BACKGROUND: In critically ill patients, changes in the velocity-time integral (VTI) of the left ventricular outflow tract, measured by transthoracic echocardiography (TTE), are often used to non-invasively assess the response to fluid administration or for performing tests assessing fluid responsiveness. However, the precision of TTE measurements has not yet been investigated in such patients. First, we aimed at assessing how many measurements should be averaged within one TTE examination to reach a sufficient precision for various variables. Second, we aimed at identifying the least significant change (LSC) of these variables between successive TTE examinations. METHODS: We prospectively included 100 haemodynamically stable patients in whom TTE examination was planned. Three TTE examinations were performed, the first and the third by one operator and the second by another one. We calculated the precision and LSC (1) within one examination depending on the number of averaged measurements and (2) between measurements performed in two successive examinations. RESULTS: In patients in sinus rhythm, averaging three measurements within an examination was enough for obtaining an acceptable precision (interquartile range highest value < 10%) for VTI. In patients with atrial fibrillation, averaging five measurements was necessary. The precision of some other common TTE variables depending on the number of measurements is provided. Between two successive examinations performed by the same operator, the LSC was 11 [5-18]% for VTI. If two operators performed the examinations, the LSC for VTI significantly increased to 14 [8-26]%. The LSC between two examinations for other TTE variables is also provided. CONCLUSIONS: Averaging three measurements within one TTE examination is enough for obtaining precise measurements for VTI in patients in sinus rhythm but not in patients with atrial fibrillation. Between two TTE examinations performed by the same operator, the LSC of VTI is compatible with the assessment of the effects of a 500-mL fluid infusion but is not precise enough for assessing the effects of some tests predicting preload responsiveness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362 · cited 1×
“Current recommendations are to average measurements over a minimum of five cycles [18] or over ten cycles [20] in case of atrial fibrillation.”
BackgroundLang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262 · cited 1×
“Current recommendations are to average measurements over a minimum of five cycles [18] or over ten cycles [20] in case of atrial fibrillation.”
BackgroundRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew082 · Cited by 2,425
Cecconi, M., De Backer, D., Antonelli, M., Beale, R., Bakker, J., Hofer, C., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J. L., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,767
Self-citationVincent, J.-L., & De Backer, D. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208943 · Cited by 1,425
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Self-citationFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citationPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Self-citationPassive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482
Self-citationEvangelista, A., Flachskampf, F., Lancellotti, P., Badano, L., Aguilar, R., Monaghan, M., Zamorano, J., Nihoyannopoulos, P., & on behalf of the European Association of Echocardiography (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jen174 · Cited by 404
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Self-citationCecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Less invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationMonnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Self-citationDiagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Monitoring Skeletal Changes by Radiological Techniques
Glüer, C.-C. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.11.1952 · Cited by 244
Assessing observer variability: a user’s guide
Popović, Z. B., & Thomas, J. D. (2017) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.03.12 · Cited by 225
Precision of the transpulmonary thermodilution measurements
Monnet, X., Persichini, R., Ktari, M., Jozwiak, M., Richard, C., & Teboul, J.-L. (2011) · Critical Care · doi:10.1186/cc10421 · Cited by 194
Self-citationLancellotti, P., Price, S., Edvardsen, T., Cosyns, B., Neskovic, A. N., Dulgheru, R., Flachskampf, F. A., Hassager, C., Pasquet, A., Gargani, L., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu210 · Cited by 182
Galderisi, M., Henein, M. Y., D'hooge, J., Sicari, R., Badano, L. P., Zamorano, J. L., Roelandt, J. R. T. C., & on behalf of the European Association of Echocardiography (2011) · European Journal of Echocardiography · doi:10.1093/ejechocard/jer051 · Cited by 164
Squara, P., Cecconi, M., Rhodes, A., Singer, M., & Chiche, J. (2009) · Intensive Care Medicine · doi:10.1007/s00134-009-1570-9 · Cited by 133
Jozwiak, M., Dépret, F., Teboul, J., Alphonsine, J.-E., Lai, C., Richard, C., & Monnet, X. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002704 · Cited by 112
Self-citationCharbonneau, H., Riu, B., Faron, M., Mari, A., Kurrek, M. M., Ruiz, J., Geeraerts, T., Fourcade, O. A., Genestal, M., & Silva, S. (2014) · Critical Care · doi:10.1186/s13054-014-0473-5 · Cited by 97
Reproducibility of bone mineral density measurement in daily practice
Lodder, M. C., Lems, W. F., Adèr, H. J., Marthinsen, A. E., van Coeverden, S. C. C. M., Lips, P. T. A. M., Netelenbos, J. C., Dijkmans, B. A. C., & Roos, J. C. (2004) · Annals of the Rheumatic Diseases · doi:10.1136/ard.2002.005678 · Cited by 97
Pearls and pitfalls in comprehensive critical care echocardiography
Orde, S. R., Slama, M., Hilton, A. K., Yastrebov, K., & McLean, A. S. (2017) · Critical Care · doi:10.1186/s13054-017-1866-z · Cited by 96
Mini-fluid Challenge of 100 ml of Crystalloid Predicts Fluid Responsiveness in the Operating Room
Biais, M., de Courson, H., Lanchon, R., Pereira, B., Bardonneau, G., Griton, M., Sesay, M., & Nouette-Gaulain, K. (2017) · Anesthesiology · doi:10.1097/aln.0000000000001753 · Cited by 94 · cited 1×
“By contrast, the VTI LSC is larger than the diagnostic threshold of VTI changes found for fluid challenges smaller than 100 mL [32], or for the end-expiratory occlusion test [11, 31, 33].”
MethodGeorges, D., de Courson, H., Lanchon, R., Sesay, M., Nouette‐Gaulain, K., & Biais, M. (2018) · Critical Care · doi:10.1186/s13054-017-1938-0 · Cited by 73
Biais, M., Larghi, M., Henriot, J., de Courson, H., Sesay, M., & Nouette‐Gaulain, K. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002322 · Cited by 65 · cited 2×
“By contrast, the VTI LSC is larger than the diagnostic threshold of VTI changes found for fluid challenges smaller than 100 mL [32], or for the end-expiratory occlusion test [11, 31, 33].”
BackgroundMethodGuinot, P., Zogheib, E. H., Detave, M., Moubarak, M., Hubert, V., Badoux, L., Bernard, E., Besserve, P., Caus, T., & Dupont, H. (2011) · Critical Care · doi:10.1186/cc10451 · Cited by 54
Variability in echocardiographic measurements of left ventricular function in septic shock patients
Geer, L. D., Oscarsson, A., & Engvall, J. E. (2015) · Cardiovascular Ultrasound · doi:10.1186/s12947-015-0015-6 · Cited by 53
Sumida, T., Tanabe, K., Yagi, T., Kawai, J., Konda, T., Fujii, Y., Okada, M., Yamaguchi, K., Tani, T., & Morioka, S. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00275-x · Cited by 47
Wang, C., Lin, K., Luqman, N., Ho, W., Hsu, L., Chu, P., & Kuo, C.-T. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.03.001 · Cited by 14
Cited by
Prediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
Self-citationHow can assessing hemodynamics help to assess volume status?
De Backer, D., Aissaoui, N., Cecconi, M., Chew, M. S., Denault, A., Hajjar, L., Hernandez, G., Messina, A., Myatra, S. N., Ostermann, M., et al. (2022) · Intensive Care Medicine · doi:10.1007/s00134-022-06808-9 · Cited by 199
“Indeed, the changes in CO during PLR should be larger than the least significant change of the technique [52].”
BackgroundSelf-citationManagement of sepsis and septic shock in the emergency department
Gavelli, F., Castello, L. M., & Avanzi, G. C. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-021-02735-7 · Cited by 161
“CO can be assessed by evaluating relative changes in the velocity–time integral (VTI) of the left ventricular outflow tract [63].”
BackgroundMethod
Metadata
- Authors
- Jozwiak, M., Mercado, P., Teboul, J.-L., Benmalek, A., Gimenez, J., Dépret, F., Richard, C., & Monnet, X.
- Venue
- Critical Care
- Published
- 2019-04-11
- Volume
- 23
- Issue
- 1
- Pages
- 116-116
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2944929594
- Cited by
- 177
- References
- 36
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.