Synthetic Nerve Guide Implants in Humans: A Comprehensive Survey
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Lesions of the peripheral nervous system result in the loss of sensory and motor function and may in addition be accompanied by severe neuropathic syndromes originating from aberrant axonal regrowth. The transplantation of autologous nerve grafts represents the current "gold standard" during reconstructive surgery, despite obvious side effects. Depending on the demands of the lesion site, various donor nerves may be used for grafting (e.g., the sural, saphenous), sacrificing native functions in their target areas. Recently, several synthetic nerve guide implants have been introduced and approved for clinical use to replace autologous transplants. This alternative therapy is based on pioneering studies with experimental nerve guides. METHODS: We present a comprehensive review of all published human studies involving synthetic nerve guides. RESULTS: Data from some 300 patients suggest that for short nerve defects of a few centimeters, resorbable implants provide promising results, whereas a number of late compression syndromes have been documented for nonresorbable implants. CONCLUSIONS: To treat longer defects, further implant development is needed, a goal that could be achieved, for example, by more closely imitating the intact nerve architecture and regulatory cell-cell interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The cellular and molecular basis of peripheral nerve regeneration
Fu, S. Y., & Gordon, T. (1997) · Molecular Neurobiology · doi:10.1007/bf02740621 · Cited by 1,202
Surgery of the peripheral nerve
Harrison, D. H. (1989) · British Journal of Plastic Surgery · doi:10.1016/0007-1226(89)90093-3 · Cited by 807
Surgical Disorders of the Peripheral Nerves
(1972) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1972.tb88216.x · Cited by 749
Encyclopedia of Biomaterials and Biomedical Engineering
(2008) · CRC Press eBooks · doi:10.1201/9780429154065 · Cited by 700
Peripheral Nerve Injury and Repair
Lee, S. K., & Wolfe, S. W. (2000) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200007000-00005 · Cited by 685 · cited 1×
“The depicted data support the notion that the regeneration success obtained with resorbable synthetic nerve guides is equivalent to that achieved with autologous nerve grafts, which result in recovery in the range of 0 to 69% (11, 12, 21, 29).”
BackgroundSurgery of the peripheral nerve
(2009) · Operative Orthopaedics: The Stanmore Guide · doi:10.1201/b13554-10 · Cited by 645
Encyclopedia of biomaterials and biomedical engineering
(2004) · Choice Reviews Online · doi:10.5860/choice.42-1940 · Cited by 592
Weber, R. A., Breidenbach, W. C., Brown, R. E., Jabaley, M. E., & Mass, D. P. (2000) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-200010000-00013 · Cited by 552
Clinical Nerve Reconstruction with a Bioabsorbable Polyglycolic Acid Tube
Mackinnon, S. E., & Dellon, A. L. (1990) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199003000-00015 · Cited by 535 · cited 2×
“Mackinnon and Dellon, 1990 (30) 15 Ø 30 Digital nerves PGA 5-30 11–32”
MethodPeripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 415
Marino, R. J., Ditunno, J. F., Donovan, W. H., & Maynard, F. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90249-6 · Cited by 365 · cited 1×
“To date, human application has been restricted to the peripheral nervous system, although it is obvious that paralytic patients experiencing spinal cord lesion (incidence, 30,000) (31) could benefit from conduit implants to bridge secondary cysts in the spinal cord.”
BackgroundBattiston, B., Geuna, S., Ferrero, M., & Tos, P. (2005) · Microsurgery · doi:10.1002/micr.20127 · Cited by 346 · cited 3×
“, 2005 (1) 17 13 ctrl 15–67 Digital nerve PGA 10–40 6–74”
BackgroundComplications from silicon‐polymer intubulation of nerves
Merle, M., Lee Dellon, A., Campbell, J. N., & Chang, P. S. (1989) · Microsurgery · doi:10.1002/micr.1920100213 · Cited by 298
Clinical Use of Nerve Conduits in Peripheral-Nerve Repair: Review of the Literature
Meek, M. F., & Coert, J. H. (2002) · Journal of Reconstructive Microsurgery · doi:10.1055/s-2002-19889 · Cited by 251 · cited 1×
“Published human studies of synthetic nerve guides have thus far been limited to four different materials (1, 10, 34).”
BackgroundBertleff, M. J. O. E., Meek, M. F., & Nicolai, J.-P. A. (2005) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.12.009 · Cited by 233 · cited 2×
“, 2005 (2) 17 13 ctrl Ø 43–38 Digital nerve PLCL 2–20 3–12”
BackgroundLundborg, G., Rosén, B., Dahlin, L., Danielsen, N., & Holmberg, J. (1997) · The Journal of Hand Surgery · doi:10.1016/s0363-5023(05)80188-1 · Cited by 202 · cited 3×
“The randomized, clinical, prospective study that compared 18 patients with hand injuries (age, 12–72 yr) included direct coaptation of nerve ends (seven patients) and tubulation with silicone tubes (11 patients) (26).”
BackgroundChallenges to nerve regeneration
Evans, G. R. D. (2000) · Seminars in Surgical Oncology · doi:10.1002/1098-2388(200010/11)19:3<312::aid-ssu13>3.0.co;2-m · Cited by 192 · cited 1×
“The depicted data support the notion that the regeneration success obtained with resorbable synthetic nerve guides is equivalent to that achieved with autologous nerve grafts, which result in recovery in the range of 0 to 69% (11, 12, 21, 29).”
BackgroundUse of Tubes in Peripheral Nerve Repair
Dahlin, L. B., & Lundborg, G. (2001) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30059-7 · Cited by 183 · cited 1×
“In addition, insufficient matrix formation has been discussed as inhibitory cause (8).”
BackgroundCasella, G. T. B., Bunge, R. P., & Wood, P. M. (1996) · Glia · doi:10.1002/(sici)1098-1136(199608)17:4<327::aid-glia7>3.0.co;2-w · Cited by 177
Neuro tissue engineering of glial nerve guides and the impact of different cell types
Lietz, M., Dreesmann, L., Hoss, M., Oberhoffner, S., & Schlosshauer, B. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.007 · Cited by 156
Self-citationTubular Repair of the Median Nerve in the Human Forearm: Preliminary findings
Lundborg, G., Rosén, B., Abrahamsson, S., Dahlin, L. B., & Danielsen, N. (1994) · Journal of Hand Surgery (European Volume) · doi:10.1016/0266-7681(94)90068-x · Cited by 123 · cited 2×
“, 1994 (25) 2 12, 21 Median nerve Silicone 3–5 36 Lundborg et al.”
BackgroundPeripheral Nerve Repair and Grafting Techniques. A Revrew.
MATSUYAMA, T., Mackay, M., & Midha, R. (2000) · Neurologia medico-chirurgica · doi:10.2176/nmc.40.187 · Cited by 122 · cited 1×
“(32) demonstrated in their studies the importance of the right choice of grafting nerve.”
BackgroundRat Schwann cells in bioresorbable nerve guides to promote and accelerate axonal regeneration
Schlosshauer, B., Müller, E. H., Schröder, B., Planck, H., & Müller, H.-W. (2003) · Brain Research · doi:10.1016/s0006-8993(02)03930-6 · Cited by 115
Self-citationNeurotube® for facial nerve repair
Navissano, M., Malàn, F., Carnino, R., & Battiston, B. (2005) · Microsurgery · doi:10.1002/micr.20128 · Cited by 107 · cited 2×
“Another report presented seven young patients (average age, 26 yr) who received PGA implants approximately 2 weeks after trauma to cure lesions of terminal branches of the facial nerve (38).”
BackgroundReconstruction of Upper‐Extremity Peripheral‐Nerve Injuries with ePTFE Conduits
Stanec, S., & Stanec, Z. (1998) · Journal of Reconstructive Microsurgery · doi:10.1055/s-2007-1000173 · Cited by 96 · cited 2×
“The same authors published a study with 43 patients who experienced nerve lesions ranging from 15 to 60 mm in the lower arm (47).”
BackgroundPitta, M. C., Wolford, L. M., Mehra, P., & Hopkin, J. (2001) · Journal of Oral and Maxillofacial Surgery · doi:10.1053/joms.2001.22671 · Cited by 93 · cited 2×
“In another study, six cases with GoreTex vein graft tubing as a conduit for the repair of inferior alveolar nerves and lingual nerves were reported (39).”
BackgroundInferior Alveolar Nerve Reconstruction with a Polyglycolic Acid Bioabsorbable Nerve Conduit
Crawley, W. A., & Dellon, L. A. (1992) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199290020-00022 · Cited by 73 · cited 3×
“After surgery, complete relief from facial pain was reported, and 2 years later, sensory and motor function had nearly completely recovered (6).”
BackgroundInada, Y., Morimoto, S., Moroi, K., Endo, K., & Nakamura, T. (2005) · Pain · doi:10.1016/j.pain.2005.05.033 · Cited by 63 · cited 2×
“, 2005 (14) 2 30, 49 Digital nerve PGA 25–36 9–12”
BackgroundKim, J., & Dellon, A. L. (2001) · The Journal of Foot & Ankle Surgery · doi:10.1016/s1067-2516(01)80069-7 · Cited by 54 · cited 2×
“After resection of the neuroma and subsequent axonal regrowth via the PGA implant, the boy had recovered completely and participated in sports (18).”
BackgroundUlnar nerve reconstruction with an expanded polytetrafluoroethylene conduit
Stanec, S., & Stanec, Z. (1998) · British Journal of Plastic Surgery · doi:10.1054/bjps.1998.9996 · Cited by 45
Jansen, K., Meek, M. F., van der Werff, J. F. A., van Wachem, P. B., & van Luyn, M. J. A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30004 · Cited by 35
Cited by
Kehoe, S., Zhang, X. F., & Boyd, D. (2012) · Injury · doi:10.1016/j.injury.2010.12.030 · Cited by 725
Peripheral nerve regeneration: Experimental strategies and future perspectives
Faroni, A., Mobasseri, S. A., Kingham, P. J., & Reid, A. J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.010 · Cited by 592
Topography, Cell Response, and Nerve Regeneration
Hoffman-Kim, D., Mitchel, J. A., & Bellamkonda, R. V. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105351 · Cited by 516
Repairing injured peripheral nerves: Bridging the gap
Deumens, R., Bozkurt, A., Meek, M. F., Marcus, M. A. E., Joosten, E. A. J., Weis, J., & Brook, G. A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.002 · Cited by 510
Implanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Metadata
- Authors
- Schlosshauer, B., Dreesmann, L., Schaller, H.-E., & Sinis, N.
- Venue
- Neurosurgery
- Published
- 2006-10
- Volume
- 59
- Issue
- 4
- Pages
- 740-748
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W1994069311
- Cited by
- 245
- References
- 31
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.