The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.
A Systematic Review (Meta-Analysis) of the Accuracy of the Mallampati Tests to Predict the Difficult Airway
Abstract
In Brief The original and modified Mallampati tests are commonly used to predict the difficult airway, but there is controversy regarding their accuracy. We searched MEDLINE and other databases for prospective studies of patients undergoing general anesthesia in which the results of a preoperative Mallampati test were compared with the subsequent rate of difficult airway (difficult laryngoscopy, difficult intubation, or difficult ventilation as reference tests). Forty-two studies enrolling 34,513 patients were included. The definitions of the reference tests varied widely. For predicting difficult laryngoscopy, both versions of the Mallampati test had good accuracy (area under the summary receiver operating characteristic (sROC) curve = 0.89 ± 0.05 and 0.78 ± 0.05, respectively). For predicting difficult intubation, the modified Mallampati test had good accuracy (area under the sROC curve = 0.83 ± 0.03) whereas the original Mallampati test was poor (area under the sROC curve = 0.58 ± 0.12). The Mallampati tests were poor at identifying difficult mask ventilation. Publication bias was not detected. Used alone, the Mallampati tests have limited accuracy for predicting the difficult airway and thus are not useful screening tests. IMPLICATIONS: The accuracy of the original and modified versions of the Mallampati test ranges from poor to good for predicting difficult laryngoscopy and difficult intubation. The Mallampati tests have limited accuracy for predicting the difficult airway and thus are not useful screening tests when used alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Users' guides to the medical literature
Guyatt, G. H. (1993) · JAMA · doi:10.1001/jama.270.17.2096 · Cited by 2,970
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
A clinical sign to predict difficult tracheal intubation; a prospective study
Mallampati, S. R., Gatt, S. P., Gugino, L. D., Desai, S. P., Waraksa, B., Freiberger, D., & Liu, P. L. (1985) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03011357 · Cited by 2,450
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
A comparison of methods to detect publication bias in meta‐analysis
Macaskill, P., Walter, S. D., & Irwig, L. (2001) · Statistics in Medicine · doi:10.1002/sim.698 · Cited by 1,286 · cited 9×
“, 1992 (33) 663 NS NS (18-88) 11 25 51 49 538 0.”
MethodInfluentialConducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Prediction of Difficult Mask Ventilation
Langeron, O., Masso, E., Huraux, C., Guggiari, M., Bianchi, A., Coriat, P., & Riou, B. (2000) · Anesthesiology · doi:10.1097/00000542-200005000-00009 · Cited by 915
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Properties of the summary receiver operating characteristic (SROC) curve for diagnostic test data
Walter, S. D. (2002) · Statistics in Medicine · doi:10.1002/sim.1099 · Cited by 672
Morbid Obesity and Tracheal Intubation
Brodsky, J. B., Lemmens, H. J. M., Brock-Utne, J. G., Vierra, M., & Saidman, L. J. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200203000-00047 · Cited by 640
The unanticipated difficult airway with recommendations for management
Crosby, E. T., Cooper, R. M., Douglas, M. J., Doyle, D. J., Hung, O. R., Labrecque, P., Muir, H., Murphy, M. F., Preston, R. P., Rose, D. K., et al. (1998) · Canadian Journal of Anaesthesia · doi:10.1007/bf03012147 · Cited by 615
Meta-analysis of screening and diagnostic tests.
Hasselblad, V., & Hedges, L. V. (1995) · Psychological Bulletin · doi:10.1037/0033-2909.117.1.167 · Cited by 579
Preoperative Airway Assessment: Predictive Value of a Multivariate Risk Index
El-Ganzouri, A. R., McCarthy, R. J., Tuman, K. J., Tanck, E. N., & Ivankovich, A. D. (1996) · Anesthesia & Analgesia · doi:10.1097/00000539-199606000-00017 · Cited by 553
Jones, C. M., & Athanasiou, T. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.09.040 · Cited by 523
Asymmetric funnel plots and publication bias in meta-analyses of diagnostic accuracy
Song, F., Khan, K. S., Dinnes, J., & Sutton, A. J. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.88 · Cited by 484
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Exploring sources of heterogeneity in systematic reviews of diagnostic tests
Lijmer, J. G., Bossuyt, P. M. M., & Heisterkamp, S. H. (2002) · Statistics in Medicine · doi:10.1002/sim.1185 · Cited by 446
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Relative Risk Analysis of Factors Associated with Difficult Intubation in Obstetric Anesthesia
Rocke, D. A., Murray, W. B., Rout, C. C., & Gouws, E. (1992) · Anesthesiology · doi:10.1097/00000542-199207000-00010 · Cited by 402
Arné, J., Descoins, P., Fusciardi, J., Ingrand, P., Ferrier, B., Boudigues, D., & Ariès, J. (1998) · British Journal of Anaesthesia · doi:10.1093/bja/80.2.140 · Cited by 401
Ezri, T., Gewürtz, G., Sessler, D. I., Medalion, B., Szmuk, P., Hagberg, C., & Susmallian, S. (2003) · Anaesthesia · doi:10.1046/j.1365-2044.2003.03412.x · Cited by 381
Prediction of difficult tracheal intubation
SAVVA, D. (1994) · British Journal of Anaesthesia · doi:10.1093/bja/73.2.149 · Cited by 369
Evaluation of an improved scoring system for the grading of direct laryngoscopy
Yentis, S. M., & Lee, D. J. H. (1998) · Anaesthesia · doi:10.1046/j.1365-2044.1998.00605.x · Cited by 369
Increase in Mallampati score during pregnancy
PILKINGTON, S., CARLI, F., DAKIN, M. J., ROMNEY, M., DE WITT, K. A., DORé, C. J., & CORMACK, R. S. (1995) · British Journal of Anaesthesia · doi:10.1093/bja/74.6.638 · Cited by 353
Khan, Z. H., Kashfi, A., & Ebrahimkhani, E. (2003) · Anesthesia & Analgesia · doi:10.1097/00000539-200302000-00053 · Cited by 323
Predicting difficult intubation
Frerk, C. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09909.x · Cited by 299
Failed intubation revisited: 17-yr experience in a teaching maternity unit
Hawthorne, L., Wilson, R., Lyons, G., & Dresner, M. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/76.5.680 · Cited by 276
Tse, J. C., Rimm, E. B., & Hussain, A. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199508000-00008 · Cited by 234
Predicting difficult intubation: a multivariable analysis
Karkouti, K., Rose, D. K., Wigglesworth, D., & Cohen, M. M. (2000) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03019474 · Cited by 192
Butler, P. J., & Dhara, S. S. (1992) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9202000202 · Cited by 180
Increased body mass indexper se is not a predictor of difficult laryngoscopy
Ezri, T., Medalion, B., Weisenberg, M., Szmuk, P., Warters, R. D., & Charuzi, I. (2003) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03017853 · Cited by 173
Difficult direct laryngoscopy in patients with cervical spine disease
CALDER, I., CALDER, J., & CROCKARD, H. A. (1995) · Anaesthesia · doi:10.1111/j.1365-2044.1995.tb06135.x · Cited by 170
Difficult Intubation in Acromegalic Patients: Incidence and Predictability
Schmitt, H., Buchfelder, M., Radespiel-Tröger, M., & Fahlbusch, R. (2000) · Anesthesiology · doi:10.1097/00000542-200007000-00020 · Cited by 165
Risk Factors Assessment of the Difficult Airway: An Italian Survey of 1956 Patients
Cattano, D., Panicucci, E., Paolicchi, A., Forfori, F., Giunta, F., & Hagberg, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000136772.38754.01 · Cited by 159
Prediction of difficult tracheal intubation
Iohom, G., Ronayne, M., & Cunningham, A. J. (2003) · European Journal of Anaesthesiology · doi:10.1097/00003643-200301000-00006 · Cited by 141
Lewis, M., Keramati, S., Benumof, J. L., & Berry, C. C. (1994) · Anesthesiology · doi:10.1097/00000542-199407000-00011 · Cited by 138
Inter-observer reliability of ten tests used for predicting difficult tracheal intubation
Karkouti, K., Rose, D., Ferris, L. E., Wigglesworth, D. F., Meisami-Fard, T., & Lee, H. (1996) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03011765 · Cited by 129
Ezri, T., Warters, R. D., Szmuk, P., Saad-Eddin, H. E., Geva, D., Katz, J. A., & Hagberg, C. A. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200110000-00055 · Cited by 117
Predicting Difficult Intubation with Indirect Laryngoscopy
Yamamoto, K., Tsubokawa, T., Shibata, K., Ohmura, S., Nitta, S., & Kobayashi, T. (1997) · Anesthesiology · doi:10.1097/00000542-199702000-00007 · Cited by 111
A survey of tracheal intubation difficulty in the operating room: a prospective observational study
Adnet, F., Racine, S. X., Borron, S. W., Clemessy, J. L., Fournier, J. L., Lapostolle, F., & Cupa, M. (2001) · Acta Anaesthesiologica Scandinavica · doi:10.1034/j.1399-6576.2001.045003327.x · Cited by 102
Prediction of difficult tracheal intubation
Iohom, G., Ronayne, M., & Cunningham, A. J. (2005) · European Journal of Anaesthesiology · doi:10.1017/s0265021503000061 · Cited by 82
Cephalometric norms for the upper airway in a healthy Hong Kong Chinese population.
Samman, N., Mohammadi, H., & Xia, J. J. (2003) · PubMed · Cited by 81
Prevalence and Prediction of Difficult Intubation in Chinese Women
Wong, S. H. S., & Hung, C. T. (1999) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9902700110 · Cited by 65
Issues in combining independent estimates of the sensitivity and specificity of a diagnostic test.
De, S. (1995) · PubMed · Cited by 45
Predicting the difficult laryngoscopic intubation: are we on the right track?
Murphy, M., Hung, O. R., Launcelott, G., Law, J. A., & Morris, I. R. (2005) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03016055 · Cited by 39
Grading of direct laryngoscopy A survey of current practice
Cohen, A. M., Fleming, B., & Wace, J. R. (1994) · Anaesthesia · doi:10.1111/j.1365-2044.1994.tb03526.x · Cited by 38
Anaesthesiological airway management in Denmark: Assessment, equipment and documentation
Mellado, P. F., Thunedborg, L. P., Swiatek, F. A., & Kristensen, M. S. (2004) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.0001-5172.2004.0337.x · Cited by 27
Saito, T., Mayumi, T., & Kemmotsu, O. (1994) · Anesthesiology · doi:10.1097/00000542-199409001-00068 · Cited by 25
Cited by
Quaife, M., Terris-Prestholt, F., Di Tanna, G. L., & Vickerman, P. (2018) · The European Journal of Health Economics · doi:10.1007/s10198-018-0954-6 · Cited by 371
Nørskov, A. K., Rosenstock, C. V., Wetterslev, J., Astrup, G., Afshari, A., & Lundstrøm, L. H. (2015) · Anaesthesia · doi:10.1111/anae.12955 · Cited by 346
Video‐laryngoscopes in the adult airway management: a topical review of the literature
NIFOROPOULOU, P., PANTAZOPOULOS, I., DEMESTIHA, T., KOUDOUNA, E., & XANTHOS, T. (2010) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2010.02285.x · Cited by 316
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008874.pub2 · Cited by 257
Self-citation
Metadata
- Authors
- Lee, A., Fan, L. T. Y., Gin, T., Karmakar, M. K., & Ngan Kee, W. D.
- Venue
- Anesthesia & Analgesia
- Published
- 2006-06
- Volume
- 102
- Issue
- 6
- Pages
- 1867-1878
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2140677359
- Cited by
- 319
- References
- 57
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.