Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline
Open accessThe DOI matches its Crossref record; 128 of the 128 references it cites were found in a registry or an index.
Abstract
This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Studies have been published assessing the effectiveness of this approach, which may ultimately lead to the approved use of CGM for monitoring hospitalized individuals (277,286-295).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [277]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Similarly, data are emerging on the inpatient use of AID systems and their challenges (277,296,297).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [277]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Because up to 40% to 50% of persons admitted with stress-related hyperglycemia have confirmed DM at 1 year they should be closely monitored after discharge.1378,1379”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1379]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U.S. Department of Health and Human Services FDA Center for Drug Evaluation and Research, U.S. Department of Health and Human Services FDA Center for Biologics Evaluation and Research, & U.S. Department of Health and Human Services FDA Center for Devices and Radiological Health (2006) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-4-79 · Cited by 2,856
Work system design for patient safety: the SEIPS model
Carayon, P., Schoofs Hundt, A., Karsh, B.-T., Gurses, A. P., Alvarado, C. J., Smith, M., & Flatley Brennan, P. (2006) · Quality in Health Care · doi:10.1136/qshc.2005.015842 · Cited by 1,795
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Intravascular Complications of Central Venous Catheterization by Insertion Site
Parienti, J.-J., Mongardon, N., Mégarbane, B., Mira, J.-P., Kalfon, P., Gros, A., Marqué, S., Thuong, M., Pottier, V., Ramakers, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500964 · Cited by 769
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Outcomes in Patients With Hyperglycemia Affected by COVID-19: Can We Do More on Glycemic Control?
Sardu, C., D’Onofrio, N., Balestrieri, M. L., Barbieri, M., Rizzo, M. R., Messina, V., Maggi, P., Coppola, N., Paolisso, G., & Marfella, R. (2020) · Diabetes Care · doi:10.2337/dc20-0723 · Cited by 424
Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital
Umpierrez, G. E., & Klonoff, D. C. (2018) · Diabetes Care · doi:10.2337/dci18-0002 · Cited by 251
Self-citationFundamentals of Clinical Data Science
(2019) · Springer eBooks · doi:10.1007/978-3-319-99713-1 · Cited by 235
Closed-loop insulin delivery for glycemic control in noncritical care
Bally, L., Thabit, H., Hartnell, S., Andereggen, E., Ruan, Y., Wilinska, M. E., Evans, M. L., Wertli, M. M., Coll, A. P., Stettler, C., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805233 · Cited by 232
Self-citationReal-Time Continuous Glucose Monitoring in Critically Ill Patients
Holzinger, U., Warszawska, J., Kitzberger, R., Wewalka, M., Miehsler, W., Herkner, H., & Madl, C. (2010) · Diabetes Care · doi:10.2337/dc09-1352 · Cited by 212
Research works printed but not linked: 3
- 49. Galindo RJ, Umpierrez GE. Management of diabetes and/or hyperglycemia in non-critical care hospital settings. In: Matfin G (ed.) Endocrine and Metabolic Medical Emergencies . Hoboken, BJ: John Wiley & Sons, Ltd; 2018:491-505.
- 148. Revision of the 'guideline of the German medical association on quality assurance in medical laboratory examinations - Rili-BAEK' (unauthorized translation). J Lab Med . 2015;39(1):26-69.
- 149. United States Supreme Court. Official Reports of the Supreme Court . Vol 531 Part 2. (Wagner FD, ed.). Supreme Court; 2001.
Cited by
Items 101–170 of 170
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2025) · Diabetes aktuell · doi:10.1055/a-2500-1766 · Cited by 5
Salmen, B.-M., Reurean‐Pintilei, D., Trofin, D., Durdu, C.-E., Neagu, A., & Bohîlțea, R. E. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26073022 · Cited by 4
“Currently, GDM monitoring is primarily conducted through the self-monitoring of blood glucose (SMBG) and continuous glucose monitoring systems (CGMSs) [26,27].”
Preoperative optimization of diabetes
Stewart, E., & Selzer, A. R. (2021) · International Anesthesiology Clinics · doi:10.1097/aia.0000000000000351 · Cited by 3
“In patients requiring imaging such as magnetic resonance imaging, computed tomography scans, or x-rays, attention should be paid to manufacturer’s safety and use information, as some manufacturers recommend covering or removing pumps in certain situations.(88)”
BackgroundMethodMüssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2024) · Diabetologie und Stoffwechsel · doi:10.1055/a-2312-1160 · Cited by 3
“…im Krankenhaus sind Medikamente wie GC, die eine ausgeprägte Insulinresistenz mit konsekutiver Hyperglykä-mie verursachen können, Übelkeit und Erbrechen sowie eine pa-renterale oder enterale Ernährung über eine nasogastrale Sonde oder perkutane endoskopische Gastrostomie (PEG) [67].”
Hospital Diabetes Meeting 2022
Huang, J. K., Yeung, A. M., Nguyen, K. T., Xu, N. Y., Preiser, J., Rushakoff, R. J., Seley, J. J., Umpierrez, G. E., Wallia, A., Drincic, A., et al. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221110878 · Cited by 4
“37 Physicians and nurses need to be confident about the accuracy, efficacy, and safety of the CGMs. Capturing reductions in POC testing and staff time can convince hospital administrators and medical officers of the cost-effectiveness of CGM intervention, which may lead to improved outcomes and…”
BackgroundSelf-citationInpatient Use of Automated Insulin Delivery Systems
Chadalawada, L., Parab, R., Feeley, J. M., Hughes, M. S., Pasquel, F. J., & Davis, G. M. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251412442 · Cited by 4
“15,25,27,28 Notably, many patients using AID systems in the outpatient setting have experience adjusting device settings to their own needs, which may be advantageous during hospitalization.”
Wang, R., Krishnamoorthi, B., Connell, A., Chiang, C. Y., Renouf, D., Barmanray, R., Kyi, M., & Fourlanos, S. (2025) · Internal Medicine Journal · doi:10.1111/imj.70095 · Cited by 2
Continuous Glucose Monitoring in Hospital Settings
Faulds, E. R., & Hughes, M. S. (2025) · Medical Clinics of North America · doi:10.1016/j.mcna.2025.11.008 · Cited by 2
McGill, J. B., Donihi, A. C., Aktürk, H. K., Freeby, M., Gupta, A., Horton, W. B., Jadoon, M. N., Lathief, S., Miracle-López, S., Tan, C., et al. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.06.011 · Cited by 3
Self-citationSoftware Architecture of Automated Devices: Formation and Evaluation
Buiak, L., Hordei, O., Hurochkina, V., Patsai, B., Nechyporuk, I., & Hurochkin, A. (2021) · International Conference on Advanced Computer Information Technologies (ACIT) · doi:10.1109/acit52158.2021.9548458 · Cited by 2
Artificial intelligence in critically ill diabetic patients: current status and future prospects
Juneja, D., Gupta, A., & Singh, O. (2022) · Artificial Intelligence in Gastroenterology · doi:10.35712/aig.v3.i2.66 · Cited by 3
Zilbermint, M. F. (2022) · Diabetes Spectrum · doi:10.2337/dsi22-0014 · Cited by 2
Clinical Practice Update: Inpatient Insulin Pump and Integrated Insulin Delivery Systems
Nguyen, S., Davis, G. M., & Vasudevan, M. M. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_7 · Cited by 2
Medina, A. M. G., Carrillo, D. C. H., Ré, M., Faradji, R. N., Flores‐Caloca, Ó., la Garza-Hernández, N. E. D., Ferreira, C. A., Garnica-Cuéllar, J. C., Krakauer, M., & Galindo, R. J. (2024) · Diabetology & Metabolic Syndrome · doi:10.1186/s13098-024-01362-4 · Cited by 2
“” Inclusion criteria were established to select guidelines specifically addressing the management of diabetes in a hospital setting [1, 4, 8, 11].”
BackgroundSelf-citationEndocrine Care for the Surgical Patient
Mendez, C. E., Shiffermiller, J. F., Razzeto, A., & Hannoush, Z. C. (2024) · Medical Clinics of North America · doi:10.1016/j.mcna.2024.04.007 · Cited by 2
Hospital care: improving outcomes in type 1 diabetes
BOEDER, S. C., & Kulasa, K. M. (2020) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000601 · Cited by 3
Fagher, K., Ekström, E., Rystedt, J. L., Tingstedt, B., Andersson, B., & Löndahl, M. (2023) · Acta Diabetologica · doi:10.1007/s00592-023-02158-0 · Cited by 3
“However, CGMs are developed for out-patient settings, and a recent consensus document evaluating the in-hospital use pointed out potential advantages but also barriers, concluding that CGMs cannot replace POC testing when monitoring blood glucose in the hospital [13].”
BackgroundGiannella, A. D., Cavaiola, T. S., & Kulasa, K. M. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_4 · Cited by 2
Continuous glucose monitoring in pregnancy
Novaković, I. V., Todorović, J., Dugalić, S., Macura, M., Milinčić, M., & Gojnić-Dugalić, M. (2024) · Srpski arhiv za celokupno lekarstvo · doi:10.2298/sarh240104028n · Cited by 2
Using Diabetes Technology in Hospitalized Patients
McCrea, D. L. (2024) · Critical Care Nursing Clinics of North America · doi:10.1016/j.cnc.2024.07.001 · Cited by 1
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2025) · Die Diabetologie · doi:10.1007/s11428-024-01276-9 · Cited by 1
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2025) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/a-2490-5208 · Cited by 1
“…difficult scenarios for hybrid closed-loop systems in hospitals are drugs such as GCs, which can cause pronounced insulin resistance with subsequent hyperglycaemia, nausea and vomiting, and parenteral or enteral nutrition via a nasogastric tube or percutaneous endoscopic gastrostomy (PEG) [67].”
Hochfellner, D. A., Poettler, T., Schöerghuber, M., Lukić, E., Yates, A., Keeling, I. M., Zimpfer, D., Aberer, F., Berti, F., Lucarelli, F., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251342598 · Cited by 4
Yuan, J., Wang, J., Wang, Y., Chen, P., Wu, S., Shen, Y., Zhao, C., Reutrakul, S., Park, C. G., Chen, X., et al. (2025) · Sleep Medicine · doi:10.1016/j.sleep.2025.106754 · Cited by 3
Cook, C. B., Thompson, B., Perrin, A. J., Castro, J. C., McGary, A. K., & Buras, M. R. (2025) · Endocrine Practice · doi:10.1016/j.eprac.2025.09.200 · Cited by 2
Self-citationCai, Q., Zhao, P., Chen, X., Yu, S., Guo, L., & Pan, Q. (2025) · Aging Medicine · doi:10.1002/agm2.70044 · Cited by 3
Lockee, B., Vandervelden, C. A., Tilden, D. R., Panfil, K., Tallon, E. M., DeWit, E., Noland, K., Williams, D. D., Gill, H. S., Patton, S. R., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251367776 · Cited by 3
Self-citationDoherty, T. M., Kelley, A. M., Kim, E., & Salik, I. (2025) · World Journal of Clinical Pediatrics · doi:10.5409/wjcp.v14.i4.107127 · Cited by 1
Santana, D., Mosteiro, A., Pedrosa, L., Pujol-Fontrodona, G., Zattera, L., Werner, M., Ortega, E., Llull, L., Torné, R., & Amaro, S. (2025) · Scientific Reports · doi:10.1038/s41598-025-29495-0 · Cited by 2
Soliman, D., Varghese, R. T., Umpierrez, G. E., & Galindo, R. J. (2025) · Medical Clinics of North America · doi:10.1016/j.mcna.2025.11.006 · Cited by 1
Self-citationPedersen, C., Philipsen, A., Nørgaard, K., Aasvang, E. K., & Meyhoff, C. S. (2026) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.70219 · Cited by 2
Advances in diabetes technology: clinical implications, limitations, and future perspectives
Apostolopoulou, M., & Effraimidis, G. (2026) · HORMONES · doi:10.1007/s42000-026-00797-w · Cited by 2
The diabetes patient for ambulatory surgery
Vann, M. A. (2023) · Best practice & research. Clinical anaesthesiology · doi:10.1016/j.bpa.2023.03.002 · Cited by 1
Malecki, M. T., Klupa, T., Bociąga‐Jasik, M., Kowalska, I., Gumprecht, J., Strojek, K., Zozulińska‐Ziółkiewicz, D., Czupryniak, L., Hohendorff, J., & Kania, M. (2023) · Current Topics in Diabetes · doi:10.5114/ctd/161459 · Cited by 1
Error traps in the perioperative management of children with type 1 diabetes
Hoagland, M., Duggar, B., Hamrick, J., Alonso, G. T., & Martin, L. D. (2023) · Pediatric Anesthesia · doi:10.1111/pan.14763 · Cited by 1
“25 Data related to intraoperative CGM use are limited to small studies and case reports.”
BackgroundNew technology may help perioperative glucose management but not without a dedicated team?
Ylikoski, M., Lahtela, J. T., Jokinen, J. J., Kauppi, M. J., Huhtala, H., Tiihonen, R., & Immonen, H. (2020) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13762
COVID-19 & Inpatient Continuous Glucose Monitoring: A New Opportunity?
Gerard, S. O., & Scher, L. (2021) · ADCES in Practice · doi:10.1177/2633559x20985474
¿Cómo adaptamos la atención hospitalaria en pacientes con hiperglucemia y COVID-19?
Grosembacher, L. (2021) · Revista de la Sociedad Argentina de Diabetes · doi:10.47196/diab.v55i2.477
Berge, T. V. D., Biester, S., Biester, T., Buchmann, A.-K., Datz, N., Grosser, U., Kapitzke, K., Klusmeier, B., Remus, K., Reschke, F., et al. (2022) · Diabetes aktuell · doi:10.1055/a-1851-2883
Integrating diabetes technology data in the EHR
Espinoza, J. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90557-2.00012-1 · Cited by 1
Self-citationMiller, K., Wiencek, C. A., & Ridge, R. J. (2023) · ADCES in Practice · doi:10.1177/2633559x231200017
“…to manage glucose (Foster et al., 2019) • National organizations recommend continuation of diabetes technology during hospitalization (Elsayed et al., 2023; Galindo et al., 2020; Korytkowski et al., 2022) • CGM and AID not FDA approved for inpatient management • Wearable diabetes technology”
BackgroundLiterature Review of Deep Learning for Physiological signal AnalysisPreprint
Ortiz, N., Beleño, R. D. H., Pérez, M. A., & Suárez, P. A. N. (2023) · Authorea · doi:10.22541/au.170121283.33310565/v1
Continuous Glucose Monitoring in the Hospital Setting: Current Status and Future Directions
Davis, G. M., & Vasudevan, M. M. (2023) · Contemporary Endocrinology · doi:10.1007/978-3-031-44648-1_8
Use of a continuous glucose monitoring device: Perceptions of nursing staff
Smith, V. (2024) · Clinical Nursing Studies · doi:10.5430/cns.v12n1p17
Zhang, Y., Zhang, L., Li, G., Lin, C., Zhuang, B., & Yu, S. (2025) · Indian Journal of Surgery · doi:10.1007/s12262-025-04408-7
Redefining inpatient diabetes care: A policy-driven approach to safe and effective technology use
Holliday, M. E., Herbert, L., & Kubas, J. (2025) · Journal of the American Association of Nurse Practitioners · doi:10.1097/jxx.0000000000001209 · Cited by 1
Insulin pumps and artificial pancreas
Markakis, K. P., & Vazeou, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13825-6.00296-x
Insulin Pump Therapy in the Hospital
Thompson, B., Boyle, M. E., & Cook, C. B. (2025) · Medical Clinics of North America · doi:10.1016/j.mcna.2025.11.009
Self-citationJin, J., Wen, S., Liu, H., Chen, L., Ren, Y., Gong, M., Yuan, X., Li, J., & Zhou, L. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1716837
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2026) · Die Diabetologie · doi:10.1007/s11428-026-01424-3
Comprehensive Inpatient Glycemic Management
Khan, S. A., Aasim, A. H., & Spanakis, E. K. (2026) · Medical Clinics of North America · doi:10.1016/j.mcna.2025.11.007
Self-citationDiabetesmanagement im Krankenhaus (Update 2019)
Mader, J. K., Aberer, F., Brix, J. M., Föger, B., Hochfellner, D. A., Kietaibl, A.-T., Ludvik, B., Resl, M., Ress-Winkel, C., Stechemesser, L., et al. (2019) · Wiener klinische Wochenschrift · doi:10.1007/s00508-019-1447-z · Cited by 12
Liu, X., Zheng, D., Yang, Y., XiujuanZhang, M. D., PhD, C., Jin, X., Tian, Z., Dai, A., Xu, C., Xu, F.-Y., et al. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261442573
Amouyal, C., Benhamou, P., Carlier, A., Marchand, L., Smati, S., & Villard, O. (2026) · Médecine des Maladies Métaboliques · doi:10.1016/j.mmm.2026.06.008 · Cited by 1
Mader, J. K., Guerci, B., Alzubaidi, L. M. Y., Alawadi, F., Bally, L., Ehrmann, D., Fernando, K., Gillard, P., Grancini, V., Khunti, K., et al. (2026) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2026.113471
Real-World Outcomes of Automated Insulin Delivery Use in Hospitalized Adults With Diabetes
Ruddiman, K. R., Evans, J. K., Aloi, J., Usoh, C. O., & Price, C. E. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261473583
Sanchez, C. E., Ro, M., & Jones, R. (2026) · Patient Safety · doi:10.33940/001c.163571
Improving Glycemic Safety in Non-ICU Wards With Continuous Glucose Monitoring
Shinde, J. R., Agarwal, N. B., Gangwar, P., & Jhawar, D. M. (2026) · International Journal of Health Sciences and Research · doi:10.52403/ijhsr.20260815
Glucose Monitoring: Advances in Technology
McDonnell, D. J., Smith, D., & Forde, H. E. (2026) · Springer eBooks · doi:10.1007/978-3-032-24854-1_4
Ruiz, J., Buros‐Stein, A., Wheelock, A., Stewart, B., Bernique, A. S., Jost, E., Garvey, K. C., Astley, C. M., & Cobry, E. C. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156261486139
Holt, R. I. G., DeVries, J. H., Fischl, A. H., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, É., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06833-z · Cited by 1
Olsen, M. T., Spanakis, E. K., Thabit, H., Dhatariya, K., Mustafa, O. G., Avari, P., Lumb, A. N., Dungan, K. M., Philis‐Tsimikas, A., Kulasa, K. M., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06838-8 · Cited by 1
“Experts in inpatient diabetes care have advocated for CGM-based insulin titration protocols; however, consensus is lacking [19, 22, 23].”
Self-citationPresswala, L. S., Montaser, E., Isaacs, D. M., Shah, V. N., Vellanki, P., & Horton, W. B. (2026) · AACE Endocrinology and Diabetes · doi:10.1016/j.aed.2026.08.026
Improving Inpatient Continuous Glucose Monitoring Documentation Through Targeted Nursing Education
MATTEI, L. D., Kashat, M., CELIK, B., Shelden, D., & Brennan, M. (2026) · Endocrine Practice · doi:10.1016/j.eprac.2026.09.114
The Use of Diabetes Technology in the Inpatient Setting
Akcan, T., Faulds, E. R., Lal, R., Davis, G. M., Brown, S. A., Pasquel, F. J., & Hughes, M. S. (2026) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2026.08.016
Pedersen, C., Johansen, A., Philipsen, A., Nørgaard, K., Itenov, T. S., Eiberg, J., Jørgensen, L. N., Palm, H., Meyhoff, C. S., & Aasvang, E. K. (2026) · British Journal of Anaesthesia · doi:10.1016/j.bja.2026.08.014
Diabetes im Krankenhaus – Praxisempfehlung der DDG
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2026) · Diabetologie und Stoffwechsel · doi:10.1055/a-2884-3481
Ergin, B. D., Mattishent, K., Holder, D. L., Minihane, A. M., Kelly, B., Holt, R. I. G., Murphy, H. R., Dhatariya, K., & Hornberger, M. (2026) · medRxiv · doi:10.64898/2026.10.14.26365417
Idrees, T., Nalabolu, S., Oladejo, O., Elshimy, G., Orobio, C., & Umpierrez, G. E. (2026) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2026-006533 · Cited by 1
“73 74 Although these technologies are still evolving, they represent a paradigm shift from reactive glucose management toward continuous, data-driven and increasingly automated care.”
Self-citationRSSDI consensus statement on the use of diabetes technology in India
Kesavadev, J., Maheshwari, A., Gupta, S., Parikh, R. M., Viswanathan, V., Saboo, B., Joshi, S., Chawla, M. S., Gupta, A., Misra, A., et al. (2026) · International Journal of Diabetes in Developing Countries · doi:10.1007/s13410-026-01755-3
Metadata
- Authors
- Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., Bak, L., Buckingham, B., Cook, C. B., Freckmann, G., Heinemann, L., Hovorka, R., Mathioudakis, N., Newman, T., O’Neal, D. N., Rickert, M., Sacks, D. B., Seley, J. J., Wallia, A., Shang, T., Zhang, J. Y., Han, J., & Klonoff, D. C.
- Affiliations
- Emory University (US)
- University of California, San Francisco (US)
- University of Virginia (US)
- University of California San Diego Medical Center (US)
- Vanderbilt University Medical Center (US)
- University of Maryland, Baltimore (US)
- Children's Hospital Los Angeles (US)
- Brigham and Women's Hospital (US)
- NYU Langone Health (US)
- Yale New Haven Hospital (US)
- Stanford Medicine (US)
- Mayo Clinic in Arizona (US)
- Institut für Diabetes-Technologie (Germany) (DE)
- Science Consulting in Diabetes GmbH, Neuss, Germany
- University of Cambridge (GB)
- Johns Hopkins University (US)
- Neal, Gerber and Eisenberg LLP, Chicago, IL, USA
- University of Melbourne Department of Medicine, St. Vincent’s Hospital, Fitzroy, Victoria, Australia
- Oregon Health & Science University (US)
- National Institutes of Health (US)
- Weill Cornell Medicine (US)
- Northwestern University (US)
- Diabetes Technology Society (US)
- Mills Peninsula Health Services (US)
- Corresponding author
- Klonoff, David C.
- ORCID
- Galindo, Rodolfo J.
- Umpierrez, Guillermo E.
- Rushakoff, Robert J.
- Basu, Ananda
- Nichols, James H.
- Spanakis, Elias K.
- Espinoza, Juan
- Palermo, Nadine E.
- Buckingham, Bruce
- Cook, Curtiss B.
- Freckmann, Guido
- Heinemann, Lutz
- Hovorka, Roman
- Mathioudakis, Nestoras
- O’Neal, David N.
- Rickert, Michaela
- Sacks, David B.
- Seley, Jane Jeffrie
- Wallia, Amisha
- Shang, Trisha
- Zhang, Jennifer Y.
- Han, Julia
- Klonoff, David C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2020-09-28
- Volume
- 14
- Issue
- 6
- Pages
- 1035-1064
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC7645140
- OpenAlex
- W3089189812
- Cited by
- 170
- References
- 127
- Citations by year
- 2026: 28 · 2025: 38 · 2024: 27 · 2023: 27 · 2022: 25 · 2021: 23 · 2020: 2
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo
- Funders
- abbott diabetes care
- dexcom
- medtronic
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, artificial pancreas, hospitalized patients, diabetes management, hospital care, device accuracy, hospital policy, clinical guidelines, diabetes technology
- MeSH terms
- Adult, Blood Glucose, Child, Diabetes Mellitus, Female, Hospitalization, Hospitals, Humans, Insulin, Insulin Infusion Systems, Pregnancy, Blood Glucose Self-Monitoring, Consensus, Diabetes Complications, Drug Dosage Calculations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.