The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Open accessAbstract
BACKGROUND: Artifacts contained in EEG recordings hamper both, the visual interpretation by experts as well as the algorithmic processing and analysis (e.g. for Brain-Computer Interfaces (BCI) or for Mental State Monitoring). While hand-optimized selection of source components derived from Independent Component Analysis (ICA) to clean EEG data is widespread, the field could greatly profit from automated solutions based on Machine Learning methods. Existing ICA-based removal strategies depend on explicit recordings of an individual's artifacts or have not been shown to reliably identify muscle artifacts. METHODS: We propose an automatic method for the classification of general artifactual source components. They are estimated by TDSEP, an ICA method that takes temporal correlations into account. The linear classifier is based on an optimized feature subset determined by a Linear Programming Machine (LPM). The subset is composed of features from the frequency-, the spatial- and temporal domain. A subject independent classifier was trained on 640 TDSEP components (reaction time (RT) study, n = 12) that were hand labeled by experts as artifactual or brain sources and tested on 1080 new components of RT data of the same study. Generalization was tested on new data from two studies (auditory Event Related Potential (ERP) paradigm, n = 18; motor imagery BCI paradigm, n = 80) that used data with different channel setups and from new subjects. RESULTS: Based on six features only, the optimized linear classifier performed on level with the inter-expert disagreement (<10% Mean Squared Error (MSE)) on the RT data. On data of the auditory ERP study, the same pre-calculated classifier generalized well and achieved 15% MSE. On data of the motor imagery paradigm, we demonstrate that the discriminant information used for BCI is preserved when removing up to 60% of the most artifactual source components. CONCLUSIONS: We propose a universal and efficient classifier of ICA components for the subject independent removal of artifacts from EEG data. Based on linear methods, it is applicable for different electrode placements and supports the introspection of results. Trained on expert ratings of large data sets, it is not restricted to the detection of eye- and muscle artifacts. Its performance and generalization ability is demonstrated on data of different EEG studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“For a detailed discussion of CSP the reader is referred to [32].”
BackgroundInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Schäfer, J., & Strimmer, K. (2005) · Statistical Applications in Genetics and Molecular Biology · doi:10.2202/1544-6115.1175 · Cited by 1,561
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Self-citationCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Robust linear programming discrimination of two linearly inseparable sets
Bennett, K. P., & Mangasarian, O. L. (1992) · Optimization Methods and Software · doi:10.1080/10556789208805504 · Cited by 780
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
EMG and EOG artifacts in brain computer interface systems: A survey
Fatourechi, M., Bashashati, A., Ward, R. K., & Birch, G. E. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.10.019 · Cited by 638
Automatic removal of eye movement and blink artifacts from EEG data using blind component separation
Joyce, C. A., Gorodnitsky, I. F., & Kutas, M. (2004) · Psychophysiology · doi:10.1111/j.1469-8986.2003.00141.x · Cited by 596
Müller, K.-R., Tangermann, M., Dornhege, G., Krauledat, M., Curio, G., & Blankertz, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.022 · Cited by 474
Self-citationBlind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Semi-automatic identification of independent components representing EEG artifact
Campos Viola, F., Thorne, J., Edmonds, B., Schneider, T., Eichele, T., & Debener, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.01.015 · Cited by 364
Barbati, G., Porcaro, C., Zappasodi, F., Rossini, P. M., & Tecchio, F. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.015 · Cited by 293
James, C. J., & Gibson, O. J. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.816076 · Cited by 263
Invariant Common Spatial Patterns: Alleviating Nonstationarities in Brain-Computer Interfacing
Blankertz, B., Kawanabe, M., Tomioka, R., Hohlefeld, F. U., Nikulin, V. V., & Müller, K. R. (2008) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · Cited by 251
Ziehe, A., Laskov, P., Nolte, G., & Müller, K. (2004) · doi:10.5555/1005332.1016784 · Cited by 218
Validation of ICA-based myogenic artifact correction for scalp and source-localized EEG
McMenamin, B. W., Shackman, A. J., Maxwell, J. S., Bachhuber, D. R. W., Koppenhaver, A. M., Greischar, L. L., & Davidson, R. J. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.010 · Cited by 211
Some periodic phenomena arising during drowsiness and sleep in man
Lugaresi, E., Coccagna, G., Mantovani, M., & Lebrun, R. (1972) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(72)90106-x · Cited by 202
Romero, S., Mañanas, M. A., & Barbanoj, M. J. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2007.12.001 · Cited by 191
LeVan, P., Urrestarazu, E., & Gotman, J. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.12.013 · Cited by 166
Artifact removal from electroencephalograms using a hybrid BSS-SVM algorithm
Shoker, L., Sanei, S., & Chambers, J. (2005) · IEEE Signal Processing Letters · doi:10.1109/lsp.2005.855539 · Cited by 160
Arnaud Delorme, A., Makeig, S., B, T. J. S. A., & Pines, N. T. (2001) · Cited by 154
Muscle Artifact Removal from Human Sleep EEG by Using Independent Component Analysis
Crespo‐García, M., Atienza, M., & Cantero, J. L. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9442-y · Cited by 138
Combining sparsity and rotational invariance in EEG/MEG source reconstruction
Haufe, S., Nikulin, V. V., Ziehe, A., Müller, K.-R., & Nolte, G. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.04.246 · Cited by 130
Self-citationEffects of eyelid closure, blinks, and eye movements on the electroencephalogram
Iwasaki, M., Kellinghaus, C., Alexopoulos, A. V., Burgess, R. C., Kumar, A. N. S., HAN, Y. H., Lüders, H. O., & Leigh, R. J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2004.11.001 · Cited by 127
Halder, S., Bensch, M., Mellinger, J., Bogdan, M., Kübler, A., Birbaumer, N., & Rosenstiel, W. (2007) · Computational Intelligence and Neuroscience · doi:10.1155/2007/82069 · Cited by 123
Removal of EEG Noise and Artifact Using Blind Source Separation
Fitzgibbon, S. P., Powers, D. M. W., Pope, K. J., & Clark, C. R. (2007) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e3180556926 · Cited by 104
Delayed verbal reactions are specifically impaired in patients with schizophrenia
Pinelli, P., Ceriani, F., Colombo, R., Pasetti, C., Terazzi, M., & Castignoli, G. (2000) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(00)00088-x · Cited by 37
Robust common spatial filters with a maxmin approach
Kawanabe, M., Vidaurre, C., Scholler, S., & Müller, K. R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334786 · Cited by 17
Cited by
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationChaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Metadata
- Authors
- Winkler, I., Haufe, S., & Tangermann, M.
- Venue
- Behavioral and Brain Functions
- Published
- 2011
- Volume
- 7
- Issue
- 1
- Pages
- 30
- ISSN
- 1744-9081 (ISSN-L)
- OpenAlex
- W2113412631
- Cited by
- 778
- References
- 36
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.