A simultaneous single breath measurement of pulmonary diffusing capacity with nitric oxide and carbon monoxide
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Pulmonary diffusing capacity (DL) for carbon monoxide (CO) and nitric oxide (NO) were simultaneously measured in man using the single breath method, by adding 4O ppm of NO to the inspired gas and analysing the expirate for NO by a chemiluminescent method. The mean ratio of DLNO to DLCO in thirteen subjects was 4.3 (SD 0.3), mean DLNO = 49 mmol.min-1.kPa-1 (SD 10) and mean DLCO = 11 mmol.min-1.kPa-1 (SD 2). An increase in alveolar oxygen concentration from a mean of 18 to 68% in five subjects was associated with a 54% fall in DLCO but no change in DLNO. A reduction of lung volume from total lung capacity (TLC) (mean of 7 l) to a mean volume of 3.9 l in five subjects caused a fall in both DLNO (by 34%) and DLCO (by 8%). With 175 watts cycle exercise in three subjects the DLCO rose by 45% and DLNO by 25%. Since NO reacts much faster with haemoglobin than CO, DLNO should be influenced much less by reaction with haemoglobin, and perhaps represents a better index for the diffusing capacity of the alveolar-capillary membrane (Dm) than DLCO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nitric oxide release accounts for the biological activity of endothelium-derived relaxing factor
Palmer, R. M. J., Ferrige, A. G., & Moncada, S. (1987) · Nature · doi:10.1038/327524a0 · Cited by 10,704
The diffusion of gases through the lungs of man
Krogh, M. (1915) · The Journal of Physiology · doi:10.1113/jphysiol.1915.sp001710 · Cited by 432
Blood–Gas Equilibration in Lungs
Piiper, J., & Scheid, P. (1980) · Elsevier eBooks · doi:10.1016/b978-0-12-744501-4.50010-8 · Cited by 77
Cited by
The L-Arginine-Nitric Oxide Pathway
Epstein, F. H., Moncada, S., & Higgs, A. (1993) · New England Journal of Medicine · doi:10.1056/nejm199312303292706 · Cited by 6,678
Inhaled nitric oxide. A selective pulmonary vasodilator reversing hypoxic pulmonary vasoconstriction
Frostell, C., Fratacci, M. D., Wain, J. C., Jones, R., & Zapol, W. M. (1991) · Circulation · doi:10.1161/01.cir.83.6.2038 · Cited by 1,128
Inhaled nitric oxide as a cause of selective pulmonary vasodilatation in pulmonary hypertension
PEPKEZABA, J. (1991) · The Lancet · doi:10.1016/0140-6736(91)92033-x · Cited by 1,055
Standardization of the measurement of transfer factor (diffusing capacity)
Cotes, J. E., Chinn, D. J., Quanjer, P. H., Roca, J., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.041s1693 · Cited by 680
Impairment of Endothelium-Dependent Pulmonary-Artery Relaxation in Chronic Obstructive Lung Disease
Dinh-Xuan, A. T., Higenbottam, T. W., Clelland, C. A., Pepke-Zaba, J., Cremona, G., Butt, A. Y., Large, S. R., Wells, F. C., & Wallwork, J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105303242203 · Cited by 528
Self-citationA two-compartment model of pulmonary nitric oxide exchange dynamics
Tsoukias, N. M., & George, S. C. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.653 · Cited by 477
Kinsella, J. P., Neish, S. R., Ivy, D. D., Shaffer, E., & Abman, S. H. (1993) · The Journal of Pediatrics · doi:10.1016/s0022-3476(05)81551-3 · Cited by 332
Exhaled Nitric Oxide in Chronic Obstructive Pulmonary Disease
MAZIAK, W., LOUKIDES, S., CULPITT, S., SULLIVAN, P., KHARITONOV, S. A., & BARNES, P. J. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.3.97-05009 · Cited by 324
Hughes, J. M. B., & Pride, N. B. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201112-2160ci · Cited by 259
Modeling pulmonary nitric oxide exchange
George, S. C., Hogman, M., Permutt, S., & Silkoff, P. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00950.2003 · Cited by 245
“Reported ranges for DLNO in healthy adults at total lung capacity (alveolar volumes of 5–7 liters) are 1,580– 2,100 pl s 1 ppb 1 using several different techniques (4, 13, 33, 47, 52).”
MethodEndogenous Nitric Oxide in Single Exhalations and the Change during Exercise
Persson, M. G., Wiklund, N. P., & Gustafsson, L. E. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1210 · Cited by 209
Lung Structure and the Intrinsic Challenges of Gas Exchange
Hsia, C. C. W., Hyde, D. M., & Weibel, E. R. (2016) · Comprehensive Physiology · doi:10.1002/cphy.c150028 · Cited by 191
Extended Exhaled NO Measurement Differentiates between Alveolar and Bronchial Inflammation
LEHTIMÄKI, L., KANKAANRANTA, H., SAARELAINEN, S., HAHTOLA, P., JÄRVENPÄÄ, R., KOIVULA, T., TURJANMAA, V., & MOILANEN, E. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2010171 · Cited by 186
Zavorsky, G. S., Hsia, C. C. W., Hughes, J. M. B., Borland, C. D. R., Guénard, H., van der Lee, I., Steenbruggen, I., Naeije, R., Cao, J., & Dinh-Xuan, A. T. (2017) · European Respiratory Journal · doi:10.1183/13993003.00962-2016 · Cited by 163
Self-citation
Metadata
- Authors
- Borland, C., & Higenbottam, T.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1989-01-01
- Volume
- 2
- Issue
- 1
- Pages
- 56-63
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1907170779
- Cited by
- 222
- References
- 3
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.