Continuous and simultaneous estimation of finger kinematics using inputs from an EMG-to-muscle activation model
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Surface electromyography (EMG) signals are often used in many robot and rehabilitation applications because these reflect motor intentions of users very well. However, very few studies have focused on the accurate and proportional control of the human hand using EMG signals. Many have focused on discrete gesture classification and some have encountered inherent problems such as electro-mechanical delays (EMD). Here, we present a new method for estimating simultaneous and multiple finger kinematics from multi-channel surface EMG signals. METHOD: In this study, surface EMG signals from the forearm and finger kinematic data were extracted from ten able-bodied subjects while they were tasked to do individual and simultaneous multiple finger flexion and extension movements in free space. Instead of using traditional time-domain features of EMG, an EMG-to-Muscle Activation model that parameterizes EMD was used and shown to give better estimation performance. A fast feed forward artificial neural network (ANN) and a nonparametric Gaussian Process (GP) regressor were both used and evaluated to estimate complex finger kinematics, with the latter rarely used in the other related literature. RESULTS: The estimation accuracies, in terms of mean correlation coefficient, were 0.85 ± 0.07, 0.78 ± 0.06 and 0.73 ± 0.04 for the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and the distal interphalangeal (DIP) finger joint DOFs, respectively. The mean root-mean-square error in each individual DOF ranged from 5 to 15%. We show that estimation improved using the proposed muscle activation inputs compared to other features, and that using GP regression gave better estimation results when using fewer training samples. CONCLUSION: The proposed method provides a viable means of capturing the general trend of finger movements and shows a good way of estimating finger joint kinematics using a muscle activation model that parameterizes EMD. The results from this study demonstrates a potential control strategy based on EMG that can be applied for simultaneous and continuous control of multiple DOF(s) devices such as robotic hand/finger prostheses or exoskeletons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Gaussian Processes for Machine Learning
Rasmussen, C. E., & Williams, C. K. I. (2005) · doi:10.7551/mitpress/3206.001.0001 · Cited by 11,705
Combinations of muscle synergies in the construction of a natural motor behavior
d'Avella, A., Saltiel, P., & Bizzi, E. (2003) · Nature Neuroscience · doi:10.1038/nn1010 · Cited by 1,344
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Buchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941 · cited 7×
“The raw EMG signals were first preprocessed into a form, that after further manipulation, can be used to estimate muscle activation [14].”
BackgroundMethodInfluentialHuang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2002) · Critical Reviews? in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v30.i456.80 · Cited by 606 · cited 2×
“Abbreviations EMG: Electromyography; EMD: Electro-mechanical delays; ANN: Artificial neural network; GP: Gaussian process; MCP: metacarpophalangeal; PIP: Proximal interphalangeal; DIP: Distal interphalangeal; DOF(s): Degree of freedom(s); MVC: Maximum voluntary contraction; TD: Time domain; MAV: Mean of the Absolute v…”
MethodControl of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Zecca, M., Micera, S., Carrozza, M. C., & Dario, P. (2017) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v45.i1-6.150 · Cited by 570
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450 · cited 1×
“using muscle synergy strategies extracted from a modified nonnegative matrix factorization algorithm to estimate the torque [8] and kinematics [9,10] of multiple DOFs produced at the wrists.”
MethodThe statistics of natural hand movements
Ingram, J. N., Körding, K. P., Howard, I. S., & Wolpert, D. M. (2008) · Experimental Brain Research · doi:10.1007/s00221-008-1355-3 · Cited by 330 · cited 2×
“This is consistent with earlier studies, where it was shown that despite the hand having more than 20 DOFs, the effective dimensionality is much lower [31].”
BackgroundResultChu, J.-U., Moon, I., Lee, Y.-J., Kim, S.-K., & Mun, M.-S. (2007) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2007.897262 · Cited by 299 · cited 2×
“In the past 30 years, discrete classification of hand gestures from EMG signals has been successful, consistently reaching decoding accuracies of above 95% and classifying more than 6 gestures, such as hand opening, closing and others [4,5].”
BackgroundResultMuceli, S., & Farina, D. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2178039 · Cited by 285 · cited 2×
“Participants Similar to contemporary studies that proposed new EMGbased control strategies for hand control [5,7,11-13], healthy, able-bodied subjects participated in the experiments, which can be an initial basis before testing with disabled or amputated subjects.”
BackgroundResultJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269 · cited 1×
“using muscle synergy strategies extracted from a modified nonnegative matrix factorization algorithm to estimate the torque [8] and kinematics [9,10] of multiple DOFs produced at the wrists.”
MethodIs Accurate Mapping of EMG Signals on Kinematics Needed for Precise Online Myoelectric Control?
Jiang, N., Vujaklija, I., Rehbaum, H., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2287383 · Cited by 218 · cited 2×
“When significant interaction was detected, focused ANOVA was conducted by fixing the levels of one of the interacting factors [10].”
Method26th Annual International Conference of the IEEE EMBS
Wang, L., Hammond, P., Johannessen, E. A., Tang, T. B., Astaras, A., Beaumont, S., Murray, A., Cooper, J. M., & Cumming, D. R. S. (2004) · Cited by 211
Jiang, N., Vest-Nielsen, J. L., Muceli, S., & Farina, D. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-42 · Cited by 181 · cited 1×
“However, classification approaches have been limited to use in controlled laboratory conditions and have not been used by any current commercial myoelectric prosthesis [6].”
BackgroundAnalysis of the synergies underlying complex hand manipulation
Todorov, E., & Ghahramani, Z. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404285 · Cited by 178 · cited 1×
“not only on the joint angular position data, but also on the joint angular velocities data because these are said to be more closely related to the motor command’s driving moment [30].”
BackgroundA real-time EMG-driven virtual arm
MANAL, K. T., Gonzalez, R. V., Lloyd, D. G., & Buchanan, T. S. (2002) · Computers in Biology and Medicine · doi:10.1016/s0010-4825(01)00024-5 · Cited by 157
Effect of arm position on the prediction of kinematics from EMG in amputees
Jiang, N., Muceli, S., Graimann, B., & Farina, D. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0979-4 · Cited by 126
Smith, R. J., Tenore, F. V., Huberdeau, D. M., Etienne‐Cummings, R., & Thakor, N. V. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649124 · Cited by 124 · cited 4×
“In the previous studies [11-13], a time delay between the onset of the EMG signal and the exerted movement was present and observed.”
MethodResultInfluentialDevelopment of an Implantable Myoelectric Sensor for Advanced Prosthesis Control
Merrill, D. R., Lockhart, J., Troyk, P. R., Weir, R. F., & Hankin, D. L. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01219.x · Cited by 117 · cited 1×
“Roughly about 30% to 50% of the available prosthesis is based on myoelectric control [1].”
BackgroundExtraction of the envelope from surface EMG signals
D’Alessio, T., & Conforto, S. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982276 · Cited by 66 · cited 1×
“In the paper [27], the authors presented the time constants of the filters used in analyzing surface EMG, which ranged from 10 to 150 ms.”
MethodLi, L., & Baum, B. S. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.04.004 · Cited by 65 · cited 3×
“Furthermore, compared to reported EMD values in the other studies, the range obtained is comparatively smaller compared to those taken from the lower limb during cycling tasks [18] or from the upper limb during objectcarrying tasks [3].”
BackgroundMethodResultControl of an optimal finger exoskeleton based on continuous joint angle estimation from EMG signals
Ngeo, J., Tamei, T., Shibata, T., Orlando, M. F., Behera, L., Saxena, A., & Dutta, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609506 · Cited by 55 · cited 1×
“Though not reported in this study, a practical real-time application using the proposed method with the neural network in controlling a custom-built one-finger exoskeleton has been done in our previous study [33].”
MethodSelf-citationHioki, M., & Kawasaki, H. (2012) · ISRN Rehabilitation · doi:10.5402/2012/604314 · Cited by 39 · cited 4×
“In the previous studies [11-13], a time delay between the onset of the EMG signal and the exerted movement was present and observed.”
MethodResultInfluentialTamei, T., & Shibata, T. (2011) · Advanced Robotics · doi:10.1163/016918611x558252 · Cited by 27 · cited 4×
“Furthermore, compared to reported EMD values in the other studies, the range obtained is comparatively smaller compared to those taken from the lower limb during cycling tasks [18] or from the upper limb during objectcarrying tasks [3].”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Neural Data-Driven Musculoskeletal Modeling for Personalized Neurorehabilitation Technologies
Sartori, M., Llyod, D. G., & Farina, D. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2538296 · Cited by 188
Atzori, M., & Müller, H. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00162 · Cited by 183
“In particular, recent work described average correlation coefficients of up to 0.9 for the estimation of single finger movements (Smith et al., 2008) and 0.8 for the estimation of simultaneous and complex movements (Ngeo et al., 2014).”
InfluentialVu, P. P., Irwin, Z. T., Bullard, A. J., Ambani, S. W., Sando, I. C., Urbanchek, M. G., Cederna, P. S., & Chestek, C. A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2772961 · Cited by 61
Use of probabilistic weights to enhance linear regression myoelectric control
Smith, L. H., Kuiken, T. A., & Hargrove, L. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066030 · Cited by 15
Metadata
- Authors
- Ngeo, J. G., Tamei, T., & Shibata, T.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014-08-14
- Volume
- 11
- Issue
- 1
- Pages
- 122-122
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2115647181
- Cited by
- 198
- References
- 26
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.