CoChat

A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery

Wax, David B., Rubin, Philip, Neustein, Steven · 2009 · Anesthesia & Analgesia
Cited by 38

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: New reflectance pulse oximetry probes placed on the forehead may be an improvement over transmittance probes placed on a finger, toe, or earlobe in patients with compromised perfusion. We compared the reliability and accuracy of the 2 types of probes in patients undergoing vascular surgery. METHODS: Patients with peripheral vascular disease undergoing vascular surgery under general anesthesia were monitored with both a transmittance earlobe probe and a reflectance forehead probe. Spo(2) was recorded continuously from both probes, and arterial blood gas samples were analyzed when clinically indicated. The average values from both probes over each minute were compared using Bland-Altman analysis. RESULTS: Twenty patients were included yielding a total of 3993 1-min averaged data pairs. Neither probe failed to report a value for more than 1 min. A Bland-Altman plot showed the limits of agreement between the probes of -4.0% to +2.6%. Twenty-eight arterial blood samples were analyzed for 14 patients and Sao(2) closely matched both Spo(2) probe values at the time of sampling. Compared with Sao(2), analysis demonstrated limits of agreement of -4.7% to 6.1% for ear and -3.3% to 3.4% for forehead sites. CONCLUSIONS: The new reflectance forehead Spo(2) probe tested has acceptable agreement with the older transmittance probe placed on the earlobe for pulse oximetry within typical ranges of Spo(2) in patients undergoing vascular surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/ane.0b013e3181bbc446

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 38

Metadata

Authors
Wax, D. B., Rubin, P., & Neustein, S.
Venue
Anesthesia & Analgesia
Published
2009-12
Volume
109
Issue
6
Pages
1847-1849
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2000399835
Cited by
38
References
3
FWCI
1.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery. https://app.cochat.ai/papers/10.1213/ane.0b013e3181bbc446
The paper
Wax, D. B., Rubin, P., & Neustein, S. (2009). A Comparison of Transmittance and Reflectance Pulse Oximetry During Vascular Surgery. Anesthesia & Analgesia. https://doi.org/10.1213/ane.0b013e3181bbc446

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.