Comparison of older and newer generations of ActiGraph accelerometers with the normal filter and the low frequency extension
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many studies used the older ActiGraph (7164) for physical activity measurement, but this model has been replaced with newer ones (e.g., GT3X+). The assumption that new generation models are more accurate has been questioned, especially for measuring lower intensity levels. The low-frequency extension (LFE) increases the low-intensity sensitivity of newer models, but its comparability with older models is unknown. This study compared step counts and physical activity collected with the 7164 and GT3X + using the Normal Filter and the LFE (GT3X+N and GT3X+LFE, respectively). FINDINGS: Twenty-five adults wore 2 accelerometer models simultaneously for 3 days and were instructed to engage in typical behaviors. Average daily step counts and minutes per day in nonwear, sedentary, light, moderate, and vigorous activity were calculated. Repeated measures ANOVAs with post-hoc pairwise comparisons were used to compare mean values. Means for the GT3X+N and 7164 were significantly different in 4 of the 6 categories (p<.05). The GT3X+N showed 2041 fewer steps per day and more sedentary, less light, and less moderate than the 7164 (+25.6, -31.2, -2.9 mins/day, respectively). The GT3X+LFE showed non-significant differences in 5 of 6 categories but recorded significantly more steps (+3597 steps/day; p<.001) than the 7164. CONCLUSION: Studies using the newer ActiGraphs should employ the LFE for greater sensitivity to lower intensity activity and more comparable activity results with studies using the older models. Newer generation ActiGraphs do not produce comparable step counts to the older generation devices with the Normal filter or the LFE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“Although the old models have been discontinued and replaced with new generation devices, many populationbased physical activity studies [4-6] used the 7164.”
BackgroundCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 2×
“Freedson [21]) may not be suitable for data collected with”
BackgroundMethodToo Much Sitting: The Population Health Science of Sedentary Behavior
Owen, N., Healy, G. N., Matthews, C. E., & Dunstan, D. W. (2010) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181e373a2 · Cited by 2,202 · cited 1×
“With a growing interest in sedentary behavior [13], this is an important concern.”
BackgroundValidation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804 · cited 1×
“cut points derived from studies using the newer models (with the Normal filter) [22-24] may not be appropriate”
MethodComparison of Accelerometer Cut Points for Predicting Activity Intensity in Youth
TROST, S. G., LOPRINZI, P. D., MOORE, R., & PFEIFFER, K. A. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318206476e · Cited by 1,360 · cited 1×
“cut points derived from studies using the newer models (with the Normal filter) [22-24] may not be appropriate”
MethodThe Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996 · cited 2×
“ActiGraph also introduced a new digital filtering algorithm (referred to as the Normal filter) for use with the new models that was designed to eliminate any acceleration noise outside of the normal human activity frequency bandwidth [2,3].”
BackgroundMethodUsing Accelerometers in Youth Physical Activity Studies: A Review of Methods
Cain, K. L., Sallis, J. F., Conway, T. L., Van Dyck, D., & Calhoon, L. (2013) · Journal of Physical Activity and Health · doi:10.1123/jpah.10.3.437 · Cited by 713 · cited 1×
“A review of 183 youth accelerometer studies from 2005–2010 revealed that the 7164 was used in 80% of studies reporting an ActiGraph model [7].”
MethodSelf-citationEkelund, U., Sardinha, L. B., Anderssen, S. A., Harro, M., Franks, P. W., Brage, S., Cooper, A. R., Andersen, L. B., Riddoch, C., & Froberg, K. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/80.3.584 · Cited by 428 · cited 1×
“Although the old models have been discontinued and replaced with new generation devices, many populationbased physical activity studies [4-6] used the 7164.”
BackgroundMattocks, C., Ness, A., Leary, S., Tilling, K., Blair, S. N., Shield, J., Deere, K., Saunders, J., Kirkby, J., Smith, G. D., et al. (2008) · Journal of Physical Activity and Health · doi:10.1123/jpah.5.s1.s98 · Cited by 395 · cited 1×
“Although the old models have been discontinued and replaced with new generation devices, many populationbased physical activity studies [4-6] used the 7164.”
BackgroundActiGraph and Actical Physical Activity Monitors: A Peek under the Hood
JOHN, D., & FREEDSON, P. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399f5e · Cited by 353
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229 · cited 2×
“error) compared with direct observation [8].”
ResultComparison of Four ActiGraph Accelerometers during Walking and Running
JOHN, D., TYO, B., & BASSETT, D. R. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181b3af49 · Cited by 183 · cited 3×
“Present results showing less moderate activity with the GT3X+N compared with the 7164 are not consistent with studies showing no significant differences between newer and older generation devices [10-12,16].”
BackgroundResultComparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177 · cited 3×
“Present results showing less moderate activity with the GT3X+N compared with the 7164 are not consistent with studies showing no significant differences between newer and older generation devices [10-12,16].”
BackgroundResultToo much sitting: the population health science of sedentary behavior
Dunstan, D. W., Healy, G. N., Sugiyama, T., & Owen, N. G. (2010) · touchREVIEWS in Endocrinology · Cited by 176
Evaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159 · cited 3×
“servation as the criterion measure in the lab and a validated pedometer in free-living settings [9].”
BackgroundResultCalibration and comparison of accelerometer cut points in preschool children
van Cauwenberghe, E., Labarque, V., Trost, S. G., de Bourdeaudhuij, I., & Cardon, G. (2011) · International Journal of Pediatric Obesity · doi:10.3109/17477166.2010.526223 · Cited by 152 · cited 1×
“cut points derived from studies using the newer models (with the Normal filter) [22-24] may not be appropriate”
MethodComparison of the ActiGraph 7164 and the ActiGraph GT1M during Self-Paced Locomotion
KOZEY, S. L., STAUDENMAYER, J. W., TROIANO, R. P., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c29e90 · Cited by 113 · cited 3×
“Present results showing less moderate activity with the GT3X+N compared with the 7164 are not consistent with studies showing no significant differences between newer and older generation devices [10-12,16].”
BackgroundResultMechanical and free living comparisons of four generations of the Actigraph activity monitor
Ried-Larsen, M., Brønd, J. C., Brage, S., Hansen, B. H., Grydeland, M., Andersen, L. B., & Møller, N. C. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-113 · Cited by 112
Effects of Filter Choice in GT3X Accelerometer Assessments of Free-Living Activity
Wanner, M., Martin, B. W., Meier, F., Probst-Hensch, N. M., & Kriemler, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31826c2cf1 · Cited by 51 · cited 3×
“However, Wanner and colleagues [15] found about 3 minutes per day more moderate-to -vigorous physical activity with the GT3X-LFE compared to the GT3X-N which is similar to the present findings.”
BackgroundResult
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Stepping [151, 192] and step counts [77, 119, 340, 405] were compared between 2 activity monitor devices (MPD ranged from -21.”
MethodGorman, E., Hanson, H. M., Yang, P. H., Khan, K. M., Liu-Ambrose, T., & Ashe, M. C. (2014) · European Review of Aging and Physical Activity · doi:10.1007/s11556-013-0132-x · Cited by 342
Accelerometer-based measures in physical activity surveillance: current practices and issues
Pedišić, Ž., & Bauman, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2013-093407 · Cited by 330
Correlates of Agreement between Accelerometry and Self-reported Physical Activity
CERIN, E., CAIN, K. L., OYEYEMI, A. L., OWEN, N., CONWAY, T. L., COCHRANE, T., VAN DYCK, D., SCHIPPERIJN, J., MITÁŠ, J., TOFTAGER, M., et al. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000870 · Cited by 180
“Comparisons between study sites using older versus newer accelerometer models might have been somewhat confounded by differences in accelerometer performance (4,31).”
BackgroundResultSelf-citation
Metadata
- Authors
- Cain, K. L., Conway, T. L., Adams, M. A., Husak, L. E., & Sallis, J. F.
- Venue
- International Journal of Behavioral Nutrition and Physical Activity
- Published
- 2013
- Volume
- 10
- Issue
- 1
- Pages
- 51
- ISSN
- 1479-5868 (ISSN-L)
- OpenAlex
- W2116883865
- Cited by
- 161
- References
- 19
- FWCI
- 6.73
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.