Impedance-based cell monitoring: barrier properties and beyond
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
In multicellular organisms epithelial and endothelial cells form selective permeable interfaces between tissue compartments of different chemical compositions. Tight junctions which connect adjacent cells, control the passage of molecules across the barrier and, in addition, facilitate active transport processes. The cellular barriers are not static but can be deliberately modulated by exposure to specific external stimuli. In vitro models representing the essential absorption barriers of the body are nowadays available, thus allowing investigation of the parameters that control permeability as well as transport processes across those barriers. Independent of the origin of the barrier forming cells, techniques are needed to quantify their barrier integrity. One simple assay is to measure the permeability for given hydrophilic substrates possessing different molecular weights like sucrose or dextrans. However, this technique is time-consuming and labor-intensive. Moreover, radioactive or fluorescently-labeled substrates are needed to allow easy analytical detection. Finally, if transport processes are investigated, the standard permeant may interfere with the transport process under investigation or might even alter the barrier integrity by itself. Thus, independent, non-invasive techniques are needed to quantify the barrier integrity continuously during the experiment. Such techniques are available and are mainly based on the measurement of the transendothelial or transepithelial electrical resistance (TEER) of barrier forming cells grown on porous membranes. Simple devices using two sets of electrodes (so-called Voltohmeters) are widely used. In addition, an easy-to-use physical technique called impedance spectroscopy allows the continuous analysis of both the TEER and the electrical capacitance giving additional information about the barrier properties of cells grown on permeable membranes. This technique is useful as a quality control for barrier forming cells. Another impedance-based approach requires cells to be grown directly on solid, micro-structured electrodes. Here, we will discuss the physical background of the different techniques; advantages, disadvantages, and applications will be scrutinized. The aim is to give the reader a comprehensive understanding concerning the range and limits of the application, mainly focusing on endothelial cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Armstrong, R. D. (1988) · Electrochimica Acta · doi:10.1016/0013-4686(88)80076-8 · Cited by 1,945
(2015) · Multiforms, Dyadics, and Electromagnetic Media · doi:10.1002/9781119052388.ch5 · Cited by 884
Micromotion of mammalian cells measured electrically.
Giaever, I., & Keese, C. R. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.17.7896 · Cited by 828
Wegener, J., Keese, C. R., & Giaever, I. (2000) · Experimental Cell Research · doi:10.1006/excr.2000.4919 · Cited by 769
A new blood–brain barrier model using primary rat brain endothelial cells, pericytes and astrocytes
Nakagawa, S., Deli, M. A., Kawaguchi, H., Shimizudani, T., Shimono, T., Kittel, Á., Tanaka, K., & Niwa, M. (2009) · Neurochemistry International · doi:10.1016/j.neuint.2008.12.002 · Cited by 728 · cited 1×
“[27].”
Microscopy: Science, Technology, Applications and Education
Mari, M. C., Griffith, J. M., & Reggiori, F. (2010) · Cited by 669
Permeability Studies on In Vitro Blood–Brain Barrier Models: Physiology, Pathology, and Pharmacology
Deli, M. A., Ábrahám, C. S., Kataoka, Y., & Niwa, M. (2005) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-004-1377-8 · Cited by 643
An Easier, Reproducible, and Mass‐Production Method to Study the Blood–Brain Barrier In Vitro
Dehouck, M., Méresse, S., Delorme, P., Fruchart, J., & Cecchelli, R. (1990) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1990.tb01236.x · Cited by 547
Osmotic Opening of the Blood–Brain Barrier: Principles, Mechanism, and Therapeutic Applications
Rapoport, S. I. (2000) · Cellular and Molecular Neurobiology · doi:10.1023/a:1007049806660 · Cited by 428 · cited 1×
“However, the barrier is not static but can be modulated by specific stimuli to open and close selectively, thus allowing controlled passage from the blood to the brain or vice versa [2-4].”
Background
Cited by
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Helms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
“The well-differentiated tight junctions of the model make it ideal for examining tight junction expression and modulation, and it has been the model of choice to introduce impedance analysis as a technique to continuously measure TEER in BBB models.(231,232) A recent quantitative proteomics comparison of isolated brai…”
MethodSelf-citationEigenmann, D. E., Xue, G., Kim, K. S., Moses, A. V., Hamburger, M., & Oufir, M. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-33 · Cited by 421
Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Organic Electrochemical Transistors with Maximum Transconductance at Zero Gate Bias
Rivnay, J., Leleux, P., Sessolo, M., Khodagholy, D., Hervé, T., Fiocchi, M., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201303080 · Cited by 300
Nutritional Keys for Intestinal Barrier Modulation
De Santis, S., Cavalcanti, E., Mastronardi, M., Jirillo, E., & Chieppa, M. (2015) · Frontiers in Immunology · doi:10.3389/fimmu.2015.00612 · Cited by 232
The intestinal barrier as an emerging target in the toxicological assessment of mycotoxins
Akbari, P., Braber, S., Varasteh, S., Alizadeh, A., Garssen, J., & Fink-Gremmels, J. (2017) · Archives of Toxicology · doi:10.1007/s00204-016-1794-8 · Cited by 211
“…continuous recording of cellular horizontal impedance, which enables a real-time monitoring of the integrity of the epithelial barrier and the potential effects of toxins and other agents that affect barrier integrity (Abassi et al. 2009; Akbari et al. 2014; Benson et al. 2013; Sun et al. 2012).”
BackgroundMeasuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Mechanical stress regulates transport in a compliant 3D model of the blood-brain barrier
Partyka, P. P., Godsey, G. A., Galie, J. R., Kosciuk, M. C., Acharya, N. K., Nagele, R. G., & Galie, P. A. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2016.11.012 · Cited by 179
Advances in Engineering Human Tissue Models
Moysidou, C.-M., Barberio, C., & Owens, R. M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620962 · Cited by 179
“In fact, EIS is widely used for monitoring Transepithelial/Transendothelial Electrical Resistance (TEER), a commonly used parameter to quantitatively characterize the function and integrity of tissue barriers with fast, non-invasive measurements (Benson et al., 2013; De León et al., 2020).”
MethodMultiorgan Microphysiological Systems for Drug Development: Strategies, Advances, and Challenges
Wang, Y. I., Carmona, C., Hickman, J. J., & Shuler, M. L. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701000 · Cited by 167
van der Helm, M. W., Henry, O. Y. F., Bein, A., Hamkins-Indik, T., Cronce, M. J., Leineweber, W. D., Odijk, M., van der Meer, A. D., Eijkel, J. C. T., Ingber, D. E., et al. (2019) · Lab on a Chip · doi:10.1039/c8lc00129d · Cited by 161
Song, J., Zhang, X., Buscher, K., Wang, Y., Wang, H., Di Russo, J., Li, L., Lütke-Enking, S., Zarbock, A., Stadtmann, A., et al. (2017) · Cell Reports · doi:10.1016/j.celrep.2016.12.092 · Cited by 159
Dizzell, S., Nazli, A., Reid, G., & Kaushic, C. (2019) · Cells · doi:10.3390/cells8101120 · Cited by 30
Metadata
- Authors
- Benson, K., Cramer, S., & Galla, H.-J.
- Venue
- Fluids and Barriers of the CNS
- Published
- 2013-01-10
- Volume
- 10
- Issue
- 1
- Pages
- 5-5
- ISSN
- 2045-8118 (ISSN-L)
- OpenAlex
- W2109824567
- Cited by
- 400
- References
- 33
- FWCI
- 10.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.