The FieldTrip-SimBio pipeline for EEG forward solutions
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurately solving the electroencephalography (EEG) forward problem is crucial for precise EEG source analysis. Previous studies have shown that the use of multicompartment head models in combination with the finite element method (FEM) can yield high accuracies both numerically and with regard to the geometrical approximation of the human head. However, the workload for the generation of multicompartment head models has often been too high and the use of publicly available FEM implementations too complicated for a wider application of FEM in research studies. In this paper, we present a MATLAB-based pipeline that aims to resolve this lack of easy-to-use integrated software solutions. The presented pipeline allows for the easy application of five-compartment head models with the FEM within the FieldTrip toolbox for EEG source analysis. METHODS: The FEM from the SimBio toolbox, more specifically the St. Venant approach, was integrated into the FieldTrip toolbox. We give a short sketch of the implementation and its application, and we perform a source localization of somatosensory evoked potentials (SEPs) using this pipeline. We then evaluate the accuracy that can be achieved using the automatically generated five-compartment hexahedral head model [skin, skull, cerebrospinal fluid (CSF), gray matter, white matter] in comparison to a highly accurate tetrahedral head model that was generated on the basis of a semiautomatic segmentation with very careful and time-consuming manual corrections. RESULTS: The source analysis of the SEP data correctly localizes the P20 component and achieves a high goodness of fit. The subsequent comparison to the highly detailed tetrahedral head model shows that the automatically generated five-compartment head model performs about as well as a highly detailed four-compartment head model (skin, skull, CSF, brain). This is a significant improvement in comparison to a three-compartment head model, which is frequently used in praxis, since the importance of modeling the CSF compartment has been shown in a variety of studies. CONCLUSION: The presented pipeline facilitates the use of five-compartment head models with the FEM for EEG source analysis. The accuracy with which the EEG forward problem can thereby be solved is increased compared to the commonly used three-compartment head models, and more reliable EEG source reconstruction results can be obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 1×
“A MATLAB-based—and therefore multiplatform— FEM pipeline that is integrated in the FieldTrip-toolbox (http://www.fieldtriptoolbox. org, [23]) is presented and evaluated in this work.”
MethodSelf-citationHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“A detailed derivation of the quasi-static approximation of the EEG forward problem can be found in [1, 2].”
BackgroundOpenMEEG: opensource software for quasistatic bioelectromagnetics
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-45 · Cited by 1,154 · cited 2×
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (1999) · doi:10.1109/mcse.1999.10004 · Cited by 890
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511618635 · Cited by 580
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305 · cited 1×
“As error measures, we used the relative difference measure (RDM), which is a normalized l2-error that measures topography differences, and the logarithmic magnitude error (lnMAG), which measures magnitude differences to the reference solution [33, 34]:”
MethodA guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302 · cited 10×
“BEMs are commonly used in combination with simplified three-layer head models (skin, skull, brain), whereas FEM and FDM offer the possibility of modeling more complex geometries and also anisotropic conductivities, with only weak influence on the computational effort [6].”
BackgroundMethodInfluentialSelf-citationModeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268 · cited 2×
“This segmentation results in a constant skull thickness and thereby a missestimation of the original skull thickness in many areas, which negatively affects the forward solution accuracy due to the major influence of an accurate modeling of the skull on EEG forward solutions [5, 12, 16, 17, 40].”
BackgroundSelf-citationImproving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239 · cited 1×
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
Background
Cited by
Lead-DBS v2: Towards a comprehensive pipeline for deep brain stimulation imaging
Horn, A., Li, N., Dembek, T. A., Kappel, A., Boulay, C., Ewert, S., Tietze, A., Husch, A., Perera, T., Neumann, W.-J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.068 · Cited by 739
Self-citationA unified connectomic target for deep brain stimulation in obsessive-compulsive disorder
Li, N., Baldermann, J. C., Kibleur, A., Treu, S., Akram, H., Elias, G. J. B., Boutet, A., Lozano, A. M., Al-Fatly, B., Strange, B., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16734-3 · Cited by 316
Lead-DBS v3.0: Mapping deep brain stimulation effects to local anatomy and global networks
Neudorfer, C., Butenko, K., Oxenford, S., Rajamani, N., Achtzehn, J., Goede, L., Hollunder, B., Ríos, A. S., Hart, L., Tasserie, J., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119862 · Cited by 221
“stimulation volumes were additionally calculated in native space using an adaptation of the SimBio/FieldTrip pipeline (Vorwerk et al., 2018) as introduced in Lead-DBS v2 and refined for robustness and precision.”
MethodHorn, A., Wenzel, G., Irmen, F., Huebl, J., Li, N., Neumann, W.-J., Krause, P., Bohner, G., Scheel, M., & Kühn, A. A. (2019) · Brain · doi:10.1093/brain/awz239 · Cited by 170
“A voxel-wise parcellation scheme with 8k nodes in grey matter (see “Voxelwise parcellations (Lead-DBS)” under http://www.lead-dbs.org/helpsupport/knowledgebase/atlasesresources/cortical-atlas-parcellations-mni-space) was inversely registered to rs-fMRI volumes (via the T1 anchor modality) and signals were sampled from…”
MethodInfluentialDeep brain stimulation of symptom-specific networks in Parkinson’s disease
Rajamani, N., Friedrich, H., Butenko, K., Dembek, T., Lange, F., Navrátil, P., Zvarova, P., Hollunder, B., de Bie, R. M. A., Odekerken, V. J. J., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48731-1 · Cited by 118
“Namely, while the forward solution provided by the SimBio/FieldTrip pipeline 37 as employed here, solves the static formulation of Laplace ’ s equation to estimate the electric fi eld in an established fashion (as widely used in the EEG literature), our process ends there and we calculate statistics…”
Bury, G., García-Huéscar, M., Bhattacharya, J., & Ruiz, M. H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.04.043 · Cited by 20
A human brain network linked to restoration of consciousness after deep brain stimulation
Warren, A. E. L., Raguž, M., Friedrich, H., Schaper, F. L. W. V. J., Tasserie, J., Snider, S. B., Li, J., Chua, M. M. J., Butenko, K., Friedrich, M. U., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-61988-4 · Cited by 18
Metadata
- Authors
- Vorwerk, J., Oostenveld, R., Piastra, M. C., Magyari, L., & Wolters, C. H.
- Venue
- BioMedical Engineering OnLine
- Published
- 2018-03-27
- Volume
- 17
- Issue
- 1
- Pages
- 37-37
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2794649691
- Cited by
- 172
- References
- 36
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.