CoChat

Predictive Accuracy of Surrogate Indices for Hepatic and Skeletal Muscle Insulin Sensitivity

Open access

The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index.

Abstract

Surrogate indices of muscle and hepatic insulin sensitivity derived from an oral glucose tolerance test (OGTT) are frequently used in clinical studies. However, the predictive accuracy of these indices has not been validated. In this cross-sectional study, hyperinsulinemic-euglycemic glucose clamp with tritiated glucose infusion and a 75-g OGTT were performed in individuals (n = 659, aged 18 to 49 years, body mass index of 16 to 64 kg/m2) with varying degrees of glucose tolerance. A calibration model was used to assess the ability of OGTT-derived, tissue-specific surrogate indices [hepatic insulin resistance index (HIRI) and muscle insulin sensitivity index (MISI)] to predict insulin sensitivity/resistance indices derived from the reference glucose clamp [Hepatic-IRbasal, a product of fasting plasma insulin and hepatic glucose production (HGP), Hepatic-IRclamp, reciprocal of the percent suppression of HGP during the insulin clamp corrected for plasma insulin concentration, and Muscle-ISclamp, a measure of peripheral glucose disposal]. Predictive accuracy was assessed by root mean squared error of prediction and leave-one-out, cross-validation-type square root of the mean squared error of prediction. HIRI and MISI were correlated with their respective clamp-derived indices. HIRI was negatively related to Muscle-ISclamp (r = –0.62, P < 0.0001) and MISI correlated with Hepatic-IR derived from the clamp (Hepatic-IRbasal: r = –0.48, P < 0.0001 and Hepatic-IRclamp: r = –0.41, P < 0.0001). However, the accuracy of HIRI and MISI to predict Hepatic-IR (basal or during clamp) was not significantly different. Likewise, the ability of HIRI and MISI to predict Muscle-ISclamp was also similar. Our findings indicate that the surrogate indices derived from an OGTT are accurate in predicting insulin sensitivity but are not tissue specific.

Overview

Integrity signals

Registry

Crossref · 10.1210/js.2018-00206

Cites

45 of 45 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 16

Metadata

Authors
Muniyappa, R., Tella, S. H., Sortur, S., Mszar, R., Grewal, S., Abel, B. S., Auh, S., Chang, D. C., Krakoff, J., & Skarulis, M. C.
Affiliations
National Institutes of Health (US)
Corresponding author
Muniyappa, Ranganath
Venue
Journal of the Endocrine Society
Published
2018-09-25
Volume
3
Issue
1
Pages
108-118
ISSN
2472-1972 (ISSN-L)
OpenAlex
W2894010512
Cited by
16
References
46
Citations by year
2026: 2 · 2025: 3 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 4 · 2020: 2
FWCI
1.19
Type
journal article
Language
en
Open access
Licence
public-domain
Locations
  • Journal of the Endocrine Society (publishedVersion, public-domain)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
Keywords
insulin sensitivity, hepatic insulin resistance, skeletal muscle insulin sensitivity, surrogate indices, oral glucose tolerance test, hepatic glucose production, prediction accuracy, calibration models, glucose tolerance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.