Characterization of tissue oxygen saturation and the vascular occlusion test: influence of measurement sites, probe sizes and deflation thresholds
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Tissue oxygen saturation (StO2) and the vascular occlusion test (VOT) can identify tissue hypoperfusion in trauma and sepsis. However, the technique is neither standardized nor uses the same monitoring site. We hypothesized that baseline and VOT StO2 would be different in the forearm (F) and thenar eminence (TH) and that different minimal StO2 values during the VOT would result in different reoxygenation rates (ReO2). METHODS: StO2 and its change during the VOT were simultaneously measured in the F and TH, with 15 mm and 25 mm probes, using the 325 InSpectra monitor in 18 healthy, adult volunteers. Two VOTs were done to a threshold thenar StO2 of 40% interchanging the 15 mm and 25 mm probes between sites. Two additional VOTs were done to thresholds of 50% and 30%. Baseline StO2 (BaseO2), the deoxygenation rate (DeO2) and ReO2 were compared between sites, probes and (%O2/minute) thresholds. Results are presented as the median (interquartile range), P-value. RESULTS: BaseO2, DeO2, ReO2, area under the curve and hyperemia duration values were different when comparing TH vs. F and 15 mm vs. 25 mm probes. ReO2 was different between different thresholds for the TH and 15 mm probes. TH15 mm vs. F15 mm: BaseO2, 90.4 (85.2, 93.5) vs. 85.2 (80.7, 90.2), P = 0.031; DO2, -12.1 (-16.2, -11.3) vs. -8.5 (-10.3, -7.8), P = 0.011; ReO2, 297.2 (213.7, 328.6), P < 0.0001; 15 mm vs. 25 mm probe: BaseO2, 97.2 (89.4, 94.7) vs. 87.3 (81.7, 90.9), P = 0.016; DeO2, -18.0 (-24.1, -14.8) vs. -9.9 (-15.3, -6.5), P < 0.0001; and ReO2, 401.6 (331.7, 543.2) vs. 160.5 (132.3, 366.9), P = 0.012, respectively. TH15 mm vs. TH25 mm: BaseO2, P = 0.020; DeO2, P < 0.0001; and ReO2, P < 0.0001. Threshold StO2 values (15 mm probe only): ReO2, P = 0.003; DeO2, P = 0.60. ReO2 at 40% and 50% StO2 thresholds, P = 0.01. CONCLUSIONS: BaseO2, DeO2 and ReO2 were different when measured in different anatomical sites (F and TH) and with different probe sizes, and ReO2 was different with differing VOT release StO2 threshold values. Thus, standardization of the site, probe and VOT challenge need to be stipulated when reporting data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These differences focus around interindividual and intersite (muscle site selection) variation in results.10,11”
From Near-infrared spectroscopy-derived muscle oxygen saturation on a 0% to 100% scale: reliability and validity of the Moxy Monitor (2019) · cites this paper as [10]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The differences between monitors are likely to be in part associated with the measurement site and spacing of the probes. 16,17”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [17]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The prognostic value of muscle StO2 in septic patients
Creteur, J., Carollo, T., Soldati, G., Buchele, G., De Backer, D., & Vincent, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0739-3 · Cited by 355
Cohn, S. M., Nathens, A. B., Moore, F. A., Rhee, P., Puyana, J. C., Moore, E. E., & Beilman, G. J. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31802eb817 · Cited by 294 · cited 3×
“This result was expected given that the DeO2 is dependent on the metabolic conditions of the tissue, independent of the intensity of the ischemic insult and given the specific calculation methodology [1].”
BackgroundSelf-citationNoninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Can Near-Infrared Spectroscopy Identify the Severity of Shock in Trauma Patients?
Crookes, B. A., Cohn, S. M., Bloch, S., Amortegui, J., Manning, R., Li, P., Proctor, M. S., Hallal, A., Blackbourne, L. H., Benjamin, R., et al. (2005) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000158269.68409.1c · Cited by 211 · cited 1×
“The absolute StO2 has been proven instrumental in predicting outcome in trauma patients [1,2].”
BackgroundGómez, H., Torres, A., Polanco, P., Kim, H. K., Zenker, S., Puyana, J. C., & Pinsky, M. R. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1145-1 · Cited by 206 · cited 1×
“Furthermore, the use of such provocative tests [3], specifically the vascular occlusion test (VOT), has been shown to improve and expand the predictive ability of StO 2 to scenarios such as trauma, severe sepsis and septic shock [4, 5 ].”
BackgroundSelf-citationDYNAMIC NEAR-INFRARED SPECTROSCOPY MEASUREMENTS IN PATIENTS WITH SEVERE SEPSIS
Skarda, D. E., Mulier, K. E., Myers, D. E., Taylor, J. H., & Beilman, G. J. (2007) · Shock · doi:10.1097/01.shk.0000239779.25775.e4 · Cited by 183 · cited 1×
“25 mm) [4,8-12], and different types and levels of deflation thresholds (StO2 of 40%, 50%) versus time thresholds (3 minutes, 4 minutes, 5 minutes) [4,6,11,13].”
BackgroundPhysiological and Medical Monitoring for En Route Care of Combat Casualties
Convertino, V. A., Ryan, K. L., Rickards, C. A., Salinas, J., McManus, J. G., Cooke, W. H., & Holcomb, J. B. (2008) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e31816c82f4 · Cited by 129 · cited 2×
“Furthermore, the use of such provocative tests [3], specifically the vascular occlusion test (VOT), has been shown to improve and expand the predictive ability of StO2 to scenarios such as trauma, severe sepsis and septic shock [4,5].”
BackgroundMuscle StO2 in critically ill patients
Creteur, J. (2008) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282fad4e1 · Cited by 100 · cited 1×
“Finally, since the primary reason to perform the VOT is to produce a transient ischaemic challenge to note the subsequent ReO2, the level of ischaemic challenge might vary for the same ischaemic time or threshold StO 2 . As a consequence, caution must be taken when comparing results from the available literature on th…”
ResultSoller, B. R., Ryan, K. L., Rickards, C. A., Cooke, W. H., Yang, Y., Soyemi, O. O., Crookes, B., Heard, S. O., & Convertino, V. A. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0000295586.83787.7e · Cited by 76 · cited 2×
“In fact, multiple studies report results using different anatomical StO2 measuring sites (TH, forearm (F), deltoid) [4,6-8], different near-infrared spectroscopy probe sizes (15 mm vs.”
BackgroundPodbregar, M., & Možina, H. (2007) · Critical Care · doi:10.1186/cc5153 · Cited by 69 · cited 1×
“In fact, multiple studies report results using different anatomical StO2 measuring sites (TH, forearm (F), deltoid) [4,6-8], different near-infrared spectroscopy probe sizes (15 mm vs.”
Background
Research works printed but not linked: 1
- Gomez H Torres A Polanco P Kim HK Zenker S Puyana JC Pinsky MR Use of non-invasive NIRS during a vascular occlusion test to assess dynamic tissue O2 saturation response Intensive Care Med 2008 34 1600 1607 10.1007/s00134-008-1145-1 18523754 · DOI · Paper page
Cited by
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Feldmann, A., Schmitz, R. W., & Erlacher, D. (2019) · Journal of Biomedical Optics · doi:10.1117/1.jbo.24.11.115001 · Cited by 203
“These differences focus around interindividual and intersite (muscle site selection) variation in results.(10,11) When choosing a new muscle site or changing test participant altogether, the optical properties measured by the NIRS device changes.”
BackgroundDoerschug, K. C., Delsing, A. S., Schmidt, G. A., & Ashare, A. (2010) · Critical Care · doi:10.1186/cc8887 · Cited by 119
“The coefficient of variability of the reoxygenation rate in normal control subjects was 23%, similar to previous reports [25].”
ResultNear infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care
Lipcsey, M., Woinarski, N. C. Z., & Bellomo, R. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-11 · Cited by 126
“Moreover, the methodology of NIRS is not standardized [87,88].”
MethodWiese, M., Bashmakov, Y. K., Chalyk, N. E., Nielsen, D. S., Krych, Ł., Kot, W., Klochkov, V. A., Pristensky, D. V., Bandaletova, T. Y., Chernyshova, M. P., et al. (2019) · BioMed Research International · doi:10.1155/2019/4625279 · Cited by 116
Mayeur, C., Campard, S., Richard, C., & Teboul, J.-L. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206d256 · Cited by 91
“were found to differ depending on probe spacing, probe placement, and the predefined StO2 target (8, 9).”
BackgroundMethodResultInfluentialZuccari, S., Damiani, E., Domizi, R., Scorcella, C., D'Arezzo, M., Carsetti, A., Pantanetti, S., Vannicola, S., Casarotta, E., Ranghino, A., et al. (2019) · Blood Purification · doi:10.1159/000502540 · Cited by 93
Near-Infrared Spectroscopy: The New Must Have Tool in the Intensive Care Unit?
Green, M. S., Sehgal, S., & Tariq, R. (2016) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253216644346 · Cited by 100
“45 There is regretfully no consensus of opinion as to the exact method to use or which site is best in VOT.46 Some authors suggest maintaining ischemia for a specific time while other suggest a method in which StO 2 drops to a certain value (Figure 3).”
MethodThe microcirculation and its measurement in sepsis
Charlton, M., Sims, M. R., Coats, T., & Thompson, J. P. (2016) · Journal of the Intensive Care Society · doi:10.1177/1751143716678638 · Cited by 76
“Desaturation and resaturation slopes after a VOT.(29) Charlton et al.”
BackgroundAssessment of Regional Perfusion and Organ Function: Less and Non-invasive Techniques
Huber, W., Zanner, R., Schneider, G. H., Schmid, R. M., & Lahmer, T. (2019) · Frontiers in Medicine · doi:10.3389/fmed.2019.00050 · Cited by 89
Mesquida, J., Gruartmoner, G., & Espinal, C. (2013) · BioMed Research International · doi:10.1155/2013/502194 · Cited by 95
“According to the existing literature [14, 25], maintaining the ischemic stimulus until a determined StO 2 value is achieved seems to minimize interindividual variations, thus homogenizing ReO 2 values for their comparison.”
BackgroundInfluentialSelf-citationDonati, A., Damiani, E., Luchetti, M. M., Domizi, R., Scorcella, C., Carsetti, A., Gabbanelli, V., Carletti, P., Bencivenga, R., Vink, H., et al. (2014) · Critical Care · doi:10.1186/cc13730 · Cited by 75
“StO2 was continuously recorded during the reperfusion phase until stabilization [33].”
BackgroundMethodInfluentialSelf-citationPlasma Free Hemoglobin and Microcirculatory Response to Fresh or Old Blood Transfusions in Sepsis
Damiani, E., Adrario, E., Luchetti, M. M., Scorcella, C., Carsetti, A., Mininno, N., Pierantozzi, S., Principi, T., Strovegli, D., Bencivenga, R., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0122655 · Cited by 69
“StO2 upslope and the area under the curve (AUC) StO2 reflect microvascular reactivity [32].”
BackgroundMethodSelf-citationFutier, E., Christophe, S., Robin, E., Petit, A., Pereira, B., Desbordes, J., Bazin, J.-É., & Vallet, B. (2011) · Critical Care · doi:10.1186/cc10449 · Cited by 76
“We used a fixed StO2 target of 40%, as recommended by other investigators [32,33], and found that the baseline StO2 recovery slopes were very close to those previously reported in healthy volunteers [15,33].”
MethodDonati, A., Damiani, E., Domizi, R., Scorcella, C., Carsetti, A., Tondi, S., Monaldi, V., Adrario, E., Romano, R., Pelaia, P., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1500-5 · Cited by 65
“The cuff was kept inflated until StO2 decreased to 40 % and was then released [13].”
MethodKagaya, Y., Ohura, N., Suga, H., Eto, H., Takushima, A., & Harii, K. (2013) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2013.11.011 · Cited by 66
Recent advances in bedside microcirculation assessment in critically ill patients
Tafner, P. F. D. A., Chen, F. K., Filho, R. R., Corrêa, T. D., Chaves, R. C. D. F., & Neto, A. S. (2017) · Revista Brasileira de Terapia Intensiva · doi:10.5935/0103-507x.20170033 · Cited by 62
“(61-64) During this reactive hyperemia, StO2 can reach higher levels than baseline StO2, indicating post-ischemic vasodilation and capillary recruitment.(61-64) The main limitations of this method include the fact that NIRS does not directly assess microcirculatory flow and globally checks a combination of arterioles,…”
BackgroundPetyaev, I. M., Dovgalevsky, P. Y., Klochkov, V. A., Chalyk, N. E., & Kyle, N. H. (2012) · The Scientific World JOURNAL · doi:10.1100/2012/269476 · Cited by 56
“The concentration of the end products such as malonic dialdehyde (MDA), and other possible thiobarbituric acid reactive substances, TBARS, was then measured by colorimetric methods [26] using reagents and kits from Cayman Chemical (MC, USA).”
MethodPrognostic implications of tissue oxygen saturation in human septic shock
Mesquida, J., Espinal, C., Gruartmoner, G., Masip, J., Sabatier, C., Baigorri, F., Pinsky, M. R., & Artigas, A. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2491-6 · Cited by 53
Self-citationKanick, S. C., Schneider, P. A., Klitzman, B. M., Wisniewski, N. A., & Rebrin, K. (2019) · Microvascular Research · doi:10.1016/j.mvr.2019.02.002 · Cited by 52
Hemodynamic Monitoring in Sepsis—A Conceptual Framework of Macro- and Microcirculatory Alterations
Văleanu, L., Bubenek-Turconi, Ş.-I., Ginghină, C., & Balan, C. I. (2021) · Diagnostics · doi:10.3390/diagnostics11091559 · Cited by 68
“It first generates a de-oxygenation slope (DeO2) that correlates with local VO2 and, following occlusion release, a re-oxygenation slope (ReO2) that depends tightly on capillary reactivity, a marker of endothelial integrity [118].”
BackgroundHarms, F. A., Voorbeijtel, W. J., Bodmer, S. I. A., Raat, N. J. H., & Mik, E. G. (2012) · Mitochondrion · doi:10.1016/j.mito.2012.10.005 · Cited by 47
Petyaev, I. M., Dovgalevsky, P. Y., Klochkov, V. A., Chalyk, N. E., Pristensky, D. V., Chernyshova, M. P., Udumyan, R., Kocharyan, T., Kyle, N. H., Lozbiakova, M. V., et al. (2018) · Food Science & Nutrition · doi:10.1002/fsn3.734 · Cited by 41
Mesquida, J., Caballer, A., Cortese, L., Vilà-Vilardel, C., Karadeniz, U., Pagliazzi, M., Zanoletti, M., Pacheco, A. P., Castro, P., García-de-Acilu, M., et al. (2021) · Critical Care · doi:10.1186/s13054-021-03803-2 · Cited by 43
“The VOT was performed as previously described [10, 14, 15].”
MethodSelf-citationMicrovascular reactivity and clinical outcomes in cardiac surgery
Kim, T. K., Cho, Y. J., Min, J. J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Critical Care · doi:10.1186/s13054-015-1025-3 · Cited by 42
“Second, the VOT itself has not been standardized with regard to the site of measurement, ischemic threshold, or time interval between tests [30].”
Measuring reactive hyperemia in the lower limb using near-infrared spectroscopy
Willingham, T. B., Southern, W. M., & McCully, K. K. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091302 · Cited by 45
Domizi, R., Damiani, E., Scorcella, C., Carsetti, A., Castagnani, R., Vannicola, S., Bolognini, S., Gabbanelli, V., Pantanetti, S., & Donati, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0213085 · Cited by 37
Donati, A., Damiani, E., Zuccari, S., Domizi, R., Scorcella, C., Girardis, M., Giulietti, A., Vignini, A., Adrario, E., Romano, R., et al. (2017) · BMC Anesthesiology · doi:10.1186/s12871-017-0342-2 · Cited by 37
“consumption, while the StO2 upslope (%/minute) and the area under the curve (AUC) of the hyperemic response were obtained to assess microvascular reactivity [20].”
Bernet, C., Desebbe, O., Bordon, S., Lacroix, C., Rosamel, P., Farhat, F., Lehot, J.-J., & Cannesson, M. P. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9301-5 · Cited by 32
Mesquida, J., Gruartmoner, G., Martínez, M. L., Masip, J., Sabatier, C., Espinal, C., Artigas, A., & Baigorri, F. (2010) · Shock · doi:10.1097/shk.0b013e3182094ab9 · Cited by 28
Self-citationMicrocirculatory monitoring in septic patients: Where do we stand?
Gruartmoner, G., Mesquida, J., & İnce, C. (2017) · Medicina Intensiva · doi:10.1016/j.medin.2016.11.011 · Cited by 27
“Whether one strategy or the other offers better results will be part of future clinical research.”
Self-citationLoggi, S., Mininno, N., Damiani, E., Marini, B., Adrario, E., Scorcella, C., Domizi, R., Carsetti, A., Pantanetti, S., Pagliariccio, G., et al. (2019) · BMC Anesthesiology · doi:10.1186/s12871-018-0673-7 · Cited by 26
Cortese, L., Zanoletti, M., Karadeniz, U., Pagliazzi, M., Yaqub, M. A., Busch, D. R., Mesquida, J., & Durduran, T. (2021) · Sensors · doi:10.3390/s21216957 · Cited by 26
“In addition, the VOT protocol adopted could influence the variability of the retrieved parameters: as discussed in previous studies, maintaining the ischemia up to a pre-determined minimum value of TSI (ischemia-depth-based protocol) should reduce the variations with respect to maintaining the ischemia for a fixed tim…”
BackgroundMethodSelf-citationConrad, M., Perez, P., Thivilier, C., & Lévy, B. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.03.029 · Cited by 23
“Limitations of the study The VOT procedure should be standardized; currently, various types and degrees of deflation thresholds (StO2 of 40% or 50%; duration of 35 minutes) are used [13,15,16].”
MethodLee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9595-1 · Cited by 20
Self-citationNear-infrared spectroscopy of the thenar eminence: comparison of dynamic testing protocols
Lipcsey, M., Eastwood, G. M., Woinarski, N. C. Z., & Bellomo, R. (2012) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01588-0 · Cited by 20
Butler, E., Chin, M., & Åneman, A. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.07.035 · Cited by 20
Transfusion Decision Making in Pediatric Critical Illness
Markham, C. M., Small, S., Hovmand, P. S., & Doctor, A. (2017) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2017.06.003 · Cited by 18
Rodríguez, A. H., Claverías, L., Marín‐Corral, J., Magret, M., Rosich, S., Bodí, M. A., Trefler, S., Pascual-Guàrdia, S., & Gea, J. (2014) · Medicina Intensiva · doi:10.1016/j.medin.2013.12.004 · Cited by 17
Podbregar, M., Gavrić, A. U., Podbregar, E., Možina, H., & Stefanovic, S. (2016) · Radiology and Oncology · doi:10.1515/raon-2015-0046 · Cited by 16
Kim, T. K., Nam, K., Cho, Y. J., Min, J. J., Hong, Y. J., Park, K. U., Hong, D. M., & Jeon, Y. (2016) · Anaesthesia · doi:10.1111/anae.13642 · Cited by 20
“to the site of measurement, ischaemic threshold, probe size and time interval between tests [35].”
BackgroundMasip, J., Mesquida, J., Luengo, C., Gili, G., Gomà, G., Ferrer, R., Teboul, J., Payen, D. M., & Artigas, A. (2013) · Annals of Intensive Care · doi:10.1186/2110-5820-3-30 · Cited by 16
Self-citationHendrick, E. S., Jamieson, A., Chiesa, S. T., Hughes, A. D., & Jones, S. H. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1480720 · Cited by 20
Mesquida, J., Espinal, C., Saludes, P., Cortés, E., Pérez-Madrigal, A., & Gruartmoner, G. (2019) · Journal of Critical Care · doi:10.1016/j.jcrc.2019.06.013 · Cited by 15
Self-citationJones, N., & Terblanche, M. (2010) · Critical Care · doi:10.1186/cc8970 · Cited by 14
Luengo, C., Resche‐Rigon, M., Damoisel, C., Kerever, S., Créteur, J., & Payen, D. M. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9400-y · Cited by 15
“Since most of the previously published data using the Hutchinson device have been obtained with a 325 model linked to a 25 mm probe spacing [13, 23, 24, 26], we compared the values obtained with model 650 linked to 15 mm probe to that set up.”
MethodWang, C., Chuang, M., Liang, S., Tsai, J.-C., Chuang, C., Hsieh, Y., Lu, C.-W., Lee, P., & Sun, C. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2147315 · Cited by 14
Claverías, L., Marí, M., Marín‐Corral, J., Magret, M., Trefler, S., Bodí, M. A., García‐España, A., Yébenes, J. C., Pascual-Guàrdia, S., Gea, J., et al. (2016) · Journal of Intensive Care · doi:10.1186/s40560-016-0129-4 · Cited by 13
Effective CPR Procedure With Real Time Evaluation and Feedback Using Smartphones
Gupta, N. K., Dantu, V., & Dantu, R. (2014) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2014.2327612 · Cited by 12
“Occlusion is used in many studies to measure transient oxygen saturation [34]–[36].”
MethodKyle, B., Litton, E., & Ho, K. M. (2012) · Anaesthesia · doi:10.1111/j.1365-2044.2012.07265.x · Cited by 12
“Despite these preliminary data, agreement on the normal value of StO2 in healthy individuals [12], and the optimal StO2 value that should be used to guide resuscitation in pathological states such as severe sepsis, remain uncertain [13–15].”
BackgroundVranken, N. P. A., Ganushchak, Y. M., Willigers, H. M., Maessen, J. G., & Weerwind, P. W. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.03.003 · Cited by 12
Engbers, S., Boysen, S. R., Engbers, J. D. T., & Chalhoub, S. (2014) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12229 · Cited by 12
Tissue microcirculation measured by vascular occlusion test during anesthesia induction
Kim, T. K., Cho, Y. J., Min, J. J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9679-6 · Cited by 11
Evaluating tissue oxygenation at the bedside: global, regional, or both?
Mesquida, J. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9690-y · Cited by 8
Self-citationZdravković, M., Podbregar, M., & Kamenik, M. (2019) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-019-00406-9 · Cited by 9
A systematic review of human and veterinary applications of noninvasive tissue oxygen monitoring
Salcedo, M. C., Tart, K. M., & Hall, K. E. (2016) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/vec.12465 · Cited by 11
“No adverse events were reported concerning the measurement of StO2.”
BackgroundInfluentialHaertel, F., Reisberg, D., Peters, M., Nuding, S., Schroeder, J., Werdan, K., & Ebelt, H. (2018) · Shock · doi:10.1097/shk.0000000000001225 · Cited by 8
Saturación tisular de oxígeno en el paciente crítico
Gruartmoner, G., Mesquida, J., & Baigorri, F. (2013) · Medicina Intensiva · doi:10.1016/j.medin.2013.07.004 · Cited by 7
“…un parámetro de consumo local de oxígeno a nivel de la musculatura tenar calculable a partir de la ecuación propuesta por Skarda et al. 10 : − 1 11,12 tor-niquete) en el antebrazo, y se realiza una oclusión a una presión 40 mmHg por encima de la presión arterial sistólica hasta conseguir una…”
Self-citationContinuous Cerebral and Tissue Oximetry by Three-Wave NIRS Device
Buyanov, D., & Zabodaev, S. V. (2020) · IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering · doi:10.1109/eiconrus49466.2020.9039540 · Cited by 6
“From here follow such parameters as the rate of deoxygenation (DeO2), which reflects the local metabolic rate, and the rate of reoxygenation (ReO2), which reflects the time required for leaching of stagnant blood [8].”
BackgroundCusack, R. A. F., Rodríguez, A. H., Cantan, B., Miskolci, O., Connolly, E. M., Zilahi, G., Coakley, J. D., & Martín‐Loeches, I. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14144982 · Cited by 6
Assessing stability and accuracy of a novel commercial wearable near-infrared spectroscopy device
de Moreira, I. D. M., Willigenburg, T. R., Kregting, W. J. W., Steijn, E. R. C. V., Floor, M., & Colier, W. N. J. M. (2023) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.2657434 · Cited by 8
“These results are not surprising, since other studies have shown that protocols that pre-determine a minimum value of SmO2 have been shown to reduce the variations between measurements [28].”
ResultBiedrzycka, A., Kowalik, M. M., Pawlaczyk, R., Jagielak, D., Świetlik, D., Szymanowicz, W., & Lango, R. (2016) · Interactive Cardiovascular and Thoracic Surgery · doi:10.1093/icvts/ivw232 · Cited by 5
Bouchet, J. B., Durand, E., Morel, J., Castelain, C., Fuzellier, J.-F., Molliex, S. B., & Auboyer, C. (2011) · Annales Françaises d Anesthésie et de Réanimation · doi:10.1016/j.annfar.2011.04.008 · Cited by 5
Isoproterenol infusion and microcirculation in septic shock.
Wiramus, S., Textoris, J., Bardin, R., Vigne, C., Kelway, C., Martin, C. M. P., & Léone, M. (2014) · Europe PMC (PubMed Central) · Cited by 4
Borrat, X., Mercadal, J., & Zavala, E. (2010) · Revista Española de Anestesiología y Reanimación · doi:10.1016/s0034-9356(10)70249-8 · Cited by 4
Effects of high oxygen tension on healthy volunteer microcirculation
Pôle de réanimation, H. R. S., Cousin, N., Goutay, J., Pôle de réanimation, H. R. S., Girardie, P., Pôle de réanimation, H. R. S., Favory, R., Pôle de réanimation, H. R. S., Drumez, É., Unité de méthodologie – biostatistique et data management, C. L., et al. (2022) · Diving and Hyperbaric Medicine Journal · doi:10.28920/dhm52.4.260-270 · Cited by 3
Vascular occlusion tests: Do we need another definition?
Mayeur, C., & Teboul, J. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182326456 · Cited by 3
Petyaev, I. M., Dovgalevsky, P. Y., Chalyk, N. E., Klochkov, V. A., & Kyle, N. H. (2016) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20160282 · Cited by 3
“The concentration of the end products such as malonic dialdehyde (MDA) and other possible thiobarbituric acid reactive substances (TBARS) were then measured with colorimetric methods (12) using reagents and kits from Cayman Chemical (MC, USA).”
MethodDomizi, R., Carsetti, A., Antolini, R., Casarotta, E., Scorcella, C., Zuccari, S., Vitali, E., Adrario, E., Donati, A., & Damiani, E. (2026) · Microvascular Research · doi:10.1016/j.mvr.2026.104924 · Cited by 2
Agarwal, R., Chaudhry, B., Jansen, K., O’Sullivan, J. J., Hudson, M., Allen, J., & Coats, L. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab1f1c · Cited by 2
Evaluation for occult sepsis incorporating NIRS and emergency sonography
Ng, N. Y. Y., Ang, H. H. E., Tan, J. C. L., Ho, W. H., Kuan, W. S., & Chua, M. T. (2018) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2018.02.020 · Cited by 2
“In addition to measuring absolute StO2 values, the inclusion of the vascular occlusion test (VOT) could improve the discriminatory function between normal and abnormal microcirculatory states [13-15].”
BackgroundMicrocirculatory monitoring in septic patients: Where do we stand?
Gruartmoner, G., Mesquida, J., & İnce, C. (2017) · Medicina Intensiva (English Edition) · doi:10.1016/j.medine.2017.02.007 · Cited by 2
Self-citationEvaluation of the Microcirculation in Critically Ill Patients
Damiani, E., Domizi, R., Scorcella, C., Carsetti, A., & Donati, A. (2020) · Springer eBooks · doi:10.1007/978-3-030-33832-9_25 · Cited by 1
Zanoletti, M., Yaqub, M. A., Cortese, L., Buttafava, M., García, J. M., Amendola, C., Carteano, T., Frabasile, L., García, D. S., Guadagno, C. N., et al. (2025) · Journal of Biomedical Optics · doi:10.1117/1.jbo.30.11.115004 · Cited by 3
“33,47,53,76,80,129,133,142,143 These considerations stress the need of a standardized way of measuring the microcirculation in the healthy and ICU population.”
Self-citationNear infrared spectroscopy assessment of wrist-based vascular occlusion protocols
Dvekar, V., Sadrzadeh-Afsharazar, F., DeVos, L., Saiko, G., & Douplik, A. (2025) · Advanced Optical Technologies · doi:10.3389/aot.2025.1707828 · Cited by 1
Haertel, F., Reisberg, D., Peters, M., Nuding, S., Schulze, P. C., Werdan, K., & Ebelt, H. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11051420 · Cited by 1
“NIRS is an established and reproducible method that allows the continuous monitoring of StO2 in real time, and two conditions for measuring StO2 have been established: measurements are taken under resting conditions (unprovoked), and using a ischemia–reperfusion test (vascular occlusion test (VOT)) [10,11].”
MethodRodríguez, A., Claverías, L., Marín‐Corral, J., Magret, M., Rosich, S., Bodí, M. A., Trefler, S., Pascual-Guàrdia, S., & Gea, J. (2015) · Medicina Intensiva (English Edition) · doi:10.1016/j.medine.2013.12.004 · Cited by 4
Grotowska, M., & Goździk, W. (2023) · Journal of International Medical Research · doi:10.1177/03000605231209820 · Cited by 1
“36 The present study had some limitations.”
Non-invasive monitoring and cardiac arrest: a cautious attempt to view beyond the curtain (skin)
Teschendorf, P. (2012) · Resuscitation · doi:10.1016/j.resuscitation.2012.05.003 · Cited by 1
Use of Non-invasive Tissue Oxygen Saturation Monitoring to Assess Cardiovascular Insufficiency
García, X., Guyette, F. X., & Pinsky, M. R. (2011) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-642-18081-1_34
Self-citationNoninvasive Monitoring of Peripheral Perfusion in Critically Ill Patients
Lima, A. A. P. (2013) · RePub (Erasmus University Rotterdam) · Cited by 2
Implicacions pronòstiques de la saturació tissular d'oxigen en pacients amb xoc sèptic.
Espinal, C., & Artigas, A. (2012) · Dipòsit Digital de Documents de la UAB (Universitat Autònoma de Barcelona)
Non-invasive tissue oximetry: current and prospective applications
Vranken (2017) · Research Publications (Maastricht University) · doi:10.26481/dis.20171218nv
Zheng, Y., Guo, F., Lu, B., & Li, Q. (2019) · Critical Care · doi:10.1186/s13054-019-2412-y
Tam, E., Bruseghini, P., Capelli, C., Baraldo, M., Chiamulera, C., & Zandonai, T. (2020) · Vascular Medicine · doi:10.1177/1358863x20906029 · Cited by 1
Cheng, K.-M., Zhang, L., Sun, X.-M., & Duan, Y. (2021) · Springer eBooks · doi:10.1007/978-981-15-9770-1_1
Liu, Z., Lin, H., Li, M., Pang, G., Xie, Z., & Huang, Z. (2025) · BMC Cardiovascular Disorders · doi:10.1186/s12872-025-04622-x
“StO 2 and vascular occlusion testing can identify tissue hypoperfusion in trauma and sepsis [31].”
Mesquida, J., Caballer, A., Cortese, L., Vila, C., Karadeniz, U., Pagliazzi, M., Zanoletti, M., Pacheco, A. P., Castro, P., García-de-Acilu, M., et al. (2021) · Figshare · doi:10.6084/m9.figshare.16960436
Self-citationAdditional file 1 of Microvascular reactivity and clinical outcomes in cardiac surgery
Kim, T. K., Cho, Y. J., Min, J. J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Figshare · doi:10.6084/m9.figshare.4436564
Additional file 3 of Microvascular reactivity and clinical outcomes in cardiac surgery
Kim, T. K., Cho, Y. J., Min, J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Figshare · doi:10.6084/m9.figshare.4436573
Additional file 5 of Microvascular reactivity and clinical outcomes in cardiac surgery
Kim, T. K., Cho, Y. J., Min, J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Figshare · doi:10.6084/m9.figshare.4436570
Additional file 2 of Microvascular reactivity and clinical outcomes in cardiac surgery
Kim, T. K., Cho, Y. J., Min, J., Murkin, J. M., Bahk, J.-H., Hong, D. M., & Jeon, Y. (2015) · Figshare · doi:10.6084/m9.figshare.4436567
Mallat, J. (2022) · theses.fr (ABES) · doi:10.70675/284fd77dz7652z47d0zb28fz021e96acbf23
Şavluk, Ö. F., Yılmaz, A. A., Tomrukçu, F., Yavuz, Y., Işıldak, F. U., Genç, F. A., Arıcı, Ş., Karakuş, Ö. S., Corbacioglu, S., Gürcü, M. E., et al. (2026) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2026.05.001
Metadata
- Authors
- Gómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R.
- Affiliations
- University of Pittsburgh (US)
- Universitat Autònoma de Barcelona (ES)
- Corresponding author
- Pinsky, Michael R
- Venue
- Critical Care
- Published
- 2009-11-30
- Volume
- 13
- Issue
- S5
- Pages
- S3-S3
- ISSN
- 1364-8535 (ISSN-L)
- PMC
- PMC2786105
- OpenAlex
- W1967705433
- Semantic Scholar
- 73960e7e00fbf26d07e99ff69b5c353dbacbf50d
- Cited by
- 94
- References
- 14
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 5 · 2020: 3 · 2019: 11 · 2018: 4 · 2017: 6 · 2016: 12 · 2015: 10 · 2014: 6 · 2013: 5 · 2012: 9
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Critical Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion)
- D-Scholarship@Pitt (University of Pittsburgh) (acceptedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Funders
- University of Pittsburgh
- National Heart, Lung, and Blood Institute (R01HL076157, HL76157, HL 67181, K24HL067181, T32HL007820)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- tissue oxygen saturation, vascular occlusion test, tissue hypoperfusion, measurement site, thenar eminence, forearm, probe size, trauma (physical injury), sepsis, hyperemia, deoxygenation rate, standardized monitoring protocols, measurement reproducibility
- MeSH terms
- Adolescent, Adult, Female, Forearm, Humans, Male, Oxygen Consumption, Vascular Diseases, Muscle, Skeletal, Spectroscopy, Near-Infrared, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.