CoChat

Autonomous and Continuous Adaptation of a Bihormonal Bionic Pancreas in Adults and Adolescents With Type 1 Diabetes

Open access
El-Khatib, Firas H., Russell, Steven J., Magyar, Kendra L., Sinha, Manasi, McKeon, Katherine, Nathan, David M., Damiano, Edward R. · 2014 · The Journal of Clinical Endocrinology & Metabolism
Cited by 122

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Context: A challenge for automated glycemic control in type 1 diabetes (T1D) is the large variation in insulin needs between individuals and within individuals at different times in their lives. Objectives: The objectives of the study was to test the ability of a third-generation bihormonal bionic pancreas algorithm, initialized with only subject weight; to adapt automatically to the different insulin needs of adults and adolescents; and to evaluate the impact of optional, automatically adaptive meal-priming boluses. Design: This was a randomized controlled trial. Setting: The study was conducted at an inpatient clinical research center. Patients: Twelve adults and 12 adolescents with T1D participated in the study. Interventions: Subjects in each age group were randomized to automated glycemic control for 48 hours with or without automatically adaptive meal-priming boluses. Main Outcome Measures: Mean plasma glucose (PG), time with PG less than 60 mg/dL, and insulin total daily dose were measured. Results: The 48-hour mean PG values with and without adaptive meal-priming boluses were 132 ± 9 vs 146 ± 9 mg/dL (P = .03) in adults and 162 ± 6 vs 175 ± 9 mg/dL (P = .01) in adolescents. Adaptive meal-priming boluses improved mean PG without increasing time spent with PG less than 60 mg/dL: 1.4% vs 2.3% (P = .6) in adults and 0.1% vs 0.1% (P = 1.0) in adolescents. Large increases in adaptive meal-priming boluses and shifts in the timing and size of automatic insulin doses occurred in adolescents. Much less adaptation occurred in adults. There was nearly a 4-fold variation in the total daily insulin dose across all cohorts (0.36–1.41 U/kg · d). Conclusions: A single control algorithm, initialized only with subject weight, can quickly adapt to regulate glycemia in patients with TID and highly variable insulin requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1210/jc.2013-4151

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 122

Metadata

Authors
El-Khatib, F. H., Russell, S. J., Magyar, K. L., Sinha, M., McKeon, K., Nathan, D. M., & Damiano, E. R.
Venue
The Journal of Clinical Endocrinology & Metabolism
Published
2014-05-01
Volume
99
Issue
5
Pages
1701-1711
ISSN
  • 0021-972X (ISSN-L)
  • 1945-7197
OpenAlex
W2023675073
Cited by
122
References
16
FWCI
13.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.