Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline
Open accessThe DOI matches its Crossref record; 128 of the 128 references it cites were found in a registry or an index.
Abstract
This article is the work product of the Continuous Glucose Monitor and Automated Insulin Dosing Systems in the Hospital Consensus Guideline Panel, which was organized by Diabetes Technology Society and met virtually on April 23, 2020. The guideline panel consisted of 24 international experts in the use of continuous glucose monitors (CGMs) and automated insulin dosing (AID) systems representing adult endocrinology, pediatric endocrinology, obstetrics and gynecology, advanced practice nursing, diabetes care and education, clinical chemistry, bioengineering, and product liability law. The panelists reviewed the medical literature pertaining to five topics: (1) continuation of home CGMs after hospitalization, (2) initiation of CGMs in the hospital, (3) continuation of AID systems in the hospital, (4) logistics and hands-on care of hospitalized patients using CGMs and AID systems, and (5) data management of CGMs and AID systems in the hospital. The panelists then developed three types of recommendations for each topic, including clinical practice (to use the technology optimally), research (to improve the safety and effectiveness of the technology), and hospital policies (to build an environment for facilitating use of these devices) for each of the five topics. The panelists voted on 78 proposed recommendations. Based on the panel vote, 77 recommendations were classified as either strong or mild. One recommendation failed to reach consensus. Additional research is needed on CGMs and AID systems in the hospital setting regarding device accuracy, practices for deployment, data management, and achievable outcomes. This guideline is intended to support these technologies for the management of hospitalized patients with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Studies have been published assessing the effectiveness of this approach, which may ultimately lead to the approved use of CGM for monitoring hospitalized individuals (277,286-295).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [277]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Similarly, data are emerging on the inpatient use of AID systems and their challenges (277,296,297).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [277]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Because up to 40% to 50% of persons admitted with stress-related hyperglycemia have confirmed DM at 1 year they should be closely monitored after discharge.1378,1379”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1379]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U.S. Department of Health and Human Services FDA Center for Drug Evaluation and Research, U.S. Department of Health and Human Services FDA Center for Biologics Evaluation and Research, & U.S. Department of Health and Human Services FDA Center for Devices and Radiological Health (2006) · Health and Quality of Life Outcomes · doi:10.1186/1477-7525-4-79 · Cited by 2,856
Work system design for patient safety: the SEIPS model
Carayon, P., Schoofs Hundt, A., Karsh, B.-T., Gurses, A. P., Alvarado, C. J., Smith, M., & Flatley Brennan, P. (2006) · Quality in Health Care · doi:10.1136/qshc.2005.015842 · Cited by 1,795
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Intravascular Complications of Central Venous Catheterization by Insertion Site
Parienti, J.-J., Mongardon, N., Mégarbane, B., Mira, J.-P., Kalfon, P., Gros, A., Marqué, S., Thuong, M., Pottier, V., Ramakers, M., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500964 · Cited by 769
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Outcomes in Patients With Hyperglycemia Affected by COVID-19: Can We Do More on Glycemic Control?
Sardu, C., D’Onofrio, N., Balestrieri, M. L., Barbieri, M., Rizzo, M. R., Messina, V., Maggi, P., Coppola, N., Paolisso, G., & Marfella, R. (2020) · Diabetes Care · doi:10.2337/dc20-0723 · Cited by 424
Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital
Umpierrez, G. E., & Klonoff, D. C. (2018) · Diabetes Care · doi:10.2337/dci18-0002 · Cited by 251
Self-citationFundamentals of Clinical Data Science
(2019) · Springer eBooks · doi:10.1007/978-3-319-99713-1 · Cited by 235
Closed-loop insulin delivery for glycemic control in noncritical care
Bally, L., Thabit, H., Hartnell, S., Andereggen, E., Ruan, Y., Wilinska, M. E., Evans, M. L., Wertli, M. M., Coll, A. P., Stettler, C., et al. (2018) · New England Journal of Medicine · doi:10.1056/nejmoa1805233 · Cited by 232
Self-citationReal-Time Continuous Glucose Monitoring in Critically Ill Patients
Holzinger, U., Warszawska, J., Kitzberger, R., Wewalka, M., Miehsler, W., Herkner, H., & Madl, C. (2010) · Diabetes Care · doi:10.2337/dc09-1352 · Cited by 212
Research works printed but not linked: 3
- 49. Galindo RJ, Umpierrez GE. Management of diabetes and/or hyperglycemia in non-critical care hospital settings. In: Matfin G (ed.) Endocrine and Metabolic Medical Emergencies . Hoboken, BJ: John Wiley & Sons, Ltd; 2018:491-505.
- 148. Revision of the 'guideline of the German medical association on quality assurance in medical laboratory examinations - Rili-BAEK' (unauthorized translation). J Lab Med . 2015;39(1):26-69.
- 149. United States Supreme Court. Official Reports of the Supreme Court . Vol 531 Part 2. (Wagner FD, ed.). Supreme Court; 2001.
Cited by
Holt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetes Care · doi:10.2337/dci21-0043 · Cited by 699
“Similarly, patients using diabetes devices should be allowed to use them in an inpatient setting or during outpatient procedures when proper supervision is available and the patient/ caregiver is capable of managing the device(s) (283).”
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Self-citationHolt, R. I. G., DeVries, J. H., Hess-Fischl, A., Hirsch, I. B., Kirkman, M. S., Klupa, T., Ludwig, B., Nørgaard, K., Pettus, J., Renard, E., et al. (2021) · Diabetologia · doi:10.1007/s00125-021-05568-3 · Cited by 378
“Similarly, patients using diabetes devices should be allowed to use them in an inpatient setting or during outpatient procedures when proper supervision is available and the patient/caregiver is capable of managing the device(s) [283].”
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
Self-citation7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
Self-citationGrunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
Self-citation16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s016 · Cited by 221
Self-citation16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s016 · Cited by 195
Self-citation16. Diabetes Care in the Hospital: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Galindo, R. J., Hilliard, M. E., Johnson, E. L., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s016 · Cited by 167
Self-citationDavis, G. M., Spanakis, E. K., Migdal, A. L., Singh, L. G., Albury, B., Urrutia, M. A., Zamudio-Coronado, K. W., Scott, W. H., Doerfler, R., Lizama, S., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2856 · Cited by 160
“These advances in CGM technology have increased the interest in using CGM in the hospital setting; however, until recently inpatient use of CGM has only been investigational, with limited data regarding its accuracy in hospitalized patients (2,3).”
BackgroundSelf-citationHonarmand, K., Sirimaturos, M., Hirshberg, E. L., Bircher, N. G., Agus, M. S. D., Carpenter, D. L., Downs, C. R., Farrington, E. A., Freire, A. X., Grow, A., et al. (2024) · Critical Care Medicine · doi:10.1097/ccm.0000000000006174 · Cited by 202
“Guidance for hospital and ICU CGM use has been published (88, 132–134).”
BackgroundSelf-citationSpanakis, E. K., Urrutia, A., Galindo, R. J., Vellanki, P., Migdal, A. L., Davis, G., Fayfman, M., Idrees, T., Pasquel, F. J., Coronado, W. Z., et al. (2022) · Diabetes Care · doi:10.2337/dc22-0716 · Cited by 153
Self-citationMcCall, A. L., Lieb, D. C., Gianchandani, R., MacMaster, H., Maynard, G. A., Murad, M. H., Seaquist, E., Wolfsdorf, J. I., Wright, R. F., & Wiercioch, W. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac596 · Cited by 123
Use of Continuous Glucose Monitors by People Without Diabetes: An Idea Whose Time Has Come?
Klonoff, D. C., Nguyen, K. T., Xu, N. Y., Gutierrez, A., Espinoza, J. C., & Vidmar, A. P. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221110830 · Cited by 93
“43 The authors of this article believe that patients with related metabolic diseases characterized by inadequate insulin production or activity, like prediabetes, 44 gestational diabetes, 45 obesity, 46 and metabolic syndrome 47 may also benefit from CGM use, but more research is required to…”
BackgroundSelf-citationFreckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86
“12-15 This scoping literature review therefore offers a comprehensive overview of the relevant elements of clinical CGM performance evaluations published between 2002 and 2022.”
BackgroundSelf-citationA Consensus Statement for Continuous Glucose Monitoring Metrics for Inpatient Clinical Trials
Spanakis, E. K., Cook, C. B., Kulasa, K. M., Aloi, J., Bally, L., Davis, G. M., Dungan, K. M., Galindo, R. J., Mendez, C. E., Pasquel, F. J., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231191104 · Cited by 93
“1,11,57 7-9 Among studies comparing the accuracy of newer CGMs in non-critically ill patients, the overall mean absolute relative difference (MARD) was reported from 9.4% to 15.6%, with a Clark Error Grid (CEG) analysis demonstrating > 90% to 97% of values within Zones A and B (safety zones).”
BackgroundMethodInfluentialSelf-citationShang, T., Zhang, J. Y., Thomas, A., Arnold, M. A., Vetter, B. N., Heinemann, L., & Klonoff, D. C. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211007212 · Cited by 71
Self-citationContinuous Glucose Monitoring in the Hospital
Perez‐Guzman, M. C., Shang, T., Zhang, J. Y., Jornsay, D. L., & Klonoff, D. C. (2021) · Endocrinology and Metabolism · doi:10.3803/enm.2021.201 · Cited by 77
“In September 2020, Diabetes Technology Society published the ‘Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline’ to address how and when to best use both subcutaneous CGMs and automated insulin delivery (AID) systems, as well as to promote clinical research utilizing…”
BackgroundSelf-citationInterferences with CGM systems: practical relevance?
Heinemann, L. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211065065 · Cited by 65
Self-citationRajan, N., Duggan, E. W., Abdelmalak, B., Butz, S. F., Rodriguez, L. V., Vann, M. A., & Joshi, G. P. (2024) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000006791 · Cited by 85
“85 However, CGMs are not reliable in determining BG or guiding treatment decisions in patients with skin infections near sensor site, significant edema or significant fluid shifts 85 or severe hypoglycemia (<40 mg/dL, 2.2 mmol/L), or hyperglycemia (>500 mg/ dL, 27.8 mmoL/L).”
InfluentialNursing in the Digital Age: Harnessing telemedicine for enhanced patient care
David-Olawade, A. C., Olawade, D. B., Ojo, I. O., Famujimi, M. E., Olawumi, T. T., & Esan, D. T. (2024) · Informatics and Health · doi:10.1016/j.infoh.2024.07.003 · Cited by 89
Shaw, J. L. V., Bannuru, R. R., Beach, L. A., ElSayed, N. A., Freckmann, G., Füzéry, A. K., Fung, A. W. S., Gilbert, J. D., Yun, H., Korpi-Steiner, N. L., et al. (2024) · Diabetes Care · doi:10.2337/dci24-0073 · Cited by 78
Self-citationAvari, P., Lumb, A. N., Flanagan, D., Rayman, G. A., Misra, S., Dhatariya, K., & Choudhary, P. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221137338 · Cited by 76
Continuous glucose monitoring in the hospital: an update in the era of COVID-19
Gothong, C., Singh, L. G., Satyarengga, M., & Spanakis, E. K. (2021) · Current Opinion in Endocrinology Diabetes and Obesity · doi:10.1097/med.0000000000000693 · Cited by 63
Self-citationAccuracy and Potential Interferences of Continuous Glucose Monitoring Sensors in the Hospital
Bellido, V., Freckman, G., Pérez, A., & Galindo, R. J. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.06.007 · Cited by 57
Self-citationChen, E., Prakash, S., Reddi, V. J., Kim, D. A., & Rajpurkar, P. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01115-0 · Cited by 84
Wearable biomolecular sensing nanotechnologies in chronic disease management
Tu, J., Flynn, C. D., Yeom, J., Wu, Z., Kelley, S. O., & Gao, W. F. (2025) · Nature Nanotechnology · doi:10.1038/s41565-025-02010-2 · Cited by 72
Roldan, V. D. T., Urtecho, M., Nayfeh, T., Firwana, M., Muthusamy, K., Hasan, B., Abd‐Rabu, R., Maraboto, A., Qoubaitary, A., Prokop, L. J., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac601 · Cited by 49
Yeh, T., Yeung, M., & Mendelsohn Curanaj, F. A. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01375-7 · Cited by 46
Espinoza, J., Xu, N. Y., Nguyen, K. T., & Klonoff, D. C. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211058148 · Cited by 46
Self-citationCGM in the Hospital: Is It Ready for Prime Time?
Buschur, E., Faulds, E. R., & Dungan, K. M. (2022) · Current Diabetes Reports · doi:10.1007/s11892-022-01484-x · Cited by 50
Closed-loop insulin delivery: update on the state of the field and emerging technologies
Ware, J., & Hovorka, R. (2022) · Expert Review of Medical Devices · doi:10.1080/17434440.2022.2142556 · Cited by 47
“critically ill patients or prolonged surgery) [124].”
Self-citationHagerf, B. V., Protuš, M., Németová, L., Mráz, M., Kieslichová, E., Uchytilová, E., Indrova, V., Lelito, J., Girman, P., Haluzík, M., et al. (2024) · Diabetes Care · doi:10.2337/dc23-1663 · Cited by 49
Self-citationBellido, V., Aguilera, E., Cardona‐Hernandez, R., Díaz-Soto, G., de Villar, N. G. P., César, M. J. P., & Ampudia‐Blasco, F. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221088601 · Cited by 47
Perioperative glycemic management in adults presenting for elective cardiac and non-cardiac surgery
Sreedharan, R., Khanna, S. K., & Shaw, A. (2023) · Perioperative Medicine · doi:10.1186/s13741-023-00302-6 · Cited by 70
“CGM sensors could be invasive (intravascular), minimally invasive (subcutaneous) or non-invasive (transdermal) (Galindo et al. 2020).”
BackgroundAvari, P., Lumb, A. N., Flanagan, D., Rayman, G. A., Misra, S., Choudhary, P., & Dhatariya, K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221137335 · Cited by 42
Coldron, B. C., COATES, V. E., Khamis, A., & MacRury, S. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211053652 · Cited by 38
Zelada, H., Perez‐Guzman, M. C., Cherñavvsky, D. R., & Galindo, R. J. (2023) · Endocrine Connections · doi:10.1530/ec-23-0180 · Cited by 37
“It cannot reliably detect asymptomatic or nocturnal hypoglycemia and other potentially dangerous scenarios in the hospital (11, 13).”
BackgroundMethodInfluentialSelf-citationConsensus Report on the Use of Continuous Glucose Monitoring in Chronic Kidney Disease and Diabetes
Rhee, C. M., Gianchandani, R. Y., Kerr, D. E., Philis‐Tsimikas, A., Kovesdy, C. P., Stanton, R. C., Drincic, A., Galindo, R. J., Kalantar‐Zadeh, K., Neumiller, J. J., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241292041 · Cited by 41
Self-citationChagas, G. C. L., Teixeira, L., Clemente, M. R. C., Chagas, R. C. L., Pestana, D. V. S., Sombra, L. R. S., Lima, B. B., Galindo, R. J., & Abreu, M. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2024.111986 · Cited by 45
Self-citationContinuous Glucose Monitoring in the Intensive Care Unit
ARROYO, L. I. G., Faulds, E. R., Perez‐Guzman, M. C., Davis, G. M., Dungan, K. M., & Pasquel, F. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231169522 · Cited by 36
Galindo, R. J., Dhatariya, K., Peralta, F. G., & Umpierrez, G. E. (2022) · Current Diabetes Reports · doi:10.1007/s11892-022-01464-1 · Cited by 36
Self-citationTian, T., Aaron, R. E., Yeung, A. M., Huang, J. K., Drincic, A., Seley, J. J., Wallia, A., Gilbert, G. H., Spanakis, E. K., Masharani, U. B., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231186575 · Cited by 34
“Meeting topics included (1) Nursing Issues, Protocols, Order Sets, and Staff Education for Using CGMs, (2) Implementing CGM Programs for Use in the Wards, (3) Quality Metrics and Financial Implications of CGMs in the Hospital, (4) CGMs in the Critical Care Setting, (5) Special Situations: Labor/Delivery and Hemodialys…”
BackgroundSelf-citationZhang, J. Y., Shang, T., Ahn, D. T., Chen, K. Y., Coté, G. L., Espinoza, J., Mendez, C. E., Spanakis, E. K., Thompson, B., Wallia, A., et al. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820978399 · Cited by 33
Self-citationGlycemic targets in critically ill adults: A mini-review
See, K. C. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i10.1719 · Cited by 28
Hybrid closed-loop insulin pump technology can be safely used in the inpatient setting
Pelkey, M. N., Boyle, M. E., Long, A., Castro, J. C., Cook, C. B., & Thompson, B. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2022.11.006 · Cited by 25
Self-citationInterferent effect of hydroxyurea on continuous glucose monitoring
Szmuilowicz, E. D., & Aleppo, G. (2021) · Diabetes Care · doi:10.2337/dc20-3114 · Cited by 23
“source ofmeasurement error for all CGM systems (1).”
BackgroundTechnology in the management of diabetes in hospitalised adults
Thabit, H., & Schofield, J. D. (2024) · Diabetologia · doi:10.1007/s00125-024-06206-4 · Cited by 34
“Based on the above and other published evidence, several professional societies have produced clinical guidance and recommendations for CGM use in hospital settings [30, 71, 72].”
BackgroundAvari, P., Choudhary, P., Lumb, A. N., Misra, S., Rayman, G. A., Flanagan, D., Dhatariya, K., & the Joint British Diabetes Societies for Inpatient Care (JBDS‐IP) group (2024) · Diabetic Medicine · doi:10.1111/dme.15452 · Cited by 34
Bellido, V., & Pérez, A. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10225341 · Cited by 31
“Similarly, persons using CGM or FGM as outpatients could continue to use their devices in hospital, providing protocols are in place, and there are staff trained in their management [88].”
BackgroundNursing Perspectives on the Use of Continuous Glucose Monitoring in the Intensive Care Unit
Faulds, E. R., Dungan, K. M., McNett, M., JONES, L. G., Poindexter, N., Exline, M. C., Pattison, J., & Pasquel, F. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231170616 · Cited by 28
Interruption of Continuous Glucose Monitoring: Frequency and Adverse Consequences
Markov, A. M., Krutilova, P., Cedeno, A., McGill, J. B., & McKee, A. M. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231156572 · Cited by 25
Idrees, T., Castro-Revoredo, I. A., Oh, H. D., Gavaller, M. D., Zabala, Z., Moreno, E., Moazzami, B., Galindo, R. J., Vellanki, P., Cabb, E., et al. (2024) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2024.01.031 · Cited by 22
Self-citationOprea, A. D., Kalra, S. K., Duggan, E. W., Russell, L., Urman, R. D., Abdelmalak, B., Patel, P., Pfeifer, K. J., Grant, P., Charitou, M. M., et al. (2024) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2024.111627 · Cited by 22
Self-citationAdvances in the management of hyperglycaemia and diabetes mellitus during hospitalization
Idrees, T., Castro-Revoredo, I., Dhatariya, K., Hernandez, L., & Umpierrez, G. E. (2025) · Nature Reviews Endocrinology · doi:10.1038/s41574-025-01157-1 · Cited by 25
“Surgery-related issues involve using diathermy for procedures, or surgical teams who are unfamiliar with the technology 108 .”
Self-citationOlsen, M. T., Liarakos, A. L., Wilmot, E. G., Dhatariya, K., Thabit, H., Sánchez-García, D., Nørgaard, K., Pedersen‐Bjergaard, U., Hansen, K. B., Vangoitsenhoven, R., et al. (2025) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgaf074 · Cited by 19
Continuous glucose monitoring (CGM) in a non-Icu hospital setting: The patient's journey
Irace, C., Coluzzi, S., Cianni, G. D., Forte, E., Landi, F., Rizzo, M. R., Sesti, G., Succurro, E., & Consoli, A. (2023) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2023.06.021 · Cited by 19
The Performance of Continuous Glucose Monitoring During the Intraoperative Period: A Scoping Review
Lim, H. A., Kim, M.-J., Kim, N. J., Huh, J., Jeong, J.-O., Hwang, W., & Choi, H. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13206169 · Cited by 21
“Furthermore, interference from surgical devices, such as diathermy and radiation equipment, may lead to malfunction or signal loss [33].”
BackgroundMedina, A. M. G., Henao, D. C., Yepes, C. A., Silva, J., González, J. A. G., Cortés, D., Robledo, S., Mejía, G., & Rondón, M. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.110897 · Cited by 14
Continuous Glucose Monitoring for Hyperglycemia in Critically Ill Patients
Franck, A. J., Hendrickson, A. L., Telford, E. D., Davids, B. L., Casanova, I. M., Rosen, A. N., Hadigal, S., & Ross, R. C. (2025) · CHEST Journal · doi:10.1016/j.chest.2025.02.006 · Cited by 16
Longo, R. R., & Joshi, R. (2022) · Diabetes Spectrum · doi:10.2337/dsi22-0009 · Cited by 20
Diabetesmanagement im Krankenhaus (Update 2023)
Mader, J. K., Brix, J. M., Aberer, F., Vonbank, A., Resl, M., Hochfellner, D. A., Ress, C., Pieber, T. R., Stechemesser, L., & Sourij, H. (2023) · Wiener klinische Wochenschrift · doi:10.1007/s00508-023-02177-5 · Cited by 15
“derartigen Systemen festgelegt werden [89].”
Olsen, M. T., Klarskov, C. K., Dungu, A. M., Hansen, K. B., Pedersen‐Bjergaard, U., & Kristensen, P. L. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231221803 · Cited by 19
Hughes, M. S., Pasquel, F. J., Davis, G. M., Lal, R., Buckingham, B. A., Boughton, C. K., Brown, S. A., & Bally, L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0343 · Cited by 14
“18,19 In addition, real-world data on hospital AID use are limited to a few reports, 28 – 30 constrained by a lack of integration with EHR systems, which often results in reliance on POC glucose data for analyses.”
Self-citationSweeney, A. T., Pena, S., Sandeep, J., Hernandez, B., Chen, Y., Breeze, J. L., Bulut, A., Feghali, K., Abdelrehim, M., Abdelazeem, M., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.03.001 · Cited by 15
“34 Fortmann et al 12 recently published the fi rst randomized controlled trial using real-time CGM versus standard hospital glucose management in a non-ICU hospital setting.”
Review Article – Diabetes Technology in the Hospital: An Update
Visser, M. M., Vangoitsenhoven, R., Gillard, P., & Mathieu, C. (2024) · Current Diabetes Reports · doi:10.1007/s11892-024-01545-3 · Cited by 17
“These criteria include the patient is cognitively intact, that there is adequate supervision by specialized diabetes teams, and that there is no non-adjunctive use of CGM in the presence of conditions that could interfere with sensor accuracy [11, 46, 50, 51].”
InfluentialMadhun, N. Z., Galindo, R. J., Donato, J., Hwang, P. R., Shabir, H. F., Fowler, M. J., Molitch-Hou, E., Bena, J. F., Umpierrez, G. E., & Lansang, M. C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0226 · Cited by 9
Self-citationOlsen, M. T., Pedersen‐Bjergaard, U., Hjejle, S., Rasmussen, L. M., Klarskov, C. K., Lindegaard, B., Andersen, J. A., Gottlieb, H., Lunding, S., Hansen, K. B., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251331628 · Cited by 11
“13,16,17 This absence may lead to clinical inertia, where health care providers hesitate to make timely insulin adjustments even when real-time CGM data are available.”
The Role of the Diabetes Care and Education Specialist in the Hospital Setting
The Association of Diabetes Care & Education Specialists (2022) · The Science of Diabetes Self-Management and Care · doi:10.1177/26350106221094332 · Cited by 10
Faulds, E. R., Hester, J. C., Badakhshi, Y., Miller, J. D., Basil, R. C., Chandra, S., Chang, A. S., Garcia, M., JONES, L. G., Pintor-Jimenez, K. A., et al. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251343108 · Cited by 11
“27 The observed mean glucose (below 180 mg/ dL) and TIR of over 70% in hospitals A and B during IV insulin therapy likely reflects the goals that can be achieved with current IV insulin protocols.”
Inoue, Y., Kusaka, Y., Shinozaki, K., Lee, I., & Sode, K. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211070614 · Cited by 8
Ullal, J., Spanbauer, C., Baran, J. D., Bais, R., Chiang, H.-H., Chao, J. H., Khakpour, D., Panfil, P., Pasquel, F. J., Gligorijevic, N., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251368933 · Cited by 8
Prince, N., Ramsay, T., Shorr, R., RABASA-LHORET, R. P. R., & Sun, C. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251412482 · Cited by 7
“1,8,9,12,16,17,20 There was a transient approval period from health authorities allowing CGM use for inpatients during the COVID-19 pandemic.”
Demidowich, A. P., Stanback, C., & Zilbermint, M. F. (2024) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15190 · Cited by 14
Diabetes Technology Meeting 2020
Shang, T., Zhang, J. Y., Bequette, B. W., Raymond, J. K., Coté, G. L., Sherr, J. L., Castle, J. R., Pickup, J. C., Pavlovic, Y., Espinoza, J., et al. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211016480 · Cited by 9
Self-citationJensch, H., Setford, S. J., Thomé, N., Srikanthamoorthy, G., Weingärtner, L., Grady, M., Holt, E., & Pfützner, A. (2025) · Sensors · doi:10.3390/s25071985 · Cited by 11
“In fact, a recent consensus panel [47] felt that it was premature to fully endorse the use of CGM throughout a hospital environment (and especially in critical care) without confirmatory blood glucose testing using point-of-care devices.”
Real-World Performance of Personal Continuous Glucose Monitors During Hospitalization
Dumitrascu, A. G., Perry, M. C., Chindris, A.-M., Chirilă, R. M., Boone, R. J., Blumenfeld, S. G., Hodge, D. O., White, L. J., Gnanapandithan, K., Cruz, D. A. D. L., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0639 · Cited by 8
“3,18 Although not a head-to-head study nor having a matched patient population, we observed differences between MARD for Libre (11.3”
InfluentialUsing digital tools to improve diabetes care in India with continuous glucose monitoring
Kesavadev, J., Saboo, B., Chawla, M. S., Unnikrishnan, A., Dunn, T. C., & TIWASKAR, M. H. (2025) · Therapeutic Advances in Endocrinology and Metabolism · doi:10.1177/20420188251372290 · Cited by 8
Wang, R., Kyi, M., Krishnamoorthi, B., Tjahyadi, J., Connell, A., Chiang, C. Y., Renouf, D., Barmanray, R., & Fourlanos, S. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0604 · Cited by 11
“12 The Medtronic Sentrino device is approved for in-hospital use in Europe but requires a wired physical connection for transmission of glucose data.”
Insulin Therapy for Hyperglycemia Management in Critically Ill Patients
Eastman, D. K., Butler, J., Dicken, S., & Bottenberg, M. M. (2021) · Journal of Diabetes Mellitus · doi:10.4236/jdm.2021.115025 · Cited by 6
Diabetes Technology Use in Special Populations: A Narrative Review of Psychosocial Factors
Hughes, M. S., Aleppo, G., Bally, L., Batista, A. F. M. B., Brown, S. A., Faulds, E. R., Gonder-Frederick, L. A., Isaacs, D. M., Kahkoska, A. R., Ortega, J., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241296853 · Cited by 6
“4,105,106 However, the use of personal devices in the inpatient setting presents challenges.”
Agarwal, S., Demidowich, A. P., Soliman, D., Umpierrez, G. E., & Galindo, R. J. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251364276 · Cited by 7
“43 Hospital policies could adapt to allow parturient women to continue pre-existing CGM use during the intrapartum period.”
Self-citationSupporting the Use of a Person’s Own Diabetes Technology in the Inpatient Setting
Pattison, J., Dungan, K. M., & Faulds, E. R. (2022) · Diabetes Spectrum · doi:10.2337/dsi22-0011 · Cited by 5
Type 1 Diabetes Overview and Perioperative Management
Nelson, G., & Sumpter, K. (2023) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2023.02.001 · Cited by 5
Holt, E., Nguyen, H., Bispham, J. A., Liu, J., CHAPMAN, K. S. M., & Grady, M. (2023) · Clinical Diabetes · doi:10.2337/cd23-0005 · Cited by 5
Unlocking Real-Time Data Access in Diabetes Management: Toward an Interoperability Model
Randine, P., Wolff, M. K., Pocs, M., Connell, I. R. O., Cafazzo, J. A., & Årsand, E. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251327602 · Cited by 7
“60 Our study, set in the Norwegian context, identified seven diabetes medical devices and nine regulated software solutions, with the Dexcom G6 CGM device being a notable exception in offering publicly accessible APIs (Table 3).”
Knopp, M. I., Leonard, R., Geers, W., Tellez, S., Vidonish, B., Muthuvel, G., Magella, B., Yayah Jones, N.-H., Espinoza, J., & Corathers, S. D. (2026) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251395034 · Cited by 4
Self-citationMüssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2025) · Diabetologie und Stoffwechsel · doi:10.1055/a-2592-9700 · Cited by 7
Magliozzo, M., Tumminia, A., Arpi, M. L., Deiana, E., Guglielmo, M., Giannone, G., Frasca, F., & Gullo, D. (2024) · Journal of Endocrinological Investigation · doi:10.1007/s40618-024-02472-6 · Cited by 5
“The isCGM is less expensive and easier to use and apply, making it a feasible alternative to CGM devices also in the hospital setting [15].”
Flint, K. L., O’Connor, M. Y., Sabean, A., Ashley, A. L., Zheng, H., Yan, J., Steiner, B. A., Anandakugan, N., CALVERLEY, M. M., Bartholomew, R. A., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0628 · Cited by 4
“17,18 However, few studies have investigated the associations between CGM metrics and other clinically-relevant hospital-related outcomes.”
Empfehlungen zur Diabetes-Behandlung mit automatischen Insulin-Dosierungssystemen
Berge, T. V. D., Biester, S., Biester, T., Buchmann, A.-K., Datz, N., Grosser, U., Kapitzke, K., Klusmeier, B., Remus, K., Reschke, F., et al. (2021) · Diabetologie und Stoffwechsel · doi:10.1055/a-1652-9011 · Cited by 5
Imputation Model for Glucose Values Above the Upper Detection Limit for Continuous Glucose Monitors
Olsen, M. T., Panagiotou, M., Strømmen, K. J., Klarskov, C. K., Kristensen, P. L., & Mougiakakou, S. G. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.0092 · Cited by 2
Sakjirapapong, C., Sirinvaravong, S., Preechasuk, L., & Thongtang, N. (2025) · Journal of Diabetes Research · doi:10.1155/jdr/7538573 · Cited by 3
“The 2020 CGMs and Automated Insulin Dosing Systems in the Hospital Consensus Guideline recommended prescribing CGMs to reduce the frequency of nurse contact for glucose testing and the PPE usage for patients with highly contagious infectious diseases who were in isolation [7].”
Advanced Hybrid Closed-Loop Systems in Perioperative Care: Safety During Anesthesia
Medina, A. M. G., Henao, D. C., Múñoz, Ó., Maira, G., Hurtado, D., Vargas, C., Rojas-Acosta, G., & Zhong-Lin, C. (2025) · Diabetes Technology & Therapeutics · doi:10.1177/15209156251376011 · Cited by 4
“15 AIDs can be used for procedures lasting up to 2 h if the positioning of the CGM and insulin infusion device is compatible with the procedure and if the devices are not exposed to electrocautery or fl uoroscopy.”
Volčanšek, Š., Janež, A., & Srpčič, M. (2026) · Diabetology · doi:10.3390/diabetology7010006 · Cited by 3
“…in established users or personal insulin pump—AID use in in-patient settings is supported across several diabetes guidelines, including those from the American Diabetes Association [9], the Joint British Diabetes Societies [92], the Diabetes Technology Society [93], and the Endocrine Society [6].”
Avari, P., O'Regan, A., Preechasuk, L., Oliver, N. S., & Agha-Jaffar, R. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0507 · Cited by 3
Müssig, K., Gallwitz, B., Haak, T., Kellerer, M., & Siegel, E. G. (2024) · Diabetologie und Stoffwechsel · doi:10.1055/a-2251-2772 · Cited by 3
“…im Krankenhaus sind Medikamente wie GC, die eine ausgeprägte Insulinresistenz mit konsekutiver Hyperglykä-mie verursachen können, Übelkeit und Erbrechen sowie eine pa-renterale oder enterale Ernährung über eine nasogastrale Sonde oder perkutane endoskopische Gastrostomie (PEG) [66].”
Gaddeti, V., Bodda, Y., Kamani, C., Pratap, T., & Sateesh, J. (2024) · Students Conference on Engineering and Systems · doi:10.1109/sces61914.2024.10652320 · Cited by 3
“The emphasis on further research highlights the need for ongoing efforts to optimize the use of these technologies in hospitals [13].”
Background
Metadata
- Authors
- Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., Bak, L., Buckingham, B., Cook, C. B., Freckmann, G., Heinemann, L., Hovorka, R., Mathioudakis, N., Newman, T., O’Neal, D. N., Rickert, M., Sacks, D. B., Seley, J. J., Wallia, A., Shang, T., Zhang, J. Y., Han, J., & Klonoff, D. C.
- Affiliations
- Emory University (US)
- University of California, San Francisco (US)
- University of Virginia (US)
- University of California San Diego Medical Center (US)
- Vanderbilt University Medical Center (US)
- University of Maryland, Baltimore (US)
- Children's Hospital Los Angeles (US)
- Brigham and Women's Hospital (US)
- NYU Langone Health (US)
- Yale New Haven Hospital (US)
- Stanford Medicine (US)
- Mayo Clinic in Arizona (US)
- Institut für Diabetes-Technologie (Germany) (DE)
- Science Consulting in Diabetes GmbH, Neuss, Germany
- University of Cambridge (GB)
- Johns Hopkins University (US)
- Neal, Gerber and Eisenberg LLP, Chicago, IL, USA
- University of Melbourne Department of Medicine, St. Vincent’s Hospital, Fitzroy, Victoria, Australia
- Oregon Health & Science University (US)
- National Institutes of Health (US)
- Weill Cornell Medicine (US)
- Northwestern University (US)
- Diabetes Technology Society (US)
- Mills Peninsula Health Services (US)
- Corresponding author
- Klonoff, David C.
- ORCID
- Galindo, Rodolfo J.
- Umpierrez, Guillermo E.
- Rushakoff, Robert J.
- Basu, Ananda
- Nichols, James H.
- Spanakis, Elias K.
- Espinoza, Juan
- Palermo, Nadine E.
- Buckingham, Bruce
- Cook, Curtiss B.
- Freckmann, Guido
- Heinemann, Lutz
- Hovorka, Roman
- Mathioudakis, Nestoras
- O’Neal, David N.
- Rickert, Michaela
- Sacks, David B.
- Seley, Jane Jeffrie
- Wallia, Amisha
- Shang, Trisha
- Zhang, Jennifer Y.
- Han, Julia
- Klonoff, David C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2020-09-28
- Volume
- 14
- Issue
- 6
- Pages
- 1035-1064
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC7645140
- OpenAlex
- W3089189812
- Cited by
- 170
- References
- 127
- Citations by year
- 2026: 28 · 2025: 38 · 2024: 27 · 2023: 27 · 2022: 25 · 2021: 23 · 2020: 2
- FWCI
- 14.52
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo
- Funders
- abbott diabetes care
- dexcom
- medtronic
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, artificial pancreas, hospitalized patients, diabetes management, hospital care, device accuracy, hospital policy, clinical guidelines, diabetes technology
- MeSH terms
- Adult, Blood Glucose, Child, Diabetes Mellitus, Female, Hospitalization, Hospitals, Humans, Insulin, Insulin Infusion Systems, Pregnancy, Blood Glucose Self-Monitoring, Consensus, Diabetes Complications, Drug Dosage Calculations
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.