Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Introduction: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to frequency and conditions surrounding hypoglycemic events. Methods: This is a retrospective analysis of adult patients with hyperglycemia receiving intravenous (IV) insulin therapy from March 2006 to December 2007 in the intensive care units of 2 tertiary care teaching hospitals. Patients placed on a glycemic control protocol using the Clarian GlucoStabilizer™ IV insulin dosing calculator with a target range of 4.4-6.1 mmol/L were analyzed. Metrics included time to target, time in target, mean blood glucose ± standard deviation, % measures in hypoglycemic ranges <3.9 mmol/L, per-patient hypoglycemia, and BG testing interval. Results: 4,588 ICU patients were treated with the GlucoStabilizer to a BG target range of 4.4-6.1 mmol/L. We observed 254 severe hypoglycemia episodes (BG <2.2 mmol/L) in 195 patients, representing 0.1% of all measurements, and in 4.25% of patients or 0.6 episodes per 1000 hours on insulin infusion. The most common contributing cause for hypoglycemia was measurement delay (n = 170, 66.9%). The median (interquartile range) time to achieve the target range was 5.9 (3.8 - 8.9) hours. Nearly all (97.5%) of patients achieved target and remained in target 73.4% of the time. The mean BG (± SD) after achieving target was 5.4 (± 0.52) mmol/L. Targeted blood glucose levels were achieved at similar rates with low incidence of severe hypoglycemia in patients with and without diabetes, sepsis, renal, and cardiovascular disease. Conclusions: Glycemic control to a lower glucose target range can be achieved using a computerized insulin dosing protocol. With particular attention to timely measurement and adjustment of insulin doses the risk of hypoglycemia experienced can be minimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Automated, computerized, IV insulin protocols, including commercially available or institutional-based protocols, have improved glycemic control, with good acceptance by nursing personnel.1294–1307”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1296]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977 · cited 2×
“The Leuven paperbased protocol [3], using a target range of 4.”
BackgroundMethodIntensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639 · cited 1×
“7% of the intervention group in the Leuven II medical ICU study experienced severe hypoglycemia, increasing to 25% among patients with ICU stays of 5 days or longer [11].”
BackgroundIntensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921
Authors/Task Force Members, Ryden, L., Standl, E., Bartnik, M., Van den Berghe, G., Betteridge, J., de Boer, M.-J., Cosentino, F., Jonsson, B., Laakso, M., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl260 · Cited by 1,647
Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult Patients
Krinsley, J. S. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.8.992 · Cited by 1,223 · cited 1×
“Observational studies outside of clinical trials supported these results, finding improved outcomes after intensive insulin therapy to manage hyperglycemia in the critically ill patient [ 4-6 ].”
ResultKrinsley, J. S. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.12.1471 · Cited by 1,165 · cited 1×
“Observational studies outside of clinical trials supported these results, finding improved outcomes after intensive insulin therapy to manage hyperglycemia in the critically ill patient [4-6].”
ResultFurnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130 · cited 2×
“Regarding other protocols, in a study of cardiac surgery patients with diabetes, 61% of patients achieved the glucose target range of 4.4 to 8.3 mmol/L while on continuous insulin infusion based on the Portland protocol (paper-based) with a 7.1% hypoglycemia rate (BG 2.2 mmol/L) [4].”
MethodResultInfluentialGriesdale, D. E. G., de Souza, R. J., van Dam, R. M., Heyland, D. K., Cook, D. J., Malhotra, A., Dhaliwal, R., Henderson, W. R., Chittock, D. R., Finfer, S., et al. (2009) · Canadian Medical Association Journal · doi:10.1503/cmaj.090206 · Cited by 1,096 · cited 4×
“This overarching concern for hypoglycemia has resulted in a call for more measured, less aggressive glycemic control [13-15], and higher target BG ranges (6.”
BackgroundResultInfluentialPreiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911 · cited 3×
“Several large randomized controlled trials were stopped due to unacceptably high rates of severe hypoglycemia (blood glucose (BG) 9 ] and 17.0% of the tight control group in the Efficacy of Volume Substitution and Insulin Therapy in Severe Sepsis (VISEP) study [10].”
BackgroundMethodResultInfluential
Research works printed but not linked: 1
- Krinsley JS, Grover A: Severe hypoglycemia in critically ill patients: risk factors and outcomes. Crit Care Med 2007, 35: 2262-2267. 10.1097/01.CCM.0000282073.98414.4B · DOI · Paper page
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
“This approach corrected the BG into the target range in 98% within 30 mins for patients who had received IV insulin infusions (95, 97).”
BackgroundMethodSelf-citationBlonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Krinsley, J. S., & Preiser, J.-C. (2015) · Critical Care · doi:10.1186/s13054-015-0908-7 · Cited by 174
“4% [35].”
Klonoff, D. C., Messler, J., Umpierrez, G. E., Peng, L., Booth, R., Crowe, J., Garrett, V., McFarland, R., & Pasquel, F. J. (2020) · Diabetes Care · doi:10.2337/dc20-1857 · Cited by 122
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“In addition, computerized systems allow reducing nurses and physicians work time, time to reach the targeted glycaemia and the onset of hypoand hyperglycaemia [172, 181].”
Yatabe, T., Yamazaki, R., Kitagawa, H., Okabayashi, T., Yamashita, K., Hanazaki, K., & Yokoyama, M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206b9ad · Cited by 73
“A previous study reported that delays of 12 mins in blood glucose measurements were important contributors to the incidence of hypoglycemic events in 67% of the patients (13).”
BackgroundInnovative Designs for the Smart ICU
Halpern, N. A. (2014) · CHEST Journal · doi:10.1378/chest.13-0004 · Cited by 72
Lanspa, M. J., Hirshberg, E. L., Phillips, G. D., Holmen, J. R., Stoddard, G. J., & Orme, J. F. (2012) · CHEST Journal · doi:10.1378/chest.12-2072 · Cited by 73
Lanspa, M. J., Krinsley, J. S., Hersh, A. M., Wilson, E. L., Holmen, J. R., Orme, J. F., Morris, A. H., & Hirshberg, E. L. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.05.016 · Cited by 73
Expert consensus on the glycemic management of critically ill patients
Wu, Z., Liu, J., Zhang, D., Kang, K., Zuo, X., Xu, Q., Pan, A., Fang, W., Liu, F., Shang, Y., et al. (2022) · Journal of Intensive Medicine · doi:10.1016/j.jointm.2022.06.001 · Cited by 73
A systematic scoping review on the consequences of stress-related hyperglycaemia
Olariu, E., Pooley, N., Danel, A., Miret, M., & Preiser, J. (2018) · PLoS ONE · doi:10.1371/journal.pone.0194952 · Cited by 68
Diabetes technology in the inpatient setting for management of hyperglycemia
Davis, G. M., Galindo, R. J., Migdal, A. L., & Umpierrez, G. E. (2020) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.11.002 · Cited by 62
Van Steen, S., Rijkenberg, S., Limpens, J., Van der Voort, P., Hermanides, J., & DeVries, J. (2017) · Sensors · doi:10.3390/s17010146 · Cited by 59
“In critically ill patients, between 4% and 15% of hypoglycemic events are undetected [24] and hypoglycemic episodes occur more frequently when there is a longer time interval between glucose measurements [25].”
Continuous Insulin Infusion: When, Where, and How?
Kelly, J. L. (2014) · Diabetes Spectrum · doi:10.2337/diaspect.27.3.218 · Cited by 60
Roldan, V. D. T., Urtecho, M., Nayfeh, T., Firwana, M., Muthusamy, K., Hasan, B., Abd‐Rabu, R., Maraboto, A., Qoubaitary, A., Prokop, L. J., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac601 · Cited by 47
Krinsley, J. S., Bruns, D. E., & Boyd, J. C. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814566507 · Cited by 41
“Notably, time in targeted BG range increased with the use of a computerized protocol compared to that achieved by the highly trained team using their nurse drive protocol glycemic control in the Leuven ICU(36) and the use of a computer driven insulin protocol has been demonstrated to markedly reduce hypoglycemia rates…”
MethodAloi, J., Bode, B. W., Ullal, J., Chidester, P., McFarland, R. S., Bedingfield, A. E., Mabrey, M., Booth, R., Mumpower, A., & Wallia, A. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816664746 · Cited by 39
Saur, N. M., Kongable, G. L., Holewinski, S., O’Brien, K., & Nasraway, S. A. (2013) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2013.07.003 · Cited by 37
“This pilot study used the GlucoStabilizer, which has previously been shown to be efficacious in achieving tight glycemic control(37) while also lessening hypoglycemia.(39) It has been postulated that targeting decreased variability will provide a survival advantage once attributed to euglycemia without the associated…”
Self-citationNair, B. G., Grunzweig, K. A., Peterson, G. N., Horibe, M., Neradilek, M. B., Newman, S.-F., Norman, G. A. V., Schwid, H. A., Hao, W., Hirsch, I. B., et al. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9718-3 · Cited by 38
Eslami, S., de Keizer, N. F., Dongelmans, D. A., de Jonge, E., Schultz, M. J., & Abu–Hanna, A. (2011) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2011.10.004 · Cited by 42
“Recent studies have shown that frequent and timely BGL measurements improved the quality and safety of blood glucose regulation [3] [4].”
BackgroundInnovative Designs for the Smart ICU
Halpern, N. A. (2014) · CHEST Journal · doi:10.1378/chest.13-0005 · Cited by 36
Mann, E. A., Jones, J. A., Wolf, S. E., & Wade, C. E. (2011) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e31820aaebf · Cited by 35
“Thus, regardless of the specific glucose range desired, computerized protocols continue to offer the potential for reduction of hypoglycemic episodes, 27,28 a potential for decreased glycemic variability, and standardization among providers and institutions.”
BackgroundPrice, C. E., Fanelli, J. E., Aloi, J., Anzola, S. C., Vishneski, S. R., Saha, A. K., Woody, C., & Segal, S. (2023) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2023.111090 · Cited by 32
Tanenberg, R. J., Hardee, S., Rothermel, C., & Drake, A. J. (2017) · Endocrine Practice · doi:10.4158/ep161402.or · Cited by 27
Glycemic targets in critically ill adults: A mini-review
See, K. C. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i10.1719 · Cited by 28
Bioinformatics assistance of metabolic and nutrition management in the ICU
Berger, M. M., & Que, Y. (2010) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e328341ed77 · Cited by 27
“In a large retrospective study including 4588 ICU patients treated with a computer-based ‘glucose stabilizer program’, Juneja et al. [19] reported hypoglycemia only in 0.1% of all measurements, the likeliest reason being early warning by the system.”
BackgroundMethodInfluentialKapoor, R., Timsina, L., Gupta, N., Kaur, H., Vidger, A. J., Pollander, A. M., Jacobi, J., Khare, S., & Rahman, O. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9113635 · Cited by 23
“Details of this program have been published previously, and it has been associated with high target achievement and low incidence of severe hypoglycemia [21].”
BackgroundSelf-citationNursing Perspectives on the Use of Continuous Glucose Monitoring in the Intensive Care Unit
Faulds, E. R., Dungan, K. M., McNett, M., JONES, L. G., Poindexter, N., Exline, M. C., Pattison, J., & Pasquel, F. J. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231170616 · Cited by 26
Ekanayake, P. S., Juang, P. S., & Kulasa, K. M. (2020) · Current Diabetes Reports · doi:10.1007/s11892-020-01364-2 · Cited by 21
Fitzgerald, O., Perez‐Concha, O., Gallego, B., Saxena, M. K., Rudd, L., Metke‐Jimenez, A., & Jorm, L. R. (2021) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocab060 · Cited by 27
“Indeed, unplanned feeding reduction or interruption may lead to hypoglycemia events.(27,28) Further, there is evidence that variation in blood glucose level (or associated metabolic states), independent of the target value, is associated with increased mortality.”
BackgroundMinnema, A. J., Mehta, A. I., Boling, W., Schwab, J. M., Simard, J. M., & Farhadi, H. F. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-031329 · Cited by 22
Khalaila, R., Libersky, E., Catz, D., Pomerantsev, E., Bayya, A., Linton, D. M., & Sviri, S. (2011) · Critical Care Nurse · doi:10.4037/ccn2011934 · Cited by 22
Amrein, K., Kachel, N., Fries, H., Hovorka, R., Pieber, T. R., Plank, J., Wenger, U., Lienhardt, B., & Maggiorini, M. (2014) · BMC Endocrine Disorders · doi:10.1186/1472-6823-14-62 · Cited by 28
“Computer-assisted GC may be able to overcome some of the difficulties encountered in daily routine and appears to be superior to standard care [16-21].”
BackgroundThe Future is Now: Software-Guided Intensive Insulin Therapy in the Critically Ill
Rattan, R., & Nasraway, S. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700231 · Cited by 22
Self-citationAutomated Near-Continuous Glucose Monitoring Measured in Plasma Using Mid-Infrared Spectroscopy
Jax, T. W., Heise, T., Nosek, L., Gable, J., Lim, G., & Calentine, C. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500222 · Cited by 20
Year in review 2009: Critical Care - metabolism
Huberlant, V., & Preiser, J. (2010) · Critical Care · doi:10.1186/cc9256 · Cited by 19
“In Critical Care, Juneja and colleagues [22] report their experience of the use of a computerized insulin IV protocol program in 4,588 patients over 21 months.”
BackgroundIncidence of Hypoglycemia with Tight Glycemic Control Protocols: A Comparative Study
Anabtawi, A., Hurst, M., Titi, M. A., Patel, S. R., Palacio, C., & Rajamani, K. K. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0009 · Cited by 16
“These results are concordant with those from the recent study by Juneja et al., 19 which advocated for a computerized insulin protocol that eliminated calculations and allowed prompt and accurate adjustment of insulin dose based on timely measurements of BG levels.”
Hersh, A. M., Hirshberg, E. L., Wilson, E. L., Orme, J. F., Morris, A. H., & Lanspa, M. J. (2018) · CHEST Journal · doi:10.1016/j.chest.2018.04.025 · Cited by 18
“Since the publication of NICE-SUGAR, updated IIT algorithms using computer protocols, improved insulin delivery methods, and continuous glucose monitoring systems have increased the ability to achieve low blood glucose (BG) targets with marked reduction in severe hypoglycemia.(20,21) Issues with the accuracy of earlie…”
Evaluating the implementation of the EndoTool glycemic control software system
John, S. M., Waters, K. L., & Jivani, K. (2018) · Diabetes Spectrum · doi:10.2337/ds16-0061 · Cited by 15
“In an efficacy study, use of EndoTool resulted in a 46% decrease in the total number of blood glucose measurements taken each month and an overall reduction in the total number of minutes spent by nurses dealing with glucose control issues (6).”
MethodResultInsulin Infusion Therapy in Critically Ill Patients
Boutin, J., & Gauthier, L. (2014) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2014.01.016 · Cited by 17
Krinsley, J. S., Bochicchio, K. M., Calentine, C., & Bochicchio, G. V. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600212 · Cited by 13
Clergeau, A., Parienti, J., Reznik, Y., Clergeau, D., Seguin, A., Valette, X., du Cheyron, D., & Joubert, M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0314 · Cited by 15
Hypoglycemia Prevention by Algorithm Design During Intravenous Insulin Infusion
Braithwaite, S. S., Clark, L., Idrees, T., Qureshi, F. M., & Soetan, O. T. (2018) · Current Diabetes Reports · doi:10.1007/s11892-018-0994-4 · Cited by 12
Dinglas, C., Muscat, J. C., Adams, T. M., Peragallo‐Dittko, V., Vintzileos, A. M., & Heo, H. J. (2018) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2018.05.003 · Cited by 11
Yatabe, T., Nakamura, R., Kitagawa, H., Munekage, M., & Hanazaki, K. (2015) · Journal of Artificial Organs · doi:10.1007/s10047-015-0855-8 · Cited by 11
Risk Management for Point-of-Care Testing.
Hn, J. (2014) · PubMed Central · Cited by 15
Adherence to a Hypoglycemia Protocol in Hospitalized Patients: A Retrospective Analysis
Tracy, M. F., Manchester, C. S., Mathiason, M. A., Wood, J., & Moore, A. L. (2020) · Nursing Research · doi:10.1097/nnr.0000000000000478 · Cited by 10
Individualizing Glycemic Control in the Critically Ill
Murphy, C. V., Saliba, L., MacDermott, J., Soe, K. K., & Dungan, K. M. (2019) · Critical Care Nursing Quarterly · doi:10.1097/cnq.0000000000000288 · Cited by 9
Outcomes and adverse effects of extremely high dose insulin infusions in ICU patients
Vidger, A. J., & Czosnowski, Q. A. (2021) · Journal of Critical Care · doi:10.1016/j.jcrc.2021.01.015 · Cited by 8
The benefits of tight glycemic control in critical illness: Sweeter than assumed?
Gardner, A. J. (2014) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.146315 · Cited by 10
“Modeling is becoming an increasingly important element of TGC studies in an attempt to effi ciently and safely achieve normoglycemia.[53,54] By controlling for the kinetics of glucose, and the endogenous production, clearance and absorption of insulin, modeling allows for more precise glucose control to be achieved.”
How to Prescribe Nutritional Support Using Computers
Berger, M. M. (2012) · World review of nutrition and dietetics · doi:10.1159/000341250 · Cited by 6
Decisional practices and patterns of intraoperative glucose management in an academic medical center
Grunzweig, K. A., Nair, B. G., Peterson, G. N., Horibe, M., Neradilek, M. B., Newman, S.-F., Norman, G. A. V., Schwid, H. A., Hao, W., Dellinger, E. P., et al. (2016) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2016.02.027 · Cited by 6
Telford, E. D., Franck, A. J., Hendrickson, A. L., & Maltese, N. (2018) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2017.10.005 · Cited by 8
Canbolat, Ö., Kapucu, S., & Kılıçkaya, O. (2019) · Critical Care Nurse · doi:10.4037/ccn2019431 · Cited by 7
Wong, A. F., Pielmeier, U., Haug, P. J., Andreassen, S., & Morris, A. H. (2015) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocv067 · Cited by 5
The Effectiveness of a Computerized IV Infusion Protocol to Treat Hyperglycemia in Burn Patients
Sood, R., Zieger, M., Roggy, D., Nazim, M., Henderson, S. R., & Hartman, B. (2011) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e318241b305 · Cited by 5
“13 Consequently, BG control can be suboptimal.”
Inpatient Insulin Dosing Calculators
Hansen, J. J., Bacani, G., Juang, P. S., & Kulasa, K. M. (2025) · Diabetes Spectrum · doi:10.2337/dsi25-0002 · Cited by 4
Tight glycemic control: what do we really know, and what should we expect?
Nasraway, S. A., & Rattan, R. (2010) · Critical Care · doi:10.1186/cc9236 · Cited by 4
Self-citationHarris, S. A., Nisly, S. A., Aykroyd, L., Carroll, J. C., Ulmer, B. J., Waddell, M., Flanders, S. J., & Juneja, R. (2013) · Advances in Diabetes and Metabolism · doi:10.13189/adm.2013.010106 · Cited by 4
“There is long standing glycemic control initiative in these institutions; the Systematic Utilization of Glucose Assessment and Response (SUGARTM) Program [11-13] with heightened awareness towards insulin treatment and aggressive monitoring of BG which could have influenced the results.”
BackgroundSelf-citationMurthy, M. S., Duby, J. J., Parker, P. L., Durbin-Johnson, B. P., Roach, D. M., & Louie, E. L. (2015) · Annals of Pharmacotherapy · doi:10.1177/1060028015585574 · Cited by 4
“Although this formula reportedly restored euglycemia, no evidence of the dose-response relationship was provided.(13) Our findings appear to substantiate this correction strategy.”
ResultPark, S. W., Lee, S., Cha, W. C., Hur, K. Y., Kim, J. H., Lee, M.-K., Park, S., & Jin, S. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2018.0227 · Cited by 4
Braithwaite, D. T., Umpierrez, G. E., & Braithwaite, S. S. (2014) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.5.1.23 · Cited by 3
“Hypoglycemia is a specific and well recognized risk of intravenous insulin infusion, reported to be associated with lower glycemic targets, and potentially attributed to presence of renal failure, use of higher amounts of insulin, design of protocols specifying continuation of insulin despite low glucose readings < 10…”
BackgroundPatek, S. D., Ortiz, E. A., Farhy, L. S., Mason, J. E., Isbell, J. M., Kirby, J. L., & McCall, A. L. (2015) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.1109/acc.2015.7172132 · Cited by 2
“some computerized insulin protocols are now commercially available [48], [49], it is still a challenge to configure these”
Glucose Meter Use in the Intensive Care Unit: Much Ado About Something.
Sk, B. (2014) · PubMed Central · Cited by 3
Diabetisches Koma und perioperative Diabetestherapie
Berndt, M., Klose, S., & Lehnert, H. (2014) · Springer eBooks · doi:10.1007/978-3-642-54953-3_67 · Cited by 2
Oud, L., & Spellman, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813518136 · Cited by 2
“1) Ethnicity, n (%) White 186 (53) Hispanic 150 (43) Black 14 (4) Other 1 Comorbid conditions, n (%) Diabetes mellitus 202 (58) Hypertension 212 (60) Congestive heart failure 33 (9) Coronary artery disease 116 (33) Chronic kidney disease 34 (10) Chronic obstructive pulmonary disease 58 (17) Type of ICU admission, n (%…”
BackgroundDiabetisches Koma und perioperative Diabetestherapie
Klose, S., & Lehnert, H. (2004) · Springer eBooks · doi:10.1007/978-3-662-06654-6_51 · Cited by 1
Automating Blood Glucose Control
Yatabe, T., Hanazaki, K., & Yokoyama, M. (2012) · Journal of Anesthesia & Clinical Research · doi:10.4172/2155-6148.1000186 · Cited by 1
“Researchers have questioned whether truly continuous glucose monitoring is necessary, but reports have suggested that delays of even 12 minutes in glucose measurement are a factor in hypoglycemia [22].”
BackgroundSafe Implementation of a Hyperglycemic Crises Protocol by Utilizing a Conversion Table
Murray-Bachmann, R., O’Flaherty, D., Lewis-Holman, S., Patterson, S. M., Ashman, S., & Macyk, I. (2018) · Sigma's 29th International Nursing Research Congress · Cited by 1
Penning, S. (2014) · ORBi (University of Liège) · Cited by 1
Hoekstra, M., Vogelzang, M., Verbitskiy, E. A., & Nijsten, M. W. (2010) · Critical Care · doi:10.1186/cc8190 · Cited by 1
“In the recently published work of Juneja and colleagues the authors describe the excellent results of a com puterized insulin dosing algorithm (Clarian GlucoStabilizer™) [ 1 ].”
Glucose: the worst of all evils?
Prins, A. (2010) · South African Journal of Clinical Nutrition · doi:10.1080/16070658.2010.11734271
“The incidence of hypoglycaemia in tight control groups varied from 7–20% and was as low as 0.5% in control groups in ICU-based studies (Table II).23 Juneja et al (2009) found that the most common contributing cause for hypoglycaemia was measurement delay.8 It is known that severe hypoglycaemia…”
BackgroundInfluentialSurvey about diffusion and adoption of glycaemic controller in European intensive care units
Penning, S., Pironet, A., Chase, J. G., Pretty, C. G., & Desaive, T. (2014) · IFAC Proceedings Volumes · doi:10.3182/20140824-6-za-1003.01949
“We can cite the following GC systems: Glucommander (Davidson et al., 2005, Davidson et al., 2008), Clarian GlucoStabilizer (Juneja et al., 2009), GRIP (Vogelzang et al., 2005, Vogelzang et al., 2008), eMPC (Amrein et al., 2012, Pachler et al., 2008), Glucosafe (Pielmeier et al., 2010, Pielmeier et…”
MethodInfluentialThe Impact of Insulin and Insulin Therapy on Physiology in Critical Illness
Suhaimi, F. M. (2012) · UC Research Repository (University of Canterbury) · doi:10.26021/1869
A Tale of 2 Studies: How 2 Clinical Trials Changed the Use of Glucose Meters in Healthcare
Karon, B. S. (2014) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000027
Karon, B. S. (2016) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/poc.0000000000000096
Glucose management in the intensive care unit: are we looking for the right sweet spot?
Beesley, S. J., Hirshberg, E. L., & Lanspa, M. J. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.08.30
“The largest trial of intensive insulin therapy had high rates of clinician error contributing to hypoglycemia (10).”
BackgroundStamping out hypoglycemia in a surgical Intensive Care Unit: A multidisciplinary approach
Gerlach, A. T., MacDermott, J., Newton, C. L., Cook, C. H., & Murphy, C. V. (2016) · International Journal of Academic Medicine · doi:10.4103/2455-5568.196866
Surveillance et évaluation de l’efficacité de la nutrition artificielle en réanimation
Thibault, R., & Tamion, F. (2013) · Réanimation · doi:10.1007/s13546-013-0707-6
“Les systèmes informatiques permettent de réduire le temps infirmier et médical, raccourcir le temps nécessaire pour atteindre l’objectif glycémique et la survenue d’hypo- et hyperglycémies [20,28].”
BackgroundGranadeiro, R. M. D. A., Sá, S. P. C., Granadeiro, D. D. S., Passos, J. P., dos Santos, F. B., & dos Santos, M. E. R. (2020) · Revista de Pesquisa Cuidado é Fundamental Online · doi:10.9789/2175-5361.rpcfo.v12.7923
Diabetisches Koma und perioperative Diabetestherapie
Berndt, M., Klose, S., & Lehnert, H. (2015) · Springer eBooks · doi:10.1007/978-3-642-54675-4_78-1
Faulds, E. R., Lee, B., Rasul, A., JONES, L. G., McNett, M., Exline, M. C., Shoben, A. B., Lin, C. J., Madan, R., & Dungan, K. M. (2024) · Research Square · doi:10.21203/rs.3.rs-4243392/v1
Krinsley, J. S., & Preiser, J.-C. (2021) · Figshare · doi:10.6084/m9.figshare.15094885
Janowski, A., Patel, N., Ware, L. R., Dube, K. M., Kovacevic, M. P., Lupi, K. E., Tom, A., Roberts, R. J., Bane, A., Szumita, P. M., et al. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261462502
Lalani, B., Penno, R., Bay, R. C., & Lalani, A. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261467050
Comparison of computer and paper-based protocols for managing hyperglycemia in critical ill patients
Peckham, A. T. (2015) · doi:10.6083/m46m35kq · Cited by 1
Metadata
- Authors
- Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J.
- Affiliations
- Indiana University Indianapolis (US)
- Indiana University Health (US)
- Tufts University (US)
- The Epsilon Group (US)
- Corewell Health William Beaumont University Hospital (US)
- Corresponding author
- Juneja, Rattan
- Venue
- Critical Care
- Published
- 2009-10-12
- Volume
- 13
- Issue
- 5
- Pages
- R163-R163
- ISSN
- 1364-8535 (ISSN-L)
- PMC
- PMC2784393
- OpenAlex
- W2034805451
- Cited by
- 86
- References
- 43
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 6 · 2015: 9 · 2014: 14 · 2013: 4 · 2012: 7
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0/ (tdm)
- creativecommons.org/licenses/by/2.0/ (vor)
- Locations
- Critical Care (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- IUScholarWorks (Indiana University) (submittedVersion, cc-by)
- Funders
- Vlaamse regering
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- hypoglycemia, glycemic control, hyperglycemia, critically ill patients, intensive insulin therapy, diabetes mellitus, sepsis, kidney disease, cardiovascular disease
- MeSH terms
- Adult, Algorithms, Blood Glucose, Drug Therapy, Computer-Assisted, Humans, Hypoglycemia, Infusions, Intravenous, Insulin, Intensive Care Units, Retrospective Studies, Time Factors, Glycemic Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.