Statistical significance of quantitative PCR
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Background: PCR has the potential to detect and precisely quantify specific DNA sequences, but it is not yet often used as a fully quantitative method. A number of data collection and processing strategies have been described for the implementation of quantitative PCR. However, they can be experimentally cumbersome, their relative performances have not been evaluated systematically, and they often remain poorly validated statistically and/or experimentally. In this study, we evaluated the performance of known methods, and compared them with newly developed data processing strategies in terms of resolution, precision and robustness. Results: Our results indicate that simple methods that do not rely on the estimation of the efficiency of the PCR amplification may provide reproducible and sensitive data, but that they do not quantify DNA with precision. Other evaluated methods based on sigmoidal or exponential curve fitting were generally of both poor resolution and precision. A statistical analysis of the parameters that influence efficiency indicated that it depends mostly on the selected amplicon and to a lesser extent on the particular biological sample analyzed. Thus, we devised various strategies based on individual or averaged efficiency values, which were used to assess the regulated expression of several genes in response to a growth factor. Conclusion: Overall, qPCR data analysis methods differ significantly in their performance, and this analysis identifies methods that provide DNA quantification estimates of high precision, robustness and reliability. These methods allow reliable estimations of relative expression ratio of two-fold or higher, and our analysis provides an estimation of the number of biological samples that have to be analyzed to achieve a given precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Measurement of the efficiency of a PCR reaction. A: Estimation of the efficiency using the Serial dilution (SerDil) method. Five dilutions of a cDNA sample were amplified using the fibronectin (FN) amplicon. Each dilution was analyzed with five replicates PCR reactions and each data point represents one Ct value determined as in Figure 1B. Linear regression parameters and calculation of the efficiency value are shown in the inserted textbox. B: Screenshot of the LinReg PCR program analysis window, which allows the estimation of the efficiency value from each set of amplification curves [13]. Data correspond to one of the reactions performed from the undiluted sample used in part A. C: Comparison of the efficiency values obtained using the Serial dilution and LinReg methods for the FN amplicon. Efficiency values were determined from four independent cDNA samples using the Serial Dilution method as in part A, or the LinReg method as in part B. For each sample, efficiency value were either determined from one linear regression performed on 24 reactions altogether (Serdil) and error bars calculated from the standard deviation on the slope as determined from the linear regression method or the individual efficiency values determined from each of the same 24 PCR reactions (LinReg) were averaged, and error bars represent the standard deviation on the set of values.](https://figures.cochat.ai/paper-figures/ce9edacd1f9043e387a8a7c00833a620/statistical-significance-of-quantitative-pcr-figure-2.jpg)



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“The root cause of poor quality data is typically associated with inadequate dilution of residual protein and chemical contaminants that variably inhibit Taq polymerase and primer annealing.”
From Droplet Digital PCR versus qPCR for gene expression analysis with low abundant targets: from variable nonsense to publication quality data (2017) · cites this paper as [20]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“a systematic evaluation has revealed that qPCR data-analysis methods differ substantially in their performance (68 )”
From The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments (2009) · cites this paper as [68]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Mutation of the mouse klotho gene leads to a syndrome resembling ageing
Kuro-o, M., Matsumura, Y., Aizawa, H., Kawaguchi, H., Suga, T., Utsugi, T., Ohyama, Y., Kurabayashi, M., Kaname, T., Kume, E., et al. (1997) · Nature · doi:10.1038/36285 · Cited by 3,837
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709
Statistical analysis of real-time PCR data
Yuan, J. S., Reed, A., Chen, F., & Stewart, C. N. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-85 · Cited by 2,195
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Gene quantification using real-time quantitative PCR
Ginzinger, D. G. (2002) · Experimental Hematology · doi:10.1016/s0301-472x(02)00806-8 · Cited by 1,278
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Quantitative RT-PCR: Pitfalls and Potential
Freeman, W. M., Walker, S. J., & Vrana, K. E. (1999) · BioTechniques · doi:10.2144/99261rv01 · Cited by 1,147
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
Simultaneous Amplification and Detection of Specific DNA Sequences
Higuchi, R., Dollinger, G., Walsh, P. S., & Griffith, R. (1992) · Bio/Technology · doi:10.1038/nbt0492-413 · Cited by 1,130
Schmittgen, T. D., Zakrajsek, B. A., Mills, A. G., Gorn, V., Singer, M. J., & Reed, M. W. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4753 · Cited by 1,035
Quantification of low-copy transcripts by continuous SYBR Green I monitoring during amplification.
Morrison, T. B., Weis, J. J., & Wittwer, C. T. (1998) · PubMed · Cited by 958
Igarashi, A., Okochi, H., Bradham, D. M., & Grotendorst, G. R. (1993) · Molecular Biology of the Cell · doi:10.1091/mbc.4.6.637 · Cited by 706
Zhang, Y. (2007) · The American Statistician · doi:10.1198/tas.2007.s79 · Cited by 523
Liu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359
Rajeevan, M. S., Ranamukhaarachchi, D. G., Vernon, S. D., & Unger, E. R. (2001) · Methods · doi:10.1006/meth.2001.1266 · Cited by 324
Control genes in quantitative molecular biological techniques: the variability of invariance
Stürzenbaum, S. R., & Kille, P. (2001) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/s1096-4959(01)00440-7 · Cited by 278
Keski-Oja, J., Raghow, R., Sawdey, M., Loskutoff, D. J., Postlethwaite, A. E., Kang, A. H., & Moses, H. L. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)69042-8 · Cited by 241
Quantitative PCR: Theoretical Considerations with Practical Implications
Raeymaekers, L. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1542 · Cited by 226
Rutledge, R. G. (2004) · Nucleic Acids Research · doi:10.1093/nar/gnh177 · Cited by 209
Theoretical uncertainty of measurements using quantitative polymerase chain reaction
Peccoud, J., & Jacob, C. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79205-6 · Cited by 170 · cited 2×
“Initially, we first evaluated previously reported methods and concluded that an estimation of the PCR amplification efficiency is prerequisite to obtaining precise quantification, in agreement with other studies [6,25-28].”
Inhibition of real-time RT–PCR quantification due to tissue-specific contaminants
Tichopád, A., Didier, A., & Pfaffl, M. W. (2003) · Molecular and Cellular Probes · doi:10.1016/j.mcp.2003.09.001 · Cited by 147
Effect of Highly Fragmented DNA on PCR
Golenberg, E. M., Bickel, A., & Weihs, P. (1996) · Nucleic Acids Research · doi:10.1093/nar/24.24.5026 · Cited by 140
On the logistic law of growth and its empirical verifications in biology
Feller, W. (1940) · Acta Biotheoretica · doi:10.1007/bf01602862 · Cited by 134
Ståhlberg, A., Åman, P., Ridell, B., Mostad, P., & Kubista, M. (2003) · Clinical Chemistry · doi:10.1373/49.1.51 · Cited by 128 · cited 1×
“Others have observed that sample to sample variations may predominate, which may reflect differences in sample preparation methods and/or distinct biological systems [31].”
Marino, J. H., Cook, P., & Miller, K. S. (2003) · Journal of Immunological Methods · doi:10.1016/s0022-1759(03)00103-0 · Cited by 127
Comparison of mRNA gene expression by RT-PCR and DNA microarray
Etienne, W., Meyer, M. H., Peppers, J., & Meyer, R. A. (2004) · BioTechniques · doi:10.2144/04364st02 · Cited by 122
Effect of DNA damage on PCR amplification efficiency with the relative threshold cycle method
Sikorsky, J. A., Primerano, D. A., Fenger, T. W., & Denvir, J. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2004.08.168 · Cited by 118
Efficiency of DNA replication in the polymerase chain reaction
Stolovitzky, G., & Cecchi, G. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.23.12947 · Cited by 112 · cited 1×
“Quantitative PCR is used under the assumption that these stochastic processes are the same for all amplifications, which may be statistically correct for N0 values that are large enough so that sampling errors become negligible [7].”
High-Resolution Semi-Quantitative Real-Time PCR without the Use of a Standard Curve
Gentle, A., Anastasopoulos, F., & McBrien, N. A. (2001) · BioTechniques · doi:10.2144/01313st03 · Cited by 96
Tichopád, A., Džidić, A., & Pfaffl, M. W. (2002) · Biotechnology Letters · doi:10.1023/a:1021319421153 · Cited by 71
Evaluation of absolute quantitation by nonlinear regression in probe-based real-time PCR
Goll, R., Olsen, T., Cui, G., & Florholmen, J. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-107 · Cited by 57
Ailenberg, M., & Silverman, M. (2000) · BioTechniques · doi:10.2144/00295st03 · Cited by 46
Pankiewicz, R., Karlen, Y., Imhof, M. O., & Mermod, N. (2005) · The Journal of Gene Medicine · doi:10.1002/jgm.644 · Cited by 28
Self-citationStatistical Estimations of PCR Amplification Rates
Peccoud, J., & Jacob, C. (1998) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-4164-5_7 · Cited by 24
Research works printed but not linked: 2
- Livak KJ ABI Prism 7700 sequence detection system. User Bulletin 2. P E Applied Biosystems 1997
- Rosner B Fundamentals in biostatistics 2000 5th edit. Duxbury ed. 518 520
Cited by
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
“Accordingly, several authors reported that the mean of the individual PCR efficiencies gave less biased results than a standard curve-derived efficiency (10,11,26).”
Self-citationTaylor, S. C., Laperriere, G., & Germain, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-02217-x · Cited by 638
Direct Serum Assay for MicroRNA-21 Concentrations in Early and Advanced Breast Cancer
Asaga, S., Kuo, C., Nguyen, T., Terpenning, M., Giuliano, A. E., & Hoon, D. S. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.151845 · Cited by 451
Data exploration, quality control and testing in single-cell qPCR-based gene expression experiments
McDavid, A., Finak, G., Chattopadyay, P. K., Dominguez, M., Lamoreaux, L., Ma, S. S., Roederer, M., & Gottardo, R. (2013) · Bioinformatics · doi:10.1093/bioinformatics/bts714 · Cited by 395
“The fluo-resence is directly proportional to the starting concentration of mRNA (Higuchi et al. , 1992; Karlen et al. , 2007).”
Metadata
- Authors
- Karlen, Y., McNair, A., Perseguers, S., Mazza, C., & Mermod, N.
- Affiliations
- University of Lausanne (CH)
- Max Planck Institute of Quantum Optics (DE)
- University of Fribourg (CH)
- Corresponding author
- Mermod, Nicolas
- Venue
- BMC Bioinformatics
- Published
- 2007-04-20
- Volume
- 8
- Issue
- 1
- Pages
- 131-131
- ISSN
- 1471-2105 (ISSN-L)
- PMC
- PMC1868764
- OpenAlex
- W2073857965
- Cited by
- 373
- References
- 39
- Citations by year
- 2026: 11 · 2025: 9 · 2024: 15 · 2023: 19 · 2022: 16 · 2021: 24 · 2020: 16 · 2019: 12 · 2018: 13 · 2017: 20 · 2016: 20 · 2015: 21 · 2014: 26 · 2013: 30 · 2012: 24
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- BMC Bioinformatics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- reroDoc Digital Library (submittedVersion)
- IRIS (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- SERVAL (Université de Lausanne) (submittedVersion, other-oa)
- Funders
- National Science Foundation
- Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Keywords
- real-time PCR, qPCR data analysis, PCR efficiency, efficiency estimation, sigmoidal curve fitting, exponential fitting, relative gene expression, statistical power
- MeSH terms
- Base Sequence, Gene Expression Regulation, Polymerase Chain Reaction, Sequence Analysis, DNA
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.