Ensemble Recordings Of Human Subcortical Neurons as a Source Of Motor Control Signals For a Brain-Machine Interface
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Patients with severe neurological injury, such as quadriplegics, might benefit greatly from a brain-machine interface that uses neuronal activity from motor centers to control a neuroprosthetic device. Here, we report an implementation of this strategy in the human intraoperative setting to assess the feasibility of using neurons in subcortical motor areas to drive a human brain-machine interface. METHODS: Acute ensemble recordings from subthalamic nucleus and thalamic motor areas (ventralis oralis posterior [VOP]/ventralis intermediate nucleus [VIM]) were obtained in 11 awake patients during deep brain stimulator surgery by use of a 32-microwire array. During extracellular neuronal recordings, patients simultaneously performed a visual feedback hand-gripping force task. Offline analysis was then used to explore the relationship between neuronal modulation and gripping force. RESULTS: Individual neurons (n = 28 VOP/VIM, n = 119 subthalamic nucleus) demonstrated a variety of modulation responses both before and after onset of changes in gripping force of the contralateral hand. Overall, 61% of subthalamic nucleus neurons and 81% of VOP/VIM neurons modulated with gripping force. Remarkably, ensembles of 3 to 55 simultaneously recorded neurons were sufficiently information-rich to predict gripping force during 30-second test periods with considerable accuracy (up to R = 0.82, R(2) = 0.68) after short training periods. Longer training periods and larger neuronal ensembles were associated with improved predictive accuracy. CONCLUSION: This initial feasibility study bridges the gap between the nonhuman primate laboratory and the human intraoperative setting to suggest that neuronal ensembles from human subcortical motor regions may be able to provide informative control signals to a future brain-machine interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
Haykin, S. (1986) · Cited by 12,603
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Time Series: Data Analysis and Theory.
Koopmans, L. H., & Brillinger, D. R. (1976) · Journal of the American Statistical Association · doi:10.2307/2285347 · Cited by 2,637
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 6×
“suggest that multineuronal recordings are critical for neuroprosthetic applications and may require a minimum of 50 to 100 recorded neurons to drive a real-time neuroprosthesis (5, 22).”
BackgroundMethodResultInfluentialSelf-citationDirect Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540 · cited 2×
“For example, neuronal ensemble recordings from motor areas of cerebral cortex in nonhuman primates have been demonstrated to accurately predict three-dimensional arm movements (26, 27, 29) and to successfully control a robotic arm neuroprosthetic device (5, 29).”
BackgroundReal-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487 · cited 5×
“Our findings resemble the results of nonhuman primate studies (5, 29), because increasing correlations between hand-gripping force and model predictions were obtained by adding neurons and lengthening the training period.”
BackgroundMethodResultInfluentialSelf-citationCellular networks underlying human spatial navigation
Ekstrom, A. D., Kahana, M. J., Caplan, J. B., Fields, T. A., Isham, E. A., Newman, E. L., & Fried, I. (2003) · Nature · doi:10.1038/nature01964 · Cited by 1,425 · cited 2×
“These designs include silicon-based chip electrodes (20), the neurotrophic electrode (14, 15), and either fixed grid arrays of microwires (23) or loose microwires inserted as a bundle (10, 16).”
BackgroundMethodInstant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Chronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740 · cited 5×
“These designs include silicon-based chip electrodes (20), the neurotrophic electrode (14, 15), and either fixed grid arrays of microwires (23) or loose microwires inserted as a bundle (10, 16).”
BackgroundMethodInfluentialSelf-citation
Research works printed but not linked: 8
- Benabid, 2001, Deep brain stimulation for Parkinsons disease., Adv Neurol, 86, 405
- Chang, 1991, Estimate of motor conduction in human spinal cord: Slowed conduction in spinal cord injury., Muscle Nerve, 14, 990, 10.1002/mus.880141010 · doi:10.1002/mus.880141010
- Kennedy, 1998, Restoration of neural output from a paralyzed patient by a direct brain connection., Neuroreport, 9, 1707, 10.1097/00001756-199806010-00007 · DOI · Paper page
- Kennedy, 2000, Direct control of a computer from the human central nervous system., IEEE Trans Rehabil Eng, 9, 198, 10.1109/86.847815 · DOI · Paper page
- Machida, 1991, Magnetic stimulation: Examination of motor function in patients with cervical spine or cord lesion., J Spinal Disord, 4, 123, 10.1097/00002517-199106000-00001 · doi:10.1097/00002517-199106000-00001
- Smith, 2000, Modulation of single motor unit discharges using magnetic stimulation of the motor cortex in incomplete spinal cord injury., J Neurol Neurosurg Psychiatry, 68, 516, 10.1136/jnnp.68.4.516 · doi:10.1136/jnnp.68.4.516
- Wyler, 1983, Interneuronal synchrony in precentral cortex of monkeys during operant conditioning., Exp Neurol, 80, 697, 10.1016/0014-4886(83)90319-9 · doi:10.1016/0014-4886(83)90319-9
- Wyler, 1980, Operant control of pre-central neurons: Control of modal interspike intervals., Brain Res, 190, 29, 10.1016/0006-8993(80)91157-9 · doi:10.1016/0006-8993(80)91157-9
Cited by
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
“67 Evarts, E.V. (1968) Relation of pyramidal tract activity to force exerted during voluntary movement.”
BackgroundMethodInfluentialSelf-citationBashashati, A., Fatourechi, M., Ward, R. K., & Birch, G. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r03 · Cited by 907
Cognitive Enhancement: Methods, Ethics, Regulatory Challenges
Bostrom, N., & Sandberg, A. (2009) · Science and Engineering Ethics · doi:10.1007/s11948-009-9142-5 · Cited by 741
A high-performance brain–computer interface
Santhanam, G., Ryu, S. I., Yu, B. M., Afshar, A., & Shenoy, K. V. (2006) · Nature · doi:10.1038/nature04968 · Cited by 698
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Self-citationPrinciples of neural ensemble physiology underlying the operation of brain–machine interfaces
Nicolelis, M. A. L., & Lebedev, M. A. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2653 · Cited by 483
Self-citationMitochondrial Ca2+ and apoptosis
Giorgi, C., Baldassari, F., Bononi, A., Bonora, M., De Marchi, E., Marchi, S., Missiroli, S., Patergnani, S., Rimessi, A., Suski, J. M., et al. (2012) · Cell Calcium · doi:10.1016/j.ceca.2012.02.008 · Cited by 474
Donati, A. R. C., Shokur, S., Morya, E., Campos, D. S. F., Moioli, R. C., Gitti, C. M., Augusto, P. B., Tripodi, S., Pires, C. G., Pereira, G. A., et al. (2016) · Scientific Reports · doi:10.1038/srep30383 · Cited by 428
Self-citationInvasive recordings from the human brain: clinical insights and beyond
Engel, A. K., Moll, C. K. E., Fried, I., & Ojemann, G. A. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1585 · Cited by 419
Brain plasticity: From pathophysiological mechanisms to therapeutic applications
Duffau, H. (2006) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2005.11.045 · Cited by 354
Cerebral cavernous malformations proteins inhibit Rho kinase to stabilize vascular integrity
Stockton, R. A., Shenkar, R., Awad, I. A., & Ginsberg, M. H. (2010) · Journal of Experimental Medicine · doi:10.1084/jem.20091258 · Cited by 351
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Self-citationSelecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
Garzon, M. C., Huang, J. T., Enjolras, O., & Frieden, I. J. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.05.069 · Cited by 329
Hemorrhage From Cavernous Malformations of the Brain: Definition and Reporting Standards
Al-Shahi Salman, R., Berg, M. J., Morrison, L., & Awad, I. A. (2008) · Stroke · doi:10.1161/strokeaha.108.515544 · Cited by 302
A Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
Lebedev, M. A., Carmena, J. M., O'Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Principe, J. C., & Nicolelis, M. A. L. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 290
Self-citationDecoding Trajectories from Posterior Parietal Cortex Ensembles
Mulliken, G. H., Musallam, S., & Andersen, R. A. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.1463-08.2008 · Cited by 231
“…targeted multiple brain areas and signal types (Kennedy et al., 2000; Wessberg et al., 2000; Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Shenoy et al., 2003; Musallam et al., 2004; Patil et al., 2004; Wolpaw and McFarland, 2004; Hochberg et al., 2006; Santhanam et al., 2006).”
BackgroundElectrochemical polymerization of conducting polymers in living neural tissue
Richardson-Burns, S. M., Hendricks, J. L., & Martin, D. C. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/l02 · Cited by 195
Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 187
“Although rarely studied in the context of a motor BMI, subcortical regions such as the motor thalamus and subthalamic nucleus (STN) are also involved inmotor planning and execution (Friehs et al., 2004; Patil et al., 2004; Hanson et al., 2012; Ryapolova-Webb et al., 2014).”
BackgroundSelf-citationExtracting kinematic parameters for monkey bipedal walking from cortical neuronal ensemble activity
Fitzsimmons, N. A. (2009) · Frontiers in Integrative Neuroscience · doi:10.3389/neuro.07.003.2009 · Cited by 186
Unscented Kalman Filter for Brain-Machine Interfaces
Li, Z., O'Doherty, J. E., Hanson, T. L., Lebedev, M. A., Henriquez, C. S., & Nicolelis, M. A. L. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006243 · Cited by 186
Self-citationHuman Intracranial Recordings and Cognitive Neuroscience
Mukamel, R., & Fried, I. (2012) · Annual Review of Psychology · doi:10.1146/annurev-psych-120709-145401 · Cited by 182
Strategy for Identifying Repurposed Drugs for the Treatment of Cerebral Cavernous Malformation
Gibson, C. C., Zhu, W., Davis, C. T., Bowman-Kirigin, J. A., Chan, A. C., Ling, J., Walker, A. E., Goitre, L., Delle Monache, S., Retta, S. F., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.010403 · Cited by 175
A Brain-Machine Interface Enables Bimanual Arm Movements in Monkeys
Ifft, P. J., Shokur, S., Li, Z., Lebedev, M. A., & Nicolelis, M. A. L. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3006159 · Cited by 173
“Previous BMIs mimicked only single arm control represented by either a computer cursor (6–11), a robot (8, 12, 13), or an avatar arm (14), but did not enable simultaneous bimanual control of arm movements.”
Self-citationHuman cortical prostheses: lost in translation?
Ryu, S. I., & Shenoy, K. V. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0987 · Cited by 104
Christie, B. P., Tat, D. M., Irwin, Z. T., Gilja, V., Nuyujukian, P., Foster, J. D., Ryu, S. I., Shenoy, K. V., Thompson, D. E., & Chestek, C. A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016009 · Cited by 103
Deep brain stimulation: current and future perspectives
Awan, N. R., Lozano, A., & Hamani, C. (2009) · Neurosurgical Focus · doi:10.3171/2009.4.focus0982 · Cited by 83
Recording and decoding for neural prostheses
Warren, D. J., Kellis, S., Nieveen, J. G., Wendelken, S. M., Dantas, H., Davis, T. S., Hutchinson, D. T., Normann, R. A., Clark, G. A., & Mathews, V. J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2507180 · Cited by 52
Tankus, A., Solomon, L., Aharony, Y., Faust-Socher, A., & Strauss, I. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3315 · Cited by 20
Metadata
- Authors
- Patil, P. G., Carmena, J. M., Nicolelis, M. A. L., & Turner, D. A.
- Venue
- Neurosurgery
- Published
- 2004-07
- Volume
- 55
- Issue
- 1
- Pages
- 27-38
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2413587420
- Cited by
- 208
- References
- 44
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.