The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
A Critical Review of the Ability of Continuous Cardiac Output Monitors to Measure Trends in Cardiac Output
Abstract
Numerous cardiac output (CO) monitors have been produced that provide continuous rather than intermittent readings. Bland and Altman has become the standard method for validating their performance against older standards. However, the Bland and Altman method only assesses precision and does not assess how well a device detects serial changes in CO (trending ability). Currently, there is no consensus on how trending ability, or trend analysis, should be performed. Therefore, we performed a literature review to identify articles published between 1997 and 2009 that compared methods of continuous CO measurement. Identified articles were grouped according to measurement technique and statistical methodology. Articles that analyzed trending ability were reviewed with the aim of finding an acceptable statistical method. Two hundred two articles were identified. The most popular methods were pulse contour (69 articles), Doppler (54), bioimpedance (38), and transpulmonary or continuous thermodilution (27). Forty-one articles addressed trending, and of these only 23 provided an in-depth analysis. Several common statistical themes were identified: time plots, regression analysis, Bland and Altman using change in CO (ΔCO), and the 4-quadrant plot, which used direction of change of ΔCO to determine the concordance. This plot was further refined by exclusion of data when values were small. Receiver operating characteristic curves were used to define the exclusion zone. In animal studies, a reliable reference standard such as an aortic flowprobe was frequently used, and regression or time plots could be used to show trending. Clinical studies were more problematic because data collection points were fewer (8-10 per subject). The consensus was to use the 4-quadrant plot with exclusion zones and apply concordance analysis. A concordance rate of >92% when using a 15% zone indicated good trending. A new method of presenting trend data (ΔCO) on a polar plot is proposed. Agreement was shown by the angle with the horizontal axis and ΔCO by the distance from the center. Trending can be assessed by the vertical limits of the data, similar to the Bland and Altman method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
3 retracted
Mayer, J., Boldt, J., Poland, R., Peterson, A. J., & Manecke, G. R. (2009) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2009.03.003 · Cited by 142
RetractedMayer, J., Boldt, J., Wolf, M. W., Lang, J. K., & Suttner, S. W. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318161964d · Cited by 101
RetractedMayer, J., Boldt, J., Beschmann, R., Stephan, A., & Suttner, S. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep133 · Cited by 24
RetractedSTATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 1,864
Critchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
Self-citationDevelopment and evaluation of an impedance cardiac output system.
Kubicek, W. G., Karnegis, J. N., PATTERSON, R. P., Witsoe, D. A., & Mattson, R. H. (1966) · PubMed · Cited by 1,143
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Harvey, S., Harrison, D. A., Singer, M., Ashcroft, J., Jones, C. M., Elbourne, D., Brampton, W., Williams, D., Young, D., & Rowan, K. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67061-4 · Cited by 1,126
Receiver Operating Characteristic Curves and Their Use in Radiology
Obuchowski, N. A. (2003) · Radiology · doi:10.1148/radiol.2291010898 · Cited by 843
I. Using the Bland–Altman method to measure agreement with repeated measures
Myles, P. S., & Cui, J. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem214 · Cited by 620
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale
BERNSTEIN, D. P. (1986) · Critical Care Medicine · doi:10.1097/00003246-198610000-00017 · Cited by 456
Noninvasive cardiac output monitoring (NICOM): a clinical validation
Squara, P., Denjean, D., Estagnasie, P., Brusset, A., Dib, J. C., & Dubois, C. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0640-0 · Cited by 320
Cardiac Output Monitoring Using Indicator-Dilution Techniques: Basics, Limits, and Perspectives
Reuter, D. A., Huang, C., Edrich, T., Shernan, S. K., & Eltzschig, H. K. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181cc885a · Cited by 284
Noninvasive Monitoring of Cardiac Output in Critically Ill Patients Using Transesophageal Doppler
Valtier, B., Cholley, B., Belot, J.-P., Coussaye, J.-E. D. L., Matéo, J., & Payen, D. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9707031 · Cited by 235
Multicenter Evaluation of Noninvasive Cardiac Output Measurement by Bioreactance Technique
Raval, N. Y., Squara, P., Cleman, M., Yalamanchili, K., Winklmaier, M., & Burkhoff, D. (2008) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-008-9112-5 · Cited by 229
Matthieu, B., Karine, N.-G., Vincent, C., Alain, V., François, C. J., Philippe, R., & François, S. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b309 · Cited by 187
Intraoperative Determination of Cardiac Output Using Multiplane Transesophageal Echocardiography
Perrino, A. C., Harris, S. N., & Luther, M. A. (1998) · Anesthesiology · doi:10.1097/00000542-199808000-00010 · Cited by 175
Biancofiore, G., Critchley, L. A. H., Lee, A. S. Y., Bindi, L. M., Bisà, M., Esposito, M., Meacci, L., Mozzo, R., SIMONE, P. D., Urbani, L., et al. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen343 · Cited by 174
Self-citationA meta-analysis of three decades of validating thoracic impedance cardiography
Raaijmakers, E., Faes, T. J. C., Scholten, R. J. P. M., Goovaerts, H. G., & Heethaar, R. M. (1999) · Critical Care Medicine · doi:10.1097/00003246-199906000-00053 · Cited by 160
An evaluation of cardiac output by five arterial pulse contour techniques during cardiac surgery
de Wilde, R. B. P., Schreuder, J. J., Berg, P. C. M. V. D., & Jansen, J. R. C. (2007) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05135.x · Cited by 149
Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery
Sageman, W. S., Riffenburgh, R. H., & Spiess, B. D. (2002) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2002.29635 · Cited by 146
Marqué, S., Cariou, A., Chiche, J., & Squara, P. (2009) · Critical Care · doi:10.1186/cc7884 · Cited by 143
Albert, N. M., Hail, M. D., Li, J., & Young, J. B. (2004) · American Journal of Critical Care · doi:10.4037/ajcc2004.13.6.469 · Cited by 134
Bajorat, J., Hofmockel, R., Vagts, D. A., Janda, M., Pohl, B., Beck, C. E., & Noeldge‐Schomburg, G. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021505001717 · Cited by 96
Critchley, L. A. H., Peng, Z. Y., Fok, B. S. P., Lee, A. S. Y., & Phillips, R. A. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000144774.42408.05 · Cited by 94
Self-citationBein, B., Meybohm, P., Cavus, E., Renner, J., Tonner, P. H., Steinfath, M., Scholz, J., & Doerges, V. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268140.02147.ed · Cited by 85
Böttiger, B. W., Rauch, H., Bohrer, H., Motsch, J., Soder, M., Fleischer, F., & Martin, E. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80095-3 · Cited by 77
Osthaus, W. A., Huber, D., BECK, C., Winterhalter, M., Boethig, D., Wessel, A., & Sümpelmann, R. (2007) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2007.02210.x · Cited by 71
Dean, D. A., Jia, C.-X., Cabreriza, S. E., ALESSANDRO, D. A. D., Dickstein, M. L., Sardo, M. J., Chalik, N., & Spotnitz, H. M. (1996) · ASAIO Journal · doi:10.1097/00002480-199609000-00072 · Cited by 70
The Accuracy of the Vigileo/FloTrac Continuous Cardiac Output Monitor
Zimmermann, A., Kufner, C., Hofbauer, S., Steinwendner, J., Hitzl, W., Fritsch, G., Schistek, R., Kirnbauer, M., & Pauser, G. (2008) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2007.11.001 · Cited by 64
Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model
Lemson, J., de Boode, W. P., Hopman, J. C. W., Singh, S. K., & van der Hoeven, J. G. (2008) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e31816c6fa1 · Cited by 62
Performance of three minimally invasive cardiac output monitoring systems
de Wilde, R. B. P., Geerts, B. F., Cui, J., Berg, P. C. M. V. D., & Jansen, J. R. C. (2009) · Anaesthesia · doi:10.1111/j.1365-2044.2009.05934.x · Cited by 53
Fellahi, J.-L., Caille, V., Charron, C., et al. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31819cd97e · Cited by 51
Critchley, L. A. H., Calcroft, R. M., Tan, P., Kew, J., & Critchley, J. (2000) · Intensive Care Medicine · doi:10.1007/s001340051232 · Cited by 49
Self-citationAxler, O., Tousignant, C. P., Thompson, C., DALL'AVA-SANTUCCI, J., Phang, P. T., Russell, J. A., & Walley, K. R. (1996) · Journal of Critical Care · doi:10.1016/s0883-9441(96)90006-4 · Cited by 48
Endotracheal Cardiac Output Monitor
Wallace, A. W., Salahieh, A., Lawrence, A. T., Spector, K., Owens, C., & Alonso, D. (2000) · Anesthesiology · doi:10.1097/00000542-200001000-00030 · Cited by 44
Chatti, R., Rudnicki, S. D., Marqué, S., Dumenil, A. S., Descorps-Declere, A., Cariou, A., Duranteau, J., Aout, M., Vicaut, É., & Cholley, B. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep020 · Cited by 42
Cardiac output – pulse contour analysis vs. pulmonary artery thermodilution
Østergaard, M. V., Nielsen, J., Rasmussen, J., & Berthelsen, P. G. (2006) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01080.x · Cited by 41
Continuous thermodilution cardiac output: Agreement with fick and bolus thermodilution methods
Thrush, D. N., Downs, J. B., & Smith, R. A. (1995) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1016/s1053-0770(05)80094-1 · Cited by 37
Pulse contour cardiac output analysis in a piglet model of severe hemorrhagic shock*
Piehl, M. D., Manning, J. E., McCurdy, S. L., Rhue, T. S., Kocis, K. C., Cairns, C. B., & Cairns, B. A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31816592a3 · Cited by 36
Measurement of cardiac output after cardiac surgery by a new transesophageal doppler device
Jaeggi, P., Hofer, C. K., Klaghofer, R., Fodor, P., Genoni, M., & Zollinger, A. (2003) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/jcan.2003.50 · Cited by 36
Transoesophageal echocardiography accurately detects cardiac output variation
Parra, V., Fita, G., Rovira, I., Matute, P., Gomar, C. G., & Paré, C. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507001354 · Cited by 35
Comparison of continuous thermodilution and bolus cardiac output measurements in septic shock
Sun, Q., Rogiers, P., Pauwels, D., & Vincent, J. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1415-2 · Cited by 33
Boyle, M., Steel, L., Flynn, G. M., Murgo, M., Nicholson, L., O’Brien, M., & Bihari, D. J. (2009) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01556-9 · Cited by 30
Shih, A., Giguère, S., Sanchez, L. C., Valverde, A., Bandt, C., Jankunas, H., & Robertson, S. A. (2009) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.2009.00461.x · Cited by 28
Corley, A., Barnett, A. G., Mullany, D. V., et al. (2009) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.03.013 · Cited by 23
Boucaud, C., Bouffard, Y., Dumortier, J., Gaillac, N., Sagnard, P. E., Graber, M. C., Adham, M., & Boillot, O. (2008) · European Journal of Anaesthesiology · doi:10.1017/s0265021508003670 · Cited by 19
Raaijmakers, E., Faes, T. J. C., Kunst, P. W. A., Bakker, J., Rommes, J. H., Goovaerts, H. G., & Heethaar, R. M. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/4/004 · Cited by 16
Comparing different methods of cardiac output determination
Bein, B., Renner, J., Scholz, J., & Tonner, P. H. (2006) · European Journal of Anaesthesiology · doi:10.1017/s0265021506211128 · Cited by 13
Cited by
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Morrow, D. A., Fang, J. C., Fintel, D. J., Granger, C. B., Katz, J. N., Kushner, F. G., Kuvin, J. T., Lopez-Sendon, J., McAreavey, D., Nallamothu, B., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31826890b0 · Cited by 310
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Marik, P. E. (2013) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2012.03.022 · Cited by 293
Noninvasive continuous cardiac output monitoring in perioperative and intensive care medicine
Saugel, B., Cecconi, M., Wagner, J. Y., & Reuter, D. A. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aeu447 · Cited by 268
Current use of the pulmonary artery catheter in cardiac surgery: a survey study
Judge, O., Ji, F., Fleming, N., & Liu, H. (2015) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2014.07.016 · Cited by 93
Metadata
- Authors
- Critchley, L. A., Lee, A., & Ho, A. M.-H.
- Venue
- Anesthesia & Analgesia
- Published
- 2010-11
- Volume
- 111
- Issue
- 5
- Pages
- 1180-1192
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2069216248
- Cited by
- 512
- References
- 55
- FWCI
- 36.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.