The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
The APOSTEL recommendations for reporting quantitative optical coherence tomography studies
Open accessAbstract
OBJECTIVE: To develop consensus recommendations for reporting of quantitative optical coherence tomography (OCT) study results. METHODS: A panel of experienced OCT researchers (including 11 neurologists, 2 ophthalmologists, and 2 neuroscientists) discussed requirements for performing and reporting quantitative analyses of retinal morphology and developed a list of initial recommendations based on experience and previous studies. The list of recommendations was subsequently revised during several meetings of the coordinating group. RESULTS: We provide a 9-point checklist encompassing aspects deemed relevant when reporting quantitative OCT studies. The areas covered are study protocol, acquisition device, acquisition settings, scanning protocol, funduscopic imaging, postacquisition data selection, postacquisition data analysis, recommended nomenclature, and statistical analysis. CONCLUSIONS: The Advised Protocol for OCT Study Terminology and Elements recommendations include core items to standardize and improve quality of reporting in quantitative OCT studies. The recommendations will make reporting of quantitative OCT studies more consistent and in line with existing standards for reporting research in other biomedical areas. The recommendations originated from expert consensus and thus represent Class IV evidence. They will need to be regularly adjusted according to new insights and practices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citation(1985) · Archives of Ophthalmology · doi:10.1001/archopht.1985.01050120030015 · Cited by 2,540
A Randomized, Controlled Trial of Corticosteroids in the Treatment of Acute Optic Neuritis
Beck, R. W., Cleary, P. A., Anderson, M. M., Keltner, J. L., Shults, W. T., Kaufman, D. I., Buckley, E. G., Corbett, J. J., Kupersmith, M. J., Miller, N. R., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199202273260901 · Cited by 1,355
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
The OSCAR-IB Consensus Criteria for Retinal OCT Quality Assessment
Tewarie, P., Balk, L., Costello, F., Green, A., Martin, R., Schippling, S., & Petzold, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0034823 · Cited by 627
Self-citationRetinal Nerve Fiber Layer Measurements in Myopia: An Optical Coherence Tomography Study
Leung, C. K.-S., Mohamed, S., Leung, K. S., Cheung, C. Y.-L., Chan, S. L.-W., Cheng, D. K.-Y., Lee, A. K.-C., Leung, G. Y. S., Rao, S. K., & Lam, D. S. C. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0545 · Cited by 392
Primary retinal pathology in multiple sclerosis as detected by optical coherence tomography
Saidha, S., Syc, S. B., Ibrahim, M. A., Eckstein, C., Warner, C. V., Farrell, S. K., Oakley, J. D., Durbin, M. K., Meyer, S. A., Balcer, L. J., et al. (2011) · Brain · doi:10.1093/brain/awq346 · Cited by 333
Self-citationQuality control for retinal OCT in multiple sclerosis: validation of the OSCAR-IB criteria
Schippling, S., Balk, L., Costello, F., Albrecht, P., Balcer, L., Calabresi, P., Frederiksen, J., Frohman, E., Green, A., Klistorner, A., et al. (2015) · Multiple Sclerosis Journal · doi:10.1177/1352458514538110 · Cited by 309
Self-citationCheung, C. Y.-L., Ong, Y. T., Hilal, S., Ikram, M. K., Low, S., Ong, Y. L., Venketasubramanian, N., Yap, P., Seow, D., Chen, C. L. H., et al. (2015) · Journal of Alzheimer's Disease · doi:10.3233/jad-141659 · Cited by 270
Cited by
Filippi, M., Bar-Or, A., Piehl, F., Preziosa, P., Solari, A., Vukusic, S., & Rocca, M. A. (2018) · Nature Reviews Disease Primers · doi:10.1038/s41572-018-0041-4 · Cited by 1,562
Retinal layer segmentation in multiple sclerosis: a systematic review and meta-analysis
Petzold, A., Balcer, L. J., Calabresi, P. A., Costello, F., Frohman, T. C., Frohman, E. M., Martinez-Lapiscina, E. H., Green, A. J., Kardon, R., Outteryck, O., et al. (2017) · The Lancet Neurology · doi:10.1016/s1474-4422(17)30278-8 · Cited by 585
Self-citationSpectral-Domain OCT Measurements in Alzheimer’s Disease
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.08.009 · Cited by 360
Nolan‐Kenney, R. C., Liu, M., Akhand, O., Calabresi, P. A., Paul, F., Petzold, A., Balk, L., Brandt, A. U., Martínez‐Lapiscina, E. H., Saidha, S., et al. (2019) · Annals of Neurology · doi:10.1002/ana.25462 · Cited by 164
Self-citationA Clinician's Guide to Artificial Intelligence: How to Critically Appraise Machine Learning Studies
Faes, L., Liu, X., Wagner, S. K., Fu, D. J., Balaskas, K., Sim, D. A., Bachmann, L. M., Keane, P. A., & Denniston, A. K. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.7 · Cited by 162
Metadata
- Authors
- Cruz-Herranz, A., Balk, L. J., Oberwahrenbrock, T., Saidha, S., Martinez-Lapiscina, E. H., Lagreze, W. A., Schuman, J. S., Villoslada, P., Calabresi, P., Balcer, L., Petzold, A., Green, A. J., Paul, F., Brandt, A. U., Albrecht, P., IMSVISUAL consortium, Imitola, J., Toosy, A., Zimmermann, H., Outteryck, O., Nolan, R., Kolbe, S., Frederiksen Battistini, J. L., Aktas, O., Leocani, L., Yeh, A., Havla, J., Ringelstein, M., Pihl-Jensen, G., Preiningerova, J. L., Schippling, S., & Costello, F.
- Venue
- Neurology
- Published
- 2016-06-14
- Volume
- 86
- Issue
- 24
- Pages
- 2303-2309
- ISSN
- 0028-3878 (ISSN-L)
- 1526-632X
- OpenAlex
- W2401147790
- Cited by
- 416
- References
- 30
- FWCI
- 17.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The APOSTEL recommendations for reporting quantitative optical coherence tomography studies. https://app.cochat.ai/papers/10.1212/wnl.0000000000002774
- The paper
- Cruz-Herranz, A., Balk, L. J., Oberwahrenbrock, T., Saidha, S., Martinez-Lapiscina, E. H., Lagreze, W. A., Schuman, J. S., Villoslada, P., Calabresi, P., Balcer, L., Petzold, A., Green, A. J., Paul, F., Brandt, A. U., Albrecht, P., IMSVISUAL consortium, Imitola, J., Toosy, A., Zimmermann, H., . . . Costello, F. (2016). The APOSTEL recommendations for reporting quantitative optical coherence tomography studies. Neurology. https://doi.org/10.1212/wnl.0000000000002774
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.