CoChat

Performance of the CHARGE-AF risk model for incident atrial fibrillation in the EPIC Norfolk cohort

Pfister, Roman, Brägelmann, Johannes, Michels, Guido, Wareham, Nick J, Luben, Robert, Khaw, Kay-Tee · 2015 · European Journal of Preventive Cardiology
Cited by 65

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Identification of individuals at risk for developing atrial fibrillation (AF) will help to target screening and preventive interventions. We aimed to validate the CHARGE-AF model (including variables age, race, height, weight, blood pressure, smoking, antihypertensive medication, diabetes, myocardial infarction and heart failure) for prediction of five-year incident AF in a representative European population with a wide age range. METHODS AND RESULTS: The CHARGE-AF model was calculated in 24,020 participants of the population-based EPIC Norfolk study with 236 cases of hospitalization with diagnosis of AF within five years. The model showed good discrimination (c-statistic 0.81, 95% confidence interval (CI) 0.75-0.85), but weak calibration (Chi(2)-statistic 142) with an almost two-fold overestimation of AF incidence. A recalibration to characteristics of the European Prospective Investigation into Cancer and Nutrition (EPIC) Norfolk cohort improved calibration considerably (Chi(2)-statistic 13.3), with acceptable discrimination in participants both >65 and ≤65 years of age (c-statistics 0.70, 95% CI 0.61-0.77 and 0.83, 95% CI 0.74-0.88). The recalibrated model also showed good discrimination in participants free of cardiovascular disease (c-statistics 0.80, 95% CI 0.75-0.84). Categories of predicted risk (<2.5%, 2.5-5% or >5%) showed good concordance with observed five-year AF incidence of 0.62%, 3.49% and 8.74% (log rank test p < 0.001), respectively. CONCLUSION: A recalibration of the CHARGE-AF model is necessary for accurate predictions of five-year risk of AF in the EPIC Norfolk population. The recalibrated model showed good discrimination across a wide age range and in individuals free of cardiovascular disease, and hence is broadly applicable in primary care to identify people at risk for development of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2047487314544045

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 65

Metadata

Authors
Pfister, R., Brägelmann, J., Michels, G., Wareham, N. J., Luben, R., & Khaw, K.-T.
Venue
European Journal of Preventive Cardiology
Published
2014-07-24
Volume
22
Issue
7
Pages
932-939
ISSN
  • 2047-4873 (ISSN-L)
  • 2047-4881
OpenAlex
W2027218023
Cited by
65
References
8
FWCI
3.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of the CHARGE-AF risk model for incident atrial fibrillation in the EPIC Norfolk cohort. https://app.cochat.ai/papers/10.1177/2047487314544045
The paper
Pfister, R., Brägelmann, J., Michels, G., Wareham, N. J., Luben, R., & Khaw, K.-T. (2015). Performance of the CHARGE-AF risk model for incident atrial fibrillation in the EPIC Norfolk cohort. European Journal of Preventive Cardiology. https://doi.org/10.1177/2047487314544045

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.