A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The goal of this study was to test the mechanical performance of a prototype knee-ankle-foot orthosis (KAFO) powered by artificial pneumatic muscles during human walking. We had previously built a powered ankle-foot orthosis (AFO) and used it effectively in studies on human motor adaptation, locomotion energetics, and gait rehabilitation. Extending the previous AFO to a KAFO presented additional challenges related to the force-length properties of the artificial pneumatic muscles and the presence of multiple antagonistic artificial pneumatic muscle pairs. METHODS: Three healthy males were fitted with custom KAFOs equipped with artificial pneumatic muscles to power ankle plantar flexion/dorsiflexion and knee extension/flexion. Subjects walked over ground at 1.25 m/s under four conditions without extensive practice: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under direct proportional myoelectric control, and 4) wearing the orthosis activated under proportional myoelectric control with flexor inhibition produced by leg extensor muscle activation. We collected joint kinematics, ground reaction forces, electromyography, and orthosis kinetics. RESULTS: The KAFO produced approximately 22%-33% of the peak knee flexor moment, approximately 15%-33% of the peak extensor moment, approximately 42%-46% of the peak plantar flexor moment, and approximately 83%-129% of the peak dorsiflexor moment during normal walking. With flexor inhibition produced by leg extensor muscle activation, ankle (Pearson r-value = 0.74 +/- 0.04) and knee ( r = 0.95 +/- 0.04) joint kinematic profiles were more similar to the without orthosis condition compared to when there was no flexor inhibition (r = 0.49 +/- 0.13 for ankle, p = 0.05, and r = 0.90 +/- 0.03 for knee, p = 0.17). CONCLUSION: The proportional myoelectric control with flexor inhibition allowed for a more normal gait than direct proportional myoelectric control. The current orthosis design provided knee torques smaller than the ankle torques due to the trade-off in torque and range of motion that occurs with artificial pneumatic muscles. Future KAFO designs could incorporate cams, gears, or different actuators to transmit greater torque to the knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Neptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132
Neuromechanics of Human Movement
Enoka, R. M. (2015) · Human Kinetics eBooks · doi:10.5040/9781492595632 · Cited by 703
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Eng, J. J., & Winter, D. A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00124-m · Cited by 481
Patton, J. L., Stoykov, M. E., Kovic, M., & Mussa-Ivaldi, F. A. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0097-8 · Cited by 469
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Cited by
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Self-citationReview of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
Biologically-inspired soft exosuit
Asbeck, A. T., Dyer, R. J., Larusson, A. F., & Walsh, C. J. (2013) · 2013 IEEE 13th International Conference on Rehabilitation Robotics (ICORR) · doi:10.1109/icorr.2013.6650455 · Cited by 240
Compliant lower limb exoskeletons: a comprehensive review on mechanical design principles
Sanchez-Villamañan, M. D. C., Gonzalez-Vargas, J., Torricelli, D., Moreno, J. C., & Pons, J. L. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0517-9 · Cited by 224
Wearable lower limb robotics: A review
Viteckova, S., Kutilek, P., & Jirina, M. (2013) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2013.03.005 · Cited by 221
Development of Active Lower Limb Robotic-Based Orthosis and Exoskeleton Devices: A Systematic Review
Kalita, B., Narayan, J., & Dwivedy, S. K. (2021) · International Journal of Social Robotics · doi:10.1007/s12369-020-00662-9 · Cited by 203
An Upper-Limb Power-Assist Exoskeleton Using Proportional Myoelectric Control
Tang, Z., Zhang, K., Sun, S., Gao, Z., Zhang, L., & Yang, Z. (2014) · Sensors · doi:10.3390/s140406677 · Cited by 182
Lee, S., Kim, J., Baker, L., Long, A., Karavas, N., Menard, N., Galiana, I., & Walsh, C. J. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0410-y · Cited by 166
Metadata
- Authors
- Sawicki, G. S., & Ferris, D. P.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2009-06-23
- Volume
- 6
- Issue
- 1
- Pages
- 23-23
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2170274344
- Cited by
- 248
- References
- 43
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.