Detection of expiratory flow limitation in COPD using the forced oscillation technique
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Expiratory flow limitation (EFL) during tidal breathing is a major determinant of dynamic hyperinflation and exercise limitation in chronic obstructive pulmonary disease (COPD). Current methods of detecting this are either invasive or unsuited to following changes breath-by-breath. It was hypothesised that tidal flow limitation would substantially reduce the total respiratory system reactance (X rs) during expiration, and that this reduction could be used to reliably detect if EFL was present. To test this, 5‐Hz forced oscillations were applied at the mouth in seven healthy subjects and 15 COPD patients (mean±sd forced expiratory volume in one second was 36.8±11.5 % predicted) during quiet breathing. COPD breaths were analysed (n=206) and classified as flow-limited if flow decreased as alveolar pressure increased, indeterminate if flow decreased at constant alveolar pressure, or nonflow-limited. Of these, 85 breaths were flow-limited, 80 were not and 41 were indeterminate. Among other indices, mean inspiratory minus mean expiratory X rs(Δ Xrs) and minimum expiratory X rs(X exp,min) identified flow-limited breaths with 100% specificity and sensitivity using a threshold between 2.53–3.12 cmH 2 O·s·L−1(Δ Xrs) and −7.38– −6.76 cmH 2 O·s·L−1(X exp,min) representing 6.0% and 3.9% of the total range of values respectively. No flow-limited breaths were seen in the normal subjects by either method. Within-breath respiratory system reactance provides an accurate, reliable and noninvasive technique to detect expiratory flow limitation in patients with chronic obstructive pulmonary disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
PAUWELS, R. A., BUIST, A. S., CALVERLEY, P. M. A., JENKINS, C. R., & HURD, S. S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2101039 · Cited by 6,587
Self-citationLung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
(1993) · PubMed · Cited by 3,827
Dynamic Hyperinflation and Exercise Intolerance in Chronic Obstructive Pulmonary Disease
O'DONNELL, D. E., REVILL, S. M., & WEBB, K. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.5.2012122 · Cited by 1,076
A simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Physical Properties of Human Lungs Measured During Spontaneous Respiration
Mead, J., & Whittenberger, J. L. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.5.12.779 · Cited by 729
Wave-speed limitation on expiratory flow-a unifying concept
Dawson, S. V., & Elliott, E. A. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.43.3.498 · Cited by 395
MARIN, J. M., CARRIZO, S. J., GASCON, M., SANCHEZ, A., GALLEGO, B., & CELLI, B. R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2003172 · Cited by 388
Relationship Between Maximum Expiratory Flow and Degree of Lung Inflation
Hyatt, R. E., Schilder, D. P., & Fry, D. L. (1958) · Journal of Applied Physiology · doi:10.1152/jappl.1958.13.3.331 · Cited by 333
Frequency dependence of flow resistance in patients with obstructive lung disease
Grimby, G., Takishima, T., Graham, W., Macklem, P. T., & Mead, J. (1968) · Journal of Clinical Investigation · doi:10.1172/jci105837 · Cited by 323
Self-citationEltayara, L., Becklake, M. R., Volta, C. A., & Milic-Emili, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970362 · Cited by 277
A simple method to detect expiratory flow limitation during spontaneous breathing
Koulouris, N., Valta, P., Lavoie, A., Corbeil, C., Chasse, M., Braidy, J., & Milic-Emili, J. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08020306 · Cited by 251
Oscillation Mechanics of the Respiratory System
Peslin, R., & Fredberg, J. J. (1986) · Comprehensive Physiology · doi:10.1002/cphy.cp030311 · Cited by 181
Hyatt, R. E. (1961) · PubMed · doi:10.1164/arrd.1961.83.5.676 · Cited by 148
Ventilatory mechanics and expiratory flow limitation during exercise in normal subjects
Olafsson, S., & Hyatt, R. E. (1969) · Journal of Clinical Investigation · doi:10.1172/jci106015 · Cited by 136
Boni, E. (2002) · Thorax · doi:10.1136/thorax.57.6.528 · Cited by 105
Kaczka, D. W., Ingenito, E. P., & Lutchen, K. R. (1999) · Annals of Biomedical Engineering · doi:10.1114/1.146 · Cited by 85
Detection of Expiratory Flow Limitation by Manual Compression of the Abdominal Wall
Ninane, V., Leduc, D., Kafi, S. A., NASSER, M., Houa, M., & SERGYSELS, R. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004150 · Cited by 63
Cited by
Physiology of obesity and effects on lung function
Salome, C. M., King, G. G., & Berend, N. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00694.2009 · Cited by 831
Technical standards for respiratory oscillometry
King, G. G., Bates, J., Berger, K. I., Calverley, P., de Melo, P. L., Dellacà, R. L., Farré, R., Hall, G. L., Ioan, I., Irvin, C. G., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00753-2019 · Cited by 756
Self-citationLong-term air pollution exposure and living close to busy roads are associated with COPD in women
Schikowski, T., Sugiri, D., Ranft, U., Gehring, U., Heinrich, J., Wichmann, H.-E., & Krämer, U. (2005) · Respiratory Research · doi:10.1186/1465-9921-6-152 · Cited by 419
An Official American Thoracic Society Workshop Report: Obesity and Asthma
Dixon, A. E., Holguin, F., Sood, A., Salome, C. M., Pratley, R. E., Beuther, D. A., Celedón, J. C., & Shore, S. A. (2010) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200903-013st · Cited by 348
Hogg, J. C., Paré, P. D., & Hackett, T.-L. (2017) · Physiological Reviews · doi:10.1152/physrev.00025.2015 · Cited by 332
Metadata
- Authors
- Dellacà, R. L., Santus, P., Aliverti, A., Stevenson, N., Centanni, S., Macklem, P. T., Pedotti, A., & Calverley, P. M. A.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 232-240
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2160808191
- Cited by
- 351
- References
- 20
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.