A pneumatically powered knee-ankle-foot orthosis (KAFO) with myoelectric activation and inhibition
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The goal of this study was to test the mechanical performance of a prototype knee-ankle-foot orthosis (KAFO) powered by artificial pneumatic muscles during human walking. We had previously built a powered ankle-foot orthosis (AFO) and used it effectively in studies on human motor adaptation, locomotion energetics, and gait rehabilitation. Extending the previous AFO to a KAFO presented additional challenges related to the force-length properties of the artificial pneumatic muscles and the presence of multiple antagonistic artificial pneumatic muscle pairs. METHODS: Three healthy males were fitted with custom KAFOs equipped with artificial pneumatic muscles to power ankle plantar flexion/dorsiflexion and knee extension/flexion. Subjects walked over ground at 1.25 m/s under four conditions without extensive practice: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under direct proportional myoelectric control, and 4) wearing the orthosis activated under proportional myoelectric control with flexor inhibition produced by leg extensor muscle activation. We collected joint kinematics, ground reaction forces, electromyography, and orthosis kinetics. RESULTS: The KAFO produced approximately 22%-33% of the peak knee flexor moment, approximately 15%-33% of the peak extensor moment, approximately 42%-46% of the peak plantar flexor moment, and approximately 83%-129% of the peak dorsiflexor moment during normal walking. With flexor inhibition produced by leg extensor muscle activation, ankle (Pearson r-value = 0.74 +/- 0.04) and knee ( r = 0.95 +/- 0.04) joint kinematic profiles were more similar to the without orthosis condition compared to when there was no flexor inhibition (r = 0.49 +/- 0.13 for ankle, p = 0.05, and r = 0.90 +/- 0.03 for knee, p = 0.17). CONCLUSION: The proportional myoelectric control with flexor inhibition allowed for a more normal gait than direct proportional myoelectric control. The current orthosis design provided knee torques smaller than the ankle torques due to the trade-off in torque and range of motion that occurs with artificial pneumatic muscles. Future KAFO designs could incorporate cams, gears, or different actuators to transmit greater torque to the knee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Neptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132
Neuromechanics of Human Movement
Enoka, R. M. (2015) · Human Kinetics eBooks · doi:10.5040/9781492595632 · Cited by 703
Energetic Consequences of Walking Like an Inverted Pendulum: Step-to-Step Transitions
Kuo, A. D., Donelan, J. M., & Ruina, A. (2005) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200504000-00006 · Cited by 675
Myoelectric signal processing for control of powered limb prostheses
Parker, P., Englehart, K., & Hudgins, B. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.006 · Cited by 651
The RoboKnee: an exoskeleton for enhancing strength and endurance during walking
Pratt, J. E., Krupp, B. T., Morse, C. J., & Collins, S. H. (2004) · IEEE International Conference on Robotics and Automation, 2004. Proceedings. ICRA '04. 2004 · doi:10.1109/robot.2004.1307425 · Cited by 567
Eng, J. J., & Winter, D. A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00124-m · Cited by 481
Patton, J. L., Stoykov, M. E., Kovic, M., & Mussa-Ivaldi, F. A. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0097-8 · Cited by 469
A QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
A Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 412
Learning to move amid uncertainty
Scheidt, R. A., Dingwell, J. B., & Mussa-Ivaldi, F. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.2.971 · Cited by 411
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Self-citationModeling the Dynamic Characteristics of Pneumatic Muscle
Reynolds, D. B., Repperger, D. W., Phillips, C. A., & Bandry, G. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1554921 · Cited by 367
Power Assist System HAL-3 for Gait Disorder Person
Kawamoto, H., & Sankai, Y. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45491-8_43 · Cited by 346
An improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
Self-citationReciprocal Ia inhibition between ankle flexors and extensors in man.
Crone, C., Hultborn, H., Jespersen, B., & Nielsen, J. (1987) · The Journal of Physiology · doi:10.1113/jphysiol.1987.sp016652 · Cited by 331
Learning to walk with a robotic ankle exoskeleton
Gordon, K. E., & Ferris, D. P. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.12.006 · Cited by 318
Self-citationMechanics and energetics of level walking with powered ankle exoskeletons
Sawicki, G. S., & Ferris, D. P. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.009241 · Cited by 297
Self-citationEnergy cost and muscular activity required for propulsion during walking
Gottschall, J. S., & Kram, R. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00670.2002 · Cited by 285
Motor Adaptation as a Greedy Optimization of Error and Effort
Emken, J. L., Benitez, R., Sideris, A., Bobrow, J. E., & Reinkensmeyer, D. J. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01095.2006 · Cited by 256
Mechanical performance of artificial pneumatic muscles to power an ankle–foot orthosis
Gordon, K. E., Sawicki, G. S., & Ferris, D. P. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.018 · Cited by 223
Self-citationMechanical power and efficiency of level walking with different stride rates
Umberger, B. R., & Martin, P. E. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.000950 · Cited by 220
Powered Lower Limb Orthoses for Gait Rehabilitation
Ferris, D., Sawicki, G., & Domingo, A. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/6gl4-um7x-519h-9jyd · Cited by 214
Self-citationArtificial Muscles: Actuators for Biorobotic Systems
Klute, G. K., Czerniecki, J. M., & Hannaford, B. (2002) · The International Journal of Robotics Research · doi:10.1177/027836402320556331 · Cited by 208
THE ROLE OF ANKLE PLANTAR FLEXOR MUSCLE WORK DURING WALKING
Meinders, A. G. (1998) · Scandinavian Journal of Rehabilitation Medicine · doi:10.1080/003655098444309 · Cited by 190
A PHYSIOLOGIST'S PERSPECTIVE ON ROBOTIC EXOSKELETONS FOR HUMAN LOCOMOTION
FERRIS, D. P., SAWICKI, G. S., & DALEY, M. A. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001138 · Cited by 185
Self-citationSawicki, G. S., & Ferris, D. P. (2009) · Journal of Experimental Biology · doi:10.1242/jeb.017269 · Cited by 179
Self-citationEnhanced Modelling and Performance in Braided Pneumatic Muscle Actuators
Davis, S., Tsagarakis, N., Canderle, J., & Caldwell, D. G. (2003) · The International Journal of Robotics Research · doi:10.1177/027836403128964908 · Cited by 177
Design of an electrically actuated lower extremity exoskeleton
Zoss, A., & Kazerooni, H. (2006) · Advanced Robotics · doi:10.1163/156855306778394030 · Cited by 160
Farrell, T. R., & Weir, R. F. F. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923917 · Cited by 159
Powered Lower Limb Orthoses: Applications in Motor Adaptation and Rehabilitation
Sawicki, G. S., Gordon, K. E., & Ferris, D. P. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501086 · Cited by 157
Self-citationSmart portable rehabilitation devices
Mavroidis, C., Nikitczuk, J., Weinberg, B., Danaher, G., Jensen, K., Pelletier, P., Prugnarola, J., Stuart, R. S., Arango, R., Leahey, M., et al. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-18 · Cited by 141
Locomotor adaptation to a powered ankle-foot orthosis depends on control method
Cain, S. M., Gordon, K. E., & Ferris, D. P. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-48 · Cited by 141
Self-citationVeneman, J. F., Ekkelenkamp, R., Kruidhof, R., van der Helm, F. C. T., & van der Kooij, H. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501150 · Cited by 136
Can Robots Help the Learning of Skilled Actions?
Reinkensmeyer, D. J., & Patton, J. L. (2009) · Exercise and Sport Sciences Reviews · doi:10.1097/jes.0b013e3181912108 · Cited by 133
Effects of cadence on energy generation and absorption at lower extremity joints during gait
Teixeira‐Salmela, L. F., Nadeau, S. M., Milot, M.-H., Gravel, D., & Requião, L. F. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.02.007 · Cited by 116
Neural machine interfaces for controlling multifunctional powered upper-limb prostheses
Ohnishi, K., Weir, R. F., & Kuiken, T. A. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.1.43 · Cited by 102
Motor adaptation during dorsiflexion-assisted walking with a powered orthosis
Kao, P.-C., & Ferris, D. P. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.08.014 · Cited by 88
Self-citationSawicki, G. S., Domingo, A., & Ferris, D. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-3 · Cited by 81
Self-citationMedial Gastrocnemius Myoelectric Control of a Robotic Ankle Exoskeleton
Kinnaird, C. R., & Ferris, D. P. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008285 · Cited by 73
Self-citationMARIONET: An exotendon-driven rotary series elastic actuator for exerting joint torque
Sulzer, J. S., Peshkin, M. A., & Patton, J. L. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501062 · Cited by 50
do Nascimento, B. G., Vimieiro, C. B. S., Nagem, D. A. P., & Pinotti, M. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00549.x · Cited by 49
Cited by
Lower-Limb Robotic Rehabilitation: Literature Review and Challenges
Díaz, I., Gil, J. J., & Sánchez, E. (2011) · Journal of Robotics · doi:10.1155/2011/759764 · Cited by 541
Recent development of mechanisms and control strategies for robot-assisted lower limb rehabilitation
Meng, W., Liu, Q., Zhou, Z., Ai, Q., Sheng, B., & Xie, S. (. (2015) · Mechatronics · doi:10.1016/j.mechatronics.2015.04.005 · Cited by 464
A biologically inspired soft exosuit for walking assistance
Asbeck, A. T., De Rossi, S. M. M., Holt, K. G., & Walsh, C. J. (2015) · The International Journal of Robotics Research · doi:10.1177/0278364914562476 · Cited by 450
The exoskeleton expansion: improving walking and running economy
Sawicki, G. S., Beck, O. N., Kang, I., & Young, A. J. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00663-9 · Cited by 424
Self-citationReview of control strategies for lower-limb exoskeletons to assist gait
Baud, R., Manzoori, A. R., Ijspeert, A., & Bouri, M. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00906-3 · Cited by 381
Metadata
- Authors
- Sawicki, G. S., & Ferris, D. P.
- Venue
- Journal of NeuroEngineering and Rehabilitation
- Published
- 2009-06-23
- Volume
- 6
- Issue
- 1
- Pages
- 23-23
- ISSN
- 1743-0003 (ISSN-L)
- OpenAlex
- W2170274344
- Cited by
- 248
- References
- 43
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.