Self-monitoring of glucose in type 2 diabetes mellitus:a Bayesian meta-analysis of direct and indirect comparisons
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the relative effectiveness of interventions with self-monitoring blood glucose and self-monitoring of urine glucose, versus interventions without self-monitoring, in terms of HbA(1c) reductions in type 2 diabetes mellitus. METHODS: Thirteen published full reports on randomised controlled trials investigating the effects of self-monitoring glucose were identified by a systematic search of Medline, Embase, the Cochrane Library (1966-Nov 2005) and previous reviews. Three types of studies were included: self-monitoring of blood glucose versus no self-monitoring, self-monitoring of blood glucose versus self-monitoring of urine glucose and self-monitoring of blood glucose with regular feedback versus monitoring without feedback. The internal validity of studies was assessed systematically by two reviewers, using 13 criteria of a validated list. Results from the three types of studies were analysed simultaneously with a Bayesian metaanalysis of direct and indirect comparisons. RESULTS: Adjusted for baseline HbA(1c) level and internal validity, interventions with self-monitoring of blood glucose showed a reduction in HbA(1c) of 0.40 percentage-points (%) (95% credible interval [CrI] 0.07 to 0.70%) in comparison to interventions without self-monitoring. Regular feedback more than doubled the HbA(1c) reduction. Self-monitoring of urine glucose showed comparable results to interventions without self-monitoring (0.02% decrease in HbA(1c); 95% CrI -0.62 to 0.70%). There is a 88% probability that interventions with self-monitoring blood glucose are more effective than interventions with urine glucose monitoring (relative reduction in HbA(1c) is 0.38%, 95% CrI -0.30 to 1.00%). CONCLUSION: The randomized clinical trials performed to date provided positive results on the effectiveness of interventions with self-monitoring of blood glucose in type 2 diabetes mellitus. Regular medical feedback of the monitored HbA(1c) levels is important. Furthermore, self-monitoring of blood glucose is likely to be more effective than self-monitoring of urine glucose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simultaneous comparison of multiple treatments: Combining direct and indirect evidence.
Caldwell, D. M., Ades, A. E., & Higgins, J. P. T. (2005) · BMJ · doi:10.1136/bmj.331.7521.897 · Cited by 1,600
Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
Meal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287 · cited 2×
“The study by Guerci et al.(13), a randomised study in general practice in France, is a good example.”
MethodMartin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Davidson, M. B., Castellanos, M., Kain, D., & Duran, P. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.12.006 · Cited by 178
Faas, A., Schellevis, F. G., & Eijk, J. T. M. V. (1997) · Diabetes Care · doi:10.2337/diacare.20.9.1482 · Cited by 139
Cited by
Evaluation of networks of randomized trials
Salanti, G., Higgins, J. P., Ades, A., & Ioannidis, J. P. (2008) · Statistical Methods in Medical Research · doi:10.1177/0962280207080643 · Cited by 1,078
(2007) · Endocrine Practice · doi:10.4158/ep.13.s1.1 · Cited by 699
Walsh, T., Worthington, H. V., Glenny, A.-M., Appelbe, P., Marinho, V. C., & Shi, X. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007868.pub2 · Cited by 514
Jansen, J. P., Crawford, B., Bergman, G., & Stam, W. (2008) · Value in Health · doi:10.1111/j.1524-4733.2008.00347.x · Cited by 385
Self-citationImproving health outcomes with better patient understanding and education
Adams, R. (2010) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s7500 · Cited by 381
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
“Nine reviews included RCT’s only (Allemann 2009; Clar 2010; Jansen 2006; Kleefstra 2009; McIntosh 2010; Poolsup 2008; Poolsup 2009; Sarol 2005; Towfigh 2008), one included cross-sectional, longitudinal and (non)randomised trials (McAndrew 2007) and two combined observational studies and RCT’s…”
BackgroundMethodInfluentialThe Evidence for Medical Nutrition Therapy for Type 1 and Type 2 Diabetes in Adults
Franz, M. J., Powers, M. A., Leontos, C., Holzmeister, L. A., Kulkarni, K., Monk, A., Wedel, N., & Gradwell, E. (2010) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2010.09.014 · Cited by 306
Vigersky, R. A., Fonda, S. J., Chellappa, M., Walker, M. S., & Ehrhardt, N. M. (2012) · Diabetes Care · doi:10.2337/dc11-1438 · Cited by 301
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
“(2001)70 reported the results of a prospective study of 3567 Italian outpatients with T2DM, among whom there were 2855 patients with data on SMBG: 17% tested more than once per day, 31% tested more than once per week, 14% tested less than once per week and 38% did not perform SMBG. Among those not using insulin, and a…”
Ceriello, A., & Colagiuri, S. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02565.x · Cited by 268
Uncertainty in Treatment Rankings: Reanalysis of Network Meta-analyses of Randomized Trials
Trinquart, L., Attiche, N., Bafeta, A., Porcher, R., & Ravaud, P. (2016) · Annals of Internal Medicine · doi:10.7326/m15-2521 · Cited by 202
System Accuracy Evaluation of 27 Blood Glucose Monitoring Systems According to DIN EN ISO 15197
Freckmann, G., Baumstark, A., Jendrike, N., Zschornack, E., Kocher, S., Tshiananga, J., Heister, F., & Haug, C. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0128 · Cited by 195
“(6) BG concentration was measured with BG meter 1 of BG monitoring system 2.”
Farmer, A. J., Perera, R., Ward, A., Heneghan, C., Oke, J., Barnett, A. H., Davidson, M. B., Guerci, B., Coates, V., Schwedes, U., et al. (2012) · BMJ · doi:10.1136/bmj.e486 · Cited by 156
Allemann, S., Houriet, C., Diem, P., & Stettler, C. (2009) · Current Medical Research and Opinion · doi:10.1185/03007990903364665 · Cited by 115
Evaluating novel agent effects in multiple-treatments meta-regression
Salanti, G., Dias, S., Welton, N. J., Ades, A. E., Golfinopoulos, V., Kyrgiou, M., Mauri, D., & Ioannidis, J. P. A. (2010) · Statistics in Medicine · doi:10.1002/sim.4001 · Cited by 111
Barnett, A. H., Krentz, A. J., Strojek, K., Sieradzki, J., Azizi, F., Embong, M., Imamoglu, S., Perušičová, J., Uličiansky, V., & Winkler, G. (2008) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2008.00894.x · Cited by 106
Value of Self-Monitoring Blood Glucose Pattern Analysis in Improving Diabetes Outcomes
Parkin, C. G., & Davidson, J. A. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300314 · Cited by 96
Consensus Report of the Coalition for Clinical Research—Self-Monitoring of Blood Glucose
Klonoff, D. C., Bergenstal, R., Blonde, L., Boren, S. A., Church, T. S., Gaffaney, J., Jovanovič, L., Kendall, D. M., Kollman, C., Kovatchev, B. P., et al. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200612 · Cited by 74
Berard, L. D., Siemens, R., & Woo, V. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2017.10.007 · Cited by 69
Machry, R. V., Rados, D. V., Gregório, G. R. D., & Rodrigues, T. C. (2018) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2018.05.037 · Cited by 55
Bonomo, K., De Salve, A., Fiora, E., Mularoni, E., Massucco, P., Poy, P., Pomero, A., Cavalot, F., Anfossi, G., & Trovati, M. (2010) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2009.10.021 · Cited by 53
“[15] J.”
BackgroundSchnell, O., Alawi, H., Battelino, T., Ceriello, A., Diem, P., Felton, A., Grzeszczak, W., Harno, K., Kempler, P., Satman, I., et al. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0028 · Cited by 47
Parsons, S. N., Luzio, S. D., Harvey, J. N., Bain, S. C., Cheung, W. Y., Watkins, A., & Owens, D. R. (2019) · Diabetic Medicine · doi:10.1111/dme.13899 · Cited by 39
Hypoglycemia: Minimizing its impact in type 2 diabetes
Moghissi, E., Ismail-Beigi, F., & Devine, R. C. (2013) · Endocrine Practice · doi:10.4158/ep13005.ra · Cited by 39
Polonsky, W., Fisher, L., Schikman, C., Hinnen, D., Parkin, C., Jelsovsky, Z., Amstutz, L., Schweitzer, M., & Wagner, R. (2010) · BMC Family Practice · doi:10.1186/1471-2296-11-37 · Cited by 30
“This RCT is based on a comprehensive, critical review of the six largest RCTs that included insulin-naÏve T2DM patients [12-14,16-18] and published summaries of the literature [19-22].”
MethodPolonsky, W. H., Jelsovsky, Z., Panzera, S., Parkin, C. G., & Wagner, R. S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0087 · Cited by 30
B. Davidson, M. (2010) · Reviews on Recent Clinical Trials · doi:10.2174/157488710792007248 · Cited by 15
“Jansen § [24] Wing [5], Fontbonne [6], Allen [7], Muchmore [9], Jaber [10], Miles [11], Schwedes [13], Guerci [14], Davidson [15], Estey [20], Kwon [23], Brown [26] SMBG vs.”
BackgroundDavidson, P. C., Bode, B. W., Steed, R. D., & Hebblewhite, H. R. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100608 · Cited by 14
Metadata
- Authors
- Jansen, J. P.
- Venue
- Current Medical Research and Opinion
- Publisher
- Informa Healthcare
- Published
- 2006-03
- Volume
- 22
- Issue
- 4
- Pages
- 671-681
- ISSN
- 0300-7995 (ISSN-L)
- 1473-4877
- OpenAlex
- W2135760063
- Cited by
- 118
- References
- 7
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.