Contrast letter acuity as a visual component for the Multiple Sclerosis Functional Composite
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Visual dysfunction is one of the most common causes of disability in multiple sclerosis (MS). The Multiple Sclerosis Functional Composite (MSFC), a new clinical trial outcome measure, does not currently include a test of visual function. OBJECTIVE: To examine contrast letter acuity as a candidate visual function test for the MSFC. METHODS: Binocular contrast letter acuity testing (Sloan charts) was performed in a subgroup of participants from the International Multiple Sclerosis Secondary Progressive Avonex Controlled Trial (IMPACT Substudy) and in MS patients and disease-free control subjects from a cross-sectional study of visual outcome measures (Multiple Sclerosis Vision Prospective cohort [MVP cohort]). High-contrast visual acuity was measured in both studies; MVP cohort participants underwent additional binocular testing for contrast sensitivity (Pelli-Robson chart), color vision (D-15 desaturated test), and visual field (Esterman test, Humphrey Field Analyzer II). RESULTS: Contrast letter acuity (Sloan charts, p < 0.0001, receiver operating characteristic curve analysis) and contrast sensitivity (Pelli-Robson chart, p = 0.003) best distinguished MS patients from disease-free control subjects in the MVP cohort. Correlations of Sloan chart scores with MSFC and Expanded Disability Statue Scale (EDSS) scores in both studies were significant and moderate in magnitude, demonstrating that Sloan chart scores reflect visual and neurologic dysfunction not entirely captured by the EDSS or MSFC. CONCLUSIONS: Among clinical measures, contrast letter acuity (Sloan charts) and contrast sensitivity (Pelli-Robson chart) demonstrate the greatest capacity to identify binocular visual dysfunction in MS. Sloan chart testing also captures unique aspects of neurologic dysfunction not captured by current EDSS or MSFC components, making it a strong candidate visual function test for the MSFC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011
New Visual Acuity Charts for Clinical Research
Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982) · American Journal of Ophthalmology · doi:10.1016/0002-9394(82)90197-0 · Cited by 2,142
New Design Principles for Visual Acuity Letter Charts
Bailey, I. L., & Lovie, J. E. (1976) · American journal of optometry and physiological optic · doi:10.1002/j.2330-9512.1976.tb02218.x · Cited by 1,407
THE DESIGN OF A NEW LETTER CHART FOR MEASURING CONTRAST SENSITIVITY
Pelli, D. G., Robson, J. G., & Wilkins, A. J. (1988) · Cited by 1,308
Development of a multiple sclerosis functional composite as a clinical trial outcome measure
Cutter, G. R. (1999) · Brain · doi:10.1093/brain/122.5.871 · Cited by 1,190
Self-citationWest, S. K., Muñoz, B., Rubin, G. S., Schein, O. D., Bandeen‐Roche, K., Zeger, S. L., German, S., & Fried, L. P. (1997) · PubMed · Cited by 490
Benefit of interferon β-1a on MSFC progression in secondary progressive MS
Cohen, J. A., Cutter, G. R., Fischer, J. S., Goodman, A. D., Heidenreich, F. R., Kooijmans, M. F., Sandrock, A. W., Rudick, R. A., Simon, J. H., Simonian, N. A., et al. (2002) · Neurology · doi:10.1212/wnl.59.5.679 · Cited by 402
Self-citationRecommendations from the national multiple sclerosis society clinical outcomes assessment task force
Rudick, R., Antel, J., Confavreux, C., Cutter, G., Ellison, G., Fischer, J., Lublin, F., Miller, A., Petkau, J., Rao, S., et al. (1997) · Annals of Neurology · doi:10.1002/ana.410420318 · Cited by 371
Self-citationVisual Impairment and Disability in Older Adults
Rubin, G. S., Roche, K. B., PRASADA-RAO, P., & Fried, L. P. (1994) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1994.tb03438.x · Cited by 318
Cited by
Relation of Visual Function to Retinal Nerve Fiber Layer Thickness in Multiple Sclerosis
FISHER, J., JACOBS, D., MARKOWITZ, C., GALETTA, S., VOLPE, N., NANOSCHIAVI, M., BAIER, M., FROHMAN, E., WINSLOW, H., & FROHMAN, T. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2005.10.040 · Cited by 658
Self-citationMeyer-Moock, S., Feng, Y.-S., Maeurer, M., Dippel, F.-W., & Kohlmann, T. (2014) · BMC Neurology · doi:10.1186/1471-2377-14-58 · Cited by 639
Optical coherence tomography in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., de Boer, J. F., Schippling, S., Vermersch, P., Kardon, R., Green, A., Calabresi, P. A., & Polman, C. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70168-x · Cited by 596
Balcer, L. J. (2006) · New England Journal of Medicine · doi:10.1056/nejmcp053247 · Cited by 390
Self-citationLongitudinal study of vision and retinal nerve fiber layer thickness in multiple sclerosis
Talman, L. S., Bisker, E. R., Sackel, D. J., Long, D. A., Galetta, K. M., Ratchford, J. N., Lile, D. J., Farrell, S. K., Loguidice, M. J., Remington, G., et al. (2010) · Annals of Neurology · doi:10.1002/ana.22005 · Cited by 366
Self-citationOptical coherence tomography: a window into the mechanisms of multiple sclerosis
Frohman, E. M., Fujimoto, J. G., Frohman, T. C., Calabresi, P. A., Cutter, G., & Balcer, L. J. (2008) · Nature Clinical Practice Neurology · doi:10.1038/ncpneuro0950 · Cited by 326
Self-citationDiagnostic accuracy of retinal abnormalities in predicting disease activity in MS
Sepulcre, J., Murie-Fernandez, M., Salinas-Alaman, A., García-Layana, A., Bejarano, B., & Villoslada, P. (2007) · Neurology · doi:10.1212/01.wnl.0000260612.51849.ed · Cited by 298
Optical coherence tomography and disease subtype in multiple sclerosis
Pulicken, M., Gordon-Lipkin, E., Balcer, L. J., Frohman, E., Cutter, G., & Calabresi, P. A. (2007) · Neurology · doi:10.1212/01.wnl.0000294876.49861.dc · Cited by 298
Self-citationValidity of performance scales for disability assessment in multiple sclerosis
Marrie, R. A., & Goldman, M. (2007) · Multiple Sclerosis Journal · doi:10.1177/1352458507078388 · Cited by 285
The neuro-ophthalmology of multiple sclerosis
Frohman, E. M., Frohman, T. C., Zee, D. S., McColl, R., & Galetta, S. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)00992-0 · Cited by 285
Self-citationThe investigation of acute optic neuritis: a review and proposed protocol
Petzold, A., Wattjes, M. P., Costello, F., Flores-Rivera, J., Fraser, C. L., Fujihara, K., Leavitt, J., Marignier, R., Paul, F., Schippling, S., et al. (2014) · Nature Reviews Neurology · doi:10.1038/nrneurol.2014.108 · Cited by 270
Cohen, J. A., Reingold, S. C., Polman, C. H., & Wolinsky, J. S. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70059-5 · Cited by 233
Self-citationClinical trials in progressive multiple sclerosis: lessons learned and future perspectives
Ontaneda, D., Fox, R. J., & Chataway, J. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70264-9 · Cited by 220
Measuring Friedreich ataxia: Complementary features of examination and performance measures
Lynch, D. R., Farmer, J. M., Tsou, A. Y., Perlman, S., Subramony, S. H., Gomez, C. M., Ashizawa, T., Wilmot, G. R., Wilson, R. B., & Balcer, L. J. (2006) · Neurology · doi:10.1212/01.wnl.0000218155.46739.90 · Cited by 210
Self-citationVision and vision-related outcome measures in multiple sclerosis
Balcer, L. J., Miller, D. H., Reingold, S. C., & Cohen, J. A. (2015) · Brain · doi:10.1093/brain/awu335 · Cited by 209
“Addition of LCLA to the MSFC may increase sensitivity to changes in disability that are not detected by the original three-component MSFC (Balcer et al., 2003).”
InfluentialSelf-citationOutcome Measures in Clinical Trials for Multiple Sclerosis
van Munster, C. E. P., & Uitdehaag, B. M. J. (2017) · CNS Drugs · doi:10.1007/s40263-017-0412-5 · Cited by 196
“Of these, the low-contrast letter acuity test (LCLA, explained in Table 4) may be a good candidate to add to the MSFC [74].”
BackgroundOptical Coherence Tomography (OCT): Imaging the Visual Pathway as a Model for Neurodegeneration
Galetta, K. M., Calabresi, P. A., Frohman, E. M., & Balcer, L. J. (2011) · Neurotherapeutics · doi:10.1007/s13311-010-0005-1 · Cited by 185
“[62] and Baier et al.”
Self-citationOptical coherence tomography in multiple sclerosis
Frohman, E., Costello, F., Zivadinov, R., Stuve, O., Conger, A., Winslow, H., Trip, A., Frohman, T., & Balcer, L. (2006) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70573-7 · Cited by 175
Self-citationBalcer, L. J., Raynowska, J., Nolan, R., Galetta, S. L., Kapoor, R., Benedict, R., Phillips, G., LaRocca, N., Hudson, L., Rudick, R., et al. (2017) · Multiple Sclerosis Journal · doi:10.1177/1352458517690822 · Cited by 168
Self-citationRetinal nerve fiber layer thickness is associated with brain MRI outcomes in multiple sclerosis
Grazioli, E., Zivadinov, R., Weinstock-Guttman, B., Lincoff, N., Baier, M., Wong, J. R., Hussein, S., Cox, J. L., Hojnacki, D., & Ramanathan, M. (2008) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2007.10.020 · Cited by 168
“has been shown to have limited sensitivity for assessing visual function in MS patients [27].”
BackgroundSelf-citationLow-contrast letter acuity testing captures visual dysfunction in patients with multiple sclerosis
Baier, M. L., Cutter, G. R., Rudick, R. A., Miller, D., Cohen, J. A., Weinstock-Guttman, B., Mass, M., & Balcer, L. J. (2005) · Neurology · doi:10.1212/01.wnl.0000154521.40686.63 · Cited by 166
Self-citationDiagnosis and Management of Progressive Multiple Sclerosis
Macaron, G., & Ontaneda, D. (2019) · Biomedicines · doi:10.3390/biomedicines7030056 · Cited by 70
“Th l w contrast letter acuity testing using a low-contrast Sloan letter chart was later proposed as an additional compo ent of the MSFC to capture visual dysfunction with a high se sitivity, and also correlates with other compon nts of the MSFC and the EDSS [37,41,42].”
MethodOptic nerve diffusion tensor imaging after acute optic neuritis predicts axonal and visual outcomes
van der Walt, A., Kolbe, S. C., Wang, Y. E., Klistorner, A., Shuey, N., Ahmadi, G., Paine, M., Marriott, M., Mitchell, P., Egan, G. F., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0083825 · Cited by 48
“5%) viewed at 2m in a room well lit by white fluorescent lighting [18,19].”
Background
Metadata
- Authors
- Balcer, L. J., Baier, M. L., Cohen, J. A., Kooijmans, M. F., Sandrock, A. W., Nano–Schiavi, M. L., Pfohl, D. C., Mills, M., Bowen, J., Ford, C., Heidenreich, F. R., Jacobs, D. A., Markowitz, C. E., Stuart, W. H., Ying, G.-S., Galetta, S. L., Maguire, M. G., & Cutter, G. R.
- Venue
- Neurology
- Published
- 2003-11-25
- Volume
- 61
- Issue
- 10
- Pages
- 1367-1373
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W1996169066
- Cited by
- 193
- References
- 22
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.