Functional electrical stimulation therapy for restoration of motor function after spinal cord injury and stroke: a review
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Functional electrical stimulation is a technique to produce functional movements after paralysis. Electrical discharges are applied to a person’s muscles making them contract in a sequence that allows performing tasks such as grasping a key, holding a toothbrush, standing, and walking. The technology was developed in the sixties, during which initial clinical use started, emphasizing its potential as an assistive device. Since then, functional electrical stimulation has evolved into an important therapeutic intervention that clinicians can use to help individuals who have had a stroke or a spinal cord injury regain their ability to stand, walk, reach, and grasp. With an expected growth in the aging population, it is likely that this technology will undergo important changes to increase its efficacy as well as its widespread adoption. We present here a series of functional electrical stimulation systems to illustrate the fundamentals of the technology and its applications. Most of the concepts continue to be in use today by modern day devices. A brief description of the potential future of the technology is presented, including its integration with brain–computer interfaces and wearable (garment) technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Bramer, W. M., Rethlefsen, M. L., Kleijnen, J., & Franco, O. H. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0644-y · Cited by 2,114
Neuroplasticity Subserving Motor Skill Learning
Dayan, E., & Cohen, L. G. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.008 · Cited by 1,408
Kandel, E. R., Koester, J. D., Mack, S. H., & Siegelbaum, S. A. (1985) · Cited by 1,180
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 1,033
Pfurtscheller, G., Müller, G. R., Pfurtscheller, J., Gerner, H. J., & Rupp, R. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(03)00947-9 · Cited by 548
EEG-based neuroprosthesis control: A step towards clinical practice
Müller-Putz, G. R., Scherer, R., Pfurtscheller, G., & Rupp, R. (2005) · Neuroscience Letters · doi:10.1016/j.neulet.2005.03.021 · Cited by 477 · cited 1×
“Later, the same group presented the control of an implanted FES system for grasping [59].”
BackgroundNeuromuscular Stimulation for Upper Extremity Motor and Functional Recovery in Acute Hemiplegia
Chae, J., Bethoux, F., Bohinc, T., Dobos, L., Davis, T., & Friedl, A. (1998) · Stroke · doi:10.1161/01.str.29.5.975 · Cited by 310
Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90333-7 · Cited by 275 · cited 5×
“The FDA-approved device is commercialized by Odstock Medical Limited (Salisbury, Wiltshire, UK) and has been used by hundreds of individuals.”
BackgroundMethodInfluentialDaly, J. J., Cheng, R., Rogers, J., Litinas, K., Hrovat, K., & Dohring, M. (2009) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e3181c1fc0b · Cited by 274
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
Glanz, M., Klawansky, S., Stason, W., Berkey, C., & Chalmers, T. C. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90293-2 · Cited by 254
Prochazka, A., Gauthier, M., Wieler, M., & Kenwell, Z. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90426-3 · Cited by 250
Cauraugh, J. H., & Kim, S. (2002) · Stroke · doi:10.1161/01.str.0000016926.77114.a6 · Cited by 250
Effect of timing of hip extension assistance during loaded walking with a soft exosuit
Ding, Y., Panizzolo, F. A., Siviy, C., Malcolm, P., Galiana, I., Holt, K. G., & Walsh, C. J. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0196-8 · Cited by 249
Thrasher, T. A., Zivanovic, V., McIlroy, W., & Popovic, M. R. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308317436 · Cited by 241
Self-citationEraifej, J., Clark, W., France, B., Desando, S., & Moore, D. (2017) · Systematic Reviews · doi:10.1186/s13643-017-0435-5 · Cited by 221
Stein, R. B., Everaert, D. G., Thompson, A. K., Chong, S. L., Whittaker, M., Robertson, J., & Kuether, G. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968309347681 · Cited by 208
de Kroon, J. R., van der Lee, J. H., IJzerman, M. J., & Lankhorst, G. J. (2002) · Clinical Rehabilitation · doi:10.1191/0269215502cr504oa · Cited by 205
Surface-stimulation technology for grasping and walking neuroprostheses
Popović, M. R., Keller, T., Papas, I., Dietz, V., & Morari, M. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897831 · Cited by 180
Popovic, M. R., Kapadia, N., Zivanovic, V., Furlan, J. C., Craven, B. C., & McGillivray, C. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968310392924 · Cited by 174
Self-citationNeural prostheses: Replacing motor function after disease or disability
Hilton-Jones, D. (1993) · Neuromuscular Disorders · doi:10.1016/0960-8966(93)90069-v · Cited by 164
Hybrid FES orthosis incorporating closed loop control and sensory feedback
Andrews, B. J., Baxendale, R. H., Barnett, R., Phillips, G. F., Yamazaki, T., Paul, J. P., & Freeman, P. A. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90099-4 · Cited by 155
Mangold, S., Keller, T., Curt, A. E. P., & Dietz, V. (2004) · Spinal Cord · doi:10.1038/sj.sc.3101644 · Cited by 143
Solomonow, M., Baratta, R. V., Hirokawa, S., Rightor, N., Walker, W., Beaudette, P., Shoji, H., & D'Ambrosia, R. D. (1989) · Orthopedics · doi:10.3928/0147-7447-19891001-06 · Cited by 141
Screen printed fabric electrode array for wearable functional electrical stimulation
Yang, K., Freeman, C. T., Torah, R. N., Beeby, S., & Tudor, J. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.03.025 · Cited by 136
Clinical evaluation of the bionic glove
Popović, D. B., Stojanović, A., Pjanovic, A., Radosavljević, S., Popović, M., Jović, S., & Vulović, D. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90141-7 · Cited by 133
Hausdorff, J. M., & Ring, H. (2008) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31815e6680 · Cited by 133
Kapadia, N. M., Masani, K., Craven, B. C., Giangregorio, L., Hitzig, S. L., Richards, K., & Popović, M. R. (2014) · Journal of Spinal Cord Medicine · doi:10.1179/2045772314y.0000000263 · Cited by 131
Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia
Burridge, J., Haugland, M., Larsen, B., Pickering, R., Svaneborg, N., Iversen, H., Christensen, P., Haase, J., Brennum, J., & Sinkjaer, T. (2007) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0039 · Cited by 129
Therapy of paretic arm in hemiplegic subjects augmented with a neural prosthesis: A cross-over study
Popović, D. B., Popović, M. B., Sinkjær, T., Stefanovic, A., & Schwirtlich, L. B. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-057 · Cited by 126
Hybrid assistive system-the motor neuroprosthesis
Popovic, D., Tomovic, R., & Schwirtlich, L. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32105 · Cited by 125
Neural prostheses : replacing motor function after disease or disability
Stein, R. B., Peckham, P. H., & Popović, D. B. (1992) · Oxford University Press eBooks · Cited by 117
Graupe, D., & Kohn, K. H. (1998) · Surgical Neurology · doi:10.1016/s0090-3019(98)00074-3 · Cited by 105
Modular transcutaneous functional electrical stimulation system
Popović, M. R., & Keller, T. (2004) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2004.08.016 · Cited by 104
Triolo, R. J., Bieri, C., Uhlir, J., Kobetic, R., Scheiner, A., & Marsolais, E. B. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90133-1 · Cited by 102
Bajd, T., Kralj, A. R., Štefančič, M., & Lavrač, N. (1999) · Artificial Organs · doi:10.1046/j.1525-1594.1999.06360.x · Cited by 102
Neuroprosthesis for Retraining Reaching and Grasping Functions in Severe Hemiplegic Patients
Popović, M. R., Thrasher, T. A., Zivanovic, V., Takaki, J., & Hajek, V. E. (2005) · Neuromodulation Technology at the Neural Interface · doi:10.1111/j.1094-7159.2005.05221.x · Cited by 101
Enhancement of Gait Restoration in Spinal Injured Patients by Functional Electrical Stimulation
Kralj, A. R., Bajd, T., & Turk, R. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198808000-00006 · Cited by 100
Merletti, R., Zelaschi, F., Latella, D., Galli, M., Angeli, S., & Sessa, M. B. (1978) · PubMed · Cited by 98
A flexible, portable system for neuromuscular stimulation in the paralyzed upper extremity
Buckett, J. R., Peckham, P. H., Thrope, G. B., Braswell, S. D., & Keith, M. W. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8669 · Cited by 97
Kowalczewski, J. A., Gritsenko, V., Ashworth, N. L., ELLAWAY, P. H., & Procházka, A. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.03.036 · Cited by 96
Stimulating the Comfort of Textile Electrodes in Wearable Neuromuscular Electrical Stimulation
Zhou, H. D., Lu, Y., Chen, W., Wu, Z. Z., Zou, H., Krundel, L. A., & Li, G. (2015) · Sensors · doi:10.3390/s150717241 · Cited by 88
Intramuscular Hand Neuroprosthesis for Chronic Stroke Survivors
Chae, J., & Hart, R. L. (2003) · Neurorehabilitation and neural repair · doi:10.1177/0888439003017002005 · Cited by 78
Proportionally controlled functional electrical stimulation of hand.
Rebersek, S., & Vodovnik, L. (1973) · PubMed · Cited by 78
Gritsenko, V., & Procházka, A. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.08.094 · Cited by 76
Kapadia, N. M., Zivanovic, V., & Popović, M. R. (2013) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/sci1904-279 · Cited by 75
Hendricks, H. T., IJzerman, M. J., de Kroon, J. R., Groen, F. A. C. G. I. '., & Zilvold, G. (2001) · Clinical Rehabilitation · doi:10.1191/026921501672937235 · Cited by 65
Garments for functional electrical stimulation: Design and proofs of concept
Moineau, B., Márquez-Chin, C., Alizadeh-Meghrazi, M., & Popović, M. R. (2019) · Journal of Rehabilitation and Assistive Technologies Engineering · doi:10.1177/2055668319854340 · Cited by 63
Advances in selective activation of muscles for non-invasive motor neuroprostheses
Koutsou, A. D., Moreno, J. C., del‐Ama, A. J., Rocón, E., & Pons, J. L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0165-2 · Cited by 62
An Implantable Two Channel Drop Foot Stimulator: Initial Clinical Results
Kenney, L., Bultstra, G., Buschman, R., Taylor, P., Mann, G., Hermens, H., Holsheimer, J., Nene, A., Tenniglo, M., Van der Aa, H., et al. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06949.x · Cited by 55
Márquez-Chin, C., Marquis, A., & Popović, M. R. (2016) · Case Reports in Neurological Medicine · doi:10.1155/2016/9146213 · Cited by 53
A programmable electronic stimulator for FES systems
Ilic, M., Vasiljević, D., & Popović, D. B. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.340875 · Cited by 51
Chae, J., Harley, M. Y., Hisel, T. Z., Corrigan, C. M., Demchak, J. A., Wong, Y.-T., & Fang, Z.-P. (2009) · Neurorehabilitation and neural repair · doi:10.1177/1545968308328729 · Cited by 49
The next revolution in stroke care
Teasell, R. W., Rice, D. B., Richardson, M., Campbell, N., Madady, M., Hussein, N., Murie-Fernández, M., & Page, S. J. (2014) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.2014.968130 · Cited by 41
Recent Applications of Functional Electrical Stimulation to Stroke Patients in Ljubljana
VODOVNIK, L., Kralj, A. R., STANK, U., Aćimović, R., & Gros, N. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197803000-00009 · Cited by 37
Jovanovic, L. I., Kapadia, N., Lo, L., Zivanovic, V., Popovic, M. R., & Marquez-Chin, C. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001163 · Cited by 36
Therapeutic effects of functional electrical stimulation of extremities
Vodovnik, L. (1981) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441314 · Cited by 34
Nagai, M. K., Márquez-Chin, C., & Popović, M. R. (2016) · Springer eBooks · doi:10.1007/978-1-4899-7654-3_25 · Cited by 32
Burridge, J. H., Swain, I., & Taylor, P. (1998) · Reviews in Clinical Gerontology · doi:10.1017/s0959259898008260 · Cited by 29
Márquez-Chin, C., Popović, M. R., Cameron, T., Lozano, A. M., & Chen, R. E. (2009) · Spinal Cord · doi:10.1038/sc.2009.41 · Cited by 27
Hebert, D. A., Bowen, J. M., Ho, C., Antunes, I., O’Reilly, D. J., & Bayley, M. T. (2017) · British Journal of Occupational Therapy · doi:10.1177/0308022617719807 · Cited by 27
Electrical stimulation and feedback training: effects on the voluntary control of paretic muscles.
El, T., McNeal, D. R., Kralj, A., & Waters, R. L. (1976) · PubMed · Cited by 16
Cited by
Stroke rehabilitation: from diagnosis to therapy
Li, X., He, Y., Wang, D., & Rezaei, M. J. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1402729 · Cited by 178
Metadata
- Authors
- Marquez-Chin, C., & Popovic, M. R.
- Venue
- BioMedical Engineering OnLine
- Published
- 2020-05-24
- Volume
- 19
- Issue
- 1
- Pages
- 34-34
- ISSN
- 1475-925X (ISSN-L)
- OpenAlex
- W3027276198
- Cited by
- 349
- References
- 65
- FWCI
- 16.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.