc08-0545 · Cited by 1,812
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Self-citationValidation of Time in Range as an Outcome Measure for Diabetes Clinical Trials
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., Kollman, C., Li, Z., Brown, A. S., & Close, K. L. (2019) · Diabetes Care · doi:10.2337/dc18-1444 · Cited by 793
Self-citationGlucose management indicator (GMI): a new term for estimating A1C from continuous glucose monitoring
Bergenstal, R. M., Beck, R. W., Close, K. L., Grunberger, G., Sacks, D. B., Kowalski, A., Brown, A. S., Heinemann, L., Aleppo, G., Ryan, D. B., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1581 · Cited by 684
Self-citationHeinemann, L., Freckmann, G., Ehrmann, D., Faber-Heinemann, G., Guerra, S., Waldenmaier, D., & Hermanns, N. (2018) · The Lancet · doi:10.1016/s0140-6736(18)30297-6 · Cited by 522
Lu, J., Ma, X., Zhou, J., Zhang, L., Mo, Y., Ying, L., Lu, W., Zhu, W., Bao, Y., Vigersky, R. A., et al. (2018) · Diabetes Care · doi:10.2337/dc18-1131 · Cited by 517
The fallacy of average: how using HbA1c alone to assess glycemic control can be misleading
Beck, R. W., Connor, C. G., Mullen, D. M., Wesley, D. M., & Bergenstal, R. M. (2017) · Diabetes Care · doi:10.2337/dc17-0636 · Cited by 477
Self-citationThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Research works printed but not linked: 1
- Peters AL, Paper presented at: European Association for the Study of Diabetes Meeting
Cited by
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,237
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s006 · Cited by 1,403
“Published data suggest a strong correlation between TIR and A1C, with a goal of 70% TIR aligning with an A1C of 7% in two prospective studies (8,25).”
Background6. Glycemic Targets: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s006 · Cited by 847
6. Glycemic Targets: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s006 · Cited by 744
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
“Although HbA1c is an indicator of mean glucose, it does not inform glycemic variability and hypoglycemia and, therefore, is inappropriate as the only method of glucose evaluation in type 1 diabetes (68,69).”
6. Glycemic Targets: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s006 · Cited by 684
6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s006 · Cited by 486
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
6. Glycemic Goals and Hypoglycemia: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s006 · Cited by 440
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
Samson, S. L., Vellanki, P., Blonde, L., Christofides, E. A., Galindo, R. J., Hirsch, I. B., Isaacs, S. D., Izuora, K. E., Low Wang, C. C., Twining, C. L., et al. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.02.001 · Cited by 375
Maiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364
“relations between TIR andmicrovascular complications of diabetes (37,38) as well as HbA1c levels(39,40).”
BackgroundYapanis, M., James, S., Craig, M. E., O’Neal, D., & Ekinci, E. I. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac034 · Cited by 291
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
“…in commercial software for CGM data processing.111e113 Table 3 Estimates of Percentage of Time in Range relative to A1C and Average Glucose Beck 2019 (N ¼ 455 participants with T1D) Vigersky 2019 (N ¼ 1137 participants with T1D or T2D) Average - Beck and Vigersky %TIR 70‒180 mg/dL A1C, %…”
MethodInfluentialSelf-citationLu, J., Wang, C., Shen, Y., Chen, L., Zhang, L., Cai, J., Lu, W., Zhu, W., Hu, G., Xia, T., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1862 · Cited by 282
“(22) in 545 adults with type 1 diabetes (mean glucose: rs 5 0.”
BackgroundCarlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230
Self-citationTime in Range Is Associated with Carotid Intima-Media Thickness in Type 2 Diabetes
Lu, J., Ma, X., Shen, Y., Wu, Q., Wang, R., Zhang, L., Mo, Y., Lu, W., Zhu, W., Bao, Y., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0251 · Cited by 227
“More recently, Beck et al. 19 reported similar results utilizing the datasets from four RCTs conducted in adults with type 1 diabetes.”
6. Glycemic Goals, Hypoglycemia, and Hyperglycemic Crises: Standards of Care in Diabetes-2026.
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s006 · Cited by 172
Positioning time in range in diabetes management
Advani, A. (2020) · Diabetologia · doi:10.1007/s00125-019-05027-0 · Cited by 170
Managing New-Onset Type 1 Diabetes During the COVID-19 Pandemic: Challenges and Opportunities
Garg, S. K., Rodbard, D., Hirsch, I. B., & Forlenza, G. P. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0161 · Cited by 153
“TIR is nearly linearly related to A1C based on analysis of data from multiple studies.(50,51) The correlation between TIR and A1C can also be predicted theoretically.”
Self-citationAdolfsson, P., Hartvig, N. V., Kaas, A., Møller, J. B., & Hellman, J. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0411 · Cited by 139
“8% (5–9 mmol/mol).(28,29) Therefore, even small improvements in TIR can yield corresponding improvements in HbA1c, and result in clinically significant benefits.”
BackgroundContinuous glucose monitoring: The achievement of 100 years of innovation in diabetes technology
Galindo, R. J., & Aleppo, G. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108502 · Cited by 133
Sherr, J. L., Heinemann, L., Fleming, G. A., Bergenstal, R. M., Bruttomesso, D., Hanaire, H., Holl, R. W., Petrie, J. R., Peters, A. L., & Evans, M. (2022) · Diabetes Care · doi:10.2337/dci22-0018 · Cited by 136
“Importantly, even a 5% increase in TIR is deemed clinically significant [14].”
BackgroundSelf-citationSherr, J. L., Heinemann, L., Fleming, G. A., Bergenstal, R. M., Bruttomesso, D., Hanaire, H., Holl, R. W., Petrie, J. R., Peters, A. L., & Evans, M. (2023) · Diabetologia · doi:10.1007/s00125-022-05744-z · Cited by 123
“Importantly, even a 5% increase in TIR is deemed clinically significant (14).”
BackgroundSelf-citationBAJAJ, H. S., Bergenstal, R. M., Christoffersen, A., Davies, M. J., Gowda, A., Isendahl, J., Lingvay, I., Senior, P. A., Silver, R., Trevisan, R., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2877 · Cited by 132
Self-citationContinuous glucose monitoring for the routine care of type 2 diabetes mellitus
Ajjan, R. A., Battelino, T., Cos, X., Del Prato, S., Philips, J.-C., Meyer, L., Seufert, J., & Seidu, S. (2024) · Nature Reviews Endocrinology · doi:10.1038/s41574-024-00973-1 · Cited by 117
Malahi, A. E., Elsen, M. V., Charleer, S., Dirinck, E. L., Ledeganck, K. J., Keymeulen, B., Crenier, L., Radermecker, R. P., Taes, Y., Vercammen, C., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab688 · Cited by 131
Raj, R., Mishra, R., Jha, N., Joshi, V. R., Correa, R. R., & Kern, P. A. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002573 · Cited by 125
“Therefore, a larger-scale multicenter investigation that includes more diverse participants is warranted to further validate the association between CGM-derived TIR and microvascular complications among patients with T2DM.”
Yoo, J. H., Choi, M. S., Ahn, J., Park, S. W., Kim, Y., Hur, K. Y., Jin, S.-M., Kim, G., & Kim, J. H. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0499 · Cited by 98
“24 They even further reported the similar correlations of TIR of 70–180 mg/dL and TAR > 180 mg/dL with HbA1c.”
Lingvay, I., Buse, J. B., Franek, E., Hansen, M. V., Koefoed, M. M., Mathieu, C., Pettus, J., Stachlewska, K., & Rosenstock, J. (2021) · Diabetes Care · doi:10.2337/dc20-2878 · Cited by 110
Time in Range from Continuous Glucose Monitoring: A Novel Metric for Glycemic Control
Yoo, J. H., & Kim, J. H. (2020) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2020.0257 · Cited by 107
“7 by Spearman correlation) was found with HbA1c [22].”
BackgroundMethodResultInfluentialThe Artificial Pancreas and Type 1 Diabetes
Nwokolo, M., & Hovorka, R. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad068 · Cited by 119
“In a multicenter RCT of the Medtronic 780 g advanced hybrid closed-loop versus multiple daily injections of insulin plus intermittently scanned glucose monitoring conducted by Choudhary et al, a greater HbA1c reduction was seen with the hybrid closed-loop ( − 1.42% P .0001) ( 20).”
BackgroundInfluentialFerreira, R. O. M., Trevisan, T., Pasqualotto, E., Chavez, M. P., Marques, B. F., Lamounier, R. N., & van de Sande-Lee, S. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0390 · Cited by 92
Bergenstal, R. M., Mullen, D. M., Strock, E., Johnson, M. L., & Xi, M. X. (2022) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2021.108106 · Cited by 87
Self-citationMeulemeester, J. D., Charleer, S., Visser, M. M., Block, C. E. M. D., Mathieu, C., & Gillard, P. (2024) · Diabetologia · doi:10.1007/s00125-024-06171-y · Cited by 89
“[8].”
A Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials
Spanakis, E. K., Cook, C. B., Kulasa, K. M., Aloi, J., Bally, L., Davis, G. M., Dungan, K. M., Galindo, R. J., Mendez, C. E., Pasquel, F. J., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231191104 · Cited by 92
Forlenza, G. P., Buckingham, B. A., Brown, S. A., Bode, B. W., Levy, C. J., Criego, A. B., Wadwa, R. P., Cobry, E. C., Slover, R. J., Messer, L. H., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0546 · Cited by 78
Karges, B., Tittel, S. R., Bey, A., Freiberg, C., Klinkert, C., Kordonouri, O., Thiele‐Schmitz, S., Schröder, C., Steigleder‐Schweiger, C., & Holl, R. W. (2023) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(23)00061-x · Cited by 91
Jiao, X., Shen, Y., & Chen, Y. (2022) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002633 · Cited by 76
“35 However, a decrease of only 0.3 percentile was shown in this meta-analysis.”
InfluentialMoon, J. S., Kang, S., Choi, J. H., Lee, K. A., Moon, J. H., Chon, S., Kim, D. J., Kim, H. J., Seo, J. A., Kim, M. K., et al. (2024) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2024.0249 · Cited by 90
Rodbard, D. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0440 · Cited by 75
“This is one reason that the percentiles on the Ambulatory Glucose Profile displaying percentiles can be more informative and useful in clinical decision making than a display of the mean – 1 SD or mean – 2 SD. 33–35 Need for additional studies to characterize the nature of the glucose distribution The nature of the rel…”
InfluentialSelf-citationShah, V. N., Kanapka, L. G., Aktürk, H. K., Polsky, S., Forlenza, G. P., Kollman, C., Beck, R. W., & Snell‐Bergeon, J. K. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0486 · Cited by 79
“Spearman correlations of TIR, TITR, TAR, and mean glucose with each other were all ‡ 0.97.”
InfluentialSelf-citationMissed and Mistimed Insulin Doses in People with Diabetes: A Systematic Literature Review
Robinson, S., Newson, R. S., Liao, B., Kennedy-Martin, T., & Battelino, T. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0164 · Cited by 73
A Comparative Analysis of Glycemic Metrics Derived From Three Continuous Glucose Monitoring Systems
Freckmann, G., Wehrstedt, S., Eichenlaub, M., Pleus, S., Link, M., Jendrike, N. R. M., Öter, Ş., Brandt, D., Haug, C., & Waldenmaier, D. (2025) · Diabetes Care · doi:10.2337/dc25-0129 · Cited by 89
Recent Updates to Clinical Practice Guidelines for Diabetes Mellitus
Yu, J., Lee, S.-H., & Kim, M. K. (2022) · Endocrinology and Metabolism · doi:10.3803/enm.2022.105 · Cited by 65
“A1C is an indicator of mean glucose levels, but it does not reflect glycemic variability and hypoglycemia [58,59].”
BackgroundPease, A., Lo, C., Earnest, A., Kiriakova, V., Liew, D., & Zoungas, S. (2020) · Diabetes Care · doi:10.2337/dc19-1785 · Cited by 70
Brener, A., Mazor‐Aronovitch, K., Rachmiel, M., Levek, N., Barash, G., Pinhas‐Hamiel, O., Lebenthal, Y., & Landau, Z. (2020) · Acta Diabetologica · doi:10.1007/s00592-020-01596-4 · Cited by 64
Standardization process of continuous glucose monitoring: Traceability and performance
Freckmann, G., Nichols, J. H., Hinzmann, R., Klonoff, D. C., Ju, Y., Diem, P., Makris, K., & Slingerland, R. J. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.12.025 · Cited by 62
Semaglutide in Adults with Type 1 Diabetes and Obesity
Shah, V. N., Akturk, H. K., Kruger, D., Ahmann, A., Bhargava, A., Bakoyannis, G., Pyle, L., & Snell-Bergeon, J. K. (2025) · NEJM Evidence · doi:10.1056/evidoa2500173 · Cited by 62
Monnier, L., Wojtusciszyn, A., Molinari, N., Colette, C., Renard, É., & Owens, D. R. (2020) · Diabetes Care · doi:10.2337/dc19-1549 · Cited by 68
Fabris, C., Heinemann, L., Beck, R., Cobelli, C., & Kovatchev, B. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0236 · Cited by 58
“With the growing adoption of CGM as a diagnostic option for diabetes therapy, TIR has been recognized as an important metric to complement (or even replace) HbA1c, which can provide a complete picture of an individual’s glucose control over time if combined with an indicator of exposure to hypo- or hyperglycemia.(18,3…”
ResultSelf-citationFast-Acting Insulin Aspart Use with the MiniMed TM 670G System
Hsu, L., Buckingham, B., Basina, M., Ekhlaspour, L., von Eyben, R., Wang, J., & Lal, R. A. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0083 · Cited by 57
Beato-Víbora, P. I., Chico, A. I., Moreno-Fernández, J., Bellido, V., Nattero‐Chávez, L., César, M. J. P., Martínez‐Brocca, M. A., Giménez, M., Aguilera, E., Climent, E., et al. (2023) · Diabetes Care · doi:10.2337/dc23-1355 · Cited by 60
Monitoring of Pediatric Type 1 Diabetes
Marks, B. E., & Wolfsdorf, J. I. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00128 · Cited by 71
“While it is wellrecognized that attaining these targets is challenging for many patients, nonetheless, the potential benefit of small improvements should be emphasized: a 5% increase in TIR has been linked to significant improvements in overall glycemic control (84, 85).”
BackgroundAlharthi, S. K., Alyusuf, E. Y., Alguwaihes, A. M., Alfadda, A. A., & Al‐Sofiani, M. E. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108682 · Cited by 56
“[14] Beck RW, Bergenstal RM, Cheng P, Kollman C, Carlson AL, Johnson ML, et al.”
Wilmot, E. G., Lumb, A. N., Hammond, P. J., Murphy, H. R., SCOTT, E. M., Gibb, F. W., Platts, J. K., & Choudhary, P. (2020) · Diabetic Medicine · doi:10.1111/dme.14433 · Cited by 57
“[29] examined a variety of CGM metrics and their correlation with long-term glycaemia, as measured by HbA1c.”
BackgroundInfluentialClinical recommendations for the use of the ambulatory glucose profile in diabetes care
Kröger, J., Reichel, A., Siegmund, T., & Ziegler, R. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819883032 · Cited by 51
“There is evidence of an association between the TIR and clinical trial outcomes.(13,16,17,36,37) However, the evidence associating TIR with diabetes outcomes is still limited, meaning that additional reports on clinical experience with this measure of glycemic control will be important for verifying these recommendati…”
BackgroundLu, J., Ma, X., Zhang, L., Mo, Y., Lu, W., Zhu, W., Bao, Y., Jia, W., & Zhou, J. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108032 · Cited by 49
Emerging Diabetes Technologies: Continuous Glucose Monitors/Artificial Pancreases
ALMURASHI, A. M., Rodriguez, E., & Garg, S. K. (2023) · Journal of the Indian Institute of Science · doi:10.1007/s41745-022-00348-3 · Cited by 66
Diabetes education in pediatrics: How to survive diabetes
Ergun-Longmire, B., Clemente, E. G., Maravolo, P. V., Roberts, C., Buth, K., & Greydanus, D. E. (2021) · Disease-a-Month · doi:10.1016/j.disamonth.2021.101153 · Cited by 54
Time-in-range for monitoring glucose control: Is it time for a change?
Bellido, V., Pinés-Corrales, P. J., Villar‐Taibo, R., & Ampudia‐Blasco, F. J. (2021) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2021.108917 · Cited by 52
Continuous Glucose Monitoring for Prediabetes: What Are the Best Metrics?
Zahalka, S. J., Galindo, R. J., Shah, V. N., & Wang, C. C. L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241242487 · Cited by 232
“Each 5% increment in time spent in the target range 70 to 180 mg/dl is extrapolated to correlate with a reduction in A1c by 0.4%, 21 which is associated with clinically significant benefits for individuals with type 1 diabetes mellitus and T2DM.20 For GV, the consensus statement established a goal…”
InfluentialBraune, K., Boß, K., Schmidt-Herzel, J., Gajewska, K. A., Thieffry, A., Schulze, L., Posern, B., & Raile, K. (2020) · JMIR mhealth and uhealth · doi:10.2196/24374 · Cited by 55
Rodbard, D. (2022) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14906 · Cited by 47
“Table 3) and Figure S1 (panels E and F) of the supplementary materials in Beck et al.(14)”
BackgroundMethodInfluentialSelf-citationSandig, D., Grimsmann, J., Reinauer, C., Melmer, A., Zimny, S., Müller-Korbsch, M., Forestier, N., Zeyfang, A., Bramlage, P., Danne, T., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0019 · Cited by 43
Friedman, J. G., Cardona, Z., Szmuilowicz, E. D., & Aleppo, G. (2023) · Pharmacogenomics and Personalized Medicine · doi:10.2147/pgpm.s374663 · Cited by 60
“While HbA1c is the well-understood “goldstandard” for diabetes monitoring and diagnosis, CGM metrics such as TIR or GMI do not perfectly correlate with HbA1c, and all measures of glycemia should be evaluated in the context of one another when taking care of a patient with diabetes.(64) Additionally, while the COVID-19…”
BackgroundKang, S., Kang, S. M., Choi, J. H., Ko, S., Koo, B. K., Kwon, H.-S., Kim, M. K., Kim, S. Y., Kim, S., Kim, Y., et al. (2025) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2025.0469 · Cited by 84
Wright, E. E., Morgan, K., Fu, D. K., Wilkins, N., & Guffey, W. J. (2020) · Clinical Diabetes · doi:10.2337/cd20-0042 · Cited by 40
“, as TIR increases, A1C decreases and vice versa) (36), the extent of the correlation between TIR and A1C is not fully apparent.”
BackgroundBergenstal, R. M., HACHMANN-NIELSEN, E., Kvist, K., Peters, A. L., Tarp, J. M., & Buse, J. B. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0447 · Cited by 46
“5% improvement in HbA1c.(12,13) In addition to measurement using CGM, derived TIR (dTIR) may be estimated from self-measured blood glucose (SMBG) profiles.”
MethodInfluentialSelf-citationReddy, M., & Oliver, N. S. (2024) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15504 · Cited by 47
“31,32”
New and Emerging Technologies in Type 1 Diabetes
Sherwood, J. S., Russell, S. J., & Putman, M. S. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2020.07.006 · Cited by 49
“TIR has been suggested as a new treatment standard based on the argument that TIR is easier for people with diabetes to understand and is more actionable on a day-to-day basis.(2,10) Targets for time below range (TBR) and time above range (TAR) have also been established (Table 1).”
BackgroundGlucose measurement in body fluids: A ready reckoner for clinicians
Kubihal, S., Goyal, A., Gupta, Y., & Khadgawat, R. (2020) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2020.11.021 · Cited by 47
Ehrmann, D., SCHMITT, A. J., Priesterroth, L., Kulzer, B., Haak, T., & Hermanns, N. (2022) · Diabetes Care · doi:10.2337/dc21-2339 · Cited by 44
Impact of digital health interventions on glycemic control and weight management.
Veluvali, A., Dehghani Zahedani, A., Hosseinian, A., Aghaeepour, N., McLaughlin, T., Woodward, M., DiTullio, A., Hashemi, N., & Snyder, M. P. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01430-7 · Cited by 45
“For individuals with Type 1 and Type 2 diabetes, optimal TIR is > 70%; each additional 5% increase in TIR is associated with clinically signi fi cant bene fi ts for those populations 20,21 .”
Time in range in pregnancy: is there a role?
Wyckoff, J. A., & Brown, F. M. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0103 · Cited by 39
Bellido, V., Aguilera, E., Cardona‐Hernandez, R., Díaz-Soto, G., de Villar, N. G. P., César, M. J. P., & Ampudia‐Blasco, F. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221088601 · Cited by 46
“17(5) 1326 –1336 © 2022 Diabetes Technology Society Article reuse guidelines: sagepub.”
BackgroundInfluentialManipulation of Post-Prandial Hyperglycaemia in Type 2 Diabetes: An Update for Practitioners
Shibib, L., Al-Qaisi, M., Guess, N. D., Miras, A. D., Greenwald, S. E., Pelling, M., & Ahmed, A. (2024) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s458894 · Cited by 48
Leveraging advances in diabetes technologies in primary care: a narrative review
Bode, B. W., King, A., Russell-Jones, D. L., & Billings, L. K. (2021) · Annals of Medicine · doi:10.1080/07853890.2021.1931427 · Cited by 46
“In the T1D cohort of DIAMOND, reductions in HbA1c were independent of participant age, education level, and baseline HbA1c [27].”
BackgroundInfluentialTime-in-range as a target in type 2 diabetes: An urgent need
Saboo, B., Kesavadev, J., Shankar, A., Krishna, M. B., Sheth, S., Patel, V., & Krishnan, G. (2021) · Heliyon · doi:10.1016/j.heliyon.2021.e05967 · Cited by 44
“5% HbA1c reduction in both Type 1 diabetes (T1D) and T2D patients [10, 11].”
BackgroundThe Association of Time in Range and Diabetic Complications: The Evidence Is Strong
Beck, R. W. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0141 · Cited by 37
Self-citationGomez-Peralta, F., Abreu, C., Fernández-Rubio, E., Cotovad, L., Pujante, P., Gaztambide, S., Bellido, D., Menéndez Torre, E., Ruiz-Valdepeñas, S., Bello, H., et al. (2023) · Diabetes Care · doi:10.2337/dc22-0525 · Cited by 36
“3% GMI decrease found in our study is considered clinically relevant (6).”
BackgroundPAULEY, M. E., Tommerdahl, K. L., Snell‐Bergeon, J. K., & Forlenza, G. P. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01799-x · Cited by 46
Benhamou, P., Adenis, A., Lebbad, H., Tourki, Y., Heredia, M., Gehr, B., Franc, S., & Charpentier, G. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.15008 · Cited by 35
“Among the CAS population, we computed an expected TIR based on a previously published formula using the HbA1c of the patient before the use of the DBLG1 system.(11) This formula {TIR (%)= [HbA1c (%) 9.”
MethodLow carbohydrate high fat ketogenic diets on the exercise crossover point and glucose homeostasis
Noakes, T. D., Prins, P. J., Volek, J. S., D’Agostino, D. P., & Koutnik, A. P. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1150265 · Cited by 33
“…readings (10–14 days) are good estimates of 3-month continuous glucose monitoring averages (Chehregosha et al., 2019), and emergent evidence suggest that continuous glucose monitoring metrics track better with mean glucose (r = 0.92–0.98) than HbA1c (r = 0.71) in larger trails (Beck et al., 2019).”
BackgroundInfluentialValenzano, M., Cibrario Bertolotti, I., Valenzano, A., & Grassi, G. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001045 · Cited by 34
“Differently from other works based on randomized studies, such as Vigersky and McMahon, 17 Beck et al , 18 and Petersson et al , 19 our investigations were based on pure 1-year observations of 70 patients with type 1 diabetes adopting CGM in Emerging technologies, pharmacology and therapeutics…”
InfluentialKovatchev, B. P., Lobo, B. J., Fabris, C., Ganji, M., Fathi, A. E., Breton, M. D., Kanapka, L. G., Kollman, C., Battelino, T., & Beck, R. W. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0404 · Cited by 37
Self-citationLandstra, C. P., Andrès, A., Chetboun, M., Conte, C., Kelly, Y. M., Berney, T., de Koning, E. J. P., Piemonti, L., Stock, P. G., Pattou, F. N., et al. (2021) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab386 · Cited by 38
Time in Tight Range for Patients With Type 1 Diabetes: The Time Is Now, or Is It Too Soon?
Hamidi, V., & Pettus, J. (2024) · Diabetes Care · doi:10.2337/dci23-0092 · Cited by 38
Aronson, R., Abitbol, A., Bajaj, H. S., Cheng, A. Y. Y., Christopoulos, S., Harris, S. B., Jain, A. B., & Goldenberg, R. M. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.70008 · Cited by 33
Gal, R. L., Cohen, N. J., Kruger, D., Beck, R. W., Bergenstal, R. M., Calhoun, P., Cushman, T., Haban, A., Hood, K., Johnson, M. L., et al. (2020) · Journal of the Endocrine Society · doi:10.1210/jendso/bvaa076 · Cited by 32
“Baseline percentage time in range and mean glucose were estimated from HbA 1c [26].”
MethodSelf-citationKalra, S., Shaikh, S. S., Priya, G., Baruah, M., Verma, A., Das, A. K., Shah, M., Das, S., Khandelwal, D., Sanyal, D., et al. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00973-0 · Cited by 37
Sheng, X., Xiong, G., Yu, P., & Liu, J.-P. (2020) · International Journal of Endocrinology · doi:10.1155/2020/8879085 · Cited by 35
“In addition, 7 points of data may not include information from overnight periods, whichmay lead to underestimation of TIR; however, this is not likely to impact the association of TIR with diabetic complications [12].”
BackgroundKim, M. Y., Kim, G., Park, J. Y., Choi, M. S., Jun, J. E., Lee, Y.-B., Jin, S.-M., Hur, K. Y., & Kim, J. H. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0599 · Cited by 30
“…and McMahon 23 analyzed 18 randomized controlled trials, which included 2577 patients with type 1 diabetes and type 2 diabetes, reported a strong correlation between HbA1c and TIR 70–180 mgl/dL, while Beck et al. 24 found that a 10% increase in the TIR 70–180 mg/dL decreased the mean A1c by 0.6%.”
InfluentialIntralymphatic GAD-Alum (Diamyd®) Improves Glycemic Control in Type 1 Diabetes With HLA DR3-DQ2
Nowak, C., Lind, M., Šumník, Z., Pelikánová, T., Nattero‐Chávez, L., Lundberg, E., Rica, I., Martínez‐Brocca, M. A., de Adana, M. R., Wahlberg, J., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac343 · Cited by 39
“TIR is associated with HbA1c (13, 14) and diabetic complications (15, 16).”
BackgroundGubitosi-Klug, R. A., Braffett, B. H., Bebu, I., Johnson, M. L., Farrell, K., Kenny, D., Trapani, V. R., Meadema-Mayer, L., Soliman, E. Z., Pop-Busui, R., et al. (2022) · Diabetes Care · doi:10.2337/dc21-0629 · Cited by 31
Self-citationCarlson, A. L., Criego, A. B., Martens, T. W., & Bergenstal, R. M. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.010 · Cited by 33
Self-citationLong Term HbA1c Prediction Using Multi-Stage CGM Data Analysis
Islam, M. S., Qaraqe, M., Belhaouari, S. B., & Petrovski, G. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3073974 · Cited by 34
Clinical Application of Time in Range and Other Metrics
Aleppo, G. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0093 · Cited by 35
Distinct patterns of daily glucose variability by pubertal status in youth with type 1 diabetes
Zhu, J., Volkening, L. K., & Laffel, L. M. (2020) · Diabetes Care · doi:10.2337/dc19-0083 · Cited by 30
Pai, A., Santiago, R., GLANTZ, N. M., Bevier, W. C., Barua, S., Sabharwal, A., & Kerr, D. E. (2024) · npj Digital Medicine · doi:10.1038/s41746-023-00985-7 · Cited by 36
“The median adherence in days for MyFitnessPal meal logging was 13 [interquartile range (IQR): 9 – 14]; for CGM, 13 [IQR: 13 – 13] adherence was 11 [IQR: 5 – 13] days.”
Metadata
- Authors
- Beck, R. W., Bergenstal, R. M., Cheng, P., Kollman, C., Carlson, A. L., Johnson, M. L., & Rodbard, D.
- Affiliations
- Jaeb Center for Health Research (US)
- Park Nicollet Clinic (US)
- Biomedical Informatics Consultants, LLC, Potomac, MD, USA
- Corresponding author
- Beck, Roy W.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2019-01-13
- Volume
- 13
- Issue
- 4
- Pages
- 614-626
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6610606
- OpenAlex
- W2910274134
- Semantic Scholar
- 5dcb6eaae421097f5303338e5e6ad5f5808ef649
- Cited by
- 479
- References
- 29
- Citations by year
- 2026: 53 · 2025: 60 · 2024: 62 · 2023: 66 · 2022: 72 · 2021: 80 · 2020: 71 · 2019: 15
- FWCI
- 48.30
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Jaeb Center for Research Foundation
- Sanofi
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- time in range, HbA1c, continuous glucose monitoring, type 1 diabetes, glycemic control, mean blood glucose
- MeSH terms
- Adolescent, Adult, Aged, Blood Glucose, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hyperglycemia, Male, Middle Aged, Blood Glucose Self-Monitoring, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.