CoChat

In vitro effects of nanoparticles on renal cells

Open access
L'Azou, Béatrice, Jorly, Joana, On, Dinhill, Sellier, Elisabeth, Moisan, Frédéric, Fleury-Feith, Jocelyne, Cambar, Jean, Brochard, Patrick, Ohayon-Courtès, Céline · 2008 · Particle and Fibre Toxicology
Cited by 154

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The ability of nanoparticles to cross the lung-blood barrier suggests that they may translocate to blood and to targets distant from their portal of entry. Nevertheless, nanotoxicity in organs has received little attention. The purpose of this study was to evaluate nanotoxicity in renal cells using in vitro models. Various carbon black (CB) (FW2-13 nm, Printex60-21 nm and LB101-95 nm) and titanium dioxide (TiO2-15 and TiO2-50 nm) nanoparticles were characterized on size by electron microscopy. We evaluated theirs effects on glomerular mesangial (IP15) and epithelial proximal tubular (LLC-PK1) renal cells, using light microscopy, WST-1 assay, immunofluorescence labeling and DCFH-DA for reactive oxygen species (ROS) assay. RESULTS: Nanoparticles induced a variety of cell responses. On both IP15 and LLC-PK1 cells, the smallest FW2 NP was found to be the most cytotoxic with classic dose-behavior. For the other NPs tested, different cytotoxic profiles were found, with LLC-PK1 cells being more sensitive than IP15 cells. Exposure to FW2 NPs, evidenced in our experiments as the most cytotoxic particle type, significantly enhanced production of ROS in both IP15 and LLC-PK1 cells. Immunofluorescence microscopy using latex beads indicated that depending on their size, the cells internalized particles, which accumulated in the cell cytoplasm. Additionally using transmission electronic microscope micrographs show nanoparticles inside the cells and trapped in vesicles. CONCLUSION: The present data constitute the first step towards determining in vitro dose effect of manufactured CB and TiO2 NPs in renal cells. Cytotoxicological assays using epithelial tubular and glomerular mesangial cell lines rapidly provide information and demonstrated that NP materials exhibit varying degrees of cytotoxicity. It seems clear that in vitro cellular systems will need to be further developed, standardized and validated (relative to in vivo effects) in order to provide useful screening data about the relative toxicity of nanoparticles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1743-8977-5-22

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 154

Metadata

Authors
L'Azou, B., Jorly, J., On, D., Sellier, E., Moisan, F., Fleury-Feith, J., Cambar, J., Brochard, P., & Ohayon-Courtès, C.
Venue
Particle and Fibre Toxicology
Published
2008
Volume
5
Issue
1
Pages
22
ISSN
1743-8977 (ISSN-L)
OpenAlex
W2127335434
Cited by
154
References
5
FWCI
5.73
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vitro effects of nanoparticles on renal cells. https://app.cochat.ai/papers/10.1186/1743-8977-5-22
The paper
L'Azou, B., Jorly, J., On, D., Sellier, E., Moisan, F., Fleury-Feith, J., Cambar, J., Brochard, P., & Ohayon-Courtès, C. (2008). In vitro effects of nanoparticles on renal cells. Particle and Fibre Toxicology. https://doi.org/10.1186/1743-8977-5-22

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.