Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Introduction: Control of blood glucose (BG) in critically ill patients is considered important, but is difficult to achieve, and often associated with increased risk of hypoglycemia. We examined the use of a computerized insulin dosing algorithm to manage hyperglycemia with particular attention to frequency and conditions surrounding hypoglycemic events. Methods: This is a retrospective analysis of adult patients with hyperglycemia receiving intravenous (IV) insulin therapy from March 2006 to December 2007 in the intensive care units of 2 tertiary care teaching hospitals. Patients placed on a glycemic control protocol using the Clarian GlucoStabilizer™ IV insulin dosing calculator with a target range of 4.4-6.1 mmol/L were analyzed. Metrics included time to target, time in target, mean blood glucose ± standard deviation, % measures in hypoglycemic ranges <3.9 mmol/L, per-patient hypoglycemia, and BG testing interval. Results: 4,588 ICU patients were treated with the GlucoStabilizer to a BG target range of 4.4-6.1 mmol/L. We observed 254 severe hypoglycemia episodes (BG <2.2 mmol/L) in 195 patients, representing 0.1% of all measurements, and in 4.25% of patients or 0.6 episodes per 1000 hours on insulin infusion. The most common contributing cause for hypoglycemia was measurement delay (n = 170, 66.9%). The median (interquartile range) time to achieve the target range was 5.9 (3.8 - 8.9) hours. Nearly all (97.5%) of patients achieved target and remained in target 73.4% of the time. The mean BG (± SD) after achieving target was 5.4 (± 0.52) mmol/L. Targeted blood glucose levels were achieved at similar rates with low incidence of severe hypoglycemia in patients with and without diabetes, sepsis, renal, and cardiovascular disease. Conclusions: Glycemic control to a lower glucose target range can be achieved using a computerized insulin dosing protocol. With particular attention to timely measurement and adjustment of insulin doses the risk of hypoglycemia experienced can be minimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Automated, computerized, IV insulin protocols, including commercially available or institutional-based protocols, have improved glycemic control, with good acceptance by nursing personnel.1294–1307”
From American Association of Clinical Endocrinology Clinical Practice Guideline: Developing a Diabetes Mellitus Comprehensive Care Plan-2022 Update. (2022) · cites this paper as [1296]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive insulin therapy in critically ill patients.
Van den Berghe, G., Wouters, P., Weekers, F., Verwaest, C., Bruyninckx, F., Schetz, M., Vlasselaers, D., Ferdinande, P., Lauwers, P., & Bouillon, R. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa011300 · Cited by 9,977 · cited 2×
“The Leuven paperbased protocol [3], using a target range of 4.”
BackgroundMethodIntensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Intensive insulin therapy in the medical ICU
Van den Berghe, G., Wilmer, A., Hermans, G., Meersseman, W., Wouters, P. J., Milants, I., Van Wijngaerden, E., Bobbaers, H., & Bouillon, R. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052521 · Cited by 3,639 · cited 1×
“7% of the intervention group in the Leuven II medical ICU study experienced severe hypoglycemia, increasing to 25% among patients with ICU stays of 5 days or longer [11].”
BackgroundIntensive insulin therapy and pentastarch resuscitation in severe sepsis
Brunkhorst, F. M., Engel, C., Bloos, F., Meier-Hellmann, A., Ragaller, M., Weiler, N., Moerer, O., Gruendling, M., Oppert, M., Grond, S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070716 · Cited by 2,921
Authors/Task Force Members, Ryden, L., Standl, E., Bartnik, M., Van den Berghe, G., Betteridge, J., de Boer, M.-J., Cosentino, F., Jonsson, B., Laakso, M., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl260 · Cited by 1,647
Effect of an Intensive Glucose Management Protocol on the Mortality of Critically Ill Adult Patients
Krinsley, J. S. (2004) · Mayo Clinic Proceedings · doi:10.4065/79.8.992 · Cited by 1,223 · cited 1×
“Observational studies outside of clinical trials supported these results, finding improved outcomes after intensive insulin therapy to manage hyperglycemia in the critically ill patient [ 4-6 ].”
ResultKrinsley, J. S. (2003) · Mayo Clinic Proceedings · doi:10.4065/78.12.1471 · Cited by 1,165 · cited 1×
“Observational studies outside of clinical trials supported these results, finding improved outcomes after intensive insulin therapy to manage hyperglycemia in the critically ill patient [4-6].”
ResultFurnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130 · cited 2×
“Regarding other protocols, in a study of cardiac surgery patients with diabetes, 61% of patients achieved the glucose target range of 4.4 to 8.3 mmol/L while on continuous insulin infusion based on the Portland protocol (paper-based) with a 7.1% hypoglycemia rate (BG 2.2 mmol/L) [4].”
MethodResultInfluentialGriesdale, D. E. G., de Souza, R. J., van Dam, R. M., Heyland, D. K., Cook, D. J., Malhotra, A., Dhaliwal, R., Henderson, W. R., Chittock, D. R., Finfer, S., et al. (2009) · Canadian Medical Association Journal · doi:10.1503/cmaj.090206 · Cited by 1,096 · cited 4×
“This overarching concern for hypoglycemia has resulted in a call for more measured, less aggressive glycemic control [13-15], and higher target BG ranges (6.”
BackgroundResultInfluentialPreiser, J.-C., Devos, P., Ruiz-Santana, S., Mélot, C., Annane, D., Groeneveld, J., Iapichino, G., Leverve, X., Nitenberg, G., Singer, P., et al. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1585-2 · Cited by 911 · cited 3×
“Several large randomized controlled trials were stopped due to unacceptably high rates of severe hypoglycemia (blood glucose (BG) 9 ] and 17.0% of the tight control group in the Efficacy of Volume Substitution and Insulin Therapy in Severe Sepsis (VISEP) study [10].”
BackgroundMethodResultInfluentialSevere hypoglycemia in critically ill patients: risk factors and outcomes
Krinsley, J. S., & Grover, A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000282073.98414.4b · Cited by 671 · cited 1×
“2 mmol/L could be independently associated with increased risk of mortality [41].”
BackgroundHyperglycemia-related mortality in critically ill patients varies with admission diagnosis
Falciglia, M., Freyberg, R. W., Almenoff, P. L., D’Alessio, D. A., & Render, M. L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b083f7 · Cited by 576 · cited 1×
“Introduction Hyperglycemia is a recognized adverse factor for intensive care unit (ICU) outcomes [1,2].”
BackgroundMoghissi, E. S., Korytkowski, M. T., DiNardo, M., Einhorn, D., Hellman, R., Hirsch, I. B., Inzucchi, S. E., Ismail-Beigi, F., Kirkman, M. S., & Umpierrez, G. E. (2009) · Endocrine Practice · doi:10.4158/ep09102.ra · Cited by 518
Zeiger, M. A., Thompson, G. B., Duh, Q.-Y., Hamrahian, A. H., Angelos, P., Elaraj, D., Fishman, E., Kharlip, J., Zeiger, M. A., Thompson, G. B., et al. (2009) · Endocrine Practice · doi:10.4158/ep.15.s1.1 · Cited by 499
Implementation of a Safe and Effective Insulin Infusion Protocol in a Medical Intensive Care Unit
Goldberg, P. A., Siegel, M. D., Sherwin, R. S., Halickman, J. I., Lee, M., Bailey, V. A., Lee, S. L., Dziura, J. D., & Inzucchi, S. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.2.461 · Cited by 483
Predisposing factors for hypoglycemia in the intensive care unit*
Vriesendorp, T. M., van Santen, S., DeVries, J. H., de Jonge, E., Rosendaal, F. R., Schultz, M. J., & Hoekstra, J. B. L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000194536.89694.06 · Cited by 282 · cited 1×
“Additionally, ameliorating factors that predispose to hypoglycemia [37-39] and management of rapid fluctuations in BG levels with prompt, frequent, accurate and timely glucose measurements are external factors that contribute to the success or failure of any protocol [40].”
BackgroundChase, J., Shaw, G., Le Compte, A., Lonergan, T., Willacy, M., Wong, X.-W., Lin, J., Lotz, T., Lee, D., & Hann, C. (2008) · Critical Care · doi:10.1186/cc6868 · Cited by 262 · cited 1×
“When evaluating reports of experience with computerized insulin infusion protocols, some have shown improved glycemic control with reduced time-to-target, longer time-in-target and lower rates of hypoglycemia [20,22-35].”
BackgroundThe ACE/ADA Task Force on Inpatient Diabetes (2006) · Diabetes Care · doi:10.2337/dc06-9913 · Cited by 248
Davidson, P. C., Steed, R. D., & Bode, B. W. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2418 · Cited by 230
Intensive Insulin Therapy in Critical Care
Wilson, M., Weinreb, J., & Hoo, G. W. S. (2007) · Diabetes Care · doi:10.2337/dc06-1964 · Cited by 206
Benefits and Risks of Tight Glucose Control in Critically Ill Adults: A Meta-analysis
Wiener, R. S., Wiener, D. C., & Larson, R. J. (2008) · JAMA · doi:10.1001/jama.300.8.933 · Cited by 200 · cited 17×
“In this study, data were analyzed for adult patients with hyperglycemia treated with the GlucoStabilizer (Medical Decisions Network, Charlottesville, VA, USA) to a target range of 4.4 to 6.1 mmol/L in ICUs from March 2006 to December 2007.”
BackgroundInfluentialPlank, J., Blaha, J., Cordingley, J., Wilinska, M. E., Chassin, L. J., Morgan, C., Squire, S., Haluzik, M., Kremen, J., Svacina, S., et al. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1689 · Cited by 195 · cited 1×
“When evaluating reports of experience with computerized insulin infusion protocols, some have shown improved glycemic control with reduced time-to-target, longer time-in-target and lower rates of hypoglycemia [20, 22-35 ].”
BackgroundRacial and ethnic disparities in mortality from acute lung injury*
Erickson, S. E., Shlipak, M. G., Martin, G. S., Wheeler, A. P., Ancukiewicz, M., Matthay, M. A., & Eisner, M. D. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819292ea · Cited by 178
Meijering, S., Corstjens, A. M., Tulleken, J. E., Meertens, J. H., Zijlstra, J. G., & Ligtenberg, J. J. (2006) · Critical Care · doi:10.1186/cc3981 · Cited by 172 · cited 1×
“the performances of IV insulin protocols thereby precluding reasonable comparisons in efficacy of therapy and outcomes [13,14,17-20].”
BackgroundGlucose control in the intensive care unit
Fahy, B. G., Sheehy, A. M., & Coursin, D. B. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a19ceb · Cited by 170 · cited 1×
“Additionally, ameliorating factors that predispose to hypoglycemia [37-39] and management of rapid fluctuations in BG levels with prompt, frequent, accurate and timely glucose measurements are external factors that contribute to the success or failure of any protocol [40].”
BackgroundEarly blood glucose control and mortality in critically ill patients in Australia*
Bagshaw, S. M., Egi, M., George, C., & Bellomo, R. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e318194b097 · Cited by 167 · cited 1×
“Introduction Hyperglycemia is a recognized adverse factor for intensive care unit (ICU) outcomes [1,2].”
BackgroundVogelzang, M., Zijlstra, F., & Nijsten, M. W. (2005) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-5-38 · Cited by 139
Juneja, R., Roudebush, C., Kumar, N., Macy, A., Golas, A., Wall, D., Wolverton, C., Nelson, D., Carroll, J., & Flanders, S. J. (2007) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.0015 · Cited by 113 · cited 3×
“Use of the GlucoStabilizer has been previously described in detail [29].”
BackgroundMethodSelf-citationWHITE, N. H., SKOR, D., & SANTIAGO, J. V. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-97-2-210 · Cited by 108 · cited 1×
“In brief, when a patient BG value is entered, the program calculates an initial insulin infusion rate in units/hour using (BG in mg/dL - 60) × multiplier, set at an initial default of 0.02, (an insulin sensitivity factor) [30].”
MethodInfluentialComputer-based Insulin Infusion Protocol Improves Glycemia Control over Manual Protocol
Boord, J. B., Sharifi, M., Greevy, R. A., Griffin, M. R., Lee, V. K., Webb, T. A., May, M. E., Waitman, L. R., May, A. K., & Miller, R. A. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2292 · Cited by 94 · cited 2×
“On the other hand, computerized applications, which enable rapid, complex calculations for recommended insulin infusion rates, have demonstrated superior overall efficacy and safety in some reports [22-26], and failed to improve glycemic control or reduce hypoglycemia in others [27,28] when compared with manual protoc…”
BackgroundA replicable method for blood glucose control in critically Ill patients
Morris, A. H., Orme, J. F., Truwit, J. D., Steingrub, J. S., Grissom, C. K., Lee, K. H., Li, G., Thompson, B., Brower, R. G., Tidswell, M., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181743a5a · Cited by 91 · cited 3×
“Adjudicated causes were reported to be clinician error (failure to follow the computerized treatment algorithm and infrequent BG monitoring in 37%, decreased nutritional intake 24%, pre-terminal state 8%, spurious measurement error 16%, and other miscellaneous causes in 15% [34-36] Additionally, BG measures were taken…”
BackgroundTight glycaemic control by an automated algorithm with time-variant sampling in medical icu patients
Pachler, C., Plank, J., Weinhandl, H., Chassin, L. J., Wilinska, M. E., Kulnik, R., Kaufmann, P., Smolle, K.-H., Pilger, E., Pieber, T. R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1033-8 · Cited by 82 · cited 2×
“On the other hand, computerized applications, which enable rapid, complex calculations for recommended insulin infusion rates, have demonstrated superior overall efficacy and safety in some reports [ 22-26 ], and failed to improve glycemic control or reduce hypoglycemia in others [27,28] when compared with manual prot…”
BackgroundTight glycemic control and computerized decision-support systems: a systematic review
Eslami, S., Abu-Hanna, A., de Jonge, E., & de Keizer, N. F. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1542-0 · Cited by 64 · cited 2×
“the performances of IV insulin protocols thereby precluding reasonable comparisons in efficacy of therapy and outcomes [13,14,17-20].”
BackgroundCavalcanti, A. B., Silva, E., Pereira, A. J., Filho, M. C., de Almeida, F. P., Westphal, G. A., Beims, R., Fernandes, C. C. F., Corrêa, T. D., Gouvea, M. R., et al. (2009) · Journal of Critical Care · doi:10.1016/j.jcrc.2009.05.005 · Cited by 62 · cited 3×
“When evaluating reports of experience with computerized insulin infusion protocols, some have shown improved glycemic control with reduced time-to-target, longer time-in-target and lower rates of hypoglycemia [20, 22-35 ].”
BackgroundInfluentialShulman, R. I., Finney, S. J., O'Sullivan, C., Glynne, P. A., & Greene, R. (2007) · Critical Care · doi:10.1186/cc5964 · Cited by 61
Eslami, S., de Keizer, N. F., de Jonge, E., Schultz, M. J., & Abu-Hanna, A. (2008) · Critical Care · doi:10.1186/cc7114 · Cited by 60
Nasraway, S. A. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000286520.50104.51 · Cited by 52 · cited 1×
“These recent results have left clinicians sitting on the horns of the dilemma; how to achieve and maintain glucose control without increasing the risk of hypoglycemia [16].”
BackgroundSelf-citationHypoglycemia in the intensive care unit
Mechanick, J. I., Handelsman, Y., & Bloomgarden, Z. T. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e32802b7016 · Cited by 45 · cited 1×
“Additionally, ameliorating factors that predispose to hypoglycemia [37-39] and management of rapid fluctuations in BG levels with prompt, frequent, accurate and timely glucose measurements are external factors that contribute to the success or failure of any protocol [40].”
BackgroundInsulin Infusion Protocols for Critically ILL Patients: A Highlight of Differences and Similarities
Nazer, L. H., Chow, S. L., & Moghissi, E. S. (2007) · Endocrine Practice · doi:10.4158/ep.13.2.137 · Cited by 44 · cited 1×
“the performances of IV insulin protocols thereby precluding reasonable comparisons in efficacy of therapy and outcomes [13,14,17-20].”
BackgroundClinical Results of an Updated Insulin Infusion Protocol in Critically Ill Patients
Goldberg, P. A., Roussel, M. G., & Inzucchi, S. E. (2005) · Diabetes Spectrum · doi:10.2337/diaspect.18.3.188 · Cited by 40
Toschlog, E. A., Newton, C. A., Allen, N., Newell, M. A., Goettler, C. E., Schenarts, P. J., Bard, M. R., Sagraves, S. G., & Rotondo, M. F. (2007) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e318047b7dc · Cited by 33 · cited 2×
“On the other hand, computerized applications, which enable rapid, complex calculations for recommended insulin infusion rates, have demonstrated superior overall efficacy and safety in some reports [22-26], and failed to improve glycemic control or reduce hypoglycemia in others [27,28] when compared with manual protoc…”
BackgroundTight glucose control in intensive care units: an update with an emphasis on nutritional issues
Elia, M., & Silva, A. D. (2008) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/mco.0b013e3282fcea2a · Cited by 16 · cited 1×
“Additionally, ameliorating factors that predispose to hypoglycemia [37-39] and management of rapid fluctuations in BG levels with prompt, frequent, accurate and timely glucose measurements are external factors that contribute to the success or failure of any protocol [40].”
BackgroundClark, N. M., Finfer, S. R., & Nice-Sugar Study Investigators (2007) · Cited by 12
Research works printed but not linked: 1
- Krinsley JS, Grover A: Severe hypoglycemia in critically ill patients: risk factors and outcomes. Crit Care Med 2007, 35: 2262-2267. 10.1097/01.CCM.0000282073.98414.4B · DOI · Paper page
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
“This approach corrected the BG into the target range in 98% within 30 mins for patients who had received IV insulin infusions (95, 97).”
BackgroundMethodSelf-citationBlonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Krinsley, J. S., & Preiser, J.-C. (2015) · Critical Care · doi:10.1186/s13054-015-0908-7 · Cited by 174
“4% [35].”
Klonoff, D. C., Messler, J., Umpierrez, G. E., Peng, L., Booth, R., Crowe, J., Garrett, V., McFarland, R., & Pasquel, F. J. (2020) · Diabetes Care · doi:10.2337/dc20-1857 · Cited by 122
Monitoring in the Intensive Care
Kipnis, E., Ramsingh, D., Bhargava, M., Dincer, E., Cannesson, M., Broccard, A., Vallet, B., Bendjelid, K., & Thibault, R. (2012) · Critical Care Research and Practice · doi:10.1155/2012/473507 · Cited by 87
“In addition, computerized systems allow reducing nurses and physicians work time, time to reach the targeted glycaemia and the onset of hypoand hyperglycaemia [172, 181].”
Metadata
- Authors
- Juneja, R., Roudebush, C. P., Nasraway, S. A., Golas, A. A., Jacobi, J., Carroll, J., Nelson, D., Abad, V. J., & Flanders, S. J.
- Affiliations
- Indiana University Indianapolis (US)
- Indiana University Health (US)
- Tufts University (US)
- The Epsilon Group (US)
- Corewell Health William Beaumont University Hospital (US)
- Corresponding author
- Juneja, Rattan
- Venue
- Critical Care
- Published
- 2009-10-12
- Volume
- 13
- Issue
- 5
- Pages
- R163-R163
- ISSN
- 1364-8535 (ISSN-L)
- PMC
- PMC2784393
- OpenAlex
- W2034805451
- Cited by
- 86
- References
- 43
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 6 · 2017: 3 · 2016: 6 · 2015: 9 · 2014: 14 · 2013: 4 · 2012: 7
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0/ (tdm)
- creativecommons.org/licenses/by/2.0/ (vor)
- Locations
- Critical Care (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- IUScholarWorks (Indiana University) (submittedVersion, cc-by)
- Funders
- Vlaamse regering
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- hypoglycemia, glycemic control, hyperglycemia, critically ill patients, intensive insulin therapy, diabetes mellitus, sepsis, kidney disease, cardiovascular disease
- MeSH terms
- Adult, Algorithms, Blood Glucose, Drug Therapy, Computer-Assisted, Humans, Hypoglycemia, Infusions, Intravenous, Insulin, Intensive Care Units, Retrospective Studies, Time Factors, Glycemic Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.