CoChat

Retinal vascular caliber and risk of dementia: The Rotterdam Study

Open access
de Jong, F.J., Schrijvers, E.M.C., Ikram, M.K., Koudstaal, P.J., de Jong, P.T.V.M., Hofman, A., Vingerling, J.R., Breteler, M.M.B. · 2011 · Neurology
Cited by 138

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Retinal vessels provide a unique opportunity to study both systemic and cerebrovascular disease. Smaller retinal arteriolar calibers are strongly related to hypertension, whereas larger retinal venular calibers are more related to inflammation, cerebral hypoperfusion, and cerebrovascular disease. Whether retinal vessel calibers are related to dementia remains unclear. METHODS: We investigated whether retinal arteriolar and venular calibers are associated with risk of dementia, and its subtypes Alzheimer disease (AD) and vascular dementia, in the prospective population-based Rotterdam Study. Digitized retinal images were available in 5,553 participants aged 55 years or over and dementia-free at baseline (1990-1993). Participants were re-examined in 1993-1994, 1997-1999, and 2002-2004 and were continuously monitored for development of dementia. RESULTS: During a mean follow-up of 11.6 years, 655 participants developed dementia. AD was diagnosed in 519 and vascular dementia in 73 participants. Larger venular calibers were associated with an increased risk of dementia, in particular vascular dementia (age- and sex-adjusted hazard ratio per SD increase: 1.31; 95% confidence interval 1.06-1.64), but not AD. The association remained significant after adjustment for stroke and cardiovascular risk factors. Smaller arteriolar calibers were also associated with an increased risk of vascular dementia, yet only when adjusted for venular calibers. CONCLUSIONS: Retinal venular widening is associated with an increased risk of vascular dementia. Our findings are in line with previous observations in stroke and cerebral small-vessel disease and suggest that the association between larger retinal venular calibers and dementia may reflect cerebral hypoperfusion and subsequent ischemia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1212/wnl.0b013e31820e7baa

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 138

Metadata

Authors
de Jong, F. J., Schrijvers, E. M. C., Ikram, M. K., Koudstaal, P. J., de Jong, P. T. V. M., Hofman, A., Vingerling, J. R., & Breteler, M. M. B.
Venue
Neurology
Published
2011-03
Volume
76
Issue
9
Pages
816-821
ISSN
  • 0028-3878 (ISSN-L)
  • 1526-632X
OpenAlex
W1974803357
Cited by
138
References
4
FWCI
5.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Retinal vascular caliber and risk of dementia: The Rotterdam Study. https://app.cochat.ai/papers/10.1212/wnl.0b013e31820e7baa
The paper
de Jong, F. J., Schrijvers, E. M. C., Ikram, M. K., Koudstaal, P. J., de Jong, P. T. V. M., Hofman, A., Vingerling, J. R., & Breteler, M. M. B. (2011). Retinal vascular caliber and risk of dementia: The Rotterdam Study. Neurology. https://doi.org/10.1212/wnl.0b013e31820e7baa

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.