Characterization of tissue oxygen saturation and the vascular occlusion test: influence of measurement sites, probe sizes and deflation thresholds
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Tissue oxygen saturation (StO2) and the vascular occlusion test (VOT) can identify tissue hypoperfusion in trauma and sepsis. However, the technique is neither standardized nor uses the same monitoring site. We hypothesized that baseline and VOT StO2 would be different in the forearm (F) and thenar eminence (TH) and that different minimal StO2 values during the VOT would result in different reoxygenation rates (ReO2). METHODS: StO2 and its change during the VOT were simultaneously measured in the F and TH, with 15 mm and 25 mm probes, using the 325 InSpectra monitor in 18 healthy, adult volunteers. Two VOTs were done to a threshold thenar StO2 of 40% interchanging the 15 mm and 25 mm probes between sites. Two additional VOTs were done to thresholds of 50% and 30%. Baseline StO2 (BaseO2), the deoxygenation rate (DeO2) and ReO2 were compared between sites, probes and (%O2/minute) thresholds. Results are presented as the median (interquartile range), P-value. RESULTS: BaseO2, DeO2, ReO2, area under the curve and hyperemia duration values were different when comparing TH vs. F and 15 mm vs. 25 mm probes. ReO2 was different between different thresholds for the TH and 15 mm probes. TH15 mm vs. F15 mm: BaseO2, 90.4 (85.2, 93.5) vs. 85.2 (80.7, 90.2), P = 0.031; DO2, -12.1 (-16.2, -11.3) vs. -8.5 (-10.3, -7.8), P = 0.011; ReO2, 297.2 (213.7, 328.6), P < 0.0001; 15 mm vs. 25 mm probe: BaseO2, 97.2 (89.4, 94.7) vs. 87.3 (81.7, 90.9), P = 0.016; DeO2, -18.0 (-24.1, -14.8) vs. -9.9 (-15.3, -6.5), P < 0.0001; and ReO2, 401.6 (331.7, 543.2) vs. 160.5 (132.3, 366.9), P = 0.012, respectively. TH15 mm vs. TH25 mm: BaseO2, P = 0.020; DeO2, P < 0.0001; and ReO2, P < 0.0001. Threshold StO2 values (15 mm probe only): ReO2, P = 0.003; DeO2, P = 0.60. ReO2 at 40% and 50% StO2 thresholds, P = 0.01. CONCLUSIONS: BaseO2, DeO2 and ReO2 were different when measured in different anatomical sites (F and TH) and with different probe sizes, and ReO2 was different with differing VOT release StO2 threshold values. Thus, standardization of the site, probe and VOT challenge need to be stipulated when reporting data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These differences focus around interindividual and intersite (muscle site selection) variation in results.10,11”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [10]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The differences between monitors are likely to be in part associated with the measurement site and spacing of the probes. 16,17”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The prognostic value of muscle StO2 in septic patients
Creteur, J., Carollo, T., Soldati, G., Buchele, G., De Backer, D., & Vincent, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0739-3 · Cited by 355
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294 · cited 3×
“This result was expected given that the DeO2 is dependent on the metabolic conditions of the tissue, independent of the intensity of the ischemic insult and given the specific calculation methodology [1].”
BackgroundSelf-citationNoninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., et al. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000158269.68409.1c · Cited by 211 · cited 1×
“The absolute StO2 has been proven instrumental in predicting outcome in trauma patients [1,2].”
BackgroundGómez, H., Torres, A., Polanco, P., Kim, H. K., Zenker, S., Puyana, J. C., & Pinsky, M. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1145-1 · Cited by 206 · cited 1×
“Furthermore, the use of such provocative tests [3], specifically the vascular occlusion test (VOT), has been shown to improve and expand the predictive ability of StO 2 to scenarios such as trauma, severe sepsis and septic shock [4, 5 ].”
BackgroundSelf-citationDYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS
Skarda, D. E., Mulier, K. E., Myers, D. E., Taylor, J. H., & Beilman, G. J. (2007) · Shock · doi:10.1097/01.shk.0000239779.25775.e4 · Cited by 183 · cited 1×
“25 mm) [4,8-12], and different types and levels of deflation thresholds (StO2 of 40%, 50%) versus time thresholds (3 minutes, 4 minutes, 5 minutes) [4,6,11,13].”
BackgroundPhysiological and Medical Monitoring for En Route Care of Combat Casualties
Convertino, V. A., Ryan, K. L., Rickards, C. A., Salinas, J., McManus, J. G., Cooke, W. H., & Holcomb, J. B. (2008) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31816c82f4 · Cited by 129 · cited 2×
“Furthermore, the use of such provocative tests [3], specifically the vascular occlusion test (VOT), has been shown to improve and expand the predictive ability of StO2 to scenarios such as trauma, severe sepsis and septic shock [4,5].”
BackgroundMuscle StO2 in critically ill patients
Creteur, J. (2008) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282fad4e1 · Cited by 100 · cited 1×
“Finally, since the primary reason to perform the VOT is to produce a transient ischaemic challenge to note the subsequent ReO2, the level of ischaemic challenge might vary for the same ischaemic time or threshold StO 2 . As a consequence, caution must be taken when comparing results from the available literature on th…”
ResultSoller, B. R., Ryan, K. L., Rickards, C. A., Cooke, W. H., Yang, Y., Soyemi, O. O., Crookes, B., Heard, S. O., & Convertino, V. A. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000295586.83787.7e · Cited by 76 · cited 2×
“In fact, multiple studies report results using different anatomical StO2 measuring sites (TH, forearm (F), deltoid) [4,6-8], different near-infrared spectroscopy probe sizes (15 mm vs.”
BackgroundPodbregar, M., & Možina, H. (2007) · Critical Care · doi:10.1186/cc5153 · Cited by 69 · cited 1×
“In fact, multiple studies report results using different anatomical StO2 measuring sites (TH, forearm (F), deltoid) [4,6-8], different near-infrared spectroscopy probe sizes (15 mm vs.”
BackgroundAcute Effects of Smoking on Skeletal Muscle Microcirculation Monitored by Near-Infrared Spectroscopy
Siafaka, A., Angelopoulos, E. T., Kritikos, K., Poriazi, M., Basios, N., Gerovasili, V., Andreou, A., Roussos, C., & Nanas, S. (2007) · CHEST Journal · doi:10.1378/chest.06-2017 · Cited by 68 · cited 1×
“25 mm) [4,8-12], and different types and levels of deflation thresholds (StO2 of 40%, 50%) versus time thresholds (3 minutes, 4 minutes, 5 minutes) [4,6,11,13].”
BackgroundYang, Y., Soyemi, O. O., Scott, P. J., Landry, M. R., Lee, S. M. C., Stroud, L., & Soller, B. R. (2007) · Optics Express · doi:10.1364/oe.15.013715 · Cited by 49 · cited 1×
“25 mm) [4,8-12], and different types and levels of deflation thresholds (StO2 of 40%, 50%) versus time thresholds (3 minutes, 4 minutes, 5 minutes) [4,6,11,13].”
BackgroundMuscle Oxygenation by Fast Near Infrared Spectrophotometry (NIRS) in Ischemic Forearm
Blasi, R. A. D., Quaglia, E., GASPARETTO, A., & Ferrari, M. (1992) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-3404-4_19 · Cited by 15
İnce, C., Bezemer, R., & Lima, A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181932d42 · Cited by 14
Self-citation
Research works printed but not linked: 1
- Gomez H Torres A Polanco P Kim HK Zenker S Puyana JC Pinsky MR Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O2 saturation response Intensive Care Med 2008 34 1600 1607 10.1007/s00134-008-1145-1 18523754 · DOI · Paper page
Cited by
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
“These differences focus around interindividual and intersite (muscle site selection) variation in results.(10,11) When choosing a new muscle site or changing test participant altogether, the optical properties measured by the NIRS device changes.”
BackgroundDoerschug, K. C., Delsing, A. S., Schmidt, G. A., & Ashare, A. (2010) · Critical Care · doi:10.1186/cc8887 · Cited by 119
“The coefficient of variability of the reoxygenation rate in normal control subjects was 23%, similar to previous reports [25].”
ResultNear infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
Lipcsey, M., Woinarski, N. C. Z., & Bellomo, R. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-11 · Cited by 126
“Moreover, the methodology of NIRS is not standardized [87,88].”
MethodWiese, M., Bashmakov, Y. K., Chalyk, N. E., Nielsen, D. S., Krych, Ł., Kot, W., Klochkov, V. A., Pristensky, D. V., Bandaletova, T. Y., Chernyshova, M. P., et al. (2019) · BioMed Research International · doi:10.1155/2019/4625279 · Cited by 116
Metadata
- Authors
- Gómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R.
- Affiliations
- University of Pittsburgh (US)
- Universitat Autònoma de Barcelona (ES)
- Corresponding author
- Pinsky, Michael R
- Venue
- Critical Care
- Published
- 2009-11-30
- Volume
- 13
- Issue
- S5
- Pages
- S3-S3
- ISSN
- 1364-8535 (ISSN-L)
- PMC
- PMC2786105
- OpenAlex
- W1967705433
- Semantic Scholar
- 73960e7e00fbf26d07e99ff69b5c353dbacbf50d
- Cited by
- 94
- References
- 14
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 3 · 2019: 11 · 2018: 4 · 2017: 6 · 2016: 12 · 2015: 10 · 2014: 6 · 2013: 5 · 2012: 9
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Critical Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion)
- D-Scholarship@Pitt (University of Pittsburgh) (acceptedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Funders
- University of Pittsburgh
- National Heart, Lung, and Blood Institute (R01HL076157, HL76157, HL 67181, K24HL067181, T32HL007820)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- tissue oxygen saturation, vascular occlusion test, tissue hypoperfusion, measurement site, thenar eminence, forearm, probe size, trauma (physical injury), sepsis, hyperemia, deoxygenation rate, standardized monitoring protocols, measurement reproducibility
- MeSH terms
- Adolescent, Adult, Female, Forearm, Humans, Male, Oxygen Consumption, Vascular Diseases, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.