Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Open accessThe DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
A significant number of surgical patients are at risk of intra- or post-operative complications or both, which are associated with increased lengths of stay, costs, and mortality. Reducing these risks is important for the individual patient but also for health-care planners and managers. Insufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications. Adequate perioperative management guided by effective and timely hemodynamic monitoring can help reduce the risk of complications and thus potentially improve outcomes. In this review, we describe the various available hemodynamic monitoring systems and how they can best be used to guide cardiovascular and fluid management in the perioperative period in high-risk surgical patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An estimation of the global volume of surgery: a modelling strategy based on available data
Weiser, T. G., Regenbogen, S. E., Thompson, K. D., Haynes, A. B., Lipsitz, S. R., Berry, W. R., & Gawande, A. A. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60878-8 · Cited by 2,511 · cited 1×
“An estimated 230 million surgical procedures are performed each year around the world [1], and a significant number are in patients at risk of intra- or post-operative complications or both.”
BackgroundMarik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516 · cited 1×
“Although changes in CVP correlate poorly with changes in CO [16] (as for pulmonary artery occlusion pressure), they can be used to assess the dynamic response to a fluid challenge [17] and to diagnose severe hypovolemia or cardiac dysfunction or both, especially where other monitoring systems are not available.”
BackgroundKhuri, S. F., Henderson, W. G., DePalma, R. G., Mosca, C., Healey, N. A., & Kumbhani, D. J. (2005) · Annals of Surgery · doi:10.1097/01.sla.0000179621.33268.83 · Cited by 1,452 · cited 1×
“Even for those patients who survive to leave hospital, postoperative complications remain an important determinant of functional recovery, long-term survival [5], and health-care costs.”
BackgroundA trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434 · cited 1×
“A recent study and meta-analysis have indicated a decreased rate of post-operative complications when low tidal volumes are applied during anesthesia [65,66], and increased use of protective ventilation (lower tidal volumes) in the OR may reduce the usefulness of dynamic parameters or at least require new interpretati…”
BackgroundCritchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325 · cited 1×
“Not all monitoring devices have been evaluated against the same set of criteria, and uncertainty remains regarding acceptance thresholds for the performance of CO monitors and the used reference techniques [54-57].”
BackgroundMarik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272 · cited 1×
“Some authors have suggested that they require a tidal volume of at least 8 mL/kg body weight [64], although they have been successfully used with tidal volumes of 6 to 8 mL/kg body weight [61,62].”
MethodWesterhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181 · cited 1×
“The ClearSight monitor estimates CO on a beat-to-beat basis by dividing the integrated pulsatile systolic area by the aortic input impedance, which in turn is derived from a three-element Windkessel model incorporating patient-specific aortic mechanical characteristics [40].”
MethodHarvey, S., Harrison, D. A., Singer, M., Ashcroft, J., Jones, C. M., Elbourne, D., Brampton, W., Williams, D., Young, D., & Rowan, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67061-4 · Cited by 1,126
Hamilton, M. A., Cecconi, M., & Rhodes, A. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181eeaae5 · Cited by 898 · cited 1×
“sufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications and poor outcomes [6-9].”
BackgroundSelf-citationJansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894 · cited 1×
“Hyperlactatemia is associated with increased morbidity and mortality in critically ill patients [87-90].”
BackgroundPearse, R. M., Harrison, D. A., MacDonald, N., Gillies, M. A., Blunt, M., Ackland, G., Grocott, M. P. W., Ahern, A., Griggs, K., Scott, R., et al. (2014) · JAMA · doi:10.1001/jama.2014.5305 · Cited by 862 · cited 1×
“There is good evidence that use of flow-based hemodynamic monitoring combined with hemodynamic manipulation in the perioperative period can reduce morbidity and sometimes mortality [83,91-97].”
BackgroundSelf-citationSerpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843 · cited 1×
“A recent study and meta-analysis have indicated a decreased rate of post-operative complications when low tidal volumes are applied during anesthesia [65,66], and increased use of protective ventilation (lower tidal volumes) in the OR may reduce the usefulness of dynamic parameters or at least require new interpretati…”
BackgroundShah, M. R., Hasselblad, V., Stevenson, L. W., Binanay, C., O’Connor, C. M., Sopko, G., & Califf, R. M. (2005) · JAMA · doi:10.1001/jama.294.13.1664 · Cited by 790
Wilson, J., Woods, I., Fawcett, J., Whall, R., Dibb, W., Morris, C., & McManus, E. (1999) · BMJ · doi:10.1136/bmj.318.7191.1099 · Cited by 769 · cited 1×
“There is good evidence that use of flow-based hemodynamic monitoring combined with hemodynamic manipulation in the perioperative period can reduce morbidity and sometimes mortality [83,91-97].”
BackgroundBakker, J., Coffernils, M., Leon, M., Gris, P., & Vincent, J.-L. (1991) · Chest · doi:10.1378/chest.99.4.956 · Cited by 718 · cited 1×
“Hyperlactatemia is associated with increased morbidity and mortality in critically ill patients [87-90].”
BackgroundSelf-citationPearse, R., Dawson, D., Fawcett, J., Rhodes, A., Grounds, R. M., & Bennett, E. D. (2005) · Critical Care · doi:10.1186/cc3887 · Cited by 698 · cited 1×
“There is good evidence that use of flow-based hemodynamic monitoring combined with hemodynamic manipulation in the perioperative period can reduce morbidity and sometimes mortality [83,91-97].”
BackgroundSelf-citationIdentification and characterisation of the high-risk surgical population in the United Kingdom
Pearse, R. M., Harrison, D. A., James, P., Watson, D., Hinds, C., Rhodes, A., Grounds, R. M., & Bennett, E. D. (2006) · Critical Care · doi:10.1186/cc4928 · Cited by 667
Self-citationAssessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616 · cited 1×
“The ability to update the Zt during each heart beat makes the system extremely reactive when abrupt changes in impedance occur (for example, changes in vascular tone) [36,37].”
BackgroundA Prospective, Randomized Study of Goal-Oriented Hemodynamic Therapy in Cardiac Surgical Patients
Pölönen, P., Ruokonen, E., Hippeläinen, M., Pöyhönen, M., & Takala, J. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200005000-00010 · Cited by 560 · cited 1×
“stay [82].”
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518 · cited 1×
“waveform (for example, severe arrhythmias and multiple ectopic beats) and inadequate response of fluid-filled transducer systems (that is, over- and under-damping) [28] can result in unreliable CO measurement.”
BackgroundReinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515 · cited 2×
“In shock states, therefore, ScvO2 may exceed SvO2 by up to 20% [72].”
BackgroundCritchley, L. A., Lee, A., & Ho, A. M.-H. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181f08a5b · Cited by 512 · cited 1×
“Not all monitoring devices have been evaluated against the same set of criteria, and uncertainty remains regarding acceptance thresholds for the performance of CO monitors and the used reference techniques [54-57].”
BackgroundEffects of maximizing oxygen delivery on morbidity and mortality in high-risk surgical patients
Lobo, S. M., Salgado, P. F., Castillo, V. G. T., Borim, A. A., Polachini, C., Palchetti, J. C., Brienzi, S. L. A., & de Oliveira, G. G. (2000) · Critical Care Medicine · doi:10.1097/00003246-200010000-00003 · Cited by 504
Legrand, M., Dupuis, C., Simon, C., Gayat, E., Mateo, J., Lukaszewicz, A.-C., & Payen, D. (2013) · Critical Care · doi:10.1186/cc13133 · Cited by 458 · cited 2×
“Thus, changes in CVP with concomitant CO variations give an indication of RV function and potential peripheral venous congestion, the latter of which is an important factor for organ perfusion [15].”
BackgroundSelf-citationPulmonary artery catheters for adult patients in intensive care
Rajaram, S. S., Desai, N. K., Kalra, A., Gajera, M., Cavanaugh, S. K., Brampton, W., Young, D., Harvey, S., & Rowan, K. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003408.pub3 · Cited by 446
Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007) · Critical Care · doi:10.1186/cc6117 · Cited by 442
Vincent, J.-L., & Weil, M. H. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000214677.76535.a5 · Cited by 424 · cited 1×
“Although changes in CVP correlate poorly with changes in CO [16] (as for pulmonary artery occlusion pressure), they can be used to assess the dynamic response to a fluid challenge [17] and to diagnose severe hypovolemia or cardiac dysfunction or both, especially where other monitoring systems are not available.”
BackgroundSelf-citationClinical review: Update on hemodynamic monitoring - a consensus of 16
Vincent, J.-L., Rhodes, A., Perel, A., Martin, G. S., Rocca, G., Vallet, B., Pinsky, M. R., Hofer, C. K., Teboul, J.-L., de Boode, W.-P., et al. (2011) · Critical Care · doi:10.1186/cc10291 · Cited by 419 · cited 1×
“Combining and integrating parameters from various hemodynamic monitoring systems may help improve our understanding of hemodynamic status [14].”
BackgroundSelf-citationCecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Self-citationCecconi, M., Corredor, C., Arulkumaran, N., Abuella, G., Ball, J., Grounds, R. M., Hamilton, M., & Rhodes, A. (2012) · Critical Care · doi:10.1186/cc11823 · Cited by 339 · cited 1×
“sufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications and poor outcomes [6-9].”
BackgroundSelf-citationDonati, A., Loggi, S., Preiser, J.-C., Orsetti, G., Münch, C., Gabbanelli, V., Pelaia, P., & Pietropaoli, P. (2007) · Chest · doi:10.1378/chest.07-0621 · Cited by 320
Noninvasive cardiac output monitoring (NICOM): a clinical validation
Squara, P., Denjean, D., Estagnasie, P., Brusset, A., Dib, J. C., & Dubois, C. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0640-0 · Cited by 320 · cited 1×
“This technique may be somewhat superior to the bioimpedance technique [51,52] but is dependent on body size [53] and the aeration of the lung.”
MethodMonnet, X., & Teboul, J.-L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0994-y · Cited by 317 · cited 1×
“It is obviously impractical during most operative conditions [68].”
BackgroundMcKendry, M., McGloin, H., Saberi, D., Caudwell, L., Brady, A. R., & Singer, M. (2004) · BMJ · doi:10.1136/bmj.38156.767118.7c · Cited by 315 · cited 1×
“There is good evidence that use of flow-based hemodynamic monitoring combined with hemodynamic manipulation in the perioperative period can reduce morbidity and sometimes mortality [83,91-97].”
BackgroundCannesson, M., Pestel, G., Ricks, C., Hoeft, A., & Perel, A. (2011) · Critical Care · doi:10.1186/cc10364 · Cited by 310 · cited 2×
“America [19] (Table 1).”
Self-citationMeregalli, A., Oliveira, R. P., & Friedman, G. (2004) · Critical Care · doi:10.1186/cc2423 · Cited by 294 · cited 1×
“Hyperlactatemia is associated with increased morbidity and mortality in critically ill patients [87-90].”
BackgroundA randomised, controlled trial of the pulmonary artery catheter in critically ill patients
Rhodes, A., Cusack, R. J., Newman, P. J., Grounds, M. R., & Bennett, D. E. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1206-9 · Cited by 281 · cited 1×
“Though criticized in recent years for its intrinsic invasiveness and no clear evidence of improved outcomes [22-25], the pulmonary artery catheter (PAC) is the only tool that provides continuous monitoring of pulmonary artery pressure, right-sided and left-sided filling pressures, CO, and mixed venous oxygen saturatio…”
BackgroundSelf-citationJhanji, S., Thomas, B., Ely, A., Watson, D., Hinds, C. J., & Pearse, R. M. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2008.05560.x · Cited by 259 · cited 1×
“Although less than 15% of inpatient procedures are performed in high-risk patients, such patients account for 80% of deaths [2-4].”
BackgroundSelf-citationMonitoring of peri‐operative fluid administration by individualized goal‐directed therapy
Bundgaard‐Nielsen, M., Holte, K., Secher, N. H., & Kehlet, H. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01221.x · Cited by 250
Gurgel, S. T., & do Nascimento, P. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182055384 · Cited by 246 · cited 1×
“sufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications and poor outcomes [6-9].”
BackgroundJhanji, S., Lee, C. D., Watson, D. I., Hinds, C., & Pearse, R. M. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1325-z · Cited by 240 · cited 1×
“sufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications and poor outcomes [6-9].”
BackgroundSelf-citationMulticenter Evaluation of Noninvasive Cardiac Output Measurement by Bioreactance Technique
Raval, N. Y., Squara, P., Cleman, M., Yalamanchili, K., Winklmaier, M., & Burkhoff, D. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9112-5 · Cited by 229 · cited 1×
“This technique may be somewhat superior to the bioimpedance technique [51,52] but is dependent on body size [53] and the aeration of the lung.”
MethodEarly Goal-Directed Therapy after Major Surgery Reduces Complications and Duration of Hospital Stay
Elliott, D. (2006) · Journal of the Intensive Care Society · doi:10.1177/175114370600700123 · Cited by 223
Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., & Boerner, U. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00007 · Cited by 216 · cited 2×
“Although the determinants of ScvO2 and SvO2 are similar, they cannot be used interchangeably [70-73].”
BackgroundPulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular disease
Bogert, L. W. J., Wesseling, K. H., Schraa, O., Van Lieshout, E. J., De Mol, B. A. J. M., Van Goudoever, J., Westerhof, B. E., & Van Lieshout, J. J. (2010) · Anaesthesia · doi:10.1111/j.1365-2044.2010.06511.x · Cited by 202 · cited 11×
“CO, cardiac output; PAC, pulmonary artery catheter; PPV, pulse pressure variation; ScvO2, central venous oxygen saturation.”
ResultInfluentialLack of Equivalence Between Central and Mixed Venous Oxygen Saturation
Chawla, L. S., Zia, H., Gutierrez, G., Katz, N. M., Seneff, M. G., & Shah, M. (2004) · Chest · doi:10.1378/chest.126.6.1891 · Cited by 198 · cited 16×
“Though criticized in recent years for its intrinsic invasiveness and no clear evidence of improved outcomes [22-25], the pulmonary artery catheter (PAC) is the only tool that provides continuous monitoring of pulmonary artery pressure, right-sided and left-sided filling pressures, CO, and mixed venous oxygen saturatio…”
BackgroundInfluentialHamzaoui, O., Monnet, X., Richard, C., Osman, D., Chemla, D., & Teboul, J.-L. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.ob013e318161fec4 · Cited by 179 · cited 1×
“The system has to be frequently recalibrated, at least every 8 hours in hemodynamically stable patients and more often if changes in vasoactive support are provided [29].”
BackgroundJansen, T. C., van Bommel, J., Woodward, R., Mulder, P. G. H., & Bakker, J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a0f919 · Cited by 177
Goepfert, M. S., Richter, H. P., zu Eulenburg, C., Gruetzmacher, J., Rafflenbeul, E., Roeher, K., von Sandersleben, A., Diedrichs, S., Reichenspurner, H., Goetz, A. E., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31829bd770 · Cited by 177 · cited 1×
“Several studies have indicated that fluid management based on PPV, SVV, and SV optimization may decrease post-operative wound infections and possibly post-operative organ dysfunction [99,100].”
BackgroundBarratt‐Boyes, B. G., & Wood, E. H. (1957) · PubMed · Cited by 175
Goal-directed haemodynamic therapy during elective total hip arthroplasty under regional anaesthesia
Cecconi, M., Fasano, N., Langiano, N., Divella, M., Costa, M. G., Rhodes, A., & Rocca, G. D. (2011) · Critical Care · doi:10.1186/cc10246 · Cited by 172 · cited 1×
“The FloTracTM/VigileoTM system has been shown to be suitable for integration into perioperative optimization protocols, resulting in improved clinical outcomes [34,35].”
MethodSelf-citationLactate as a hemodynamic marker in the critically ill
Fuller, B. M., & Dellinger, R. P. (2012) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283532b8a · Cited by 169 · cited 1×
“The net flux of lactate depends on the difference between release and uptake and varies among organs and with their energetic conditions [86].”
BackgroundCentral Venous Oxygen Saturation in Shock: A Study in Man
Lee, J., Wright, F., Barber, R., & Stanley, L. (1972) · Anesthesiology · doi:10.1097/00000542-197205000-00012 · Cited by 165 · cited 1×
“In healthy individuals, ScvO2 may be slightly less than SvO2 [75] because of the high oxygen content of effluent venous blood from the kidneys [76], but this relationship is reversed during periods of hemodynamic instability as blood is redistributed to the upper body at the expense of the splanchnic and renal circula…”
BackgroundMahjoub, Y., Lejeune, V., Müller, L., Perbet, S., Zieleskiewicz, L., Bart, F., Veber, B., Paugam‐Burtz, C., Jaber, S., Ayham, A., et al. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet442 · Cited by 163 · cited 1×
“Nevertheless, in the ICU, a relatively small proportion of patients present suitable criteria for these indices [63].”
BackgroundScheeren, T. W. L., Wiesenack, C., Gerlach, H., & Marx, G. (2013) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-013-9461-6 · Cited by 162 · cited 1×
“Several studies have indicated that fluid management based on PPV, SVV, and SV optimization may decrease post-operative wound infections and possibly post-operative organ dysfunction [99,100].”
BackgroundThiele, R. H., Bartels, K., & Gan, T. J. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000608 · Cited by 156 · cited 2×
“All monitoring systems have unique characteristics in terms of accuracy, precision, validity, stability, and reliability [18].”
BackgroundMethodFellahi, J.-L., Parienti, J., Hanouz, J., Plaud, B., Riou, B., & Ouattara, A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318173026f · Cited by 144 · cited 1×
“There is a risk of overtreatment as excessive use of dobutamine has been associated with increased rates of complications [101].”
BackgroundSandroni, C., Cavallaro, F., Marano, C., Falcone, C., Santis, P. D., & Antonelli, M. M. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2621-1 · Cited by 134 · cited 1×
“striction with or without the use of vasopressors [60-62].”
BackgroundSquara, P., Cecconi, M., Rhodes, A., Singer, M., & Chiche, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1570-9 · Cited by 133 · cited 1×
“Not all monitoring devices have been evaluated against the same set of criteria, and uncertainty remains regarding acceptance thresholds for the performance of CO monitors and the used reference techniques [54-57].”
BackgroundSelf-citationThe pulmonary artery catheter: In medio virtus
Vincent, J., Pinsky, M. R., Sprung, C. L., Levy, M. M., Marini, J. J., Payen, D. M., Rhodes, A., & Takala, J. A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818c10c7 · Cited by 126 · cited 1×
“Although the PAC can now be largely replaced by less invasive hemodynamic monitoring techniques in many cases, in some complex clinical situations (for example, cardiac surgery, organ transplant surgery, and surgery associated with major fluid shifts or high risk of respiratory failure or in patients with compromised…”
MethodSelf-citationCriteria for set point estimation in the volume clamp method of blood pressure measurement.
Peňáz, J. (1992) · PubMed · Cited by 122
Collaborative Study Group on Perioperative ScvO2 Monitoring (2006) · Critical Care · doi:10.1186/cc5094 · Cited by 120
Stover, J., Stocker, R. A., Lenherr, R., Neff, T. A., Cottini, S. R., Zoller, B., & Béchir, M. (2009) · BMC Anesthesiology · doi:10.1186/1471-2253-9-6 · Cited by 112 · cited 11×
“CO, cardiac output; PAC, pulmonary artery catheter; PPV, pulse pressure variation; ScvO2, central venous oxygen saturation.”
ResultInfluentialCentral mixed and splanchnic venous oxygen saturation monitoring
Dahn, M. S., Lange, M. P., & Jacobs, L. A. (1988) · Intensive Care Medicine · doi:10.1007/bf00262891 · Cited by 109 · cited 1×
“In healthy individuals, ScvO2 may be slightly less than SvO2 [75] because of the high oxygen content of effluent venous blood from the kidneys [76], but this relationship is reversed during periods of hemodynamic instability as blood is redistributed to the upper body at the expense of the splanchnic and renal circula…”
BackgroundPerz, S., Uhlig, T., Kohl, M., Bredle, D. L., Reinhart, K., Bauer, M. W., & Kortgen, A. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1980-8 · Cited by 109 · cited 1×
“At the same time, very high ScvO2 values may imply that oxygen extraction is low, purporting a worse prognosis, at least during cardiac surgery [85].”
BackgroundBubenek-Turconi, S. I., Crăciun, M., Miclea, I., & Perel, A. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31829562c3 · Cited by 108 · cited 11×
“CO, cardiac output; PAC, pulmonary artery catheter; PPV, pulse pressure variation; ScvO2, central venous oxygen saturation.”
ResultInfluentialSelf-citationCecconi, M., Dawson, D., Grounds, R. M., & Rhodes, A. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1292-4 · Cited by 99 · cited 1×
“It has been validated in critically ill patients [32,33].”
BackgroundSelf-citationPulmonary Artery Catheters for Adult Patients in Intensive Care
Harvey, S. E., Young, D., Brampton, W., Cooper, A. B., Doig, G. S., Sibbald, W. J., & Rowan, K. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246792.19389.cf · Cited by 81
Comparison of a supra-sternal cardiac output monitor (USCOM) with the pulmonary artery catheter
Thom, O., Taylor, D. M., Wolfe, R. E., Cade, J. F., Myles, P. S., Krum, H., & Wolfe, R. S. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep296 · Cited by 73 · cited 1×
“Clinical validation studies have shown conflicting results, partially due to variations in signal acquisition inherent in the technique [45].”
Assessment of left ventricular function by pulse wave analysis in critically ill patients
Scolletta, S., Bodson, L., Donadello, K., Taccone, F. S., Devigili, A., Vincent, J., & Backer, D. D. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2861-8 · Cited by 72 · cited 1×
“The ability to update the Zt during each heart beat makes the system extremely reactive when abrupt changes in impedance occur (for example, changes in vascular tone) [36,37].”
BackgroundSelf-citationUsing ventilation-induced plethysmographic variations to optimize patient fluid status
Desebbe, O., & Cannesson, M. P. (2008) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32831504ca · Cited by 70 · cited 1×
“Respiratory variations in the pulse oximeter plethysmographic waveform have been shown to predict fluid responsiveness in mechanically ventilated patients, similar to changes in the arterial pressure waveform [59].”
BackgroundGujjar, A. R., Muralidhar, K., Banakal, S. K., Gupta, R., Sathyaprabha, T. N., & Jairaj, P. S. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9119-y · Cited by 68
Oren-Grinberg, A. (2009) · International Anesthesiology Clinics · doi:10.1097/aia.0b013e3181c3dc11 · Cited by 65
Pearse, R. M., Belsey, J., Cole, J. N., & Bennett, E. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816a091b · Cited by 64
Self-citationBendjelid, K., Marx, G., Kiefer, N., Simon, T. P., Geisen, M., Hoeft, A., Siegenthaler, N., & Hofer, C. K. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet116 · Cited by 60 · cited 1×
“It has been validated against the PiCCOTM and transpulmonary thermodilution in critically ill patients [31].”
MethodSelf-citationKulemann, B., Timme, S., Seifert, G. J., Holzner, P. A., Glatz, T., Sick, O., Chikhladze, S., Bronsert, P., Hoeppner, J., Werner, M., et al. (2013) · Surgery · doi:10.1016/j.surg.2013.04.010 · Cited by 60 · cited 1×
“Thus, effective fluid management to prevent and treat hypo/hypervolemia and titration of vasoactive drugs for heart dysfunction are crucial to maintain adequate oxygen delivery (DO2) and prevent fluid overload and its consequences [10-12].”
BackgroundClinical review: What are the best hemodynamic targets for noncardiac surgical patients?
Lobo, S. M., & de Oliveira, N. E. (2013) · Critical Care · doi:10.1186/cc11861 · Cited by 59
A Comparison of Central and Mixed Venous Oxygen Saturation in Circulatory Failure
Ho, K. M., Harding, R., Chamberlain, J., & Bulsara, M. K. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2007.10.011 · Cited by 53 · cited 16×
“Though criticized in recent years for its intrinsic invasiveness and no clear evidence of improved outcomes [22-25], the pulmonary artery catheter (PAC) is the only tool that provides continuous monitoring of pulmonary artery pressure, right-sided and left-sided filling pressures, CO, and mixed venous oxygen saturatio…”
BackgroundInfluentialLorentzen, A.-G., Lindskov, C., Sloth, E., & Jakobsen, C.-J. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2008.04.004 · Cited by 49 · cited 16×
“Though criticized in recent years for its intrinsic invasiveness and no clear evidence of improved outcomes [22-25], the pulmonary artery catheter (PAC) is the only tool that provides continuous monitoring of pulmonary artery pressure, right-sided and left-sided filling pressures, CO, and mixed venous oxygen saturatio…”
BackgroundInfluentialEffects of propofol, etomidate, and pentobarbital on critical oxygen delivery
der Linden, P. V., Schmartz, D., Gilbart, E., Engelman, E. E., & Vincent, J. (2000) · Critical Care Medicine · doi:10.1097/00003246-200007000-00051 · Cited by 36
Self-citationOesophageal Doppler monitoring, doubt and equipoise: evidence based medicine means change
Morris, C. (2013) · Anaesthesia · doi:10.1111/anae.12306 · Cited by 34 · cited 1×
“For a variety of reasons, however, this approach has not been adopted everywhere and has even been challenged [98].”
Cardiac output measurements in off-pump coronary surgery
Guéret, G., Kiss, G., Rossignol, B., Bezon, E., Wargnier, J. P., Miossec, A., Corre, O., & Arvieux, C. C. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506000573 · Cited by 32 · cited 1×
“The system is not really clinically acceptable, because the assessment of CO is possible only in patients with fixed ventilator settings and good respiratory function with no relevant pulmonary shunt [46,47].”
BackgroundComparison of the Endotracheal Cardiac Output Monitor to Thermodilution in Cardiac Surgery Patients
Ball, T. R., Culp, B. C., Patel, V. B., et al. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.04.008 · Cited by 31 · cited 1×
“The reliability of these systems is poor [49,50].”
BackgroundGaristo, C., Favia, I., Ricci, Z., Romagnoli, S., Haiberger, R., Polito, A., & Cogo, P. E. (2014) · Pediatric Anesthesia · doi:10.1111/pan.12360 · Cited by 24 · cited 1×
“This technique may be somewhat superior to the bioimpedance technique [51,52] but is dependent on body size [53] and the aeration of the lung.”
Self-citationHypotension during gradual blood loss: waveform variables response and absence of tachycardia
Pizov, R., Eden, A., Bystritski, D., Kalina, E., Tamir, A., & Gelman, S. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes300 · Cited by 21 · cited 1×
“Similarly, heart rate may fail to reflect the development of hypovolemia under anesthesia [13].”
BackgroundDoppler echocardiography in shocked patients
Repessé, X., Bodson, L., & Vieillard‐Baron, A. (2013) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283602344 · Cited by 10 · cited 1×
“(usually easier with TEE than with TTE), Doppler echocardiographic examination can provide an indication of cardiac function because it allows visualization of the cardiac chambers, valves, and pericardium [20].”
Background
Cited by
Futier, E., Lefrant, J.-Y., Guinot, P.-G., Godet, T., Lorne, E., Cuvillon, P., Bertran, S., Leone, M., Pastene, B., Piriou, V., et al. (2017) · JAMA · doi:10.1001/jama.2017.14172 · Cited by 917
Mechanisms and treatment of organ failure in sepsis
Lelubre, C., & Vincent, J.-L. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0005-7 · Cited by 852
Self-citationLess invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationA rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Kwon, K., Kim, J. U., Won, S. M., Zhao, J., Avila, R., Wang, H., Chun, K. S., Jang, H., Lee, K. H., Kim, J.-H., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01022-4 · Cited by 217
Metadata
- Authors
- Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., Rocca, G. D., & Rhodes, A.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 224-224
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2135528075
- Cited by
- 243
- References
- 87
- FWCI
- 22.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.