VIRTUAL REALITY IN NEUROSURGICAL EDUCATION: PART-TASK VENTRICULOSTOMY SIMULATION WITH DYNAMIC VISUAL AND HAPTIC FEEDBACK
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Mastery of the neurosurgical skill set involves many hours of supervised intraoperative training. Convergence of political, economic, and social forces has limited neurosurgical resident operative exposure. There is need to develop realistic neurosurgical simulations that reproduce the operative experience, unrestricted by time and patient safety constraints. Computer-based, virtual reality platforms offer just such a possibility. The combination of virtual reality with dynamic, three-dimensional stereoscopic visualization, and haptic feedback technologies makes realistic procedural simulation possible. Most neurosurgical procedures can be conceptualized and segmented into critical task components, which can be simulated independently or in conjunction with other modules to recreate the experience of a complex neurosurgical procedure. METHODS: We use the ImmersiveTouch (ImmersiveTouch, Inc., Chicago, IL) virtual reality platform, developed at the University of Illinois at Chicago, to simulate the task of ventriculostomy catheter placement as a proof-of-concept. Computed tomographic data are used to create a virtual anatomic volume. RESULTS: Haptic feedback offers simulated resistance and relaxation with passage of a virtual three-dimensional ventriculostomy catheter through the brain parenchyma into the ventricle. A dynamic three-dimensional graphical interface renders changing visual perspective as the user's head moves. The simulation platform was found to have realistic visual, tactile, and handling characteristics, as assessed by neurosurgical faculty, residents, and medical students. CONCLUSION: We have developed a realistic, haptics-based virtual reality simulator for neurosurgical education. Our first module recreates a critical component of the ventriculostomy placement task. This approach to task simulation can be assembled in a modular manner to reproduce entire neurosurgical procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rheingold, H. (1991) · Cited by 1,867
Guidelines for the Management of Severe Head Injury: What we Know and What we Think we Know
Chesnut, R. M. (1997) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199705001-00004 · Cited by 798
Guidelines for the management of severe head injury
BULLOCK, R., CHESNUT, R. M., CLIFTON, G., GHAJAR, J., MARION, D. W., NARAYAN, R. K., NEWELL, D. W., PITTS, L. H., ROSNER, M. J., & WILBERGER, J. W. (1996) · European Journal of Emergency Medicine · doi:10.1097/00063110-199606000-00010 · Cited by 684
Narayan, R. K., Kishore, P. R. S., Becker, D. P., Ward, J. D., Enas, G. G., Greenberg, R. P., Da Silva, A. D., Lipper, M. H., Choi, S. C., Mayhall, C. G., et al. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.56.5.0650 · Cited by 591 · cited 1×
“Optimal catheter trajectory and positioning are critical to prevent damage to vital neural and vascular structures (7, 10, 29, 31, 34).”
Background(1980) · Springer eBooks · doi:10.1007/978-3-642-67543-0 · Cited by 553
Korndorffer, J. R., Dunne, J. B., Sierra, R., Stefanidis, D., Touchard, C. L., & Scott, D. J. (2005) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2005.02.021 · Cited by 420 · cited 2×
“The system is limited by lower visual acuity (20/112), which would not provide adequate visualization of finer detail (e.g., catheter depth markings) for our ventriculostomy model.”
BackgroundBland, K. I. (2006) · Yearbook of Surgery · doi:10.1016/s0090-3671(08)70537-8 · Cited by 367
Planning and Simulation of Neurosurgery in a Virtual Reality Environment
Kockro, R. A., Serra, L., Tseng-Tsai, Y., Chan, C., Yih-Yian, S., Guan, C. G., Lee, E., Hoe, L. Y., Hern, N., & Nowinski, W. L. (2000) · Neurosurgery · doi:10.1093/neurosurgery/46.1.118 · Cited by 229 · cited 1×
“Often, these simulations can import patient-specific data and act as a form of “operative rehearsal” (4, 19, 38, 41).”
BackgroundStandard setting in medical education
Cusimano, M. D. (1996) · Academic Medicine · doi:10.1097/00001888-199610000-00062 · Cited by 175
Virtual Endoscopy for Planning and Simulation of Minimally Invasive Neurosurgery
Auer, L. M., Auer, L. M., & Auer, D. P. (1998) · Neurosurgery · doi:10.1097/00006123-199809000-00072 · Cited by 96 · cited 1×
“Often, these simulations can import patient-specific data and act as a form of “operative rehearsal” (4, 19, 38, 41).”
BackgroundA virtual reality surgery simulation of cutting and retraction in neurosurgery with force-feedback
Wang, P., Becker, A. A., Jones, I. A., Glover, A. T., Benford, S., Greenhalgh, C., & Vloeberghs, M. H. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.07.006 · Cited by 83
Apuzzo, M. L. J. (1996) · Neurosurgery · doi:10.1097/00006123-199604000-00001 · Cited by 79
Virtual Reality Neurosurgery: A Simulator Blueprint
Spicer, M. A., van Velsen, M., Caffrey, J. P., & Apuzzo, M. L. J. (2004) · Neurosurgery · doi:10.1227/01.neu.0000114139.16118.f2 · Cited by 60 · cited 1×
“More recently, computerbased images and animations have improved our ability to depict complex anatomic relationships (5, 14, 18, 42).”
BackgroundWeb-based Surgical Simulation for Ventricular Catheterization
Phillips, N. I., & John, N. W. (2000) · Neurosurgery · doi:10.1097/00006123-200004000-00031 · Cited by 58 · cited 1×
“In 2000, John and Phillips (15) and Philips and John (35) developed a cross-platform, web-based ventriculostomy simulator.”
BackgroundSchreiber, K., Firlik, A. D., Rj, H., & Ghajar, J. (1993) · PubMed · Cited by 52
Designing cranial implants in a haptic augmented reality environment
Scharver, C., Evenhouse, R., Johnson, A. E., & Leigh, J. (2004) · Communications of the ACM · doi:10.1145/1012037.1012059 · Cited by 50 · cited 1×
“The Personal Augmented Reality Immersive System, also developed at the University of Illinois, represents the earliest virtual/augmented reality platform to effectively combine haptic feedback with dynamic graphical rendering in a computer-based simulator (2, 16, 40).”
BackgroundLiu, C. Y., Spicer, M. A., & Apuzzo, M. L. J. (2003) · Neurosurgery · doi:10.1097/00006123-200301000-00002 · Cited by 41
Modelling of interaction between a spatula and a human brain
Hansen, K. V., Brix, L. C., Pedersen, C. F., Haase, J., & Larsen, O. V. (2003) · Medical Image Analysis · doi:10.1016/j.media.2003.07.001 · Cited by 40 · cited 1×
“One of the most exciting avenues of exploration has been the use of virtual reality simulators to model not only force resistance, but also neurological tissue deformations in response to force perturbations (13, 21, 44).”
BackgroundThe Virtual Brain Project--development of a neurosurgical simulator.
Larsen, O. V., Haase, J., Østergaard, L. R., Hansen, K. V., & Nielsen, H. (2001) · PubMed · Cited by 31
Virtual environment-based training simulator for endoscopic third ventriculostomy.
Brown, N., Natsupakpong, S., Johannsen, S., Manjila, S. V., Cai, Q., Liberatore, V., Cohen, A. R., & Çavuşoğlu, M. C. (2006) · PubMed · Cited by 19
Infracranial Pressure Monitoring
Kanter, M. J., & Narayan, R. K. (1991) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30734-4 · Cited by 19 · cited 1×
“%) associated with catheter placement (17, 23).”
Cited by
Immersive virtual reality as a teaching tool for neuroanatomy
Stepan, K., Zeiger, J., Hanchuk, S., Del Signore, A., Shrivastava, R., Govindaraj, S., & Iloreta, A. (2017) · International Forum of Allergy & Rhinology · doi:10.1002/alr.21986 · Cited by 402
Jang, S., Vitale, J. M., Jyung, R. W., & Black, J. B. (2017) · Computers & Education · doi:10.1016/j.compedu.2016.12.009 · Cited by 320
Virtual Reality and Simulation in Neurosurgical Training
Bernardo, A. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.06.140 · Cited by 314
Tang, Y. M., Chau, K. Y., Kwok, A. P. K., Zhu, T., & Ma, X. (2022) · Educational Research Review · doi:10.1016/j.edurev.2021.100429 · Cited by 281
Virtual Reality and Augmented Reality in Plastic Surgery: A Review
Kim, Y., Kim, H., & Kim, Y. O. (2017) · Archives of Plastic Surgery · doi:10.5999/aps.2017.44.3.179 · Cited by 267
Metadata
- Authors
- Lemole, G. M., Banerjee, P. P., Luciano, C., Neckrysh, S., & Charbel, F. T.
- Venue
- Neurosurgery
- Published
- 2007-07
- Volume
- 61
- Issue
- 1
- Pages
- 142-149
- ISSN
- 0148-396X (ISSN-L)
- OpenAlex
- W2059205775
- Cited by
- 205
- References
- 21
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.