A standard curve based method for relative real time PCR data processing
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Background: Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. Results: We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I) Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II) The optimal threshold is selected automatically from regression parameters of the standard curve. (III) Crossing points (CPs) are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV) The means and their variances are calculated for CPs in PCR replicas. (V) The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. Conclusion: A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that standard curve design remains a reliable and simple alternative to the PCR-efficiency based calculations in relative real time PCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860 · cited 2×
“Compared to the growing number of studies addressing PCR efficiency calculations [3,5,8-10] there is a shortage of publications discussing practical details of the standard curve method [11].”
BackgroundMethodA new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Vandesompele, J., De Preter, K., Pattyn, F., Poppe, B., Van Roy, N., De Paepe, A., & Speleman, F. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-research0034 · Cited by 20,038
Primer3 on the WWW for General Users and for Biologist Programmers
Rozen, S., & Skaletsky, H. (2003) · Bioinformatics Methods and Protocols · doi:10.1385/1-59259-192-2:365 · Cited by 15,013
Pfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,376
Mutation of the mouse klotho gene leads to a syndrome resembling ageing
Kuro-o, M., Matsumura, Y., Aizawa, H., Kawaguchi, H., Suga, T., Utsugi, T., Ohyama, Y., Kurabayashi, M., Kaname, T., Kume, E., et al. (1997) · Nature · doi:10.1038/36285 · Cited by 3,837
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N., & Kuyatt, C. E. (2018) · doi:10.6028/nist.tn.1297-1993 · Cited by 2,582
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Processing of gene expression data generated by quantitative real-time RT-PCR.
Muller, P. Y., Janovjak, H., Miserez, A. R., & Dobbie, Z. (2002) · PubMed · Cited by 1,394
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Mathematics of quantitative kinetic PCR and the application of standard curves
Rutledge, R. G. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng093 · Cited by 545
Liu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516
Standardized determination of real-time PCR efficiency from a single reaction set-up
Tichopad, A. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng122 · Cited by 455
Bustin, S. A. (2004) · Cited by 337
Rutledge, R. G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh177 · Cited by 209
Statistical modeling for selecting housekeeper genes
Szabo, A., Perou, C. M., Karaca, M., Perreard, L., Quackenbush, J. F., & Bernard, P. S. (2004) · Genome Biology · doi:10.1186/gb-2004-5-8-r59 · Cited by 186
Vitzthum, F., Geiger, G., Bisswanger, H., Brunner, H., & Bernhagen, J. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4298 · Cited by 160
Kinetic Outlier Detection (KOD) in real-time PCR
Bar, T. (2003) · Nucleic Acids Research · doi:10.1093/nar/gng106 · Cited by 102
Cited by
Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Levine, S., Nguyen, T., Taylor, N., Friscia, M. E., Budak, M. T., Rothenberg, P., Zhu, J., Sachdeva, R., Sonnad, S., Kaiser, L. R., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070447 · Cited by 1,577
Novel Markers to Delineate Murine M1 and M2 Macrophages
Jablonski, K. A., Amici, S. A., Webb, L. M., Ruiz-Rosado, J. D. D., Popovich, P. G., Partida-Sanchez, S., & Guerau-de-Arellano, M. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145342 · Cited by 978
Gutierrez, L., Mauriat, M., Guénin, S., Pelloux, J., Lefebvre, J., Louvet, R., Rusterucci, C., Moritz, T., Guerineau, F., Bellini, C., et al. (2008) · Plant Biotechnology Journal · doi:10.1111/j.1467-7652.2008.00346.x · Cited by 696
Svec, D., Tichopad, A., Novosadova, V., Pfaffl, M. W., & Kubista, M. (2015) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2015.01.005 · Cited by 601
Gutierrez, L., Bussell, J. D., Păcurar, D. I., Schwambach, J., Păcurar, M., & Bellini, C. (2009) · The Plant Cell · doi:10.1105/tpc.108.064758 · Cited by 574
Metadata
- Authors
- Larionov, A., Krause, A., & Miller, W.
- Venue
- BMC Bioinformatics
- Published
- 2005-03-21
- Volume
- 6
- Issue
- 1
- Pages
- 62-62
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1506057870
- Cited by
- 946
- References
- 19
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.