The FieldTrip-SimBio pipeline for EEG forward solutions
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurately solving the electroencephalography (EEG) forward problem is crucial for precise EEG source analysis. Previous studies have shown that the use of multicompartment head models in combination with the finite element method (FEM) can yield high accuracies both numerically and with regard to the geometrical approximation of the human head. However, the workload for the generation of multicompartment head models has often been too high and the use of publicly available FEM implementations too complicated for a wider application of FEM in research studies. In this paper, we present a MATLAB-based pipeline that aims to resolve this lack of easy-to-use integrated software solutions. The presented pipeline allows for the easy application of five-compartment head models with the FEM within the FieldTrip toolbox for EEG source analysis. METHODS: The FEM from the SimBio toolbox, more specifically the St. Venant approach, was integrated into the FieldTrip toolbox. We give a short sketch of the implementation and its application, and we perform a source localization of somatosensory evoked potentials (SEPs) using this pipeline. We then evaluate the accuracy that can be achieved using the automatically generated five-compartment hexahedral head model [skin, skull, cerebrospinal fluid (CSF), gray matter, white matter] in comparison to a highly accurate tetrahedral head model that was generated on the basis of a semiautomatic segmentation with very careful and time-consuming manual corrections. RESULTS: The source analysis of the SEP data correctly localizes the P20 component and achieves a high goodness of fit. The subsequent comparison to the highly detailed tetrahedral head model shows that the automatically generated five-compartment head model performs about as well as a highly detailed four-compartment head model (skin, skull, CSF, brain). This is a significant improvement in comparison to a three-compartment head model, which is frequently used in praxis, since the importance of modeling the CSF compartment has been shown in a variety of studies. CONCLUSION: The presented pipeline facilitates the use of five-compartment head models with the FEM for EEG source analysis. The accuracy with which the EEG forward problem can thereby be solved is increased compared to the commonly used three-compartment head models, and more reliable EEG source reconstruction results can be obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 1×
“A MATLAB-based—and therefore multiplatform— FEM pipeline that is integrated in the FieldTrip-toolbox (http://www.fieldtriptoolbox. org, [23]) is presented and evaluated in this work.”
MethodSelf-citationHämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684 · cited 1×
“A detailed derivation of the quasi-static approximation of the EEG forward problem can be found in [1, 2].”
BackgroundOpenMEEG: opensource software for quasistatic bioelectromagnetics
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-45 · Cited by 1,154 · cited 2×
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
Realistic conductivity geometry model of the human head for interpretation of neuromagnetic data
Hamalainen, M. S., & Sarvas, J. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.16463 · Cited by 989
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (1999) · doi:10.1109/mcse.1999.10004 · Cited by 890
Finite Elements: Theory, Fast Solvers, and Applications in Solid Mechanics
Braess, D. (2007) · Cambridge University Press eBooks · doi:10.1017/cbo9780511618635 · Cited by 580
On the numerical accuracy of the boundary element method (EEG application)
Meijs, J. W. H., Weier, O. W., Peters, M. J., & Van Oosterom, A. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.40805 · Cited by 305 · cited 1×
“As error measures, we used the relative difference measure (RDM), which is a normalized l2-error that measures topography differences, and the logarithmic magnitude error (lnMAG), which measures magnitude differences to the reference solution [33, 34]:”
MethodA guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302 · cited 10×
“BEMs are commonly used in combination with simplified three-layer head models (skin, skull, brain), whereas FEM and FDM offer the possibility of modeling more complex geometries and also anisotropic conductivities, with only weak influence on the computational effort [6].”
BackgroundMethodInfluentialSelf-citationModeling of the human skull in EEG source analysis
Dannhauer, M., Lanfer, B., Wolters, C. H., & Knösche, T. R. (2011) · Human Brain Mapping · doi:10.1002/hbm.21114 · Cited by 268 · cited 2×
“This segmentation results in a constant skull thickness and thereby a missestimation of the original skull thickness in many areas, which negatively affects the forward solution accuracy due to the major influence of an accurate modeling of the skull on EEG forward solutions [5, 12, 16, 17, 40].”
BackgroundSelf-citationImproving source reconstructions by combining bioelectric and biomagnetic data
Fuchs, M., Wagner, M., Wischmann, H.-A., Köhler, T., Theißen, A., Drenckhahn, R., & Buchner, H. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00046-7 · Cited by 239 · cited 1×
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
BackgroundGüllmar, D., Haueisen, J., & Reichenbach, J. R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.014 · Cited by 214 · cited 1×
“As error measures, we used the relative difference measure (RDM), which is a normalized l2-error that measures topography differences, and the logarithmic magnitude error (lnMAG), which measures magnitude differences to the reference solution [33, 34]:”
MethodFeature Selection for Interpatient Supervised Heart Beat Classification
Doquire, G., de Lannoy, G., François, D., & Verleysen, M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/643816 · Cited by 192
Subject position affects EEG magnitudes
Rice, J. K., Rorden, C., Little, J. S., & Parra, L. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.041 · Cited by 181 · cited 2×
“The EEG was measured with the subject in supine position to prevent erroneous CSF effects due to brain shift when combining EEG and MRI, following the results of [32].”
BackgroundMethodInverse localization of electric dipole current sources in finite element models of the human head
Buchner, H., Knoll, G., Fuchs, M., Rienäcker, A., Beckmann, R., Wagner, M., Silny, J., & Pesch, J. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95698-9 · Cited by 180 · cited 2×
“…implementation from the SimBio toolbox (https://www.mrt.uni-jena.de/simbio/, [ 24]) sb_rhs_venant: calculates the rhs-vector b ven (cf. ( 4); [24, 30, 31]); takes the mesh geometry and source position and direction as input; output is the rhs-vector b ven ; sb_set_bndcon: sets the Dirichlet…”
MethodInvestigation of tDCS volume conduction effects in a highly realistic head model
Wagner, S., Rampersad, S. M., Aydin, Ü., Vorwerk, J., Oostendorp, T. F., Neuling, T., Herrmann, C. S., Stegeman, D. F., & Wolters, C. H. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016002 · Cited by 177 · cited 1×
“Examples of the use of geometry-adapted hexahedral meshes can be found in the studies of [25–27]; evaluations of the numerical accuracy achieved using geometry-adapted hexahedral meshes in sphere models were performed by [24, 28].”
MethodSelf-citationWolters, C. H., Grasedyck, L., & Hackbusch, W. (2004) · Inverse Problems · doi:10.1088/0266-5611/20/4/007 · Cited by 172 · cited 2×
“, the stiffness matrix à and rhs-vector b̃, as input; output is the solution vector u; sb_transfer: computes the EEG transfer matrix T [19]; takes the stiffness matrix, the mesh geometry, and the sensor positions as input; output is the transfer matrix.”
MethodSelf-citationHandbook of Neural Activity Measurement
(2012) · Cambridge University Press eBooks · doi:10.1017/cbo9780511979958 · Cited by 151 · cited 1×
“A detailed derivation of the quasi-static approximation of the EEG forward problem can be found in [1, 2].”
BackgroundForward Field Computation with OpenMEEG
Gramfort, A., Papadopoulo, T., Olivi, E., & Clerc, M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/923703 · Cited by 129
Aydın, Ü., Vorwerk, J., Dümpelmann, M., Küpper, P., Kugel, H., Heers, M., Wellmer, J., Kellinghaus, C., Haueisen, J., Rampp, S., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118753 · Cited by 124
Self-citationInfluence of the head model on EEG and MEG source connectivity analyses
Cho, J., Vorwerk, J., Wolters, C. H., & Knösche, T. R. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.01.043 · Cited by 123
Self-citationQuantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation.
Kazemi, K., & Noorizadeh, N. (2014) · PubMed Central · Cited by 123
Influence of Skull Modeling Approaches on EEG Source Localization
Montes-Restrepo, V., van Mierlo, P., Strobbe, G., Staelens, S. G., Vandenberghe, S., & Hallez, H. (2013) · Brain Topography · doi:10.1007/s10548-013-0313-y · Cited by 118 · cited 3×
“This segmentation results in a constant skull thickness and thereby a missestimation of the original skull thickness in many areas, which negatively affects the forward solution accuracy due to the major influence of an accurate modeling of the skull on EEG forward solutions [5, 12, 16, 17, 40].”
BackgroundMethodInfluences of skull segmentation inaccuracies on EEG source analysis
Lanfer, B., Scherg, M., Dannhauer, M., Knösche, T. R., Burger, M., & Wolters, C. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.006 · Cited by 113 · cited 2×
“The inaccurate segmentation of the nose/mouth area with FieldTrip should have only a minor influence because the model is nevertheless not cut off directly below the skull following the advice of [21].”
BackgroundSelf-citationBioelectromagnetic forward problem: isolated source approach revis(it)ed
Stenroos, M., & Sarvas, J. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/3517 · Cited by 104
Lew, S., Wolters, C. H., Dierkes, T., Röer, C., & MacLeod, R. (2009) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2009.02.006 · Cited by 100 · cited 5×
“…Venant FEM approach was compared to other FEM approaches, i.e., partial integration, subtraction, and Whitney, in multiple sphere model studies in both hexahedral and tetrahedral meshes and was shown to achieve the best combination of accuracy, robustness, and computation speed [13, 15, 31, 38].”
MethodInfluentialSelf-citationWolters, C. H., Anwander, A., Berti, G., & Hartmann, U. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.890736 · Cited by 98 · cited 6×
“For a detailed description of the computation of the right-hand side vector b = b ven for the St. Venant approach and a comparison with other approaches for dipole modeling, we refer the reader to [24, 30, 31].”
BackgroundMethodInfluentialSelf-citationCamacho, D., Hopper, R. H., Lin, G. M., & Myers, B. S. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00073-0 · Cited by 98 · cited 3×
“To avoid the occurence of staircase effects, the generation of geometry-adapted meshes is implemented [22].”
BackgroundMethodComparison of Boundary Element and Finite Element Approaches to the EEG Forward Problem
Vorwerk, J., Clerc, M., Burger, M., & Wolters, C. H. (2012) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-4152 · Cited by 80 · cited 2×
“Finite element methods have been shown to achieve high numerical accuracies [13, 18], and the computational burden has been clearly reduced by the introduction of transfer matrices and fast solver techniques [19].”
MethodSelf-citationStenroos, M., & Nummenmaa, A. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0159595 · Cited by 77 · cited 1×
“The pipeline thus offers a clear advantage when compared to the current standard of isotropic three-compartment head models that is still frequently used in EEG source analysis [39, 42, 43].”
BackgroundDrechsler, F., Wolters, C. H., Dierkes, T., Si, H., & Grasedyck, L. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.024 · Cited by 71
Self-citationA Discontinuous Galerkin Method to Solve the EEG Forward Problem Using the Subtraction Approach
Engwer, C., Vorwerk, J., Ludewig, J., & Wolters, C. H. (2017) · SIAM Journal on Scientific Computing · doi:10.1137/15m1048392 · Cited by 59 · cited 2×
“This segmentation results in a constant skull thickness and thereby a missestimation of the original skull thickness in many areas, which negatively affects the forward solution accuracy due to the major influence of an accurate modeling of the skull on EEG forward solutions [5, 12, 16, 17, 40].”
Self-citationAydın, Ü., Rampp, S., Wollbrink, A., Kugel, H., Cho, J. H., Knösche, T. R., Grova, C., Wellmer, J., & Wolters, C. H. (2017) · Brain Topography · doi:10.1007/s10548-017-0568-9 · Cited by 50 · cited 1×
“Examples of the use of geometry-adapted hexahedral meshes can be found in the studies of [25–27]; evaluations of the numerical accuracy achieved using geometry-adapted hexahedral meshes in sphere models were performed by [24, 28].”
MethodSelf-citationA Mixed Finite Element Method to Solve the EEG Forward Problem
Vorwerk, J., Engwer, C., Pursiainen, S., & Wolters, C. H. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2624634 · Cited by 44 · cited 3×
“This segmentation results in a constant skull thickness and thereby a missestimation of the original skull thickness in many areas, which negatively affects the forward solution accuracy due to the major influence of an accurate modeling of the skull on EEG forward solutions [5, 12, 16, 17, 40].”
BackgroundMethodSelf-citationThe Effect of Head Model Simplification on Beamformer Source Localization
Neugebauer, F., Möddel, G., Rampp, S., Burger, M., & Wolters, C. H. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00625 · Cited by 33
Self-citationBauer, M., Pursiainen, S., Vorwerk, J., Köstler, H., & Wolters, C. H. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2439282 · Cited by 31 · cited 1×
“…Venant FEM approach was compared to other FEM approaches, i.e., partial integration, subtraction, and Whitney, in multiple sphere model studies in both hexahedral and tetrahedral meshes and was shown to achieve the best combination of accuracy, robustness, and computation speed [13, 15, 31, 38].”
MethodSelf-citationPursiainen, S., Vorwerk, J., & Wolters, C. H. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/24/8502 · Cited by 31 · cited 3×
“…Venant FEM approach was compared to other FEM approaches, i.e., partial integration, subtraction, and Whitney, in multiple sphere model studies in both hexahedral and tetrahedral meshes and was shown to achieve the best combination of accuracy, robustness, and computation speed [13, 15, 31, 38].”
MethodSelf-citation
Cited by
Lead-DBS v2: Towards a comprehensive pipeline for deep brain stimulation imaging
Horn, A., Li, N., Dembek, T. A., Kappel, A., Boulay, C., Ewert, S., Tietze, A., Husch, A., Perera, T., Neumann, W.-J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.068 · Cited by 739
Self-citationA unified connectomic target for deep brain stimulation in obsessive-compulsive disorder
Li, N., Baldermann, J. C., Kibleur, A., Treu, S., Akram, H., Elias, G. J. B., Boutet, A., Lozano, A. M., Al-Fatly, B., Strange, B., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16734-3 · Cited by 316
Lead-DBS v3.0: Mapping deep brain stimulation effects to local anatomy and global networks
Neudorfer, C., Butenko, K., Oxenford, S., Rajamani, N., Achtzehn, J., Goede, L., Hollunder, B., Ríos, A. S., Hart, L., Tasserie, J., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119862 · Cited by 221
“stimulation volumes were additionally calculated in native space using an adaptation of the SimBio/FieldTrip pipeline (Vorwerk et al., 2018) as introduced in Lead-DBS v2 and refined for robustness and precision.”
MethodHorn, A., Wenzel, G., Irmen, F., Huebl, J., Li, N., Neumann, W.-J., Krause, P., Bohner, G., Scheel, M., & Kühn, A. A. (2019) · Brain · doi:10.1093/brain/awz239 · Cited by 170
“A voxel-wise parcellation scheme with 8k nodes in grey matter (see “Voxelwise parcellations (Lead-DBS)” under http://www.lead-dbs.org/helpsupport/knowledgebase/atlasesresources/cortical-atlas-parcellations-mni-space) was inversely registered to rs-fMRI volumes (via the T1 anchor modality) and signals were sampled from…”
MethodInfluentialDeep brain stimulation of symptom-specific networks in Parkinson’s disease
Rajamani, N., Friedrich, H., Butenko, K., Dembek, T., Lange, F., Navrátil, P., Zvarova, P., Hollunder, B., de Bie, R. M. A., Odekerken, V. J. J., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48731-1 · Cited by 118
“Namely, while the forward solution provided by the SimBio/FieldTrip pipeline 37 as employed here, solves the static formulation of Laplace ’ s equation to estimate the electric fi eld in an established fashion (as widely used in the EEG literature), our process ends there and we calculate statistics…”
Metadata
- Authors
- Vorwerk, J., Oostenveld, R., Piastra, M. C., Magyari, L., & Wolters, C. H.
- Venue
- BioMedical Engineering OnLine
- Published
- 2018-03-27
- Volume
- 17
- Issue
- 1
- Pages
- 37-37
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W2794649691
- Cited by
- 172
- References
- 36
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.