Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Artifacts contained in EEG recordings hamper both, the visual interpretation by experts as well as the algorithmic processing and analysis (e.g. for Brain-Computer Interfaces (BCI) or for Mental State Monitoring). While hand-optimized selection of source components derived from Independent Component Analysis (ICA) to clean EEG data is widespread, the field could greatly profit from automated solutions based on Machine Learning methods. Existing ICA-based removal strategies depend on explicit recordings of an individual's artifacts or have not been shown to reliably identify muscle artifacts. METHODS: We propose an automatic method for the classification of general artifactual source components. They are estimated by TDSEP, an ICA method that takes temporal correlations into account. The linear classifier is based on an optimized feature subset determined by a Linear Programming Machine (LPM). The subset is composed of features from the frequency-, the spatial- and temporal domain. A subject independent classifier was trained on 640 TDSEP components (reaction time (RT) study, n = 12) that were hand labeled by experts as artifactual or brain sources and tested on 1080 new components of RT data of the same study. Generalization was tested on new data from two studies (auditory Event Related Potential (ERP) paradigm, n = 18; motor imagery BCI paradigm, n = 80) that used data with different channel setups and from new subjects. RESULTS: Based on six features only, the optimized linear classifier performed on level with the inter-expert disagreement (<10% Mean Squared Error (MSE)) on the RT data. On data of the auditory ERP study, the same pre-calculated classifier generalized well and achieved 15% MSE. On data of the motor imagery paradigm, we demonstrate that the discriminant information used for BCI is preserved when removing up to 60% of the most artifactual source components. CONCLUSIONS: We propose a universal and efficient classifier of ICA components for the subject independent removal of artifacts from EEG data. Based on linear methods, it is applicable for different electrode placements and supports the introspection of results. Trained on expert ratings of large data sets, it is not restricted to the detection of eye- and muscle artifacts. Its performance and generalization ability is demonstrated on data of different EEG studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046
Independent Component Analysis of Electroencephalographic Data
Makeig, S., Bell, A. J., Jung, T., & B, T. J. S. A. (1995) · neural information processing systems · Cited by 2,476
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 1×
“For a detailed discussion of CSP the reader is referred to [32].”
BackgroundInterpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Schäfer, J., & Strimmer, K. (2005) · Statistical Applications in Genetics and Molecular Biology · doi:10.2202/1544-6115.1175 · Cited by 1,561
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Self-citationCombining brain-computer interfaces and assistive technologies: state-of-the-art and challenges
Millán, J. D. R. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00161 · Cited by 866
Cited by
ICLabel: An automated electroencephalographic independent component classifier, dataset, and website
Pion-Tonachini, L., Kreutz-Delgado, K., & Makeig, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.026 · Cited by 2,267
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationChaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00097 · Cited by 535
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Self-citationSmith, E. E., Reznik, S. J., Stewart, J. L., & Allen, J. J. B. (2017) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2016.11.005 · Cited by 335
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
Self-citationAutomagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
A survey of affective brain computer interfaces: principles, state-of-the-art, and challenges
Mühl, C., Allison, B., Nijholt, A., & Chanel, G. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2014.912881 · Cited by 282
Delorme, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-27528-0 · Cited by 260
Identification and Removal of Physiological Artifacts From Electroencephalogram Signals: A Review
Mannan, M. M. N., Kamran, M. A., & Jeong, M. Y. (2018) · IEEE Access · doi:10.1109/access.2018.2842082 · Cited by 222
“statistical tools to automatically classify artifactual components [12], [23], [92], [115], [198], [216], [222] (see Table 4).”
BackgroundMethodOptimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Dimigen, O. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116117 · Cited by 222
“Non-ocular artifacts such as cardiac activity show similar variance during both intervals and are not fl agged; they can be detected with other techniques (Campos Viola et al., 2009; Chaumon et al., 2015; Mognon et al., 2011; Nolan et al., 2010; Winkler et al., 2011).”
BackgroundEEG power spectral slope differs by ADHD status and stimulant medication exposure in early childhood
Robertson, M. M., Furlong, S., Voytek, B., Donoghue, T., Boettiger, C. A., & Sheridan, M. A. (2019) · Journal of Neurophysiology · doi:10.1152/jn.00388.2019 · Cited by 203
“The ICA decomposition was then calculated in EEGLAB, and we used the MARA EEGLAB plug-in (Winkler et al. 2011, 2014).”
MethodMethodological aspects of EEG and body dynamics measurements during motion
Reis, P. M. R., Hebenstreit, F., Gabsteiger, F., von Tscharner, V., & Lochmann, M. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00156 · Cited by 159
“Automatic selection with MARA (Winkler et al., 2011), http://www.user.tu-berlin.de/irene.winkler/artifacts/ or ACEMIC (Gabsteiger et al., 2013) available at http://www5.cs.fau.de/research/areas/digital-sports/ automatic-classification-of-electromyogenic-ica-components/.”
MethodInfluentialThe self and its prolonged intrinsic neural timescale in schizophrenia
Northoff, G., Sandsten, K. E., Nordgaard, J., Kjaer, T. W., & Parnas, J. (2021) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaa083 · Cited by 91
Chuang, C.-H., Chang, K.-Y., Huang, C.-S., & Jung, T.-P. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119586 · Cited by 88
Stuldreher, I. V., Thammasan, N., van Erp, J. B. F., & Brouwer, A.-M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba87d · Cited by 58
“Independent component analysis was performed and the Multiple Artifact Rejection Algorithm (Winkler et al 2011) was used to classify artefactual independent components, i.e. components not reflecting sources of neural activity, but ocular or muscle-related activity.”
MethodSignal Artifacts and Techniques for Artifacts and Noise Removal
Islam, M. K., Rastegarnia, A., & Sanei, S. (2021) · Intelligent Systems Reference Library · doi:10.1007/978-3-030-54932-9_2 · Cited by 54
Arciniega, H., Shires, J., Furlong, S., Kilgore-Gomez, A., Cerreta, A., Murray, N. G., & Berryhill, M. E. (2021) · Scientific Reports · doi:10.1038/s41598-021-80995-1 · Cited by 33
Temporally resolved neural dynamics underlying handwriting
Pei, L., Longcamp, M., Leung, F. K.-S., & Ouyang, G. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118578 · Cited by 23
Yao, B., Taylor, J. R., Banks, B., & Kotz, S. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118313 · Cited by 16
“Artifact comonents were identified using a semi-automated procedure: Components or eye blinks and muscular artifacts were classified automatically using he EEGLAB extension ‘MARA’ ( Winkler et al., 2011 ).”
MethodGupta, A., Wolff, A., & Northoff, D. G. (2021) · Psychiatry Research: Neuroimaging · doi:10.1016/j.pscychresns.2021.111367 · Cited by 13
Berwian, I. M., Tröndle, M., Miquel, C. D., Ziogas, A., Stefanics, G., Walter, H., Stephan, K. E., & Huys, Q. J. M. (2023) · doi:10.1101/2023.07.05.547831 · Cited by 2
Metadata
- Authors
- Winkler, I., Haufe, S., & Tangermann, M.
- Venue
- Behavioral and Brain Functions
- Published
- 2011
- Volume
- 7
- Issue
- 1
- Pages
- 30
- ISSN
- 1744-9081 (ISSN-L)
- OpenAlex
- W2113412631
- Cited by
- 778
- References
- 36
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.