Use of pedometers and accelerometers in clinical populations: validity and reliability issues
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background: Pedometers and accelerometers are often used in clinical research studies, and have the potential to provide valid and objective information on physical activity. Objectives: The purposes of this review are to introduce clinicians to various activity monitors that are commercially available, and to discuss their strengths and limitations. Scientific articles over the past 20 years were reviewed, and the most common types of physical activity monitors were identified. Emphasis was placed on devices with established validity and reliability, which were acceptable to participants and did not interfere with their activities. Ease-of-use from the investigator's standpoint was also considered. Major findings: A number of activity monitors were identified, including four pedometers (Yamax SW digiwalker, New Lifestyles NL-2000, Omron HJ-720 ITC, and StepWatch), three accelerometer-based activity monitors (ActiGraph, Actical, and RT3), and a multisensor device (Sensewear Armband). Validity and reliability of these devices is discussed. Conclusions: Pedometers and accelerometers are useful for tracking ambulatory physical activity in clinical populations, and those that display steps and/or calories are useful in motivating patients to increase their activity levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of two objective measures of physical activity for children
Evenson, K. R., Catellier, D. J., Gill, K., Ondrak, K. S., & McMurray, R. G. (2008) · Journal of Sports Sciences · doi:10.1080/02640410802334196 · Cited by 2,677
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
Self-citationComparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Self-citationFoster, R. C., Lanningham-Foster, L. M., Manohar, C., McCrady, S. K., Nysse, L. J., Kaufman, K. R., Padgett, D. J., & Levine, J. A. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2005.07.006 · Cited by 187
Comparison of PAEE from Combined and Separate Heart Rate and Movement Models in Children
Corder, K., Brage, S., Wareham, N. J., & Ekelund, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000176466.78408.cc · Cited by 170
Mudge, S., Stott, N. S., & Walt, S. E. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.039 · Cited by 105
Cited by
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
A step-defined sedentary lifestyle index: <5000 steps/day
Tudor-Locke, C., Craig, C. L., Thyfault, J. P., & Spence, J. C. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0235 · Cited by 384
Wang, J. B., Cadmus-Bertram, L. A., Natarajan, L., White, M. M., Madanat, H., Nichols, J. F., Ayala, G. X., & Pierce, J. P. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0176 · Cited by 308
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
“Bassett and John (5) highlighted the monitors_ convenient display and utility as key features for clinical populations.”
BackgroundNormative Steps/Day Values for Older Adults: NHANES 2005-2006
Tudor-Locke, C., Schuna, J. M., Barreira, T. V., Mire, E. F., Broyles, S. T., Katzmarzyk, P. T., & Johnson, W. D. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt116 · Cited by 110
Metadata
- Authors
- Bassett, D. R., & John, D.
- Venue
- Physical Therapy Reviews
- Publisher
- Informa UK Limited
- Published
- 2010-06
- Volume
- 15
- Issue
- 3
- Pages
- 135-142
- ISSN
- 1083-3196 (ISSN-L)
- 1743-288X
- OpenAlex
- W2023102612
- Cited by
- 138
- References
- 11
- FWCI
- 4.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of pedometers and accelerometers in clinical populations: validity and reliability issues. https://app.cochat.ai/papers/10.1179/1743288x10y.0000000004
- The paper
- Bassett, D. R., & John, D. (2010). Use of pedometers and accelerometers in clinical populations: validity and reliability issues. Physical Therapy Reviews. https://doi.org/10.1179/1743288x10y.0000000004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.