Autonomous exoskeleton reduces metabolic cost of human walking during load carriage
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Many soldiers are expected to carry heavy loads over extended distances, often resulting in physical and mental fatigue. In this study, the design and testing of an autonomous leg exoskeleton is presented. The aim of the device is to reduce the energetic cost of loaded walking. In addition, we present the Augmentation Factor, a general framework of exoskeletal performance that unifies our results with the varying abilities of previously developed exoskeletons. METHODS: We developed an autonomous battery powered exoskeleton that is capable of providing substantial levels of positive mechanical power to the ankle during the push-off region of stance phase. We measured the metabolic energy consumption of seven subjects walking on a level treadmill at 1.5 m/s, while wearing a 23 kg vest. RESULTS: During the push-off portion of the stance phase, the exoskeleton applied positive mechanical power with an average across the gait cycle equal to 23 ± 2 W (11.5 W per ankle). Use of the autonomous leg exoskeleton significantly reduced the metabolic cost of walking by 36 ± 12 W, which was an improvement of 8 ± 3% (p = 0.025) relative to the control condition of not wearing the exoskeleton. CONCLUSIONS: In the design of leg exoskeletons, the results of this study highlight the importance of minimizing exoskeletal power dissipation and added limb mass, while providing substantial positive power during the walking gait cycle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationBiomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170 · cited 1×
“Autonomous devices capable of providing biologically equivalent levels of joint mechanical power necessary for locomotion have been investigated, but these devices were cumbersome and heavy [7,15,16].”
BackgroundCompliant leg behaviour explains basic dynamics of walking and running
Geyer, H., Seyfarth, A., & Blickhan, R. (2006) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2006.3637 · Cited by 940
Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777
The Effects of Adding Mass to the Legs on the Energetics and Biomechanics of Walking
BROWNING, R. C., MODICA, J. R., KRAM, R., & GOSWAMI, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802b3562 · Cited by 603
Derivation of formulae used to calculate energy expenditure in man.
Brockway, J. M. (1987) · PubMed · Cited by 585
Muscular efficiency during steady-rate exercise: effects of speed and work rate
Gaesser, G. A., & Brooks, G. A. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.38.6.1132 · Cited by 575
Biomechanical Motor Patterns in Normal Walking
Winter, D. A. (1983) · Journal of Motor Behavior · doi:10.1080/00222895.1983.10735302 · Cited by 530
A Simple Exoskeleton That Assists Plantarflexion Can Reduce the Metabolic Cost of Human Walking
Malcolm, P., Derave, W., Galle, S., & De Clercq, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056137 · Cited by 428
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Self-citation
Cited by
Reducing the energy cost of human walking using an unpowered exoskeleton
Collins, S. H., Wiggin, M. B., & Sawicki, G. S. (2015) · Nature · doi:10.1038/nature14288 · Cited by 967
State of the Art and Future Directions for Lower Limb Robotic Exoskeletons
Young, A. J., & Ferris, D. P. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2521160 · Cited by 901
Human-in-the-loop optimization of hip assistance with a soft exosuit during walking
Ding, Y., Kim, M., Kuindersma, S., & Walsh, C. J. (2018) · Science Robotics · doi:10.1126/scirobotics.aar5438 · Cited by 612
Reducing the metabolic rate of walking and running with a versatile, portable exosuit
Kim, J., Lee, G., Heimgartner, R., Arumukhom Revi, D., Karavas, N., Nathanson, D., Galiana, I., Eckert-Erdheim, A., Murphy, P., Perry, D., et al. (2019) · Science · doi:10.1126/science.aav7536 · Cited by 482
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
“One mobile ankle exoskeleton (Mooney et al., 2014) has achieved a net metabolic reduction during walking at 1.”
BackgroundInfluentialThe exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Assistance magnitude versus metabolic cost reductions for a tethered multiarticular soft exosuit
Quinlivan, B. T., Lee, S., Malcolm, P., Rossi, D. M., Grimmer, M., Siviy, C., Karavas, N., Wagner, D., Asbeck, A., Galiana, I., et al. (2017) · Science Robotics · doi:10.1126/scirobotics.aah4416 · Cited by 370
Stronger, Smarter, Softer: Next-Generation Wearable Robots
Asbeck, A. T., De Rossi, S. M. M., Galiana, I., Ding, Y., & Walsh, C. J. (2014) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2014.2360283 · Cited by 368
Personalizing exoskeleton assistance while walking in the real world
Slade, P., Kochenderfer, M. J., Delp, S. L., & Collins, S. H. (2022) · Nature · doi:10.1038/s41586-022-05191-1 · Cited by 328
A biologically-inspired multi-joint soft exosuit that can reduce the energy cost of loaded walking
Panizzolo, F. A., Galiana, I., Asbeck, A. T., Siviy, C., Schmidt, K., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0150-9 · Cited by 291
Opportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Biomechanical and Physiological Evaluation of Multi-Joint Assistance With Soft Exosuits
Ding, Y., Galiana, I., Asbeck, A. T., De Rossi, S. M. M., Bae, J., Santos, T. R. T., de Araujo, V. L., Lee, S., Holt, K. G., & Walsh, C. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2523250 · Cited by 217
“83 W/kg, agreeing with previous findings [47], [48].”
ResultPowered exoskeletons for bipedal locomotion after spinal cord injury
Contreras-Vidal, J. L., A Bhagat, N., Brantley, J., Cruz-Garza, J. G., He, Y., Manley, Q., Nakagome, S., Nathan, K., Tan, S. H., Zhu, F., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031001 · Cited by 216
How adaptation, training, and customization contribute to benefits from exoskeleton assistance
Poggensee, K. L., & Collins, S. H. (2021) · Science Robotics · doi:10.1126/scirobotics.abf1078 · Cited by 214
Artificial intelligence meets medical robotics
Yip, M., Salcudean, S., Goldberg, K., Althoefer, K., Menciassi, A., Opfermann, J. D., Krieger, A., Swaminathan, K., Walsh, C. J., Huang, H. (., et al. (2023) · Science · doi:10.1126/science.adj3312 · Cited by 207
Simulating ideal assistive devices to reduce the metabolic cost of walking with heavy loads
Dembia, C. L., Silder, A., Uchida, T. K., Hicks, J. L., & Delp, S. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0180320 · Cited by 170
Real-Time Neural Network-Based Gait Phase Estimation Using a Robotic Hip Exoskeleton
Kang, I., Kunapuli, P., & Young, A. J. (2020) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2961749 · Cited by 168
“The advantage of using powered exoskeletons comes from their ability to implement different controllers to provide assistance during locomotion [6]–[13].”
BackgroundLee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Physiological and kinematic effects of a soft exosuit on arm movements
Xiloyannis, M., Chiaradia, D., Frisoli, A., & Masia, L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0495-y · Cited by 161
Task-agnostic exoskeleton control via biological joint moment estimation
Molinaro, D. D., Scherpereel, K. L., Schonhaut, E. B., Evangelopoulos, G., Shepherd, M. K., & Young, A. J. (2024) · Nature · doi:10.1038/s41586-024-08157-7 · Cited by 107
Kim, J., Quinlivan, B. T., Deprey, L.-A., Arumukhom Revi, D., Eckert-Erdheim, A., Murphy, P., Orzel, D., & Walsh, C. J. (2022) · Scientific Reports · doi:10.1038/s41598-022-14784-9 · Cited by 91
Transferable multi-modal fusion in knee angles and gait phases for their continuous prediction
Guo, Z., Zheng, H., Wu, H., Zhang, J., Zhou, G., & Long, J. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/accd22 · Cited by 18
Metadata
- Authors
- Mooney, L. M., Rouse, E. J., & Herr, H. M.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2014-05-09
- Volume
- 11
- Issue
- 1
- Pages
- 80-80
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2100792856
- Cited by
- 461
- References
- 34
- FWCI
- 13.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.